← New search

2014 Heil Half/Pack Freedom

Owner reports · Recalls · Investigations

Limited comparison data

There is not enough comparable history to draw a useful model-year comparison.

About this comparison →

How this year compares

Owner complaints by model year

Other model years Selected year
Compare all Half/pack Freedom years →

Counts vary with age, sales and reporting. They are not failure rates.

What owners reported most

No component reports in this snapshot.

Tap a category to read its complaints. One report may name several components.

When problems were reported

Mileage at the reported incident

Limited mileage data: 0 of 0 reports include usable mileage. There isn’t enough coverage to show a useful chart.

NHTSA’s mileage field refers to the reported incident, not necessarily the filing date. This shows report counts, not the likelihood of a failure.

NHTSA owner reports · September 18, 2026 snapshot.

0 crash reports0 fire reports0 injury reports

What owners actually said

0 reports

No matching complaints in this snapshot.

Official recalls

0

No recalls in this snapshot.

Model-level recall history does not show whether a particular VIN is affected or has received a repair. Check a VIN with NHTSA ↗

NHTSA investigations

1

PE15006 · Cng Fuel Container Burst During A Fire

Opened Feb 27, 2015 · Closed Jan 8, 2016

Status: closed (inferred from source dates) · Fuel System, Other; Fuel System, Other:storage; Fuel System, Other:storage:tank Assembly; Fuel System, Other:storage:tank Assembly:pressure Relief Devices

On January 27, 2015 in Indianapolis, Indiana, a model year 2014 Autocar ACX / Heil Half/Pack Freedom refuse collection truck caught fire and experienced a catastrophic CNG fuel container burst. Office of Defects Investigation (ODI) personnel conducted a field examination of the incident vehicle, an exemplar vehicle and the incident scene, and subsequently sent information request letters to Autocar LLC, The Heil Company, Agility Fuel Systems Inc. and Hexagon Lincoln Inc.After a review of all available information, it appears that this was an isolated incident. The vehicle fire originated in the refuse storage bay and was caused by a hot load, which is a quantity of solid waste that catches fire, smolders or spontaneously combusts as a result of incompatible waste materials mixing together. Drivers are trained to eject the hot load in an empty lot, when feasible. In this instance, the driver did not eject the hot load. After expending a hand-held fire extinguisher into the hopper area of the refuse storage bay, the driver retreated from the vehicle. Fire fighters arrived at the incident scene within minutes. During firefighting efforts, two CNG fuel containers burst, sending materials into the air and across a large debris field.One fire fighter was struck in the head and shoulder area by falling debris and sustained minor injury. He was examined at the scene and did not require transport but was later transported post-incident to a medical clinic where he was diagnosed with a muscle strain to his left shoulder. Multiple structures suffered property damage and the subject vehicle was a total loss. The fire was brought under control and was extinguished 1 hour and 38 minutes after fire fighters first arrived.Post-incident analysis, including a review of the fire department?s after action report, identified several contributing factors. The truck driver was unable or unwilling to eject the hot load. Fire fighters initially misidentified the subject fuel system as liquefied petroleum gas (LPG) and believed cooling was necessary to prevent a boiling liquid expanding vapor explosion (BLEVE). Fire fighters were unfamiliar with natural gas vehicle fires, associated risks and best practices for firefighting techniques and tactics. The CNG fuel containers were located directly above the origin of the fire and were impinged by flame, thus weakening their structural integrity. The CNG fuel containers were mounted transversely with thermally-activated pressure relief devices (PRDs) mounted in each end, away from where the fire was localized. The CNG fuel containers were of Type 4 construction and thus were not good conductors of heat away from where the fire was localized and towards the PRDs. The CNG fuel containers were covered by a steel enclosure with small, circular openings providing access to the manual fuel container isolation valves equipped with integrated PRDs. Water applied to the fire likely cooled the PRDs but did not reach the area of the fuel containers where the fire was localized, thus keeping the PRDs below the activation temperature threshold as the fire progressed.ODI is aware of at least one other incident in which a substantially similar CNG refuse truck caught fire due to a hot load. In that case, the PRDs activated as intended. There was no fire suppression effort prior to the PRDs activating.The National Fire Protection Association (NFPA) Alternative Fuel Vehicle (AFV) Safety Training project (http://www.evsafetytraining.org) provides training for first responders who face emergency situations involving motor vehicles.NFPA training advises that attempts to extinguish a significant CNG fire could prevent

