NHTSA owner reports · September 18, 2026 snapshot.
Fuel System, Gasoline complaints
30 reportsClear category filterMileage unknown · Mar 26, 2008
Fuel System, Gasoline
TL*THE CONTACT OWNS A 1995 MERCURY MYSTIQUE. WHILE ADDING FUEL TO THE VEHICLE, SHE WAS NOTICED THERE WAS A GAS LEAK. THE DEALER STATED THAT THE PART WAS NO LONGER MADE AND THEY WERE UNABLE TO ASSIST HER. THE DEALER IS AWARE OF RECALL, 95V232000 - FUEL SYSTEM, GASOLINE:STORAGE:TANK ASSEMBLY:FILLER PIPE AND CAP. SHE WAS ALSO ADVI…
Read full complaint
TL*THE CONTACT OWNS A 1995 MERCURY MYSTIQUE. WHILE ADDING FUEL TO THE VEHICLE, SHE WAS NOTICED THERE WAS A GAS LEAK. THE DEALER STATED THAT THE PART WAS NO LONGER MADE AND THEY WERE UNABLE TO ASSIST HER. THE DEALER IS AWARE OF RECALL, 95V232000 - FUEL SYSTEM, GASOLINE:STORAGE:TANK ASSEMBLY:FILLER PIPE AND CAP. SHE WAS ALSO ADVISED THAT IT DID NOT APPLY TO HER VEHICLE IDENTIFICATION NUMBER. UPDATED .*BF
NHTSA ODI #10222406
66,402 miles · Oct 20, 2006
Fuel System, Gasoline
DT*: THE CONTACT STATED WHILE DRIVING VARIOUS SPEEDS, A GAS SMELL WAS NOTICED DUE TO A GAS LEAK. THE VEHICLE WAS DRIVEN TO THE DEALER WHO DETERMINED A GAS LEAK IN THE FILLER HOSE WAS PRESENT. THERE WAS A NHTSA RECALL, # 95V232000, REGARDING THE GAS TANK FILLER HOSE AND CAP. THE VEHICLE WAS NOT INCLUDED IN THE RECALL DUE TO TH…
Read full complaint
DT*: THE CONTACT STATED WHILE DRIVING VARIOUS SPEEDS, A GAS SMELL WAS NOTICED DUE TO A GAS LEAK. THE VEHICLE WAS DRIVEN TO THE DEALER WHO DETERMINED A GAS LEAK IN THE FILLER HOSE WAS PRESENT. THERE WAS A NHTSA RECALL, # 95V232000, REGARDING THE GAS TANK FILLER HOSE AND CAP. THE VEHICLE WAS NOT INCLUDED IN THE RECALL DUE TO THE VIN.
NHTSA ODI #10171426
Mileage unknown · Jan 15, 2004
Engine And Engine CoolingEquipmentFuel System, Gasoline
I'VE HAD THIS CAR ABOUT 5 YEARS AND HAD NOTHING BUT PROBLEMS THERE WAS A ROTTEN EGG SMELL A SMELL LIKE A FIRE CRACKER ELECTICAL PROBLEMS CAR CUTS OFF OVER HEATS THERE ARE SO MANY THINGS WRONG AND I CAN NOT AFFORD TO BUT A NEW CAR RIGHT NOW IT HAS BEEN IN AND OUT OF FORD AND MERCURY DEALERSHIPS FOR REPAIR
NHTSA ODI #10068841
Mileage unknown · Oct 21, 2003
Fuel System, Gasoline
REQUEST FOR REIMBURSEMENT FOR REPLACEMENT OF GAS TANK SINCE IT IS A PRODUCT OF A DEFECT.*MR GAS STATION ATTENDANT WAS FUELING THE VEHICLE WHEN A LARGE PUDDLE OF GAS LEAKED FORM UNDER THE VEHICLE. VEHICLE WAS TAKEN TO THE MECHANIC WHO STATED IT SHOULD BE COVERED BY FORD. PRIOR TO THIS INCIDENT, THE GAS TANK KEPT SHUTTING OFF …
Read full complaint
REQUEST FOR REIMBURSEMENT FOR REPLACEMENT OF GAS TANK SINCE IT IS A PRODUCT OF A DEFECT.*MR GAS STATION ATTENDANT WAS FUELING THE VEHICLE WHEN A LARGE PUDDLE OF GAS LEAKED FORM UNDER THE VEHICLE. VEHICLE WAS TAKEN TO THE MECHANIC WHO STATED IT SHOULD BE COVERED BY FORD. PRIOR TO THIS INCIDENT, THE GAS TANK KEPT SHUTTING OFF AUTOMATICALLY AND THE ATTENDANT HAD TO PUMP IT SLOWLY TO KEEP IT FROM SHUTTING OFF WHILE BEING FILLED. CONSUMER WAS TOLD BY THE DEALERSHIP THE VEHICLE WOULD BE LOOKED OVER AND IT WAS DEPENDENT UPON THE MILEAGE AND CONDITION OF THE VEHICLE. CONSUMER CONTACTED THE MECHANIC AND RELAYED THE INFO. FROM THE DEALERSHIP. MECHANIC STATED HIS COMPUTER SHOWED A RECALL FOR THE FUEL TANK AND SHOULD BE COVERED. CONSUMER AGAIN CONTACTED ANOTHER FORD DEALERSHIP WHO STATED THERE WAS NO RECALL. MECHANIC DID REPAIR VEHICLE. *PH
