← New search

1991 Ford F-250

Owner reports · Recalls · Investigations

Similar to other model years

Owner complaints for the 1991 Ford F-250 do not stand out strongly from the model-year median of 119.

About this comparison →

How this year compares

Owner complaints by model year

Other model years Selected year
Compare all F-250 years →

Counts vary with age, sales and reporting. They are not failure rates.

What owners reported most

All reported categories

Tap a category to read its complaints. One report may name several components.

When problems were reported

Mileage at the reported incident

Limited mileage data: 15 of 107 reports include usable mileage. There isn’t enough coverage to show a useful chart.

NHTSA’s mileage field refers to the reported incident, not necessarily the filing date. This shows report counts, not the likelihood of a failure.

What to inspect

Issues worth paying extra attention to based on owner reports.

  • Fuel System, Gasoline. Review the 26 owner reports in this category and discuss these concerns during a pre-purchase inspection. Read reports →
  • Service Brakes, Hydraulic. Review the 24 owner reports in this category and discuss these concerns during a pre-purchase inspection. Read reports →
  • Electrical System. Review the 15 owner reports in this category and discuss these concerns during a pre-purchase inspection. Read reports →

NHTSA owner reports · September 18, 2026 snapshot.

5 crash reports9 fire reports3 injury reports

What owners actually said

107 reports
Mileage unknown · Aug 29, 2001
Exterior Lighting

HEADLIGHT SWITCH IS FAULTY CAUSING THE LIGHTS TO FAIL WHILE DRIVING. NLM

NHTSA ODI #785500

Mileage unknown · Jun 7, 2001
Electrical System

RECALL 96 V 071 00/ELECTRICAL SYSTEM IGNITION: VEHICLE EXPERIENCING PROBLEM WITH IGNITION SWITCH FAILING TO OPERATE/ WILL NOT TURN ON. HAD TO DISCONNECT SWITCH AND HOT WIRE TO GET VEHICLE TO START. MANUFACTURER NOTIFIED, AND INFORMED CONSUMER THAT THEY COULD NOT LOCATE VIN SYSTEM. ASKING NHTSA TO HELP IN THIS MATTER. FEEL …

Read full complaint

RECALL 96 V 071 00/ELECTRICAL SYSTEM IGNITION: VEHICLE EXPERIENCING PROBLEM WITH IGNITION SWITCH FAILING TO OPERATE/ WILL NOT TURN ON. HAD TO DISCONNECT SWITCH AND HOT WIRE TO GET VEHICLE TO START. MANUFACTURER NOTIFIED, AND INFORMED CONSUMER THAT THEY COULD NOT LOCATE VIN SYSTEM. ASKING NHTSA TO HELP IN THIS MATTER. FEEL FREE TO PROVIDE ANY FURTHER DETAILS ON THIS PROBLEM. *AK

NHTSA ODI #889980

Mileage unknown · Jun 4, 2001
Tires

TREAD STARTED COMING OFF TIRE. REMOVED BEFORE BLOWOUT. LOCAL DEALER CONTACTED BUT "NO RECALL PROGRAM ON THAT SIZE". SEEMS TO BE SAME PROBLEM AS WITH 235/75/R15'S. *AK (TIRESIZE: 235/85/R16)( DOT NUMBER: TIRE SIZE: 235/85/R16 )

NHTSA ODI #746390

Mileage unknown · May 18, 2001
Tires

CONSUMER WAS TRAVELING 58-59MPH AND PASSENGER'S REAR TIRE TREAD SEPARATED. ONLY WARNING WAS THAT VEHICLE SWAYED FORM SIDE TO SIDE. TREAD WAS HITTING REAR OF WHEEL WELL AND RUNNING WELL. VEHICLE HAD OVER $2407.00 WORTH OF DAMAGE. TIRE SIZE P265/75R16, APRROXIMATELY 3500, AFTERMARKET TIRES.*AK *JB

NHTSA ODI #888588

Mileage unknown · Mar 7, 2001
Engine And Engine CoolingFire

CONSUMER WENT TO START VEHICLE , SMOKE STARTED TO COME OUT OF ENGINE COMPARTMENT , FILLED TRUCK WITH BAD BURNING SMELL, SHUT OFF ENGINE AND NOTICED INSULATION HAS COMPLETELY MELTED ,WIRES OFF ENGINE,A MAJOR CONNECTOR WAS ALSO BURNED, BUT NO FUSES WERE BLOWN. CONSUMER HAS ALREADY FILED COMPLAINT EVOQ#861040 BUT SAME DEFECT RECOO…