Additional source detail variants (4)

Fuel System, Other

On January 27, 2015 in Indianapolis, Indiana, a model year 2014 Autocar ACX / Heil Half/Pack Freedom refuse collection truck caught fire and experienced a catastrophic CNG fuel container burst. Office of Defects Investigation (ODI) personnel conducted a field examination of the incident vehicle, an exemplar vehicle and the incident scene, and subsequently sent information request letters to Autocar LLC, The Heil Company, Agility Fuel Systems Inc. and Hexagon Lincoln Inc.After a review of all available information, it appears that this was an isolated incident. The vehicle fire originated in the refuse storage bay and was caused by a hot load, which is a quantity of solid waste that catches fire, smolders or spontaneously combusts as a result of incompatible waste materials mixing together. Drivers are trained to eject the hot load in an empty lot, when feasible. In this instance, the driver did not eject the hot load. After expending a hand-held fire extinguisher into the hopper area of the refuse storage bay, the driver retreated from the vehicle. Fire fighters arrived at the incident scene within minutes. During firefighting efforts, two CNG fuel containers burst, sending materials into the air and across a large debris field.One fire fighter was struck in the head and shoulder area by falling debris and sustained minor injury. He was examined at the scene and did not require transport but was later transported post-incident to a medical clinic where he was diagnosed with a muscle strain to his left shoulder. Multiple structures suffered property damage and the subject vehicle was a total loss. The fire was brought under control and was extinguished 1 hour and 38 minutes after fire fighters first arrived.Post-incident analysis, including a review of the fire department?s after action report, identified several contributing factors. The truck driver was unable or unwilling to eject the hot load. Fire fighters initially misidentified the subject fuel system as liquefied petroleum gas (LPG) and believed cooling was necessary to prevent a boiling liquid expanding vapor explosion (BLEVE). Fire fighters were unfamiliar with natural gas vehicle fires, associated risks and best practices for firefighting techniques and tactics. The CNG fuel containers were located directly above the origin of the fire and were impinged by flame, thus weakening their structural integrity. The CNG fuel containers were mounted transversely with thermally-activated pressure relief devices (PRDs) mounted in each end, away from where the fire was localized. The CNG fuel containers were of Type 4 construction and thus were not good conductors of heat away from where the fire was localized and towards the PRDs. The CNG fuel containers were covered by a steel enclosure with small, circular openings providing access to the manual fuel container isolation valves equipped with integrated PRDs. Water applied to the fire likely cooled the PRDs but did not reach the area of the fuel containers where the fire was localized, thus keeping the PRDs below the activation temperature threshold as the fire progressed.ODI is aware of at least one other incident in which a substantially similar CNG refuse truck caught fire due to a hot load. In that case, the PRDs activated as intended. There was no fire suppression effort prior to the PRDs activating.The National Fire Protection Association (NFPA) Alternative Fuel Vehicle (AFV) Safety Training project (http://www.evsafetytraining.org) provides training for first responders who face emergency situations involving motor vehicles.NFPA training advises that attempts to extinguish a significant CNG fire could prevent