NHTSA ODI #10044455
Mileage unknown · Feb 6, 2003
Fuel System, Gasoline
NHTSA#94-V-203-000, HAS THE SAME PROBLEM. DEALER HAS BEEN NOTIFIED AND WILL INSTALL A NEW FUEL TANK AT CONSUMER EXPENSE. PLEASE PROVIDE FURTHER INFORMATION. PH
NHTSA ODI #10006695
Mileage unknown · Apr 1, 2002
Fuel System, Gasoline
FUEL TANK WAS REPLACED TWICE DUE TO RECALLS 94S97 AND 95S30, ON 12-JUL-2001, DEALER STATED FUEL TANK NEEDED TO BE REPLACED AGAIN, HOWEVER THIS TIME AT CONSUMERS EXPENSE, CONSUMER IS REQUESTING REIMBURSEMENT FOR THE REPAIR COSTS AND RENTAL CAR EXPENSES. *SLC
NHTSA ODI #564879
Mileage unknown · Sep 17, 2001
Fuel System, Gasoline
VEHICLE STALLED IN TRAFFIC AFTER MAKING A TURN IN WET WEATHER. WHEN TURNING, THERE WOULD BE NOISE PRIOR TO STALLING. PROBLEM WAS INTERMITTENT, AND GETTING WORSE. NOTICED TECHNICAL SERVICE BULLETIN THAT INDICATED AN AIR INTAKE KIT TO CORRECT STALLING PROBLEM. VEHICLE HAS SINCE BEEN REPAIRED.*AK
NHTSA ODI #896410
Mileage unknown · Sep 12, 2001
Engine And Engine CoolingFuel System, GasolineSeats
THE ENGINE LIGHT CAME ON AND VEHICLE OVERHEATED, CONSUMER WAS INFORMED THAT A NEW WATER PUMP WAS NEEDED, CONSUMER ALSO STATES THERE ARE FUMES COMING FROM THE ENGINE, THE FUMES COME INSIDE THE VEHICLE WHEN IT IS WARM, WHETHER OR NOT THE A/C IS ON.*JB
NHTSA ODI #563017
Mileage unknown · May 21, 2001
Electrical SystemEngine And Engine CoolingFuel System, Gasoline
THE FUEL RAIL BURST WHILE DRIVING CAUSING FUEL TO SPRAY ONTO THE HOT ENGINE RESULTING IN FIRE, DURING REPAIR OF THE FUEL RAIL THE DEALER FOUND THAT THE WATER PUMP SHEARED OFF AND REPLACE THE PUMP AND PUMP DRIVE BELT, THE DEALER ALSO FOUND THAT THERE WAS NO COMPRESSION IN 4 OF CYLINDER, THE TIMING CHAIN FAILED CAUSING VALVE DAMAG…
Read full complaint
THE FUEL RAIL BURST WHILE DRIVING CAUSING FUEL TO SPRAY ONTO THE HOT ENGINE RESULTING IN FIRE, DURING REPAIR OF THE FUEL RAIL THE DEALER FOUND THAT THE WATER PUMP SHEARED OFF AND REPLACE THE PUMP AND PUMP DRIVE BELT, THE DEALER ALSO FOUND THAT THERE WAS NO COMPRESSION IN 4 OF CYLINDER, THE TIMING CHAIN FAILED CAUSING VALVE DAMAGE, THE DEALER SUGGEST THE ENTIRE ENGINE BE REPALCED. NLM
NHTSA ODI #561290
Mileage unknown · May 2, 2001
Fuel System, Gasoline
FUEL TANK IS LEAKING FUEL, CONSUMER HAD FUEL FILLER LINE REPLACED IN 1998. CURRENTLY, IT NEEDS TO BE REPLACED AGAIN. THERE IS A RECALL, BUT THIS VEHICLE IS NOT AFFECTED DUE TO VIN. *AK
NHTSA ODI #887283
Official recalls
8Nov 6, 2000
VEHICLE DESCRIPTION: 1995 PASSENGER VEHICLES EQUIPPED WITH THE 2.0L AND 2.5L ENGINES, AND 1996 VEHICLES EQUIPPED WITH 2.5L ENGINES. TIGHTENING OF THE ENGINE COOLING FAN MOTOR BEARINGS, UP TO AND INCLUDING MOTOR STALL, CAN RESULT IN INCREASED MOTOR TORQUE AND HIGHER THAN NORMAL MOTOR CURRENT AND ACCOMPANYING HIGH MOTOR TEMPERATURES.