Read full complaint

CONSUMER WENT TO START VEHICLE , SMOKE STARTED TO COME OUT OF ENGINE COMPARTMENT , FILLED TRUCK WITH BAD BURNING SMELL, SHUT OFF ENGINE AND NOTICED INSULATION HAS COMPLETELY MELTED ,WIRES OFF ENGINE,A MAJOR CONNECTOR WAS ALSO BURNED, BUT NO FUSES WERE BLOWN. CONSUMER HAS ALREADY FILED COMPLAINT EVOQ#861040 BUT SAME DEFECT RECOOCURRED. SERVICE MANAGER AT DEALER CLAIMED DEFECT WAS NOT UNUSUAL AND WAS AWARE OF DEFECT.*AK THE CONSUMER BELIEVES THE PROBLEM WA NOT ELECTRICAL. *YH

NHTSA ODI #882338

Mileage unknown · Feb 27, 2001
Fuel System, Gasoline

WHEN SWITCHING FROM FRONT TANK TO REAR TANK THERE IS A LEAK PRESENT DUE TO FUEL LINE CLAMP THAT DOES NOT HOLD LINES SECURE. DEALER HAS NOT SEEN VEHICLE. *AK

NHTSA ODI #881546

Mileage unknown · Feb 14, 2001
TiresCrash

WHILE DRIVING, CONSUMER HEARD A LOUD NOISE AND PULLED OFF TO SIDE OF ROAD, FOUND FRONT REAR FIRESTONE TIRE HAD EXPERIENCED TREAD SEPARATIONH, TIRE SIZE P235/85R16, DOT VN0RTWT241. *SLC

NHTSA ODI #880582

Mileage unknown · Feb 9, 2001
Fuel System, Gasoline

EA 99032 FUEL TANK IS OVERFLOWING REGARDLESS OF WHICH TANK IS ON. FUEL IS STILL BEING USED BY BOTH TANKS. *AK REAR TANK OVERFLOWED WHILE VEHICLE WAS PARKED IN DRIVEWAY.. *SLC

NHTSA ODI #880255

Mileage unknown · Jan 21, 2001
Tires

RIGHT REAR TIRE SEPARATED THEN BLEW, THROWING THE TIRE CAP AROUND ,DAMAGING FENDER, SHOCK, MUFFLER AND WHEEL WELL SUPPORTS AS WELL AS OUR NERVES TRYING TO MAINTAIN CONTROL.*AK (DOT NUMBER: ? TIRESIZE: 255/85R16)

NHTSA ODI #739728

Mileage unknown · Jan 16, 2001
Seat Belts

THE REUSE OF THE SEATBELTS INSTALLED BY FORD AFTER EMERGENCY USE IS NOT CLEAR. INSURANCE COMPANY WAS NOT EVEN AWARE OF THIS SITUATION. THE SEATBELTS INSTALLED BY FORD MUST BE DEALER INSPECTED AFTER EMERGENCY USE . THESE SEATBELTS ARE DESIGNED FOR A ONE SHOT USE IN COLLISIONS OR MAJOR BRAKING. HOW MANY PEOPLE ARE DRIVING AROUND …

Read full complaint

THE REUSE OF THE SEATBELTS INSTALLED BY FORD AFTER EMERGENCY USE IS NOT CLEAR. INSURANCE COMPANY WAS NOT EVEN AWARE OF THIS SITUATION. THE SEATBELTS INSTALLED BY FORD MUST BE DEALER INSPECTED AFTER EMERGENCY USE . THESE SEATBELTS ARE DESIGNED FOR A ONE SHOT USE IN COLLISIONS OR MAJOR BRAKING. HOW MANY PEOPLE ARE DRIVING AROUND UNAWARE THAT THEIR SEATBELTS ARE SUBJECT TO FAILURE ,BECAUSE OF A MAJOR USE EARLIER? THERE IS THE CONSEPTION THAT IF A SEATBELT GOES AROUND AND HOOKS THE PERSON IS SAFE ,FALSE,FALSE,FALSE....... THEY ARE NOT DESIGNED FOR MULTIPLE USES. FORD DEALER INFORMED ME ON 01/16/01 THEY ARE A NON SERVICEABLE ITEM AND MUST BE REPLACED . THANK YOU WILLIAM SULLIVAN. *AK

NHTSA ODI #739475

Official recalls

5

96V071000 · Electrical System:ignition

Apr 25, 1996

THE IGNITION SWITCH COULD EXPERIENCE AN INTERNAL SHORT CIRCUIT.

Consequence & remedy

Consequence: THIS CONDITION COULD CAUSE OVERHEATING, SMOKE, AND POSSIBLY FIRE IN THE STEERING COLUMN AREA OF THE VEHICLE.

Remedy: DEALERS WILL REPLACE THE IGNITION SWITCH.