Fuel System, Other:storage

On January 27, 2015 in Indianapolis, Indiana, a model year 2014 Autocar ACX / Heil Half/Pack Freedom refuse collection truck caught fire and experienced a catastrophic CNG fuel container burst. Office of Defects Investigation (ODI) personnel conducted a field examination of the incident vehicle, an exemplar vehicle and the incident scene, and subsequently sent information request letters to Autocar LLC, The Heil Company, Agility Fuel Systems Inc. and Hexagon Lincoln Inc.After a review of all available information, it appears that this was an isolated incident. The vehicle fire originated in the refuse storage bay and was caused by a hot load, which is a quantity of solid waste that catches fire, smolders or spontaneously combusts as a result of incompatible waste materials mixing together. Drivers are trained to eject the hot load in an empty lot, when feasible. In this instance, the driver did not eject the hot load. After expending a hand-held fire extinguisher into the hopper area of the refuse storage bay, the driver retreated from the vehicle. Fire fighters arrived at the incident scene within minutes. During firefighting efforts, two CNG fuel containers burst, sending materials into the air and across a large debris field.One fire fighter was struck in the head and shoulder area by falling debris and sustained minor injury. He was examined at the scene and did not require transport but was later transported post-incident to a medical clinic where he was diagnosed with a muscle strain to his left shoulder. Multiple structures suffered property damage and the subject vehicle was a total loss. The fire was brought under control and was extinguished 1 hour and 38 minutes after fire fighters first arrived.Post-incident analysis, including a review of the fire department?s after action report, identified several contributing factors. The truck driver was unable or unwilling to eject the hot load. Fire fighters initially misidentified the subject fuel system as liquefied petroleum gas (LPG) and believed cooling was necessary to prevent a boiling liquid expanding vapor explosion (BLEVE). Fire fighters were unfamiliar with natural gas vehicle fires, associated risks and best practices for firefighting techniques and tactics. The CNG fuel containers were located directly above the origin of the fire and were impinged by flame, thus weakening their structural integrity. The CNG fuel containers were mounted transversely with thermally-activated pressure relief devices (PRDs) mounted in each end, away from where the fire was localized. The CNG fuel containers were of Type 4 construction and thus were not good conductors of heat away from where the fire was localized and towards the PRDs. The CNG fuel containers were covered by a steel enclosure with small, circular openings providing access to the manual fuel container isolation valves equipped with integrated PRDs. Water applied to the fire likely cooled the PRDs but did not reach the area of the fuel containers where the fire was localized, thus keeping the PRDs below the activation temperature threshold as the fire progressed.ODI is aware of at least one other incident in which a substantially similar CNG refuse truck caught fire due to a hot load. In that case, the PRDs activated as intended. There was no fire suppression effort prior to the PRDs activating.The National Fire Protection Association (NFPA) Alternative Fuel Vehicle (AFV) Safety Training project (http://www.evsafetytraining.org) provides training for first responders who face emergency situations involving motor vehicles.NFPA training advises that attempts to extinguish a significant CNG fire could prevent

Fuel System, Other:storage:tank Assembly

On January 27, 2015 in Indianapolis, Indiana, a model year 2014 Autocar ACX / Heil Half/Pack Freedom refuse collection truck caught fire and experienced a catastrophic CNG fuel container burst. Office of Defects Investigation (ODI) personnel conducted a field examination of the incident vehicle, an exemplar vehicle and the incident scene, and subsequently sent information request letters to Autocar LLC, The Heil Company, Agility Fuel Systems Inc. and Hexagon Lincoln Inc.After a review of all available information, it appears that this was an isolated incident. The vehicle fire originated in the refuse storage bay and was caused by a hot load, which is a quantity of solid waste that catches fire, smolders or spontaneously combusts as a result of incompatible waste materials mixing together. Drivers are trained to eject the hot load in an empty lot, when feasible. In this instance, the driver did not eject the hot load. After expending a hand-held fire extinguisher into the hopper area of the refuse storage bay, the driver retreated from the vehicle. Fire fighters arrived at the incident scene within minutes. During firefighting efforts, two CNG fuel containers burst, sending materials into the air and across a large debris field.One fire fighter was struck in the head and shoulder area by falling debris and sustained minor injury. He was examined at the scene and did not require transport but was later transported post-incident to a medical clinic where he was diagnosed with a muscle strain to his left shoulder. Multiple structures suffered property damage and the subject vehicle was a total loss. The fire was brought under control and was extinguished 1 hour and 38 minutes after fire fighters first arrived.Post-incident analysis, including a review of the fire department?s after action report, identified several contributing factors. The truck driver was unable or unwilling to eject the hot load. Fire fighters initially misidentified the subject fuel system as liquefied petroleum gas (LPG) and believed cooling was necessary to prevent a boiling liquid expanding vapor explosion (BLEVE). Fire fighters were unfamiliar with natural gas vehicle fires, associated risks and best practices for firefighting techniques and tactics. The CNG fuel containers were located directly above the origin of the fire and were impinged by flame, thus weakening their structural integrity. The CNG fuel containers were mounted transversely with thermally-activated pressure relief devices (PRDs) mounted in each end, away from where the fire was localized. The CNG fuel containers were of Type 4 construction and thus were not good conductors of heat away from where the fire was localized and towards the PRDs. The CNG fuel containers were covered by a steel enclosure with small, circular openings providing access to the manual fuel container isolation valves equipped with integrated PRDs. Water applied to the fire likely cooled the PRDs but did not reach the area of the fuel containers where the fire was localized, thus keeping the PRDs below the activation temperature threshold as the fire progressed.ODI is aware of at least one other incident in which a substantially similar CNG refuse truck caught fire due to a hot load. In that case, the PRDs activated as intended. There was no fire suppression effort prior to the PRDs activating.The National Fire Protection Association (NFPA) Alternative Fuel Vehicle (AFV) Safety Training project (http://www.evsafetytraining.org) provides training for first responders who face emergency situations involving motor vehicles.NFPA training advises that attempts to extinguish a significant CNG fire could prevent