Consequence & remedy
Consequence: OVERHEATING OF THE COOLING FAN MOTOR DUE TO EXCESSIVE CURRENT CAN RESULT IN SMOKE AND ODORS FROM BEARING GREASE, INSULATION AND OTHER INTERNAL MOTOR COMPONENTS. IF ELECTRICAL CURRENT CONTINUES TO BE APPLIED TO THE MOTOR, INTERNAL MOTOR COMPONENTS COULD IGNITE POSSIBLY IGNITING OTHER ENGINE COMPARTMENT COMPONENTS.
Remedy: DEALERS WILL INSTALL A POSITIVE TEMPERATURE COEFFICIENT DEVICE IN-LINE WITH EACH FAN MOTOR. FORD WILL ALSO EXTEND THE WARRANTY ON THE ENGINE COOLING FAN ASSEMBLY TO A TOTAL OF 8 YEARS OF SERVICE OR 100,000 MILES FROM THE WARRANTY START DATE, WHICHEVER OCCURS FIRST. IF THE VEHICLE ALREADY HAS MORE THAN 100,000 MILES, THIS COVERAGE WILL LAST UNTIL JULY 31, 2001.
Sep 18, 1998
VEHICLE DESCRIPTION: PASSENGER VEHICLES. THE FLOOR SHIFT AUTOMATIC TRANSMISSION CONTROL CAN BE DAMAGED IF SUBJECTED TO CERTAIN INTERIOR CLEANING PRODUCTS. THE GEAR POSITION INDICATOR CAN DETERIORATE AND NOT CORRECTLY INDICATE THE ACTUAL GEAR POSITION.
Consequence & remedy
Consequence: THIS CONDITION CAN RESULT IN INCORRECT GEAR SELECTION.
Remedy: DEALERS WILL REPLACE THE AUTOMATIC TRANSMISSION FLOOR SHIFT CONTROL.
Dec 8, 1997
VEHICLE DESCRIPTION: PASSENGER VEHICLES EQUIPPED WITH THE TRACTION CONTROL OPTION. THE THROTTLE CABLES WERE DAMAGED DURING VEHICLE ASSEMBLY LEADING TO FRAYING OR SEPARATION OF THE THROTTLE CABLE.
Consequence & remedy
Consequence: THIS CONDITION COULD PREVENT THE ENGINE FROM RETURNING TO IDLE.
Remedy: DEALERS WILL REPLACE THE THROTTLE CABLE WITH A REVISED DESIGN THAT IS LESS SUSCEPTIBLE TO BENDING OR KINKING DURING INSTALLATION.
Dec 5, 1995
THE FUEL TANK FILLER PIPE OPENING REINFORCEMENT, CONSTRUCTED FROM TWO SEPARATELY MOLDED PIECES, CAN LEAK AT THE WELD.
Consequence & remedy
Consequence: FUEL LEAKAGE CAN RESULT IN A FIRE.
Remedy: DEALERS WILL REPLACE THE FUEL TANK ASSEMBLIES WITH UNITS CONTAINING ONE-PIECE MOLDED REINFORCEMENTS.
Dec 4, 1995
CRACKS HAVE BEEN FOUND IN THE FRONT SAFETY BELT OUTBOARD ANCHOR TABS DUE TO A COMBINATION OF HYDROGEN EMBRITTLEMENT OF THE TAB AND STRESS INTRODUCED DURING ATTACHMENT OF THE ANCHOR TAB TO THE SEAT FRAME. THIS DOES NOT CONFORM WITH THE REQUIREMENTS OF FMVSS NO. 210, "SEAT BELT ASSEMBLY ANCHORAGES."
Consequence & remedy
Consequence: CONSEQUENCE OF NON-COMPLIANCE: A FRACTURE OR SEPARATION IN THIS AREA WOULD REDUCE THE LOAD THAT THE ANCHOR AND THE FRONT SAFETY BELT ANCHORAGES COULD SUSTAIN, INCREASING THE RISK OF INJURY IN A VEHICLE COLLISOIN.