94V040000 · Fuel System, Gasoline:delivery:hoses, Lines/piping, And Fittings

Feb 23, 1994

THE STEEL FUEL RETURN TUBES THAT CONNECT THE FRAME FUEL RETURN LINES WITH THE ENGINE FUEL RAIL CAN CONTACT THE PINCH WELD FLANGE CONNECTING THE DASH PANEL TO THE FLOOR PAN. CONTINUED CONTACT LEADS TO ABRASION OF THE STEEL FUEL RETURN TUBE AND EVENTUALLY RESULTS IN A FUEL LEAK.

Consequence & remedy

Consequence: ABRASION OF THE STEEL TUBE WALL THAT EVENTUALLY CAUSES A FUEL LEAK MAY RESULT IN A FIRE, IF A SOURCE OF IGNITION IS PRESENT.

Remedy: FORD DEALERS WILL REPLACE THE FUEL RETURN TUBES WITH FLEXIBLE STAINLESS STEEL BRAIDED/TEFLON TUBES. DEALERS WILL ALSO INSPECT THE FUEL SUPPLY TUBES.

93V125000 · Fuel System, Gasoline:storage:tank Assembly

Aug 2, 1993

A MALFUNCTIONING CHECK VALVE WITHIN THE FUEL PUMP ASSEMBLY CAUSES A PORTION OF THE UNUSED FUEL FROM ONE TANK TO BE RETURNED TO THE SECOND TANK. WHEN THIS OCCURS, THE CAPACITY OF THE SECOND TANK CAN BE EXCEEDED, CAUSING FUEL SPILLAGE.

Consequence & remedy

Consequence: SPILLED FUEL CAN RESULT IN A FIRE WHEN EXPOSED TO ASOURCE OF IGNITION.

Remedy: REPLACEMENT OF THE FUEL PRESSURE REGULATOR AND INSTALLATION OF REDUNDANT CHECK VALVES.

93V066000 · Steering: Steering Wheel/handle Bar

Apr 27, 1993

KEYS ATTACHED TO THE KEY RING OF AN IGNITION KEY WHILE IT IS IN THE VEHICLE IGNITION CAN BECOME LODGED IN THE STEERING LOCK RECEIVER AS THE STEERING WHEEL IS BEING TURNED.

Consequence & remedy

Consequence: THE LODGED KEYS CAN CAUSE LOSS OF STEERING CONTROL, WHICHCAN RESULT IN AN ACCIDENT WHEN THE VEHICLE IS BEING USED ON THE HIGHWAY.

Remedy: A SHIELD WILL BE POSITIONED BETWEEN THE STEERING WHEEL AND THE IGNITION SWITCH AND HELD IN PLACE BY THE STEERING LOCK BAND.

92V026000 · Service Brakes, Hydraulic:foundation Components:drum:shoes/linings

Mar 3, 1992

A REVISED BRAKE LINING NOISE INSULATOR RESULTED IN A DECREASE IN THE THERMAL INSULATION BETWEEN THE BRAKE LINING AND THE FRONT BRAKE CALIPER PISTON. THIS CAUSED GREATER HEAT TRANSFER TO THE CALIPER PISTONS WITH THE POTENTIAL TO OVERHEAT THE BRAKE FLUID AND DIMINISH BRAKE EFFECTIVENESS DURING SEVERE BRAKING CONDITIONS.

Consequence & remedy

Consequence: INCREASED STOPPING DISTANCES AND INABLILITY TO HOLDVEHICLES ON A STEEP GRADE RESULTS IN INCREASED RISK OF ACCIDENT IN THE EVENT OFA SUDDEN STOP OR WHEN CONSTANT BRAKING IS NEEDED TO MANEUVER THROUGH AREAS WITHSTEEP GRADES.

Remedy: ADD SNAP-IN INSULATORS THAT ATTACH TO EACH OF THE FRONT BRAKE CALIPER PISTONS. IN ADDITION, VEHICLES WITH 7.5 L ENGINES WILL HAVE INSULATION ADDED TO THE ENGINE COMPARTMENT BRAKE LINES.

Model-level recall history does not show whether a particular VIN is affected or has received a repair. Check a VIN with NHTSA ↗