Fuel System, Other:storage:tank Assembly:pressure Relief Devices

On January 27, 2015 in Indianapolis, Indiana, a model year 2014 Autocar ACX / Heil Half/Pack Freedom refuse collection truck caught fire and experienced a catastrophic CNG fuel container burst. Office of Defects Investigation (ODI) personnel conducted a field examination of the incident vehicle, an exemplar vehicle and the incident scene, and subsequently sent information request letters to Autocar LLC, The Heil Company, Agility Fuel Systems Inc. and Hexagon Lincoln Inc.After a review of all available information, it appears that this was an isolated incident. The vehicle fire originated in the refuse storage bay and was caused by a hot load, which is a quantity of solid waste that catches fire, smolders or spontaneously combusts as a result of incompatible waste materials mixing together. Drivers are trained to eject the hot load in an empty lot, when feasible. In this instance, the driver did not eject the hot load. After expending a hand-held fire extinguisher into the hopper area of the refuse storage bay, the driver retreated from the vehicle. Fire fighters arrived at the incident scene within minutes. During firefighting efforts, two CNG fuel containers burst, sending materials into the air and across a large debris field.One fire fighter was struck in the head and shoulder area by falling debris and sustained minor injury. He was examined at the scene and did not require transport but was later transported post-incident to a medical clinic where he was diagnosed with a muscle strain to his left shoulder. Multiple structures suffered property damage and the subject vehicle was a total loss. The fire was brought under control and was extinguished 1 hour and 38 minutes after fire fighters first arrived.Post-incident analysis, including a review of the fire department?s after action report, identified several contributing factors. The truck driver was unable or unwilling to eject the hot load. Fire fighters initially misidentified the subject fuel system as liquefied petroleum gas (LPG) and believed cooling was necessary to prevent a boiling liquid expanding vapor explosion (BLEVE). Fire fighters were unfamiliar with natural gas vehicle fires, associated risks and best practices for firefighting techniques and tactics. The CNG fuel containers were located directly above the origin of the fire and were impinged by flame, thus weakening their structural integrity. The CNG fuel containers were mounted transversely with thermally-activated pressure relief devices (PRDs) mounted in each end, away from where the fire was localized. The CNG fuel containers were of Type 4 construction and thus were not good conductors of heat away from where the fire was localized and towards the PRDs. The CNG fuel containers were covered by a steel enclosure with small, circular openings providing access to the manual fuel container isolation valves equipped with integrated PRDs. Water applied to the fire likely cooled the PRDs but did not reach the area of the fuel containers where the fire was localized, thus keeping the PRDs below the activation temperature threshold as the fire progressed.ODI is aware of at least one other incident in which a substantially similar CNG refuse truck caught fire due to a hot load. In that case, the PRDs activated as intended. There was no fire suppression effort prior to the PRDs activating.The National Fire Protection Association (NFPA) Alternative Fuel Vehicle (AFV) Safety Training project (http://www.evsafetytraining.org) provides training for first responders who face emergency situations involving motor vehicles.NFPA training advises that attempts to extinguish a significant CNG fire could prevent