Remedy: DEALERS WILL INSPECT AND INSTALL AN ANCHOR TAB REINFORCEMENT OR REPLACEMENT OF THE COMPLETE FRONT SEAT BELT ASSEMBLY IF AN ANCHOR TAB IS FOUND TO HAVE FRACTURED.
Jan 24, 1995
THE GLASS TEMPERING PROCESS ON THE RIGHT HAND REAR DOOR WINDOWS WAS NOT CORRECTLY PERFORMED. THIS DOES NOT MEET THE REQUIREMENTS OF FMVSS NO. 205, "GLAZING MATERIALS."
Consequence & remedy
Consequence: CONSEQUENCE OF NON-COMPLIANCE: IF THE WINDOW BREAKS, THE GLASS FRAGMENTS OF THE REAR WINDOWS EXCEED THE SIZE SPECIFICATIONS OF FMVSS NO. 205.
Remedy: DEALERS WILL REPLACE THE RIGHT REAR DOOR GLASS.
Oct 18, 1994
THE FUEL TANK FILLER PIPE OPENING REINFORCEMENT CAN LEAK AT THE WELD.
Consequence & remedy
Consequence: FUEL LEAKAGE CAN RESULT IN A FIRE.
Remedy: DEALERS WILL INSPECT AND, AS APPROPRIATE, REPLACE THE FUEL TANKS.
Sep 29, 1994
A METAL SHIELD ON THE OUTSIDE OF THE PLASTIC FUEL FILLER PIPE CAN DEVELOP A STATIC ELECTRICAL CHARGE DURING REFUELING OF THE VEHICLE.
Consequence & remedy
Consequence: A STATIC CHARGE CAN DISCHARGE AND SERVE AS AN IGNITION SOURCE FOR FUEL VAPORS IN THE AREA OF THE FILLER PIPE, RESULTING IN A FLASH VAPOR IGNITION AND A VEHICLE FIRE.
Remedy: DEALERS WILL INSPECT AND, IF NECESSARY, MODIFY THE VEHICLES BY ADDING A GROUND STRAP BETWEEN THE FILLER PIPE SHIELD AND THE BODY.
Model-level recall history does not show whether a particular VIN is affected or has received a repair. Check a VIN with NHTSA ↗
NHTSA investigations
6RQ02006 · Incorrect Gear Indication
Opened Feb 26, 2002 · Closed Sep 12, 2002
Status: closed (inferred from source dates) · Power Train
There is no summary currently available
EA01001 · Blower Switch/resistor Or Wiring Harness
Opened Jan 5, 2001 · Closed Jul 31, 2001
Status: closed (inferred from source dates) · Electrical System
There is no summary currently available
Additional source detail variants (2)
Electrical System
There is no summary currently available
Electrical System
There is no summary currently available
PE00023 · Blower Switch/resistor Or Wiring Harness
Opened Jun 14, 2000 · Closed Jan 5, 2001
Status: closed (inferred from source dates) · Electrical System
There is no summary currently available
EA00005 · Engine Cooling Fan Fires
Opened Feb 23, 2000 · Closed Nov 9, 2000
Status: closed (inferred from source dates) · Engine And Engine Cooling
There is no summary currently available
RQ99019 · Various Intermittent Electrical Issues
Opened Sep 15, 1999 · Closed Mar 7, 2001
Status: closed (inferred from source dates) · Unknown Or Other
There is no summary currently available
PE99052 · Engine Cooling Fan Fires
Opened Aug 18, 1999 · Closed Feb 23, 2000
Status: closed (inferred from source dates) · Engine And Engine Cooling
ODI OPENED THIS INVESTIGATION ON AUGUST 18, 1999, BASED ON FOUR REPORTS OF FIRE INVOLVING THE ENGINE COOLING FAN.THE REPORTS ALLEGE THE ELECTRONIC COOLING FAN CAUGHT FIRE WITH RESULTANT DAMAGE TO THE FAN AND WIRE HARNESS AND/OR THE HARNESS CONNECTOR.IN ITS PE RESPONSE, FORD PROVIDED INFORMATION RELEVANT TO 46 ADDITIONAL ALLEGED FIRE INCIDENTS AND 47 ALLEGED FAILURES OF THE COOLING FAN INVOLVING THERMAL DAMAGE TO THE FAN.THIS INVESTIGATION HAS BEEN UPGRADED TO FURTHER STUDY THE ISSUE.