NHTSA investigations

11

EA99032 · Dual Fuel Tank Crossflow/leakage

Opened Nov 4, 1999 · Closed Dec 6, 2001

Status: closed (inferred from source dates) · Vehicle Speed Control:linkages

ON JULY 14, 1993 FORD FILED A DEFECT INFORMATION REPORT CONCERNING FUEL TANK CROSS FLOW LEAKAGE ON F-SERIES LIGHT TRUCKS AND CAB CHASSIS BUILT FROM JULY 22, 1989 THROUGH DECEMBER 17, 1992.THE REMEDY WAS TO REPLACE THE FUEL PRESSURE REGULATOR AND INSTALL A CHECK VALVE BETWEEN EACH FUEL SUPPLY LINE AND FUEL TANK (2) TO REPAIR THE SUPPLY SIDE FUEL CROSS FLOW PROBLEM (RECALL 93V-125).ODI OPENED RQ98-008 ON MAY 29, 1998 BECAUSE OF THE LARGE NUMBER OF ALLEGED REMEDY FAILURES AND REPORTS OF FUEL CROSS FLOW ON VEHICLES OUTSIDE OF THE RECALL POPULATION.BASED ONTHE INFORMATION RECEIVED FROM FORD ON AUGUST 11, SEPTEMBER 30, AND DECEMBER 15, 1998, AND THE INCREASING TREND OF REMEDY FAILURES AND OUT OF SCOPE CROSSFLOW REPORTS, ODI OPENED EA99-032 ON NOVEMBER 4, 1999.THE ATTACHED ENGINEERING ANALYSIS CLOSING REPORT FULLY DESCRIBES THE RESULTS OF THIS INVESTIGATION AND REASON FOR CLOSING.THE SUBJECT VEHICLES CAN EXPERIENCE FUEL TRANSFER FROM ONE TANK TO THE OTHER DUE TO MALFUNCTIONS IN THE FUEL SYSTEM.WHEN FUEL IS PUMPED OR RETURNED TO THE NON-OPERATING TANK (CROSS FLOW), THE CAPACITY OF THE NON-OPERATING TANK CAN BE EXCEEDED, CAUSING FUEL TO OVERFLOW PAST THE FILLER CAP, CREATING A FIRE POTENTIAL.

Additional source detail variants (2)

Vehicle Speed Control:linkages

ON JULY 14, 1993 FORD FILED A DEFECT INFORMATION REPORT CONCERNING FUEL TANK CROSS FLOW LEAKAGE ON F-SERIES LIGHT TRUCKS AND CAB CHASSIS BUILT FROM JULY 22, 1989 THROUGH DECEMBER 17, 1992.THE REMEDY WAS TO REPLACE THE FUEL PRESSURE REGULATOR AND INSTALL A CHECK VALVE BETWEEN EACH FUEL SUPPLY LINE AND FUEL TANK (2) TO REPAIR THE SUPPLY SIDE FUEL CROSS FLOW PROBLEM (RECALL 93V-125).ODI OPENED RQ98-008 ON MAY 29, 1998 BECAUSE OF THE LARGE NUMBER OF ALLEGED REMEDY FAILURES AND REPORTS OF FUEL CROSS FLOW ON VEHICLES OUTSIDE OF THE RECALL POPULATION.BASED ONTHE INFORMATION RECEIVED FROM FORD ON AUGUST 11, SEPTEMBER 30, AND DECEMBER 15, 1998, AND THE INCREASING TREND OF REMEDY FAILURES AND OUT OF SCOPE CROSSFLOW REPORTS, ODI OPENED EA99-032 ON NOVEMBER 4, 1999.THE ATTACHED ENGINEERING ANALYSIS CLOSING REPORT FULLY DESCRIBES THE RESULTS OF THIS INVESTIGATION AND REASON FOR CLOSING.THE SUBJECT VEHICLES CAN EXPERIENCE FUEL TRANSFER FROM ONE TANK TO THE OTHER DUE TO MALFUNCTIONS IN THE FUEL SYSTEM.WHEN FUEL IS PUMPED OR RETURNED TO THE NON-OPERATING TANK (CROSS FLOW), THE CAPACITY OF THE NON-OPERATING TANK CAN BE EXCEEDED, CAUSING FUEL TO OVERFLOW PAST THE FILLER CAP, CREATING A FIRE POTENTIAL.

Vehicle Speed Control:linkages

ON JULY 14, 1993 FORD FILED A DEFECT INFORMATION REPORT CONCERNING FUEL TANK CROSS FLOW LEAKAGE ON F-SERIES LIGHT TRUCKS AND CAB CHASSIS BUILT FROM JULY 22, 1989 THROUGH DECEMBER 17, 1992.THE REMEDY WAS TO REPLACE THE FUEL PRESSURE REGULATOR AND INSTALL A CHECK VALVE BETWEEN EACH FUEL SUPPLY LINE AND FUEL TANK (2) TO REPAIR THE SUPPLY SIDE FUEL CROSS FLOW PROBLEM (RECALL 93V-125).ODI OPENED RQ98-008 ON MAY 29, 1998 BECAUSE OF THE LARGE NUMBER OF ALLEGED REMEDY FAILURES AND REPORTS OF FUEL CROSS FLOW ON VEHICLES OUTSIDE OF THE RECALL POPULATION.BASED ONTHE INFORMATION RECEIVED FROM FORD ON AUGUST 11, SEPTEMBER 30, AND DECEMBER 15, 1998, AND THE INCREASING TREND OF REMEDY FAILURES AND OUT OF SCOPE CROSSFLOW REPORTS, ODI OPENED EA99-032 ON NOVEMBER 4, 1999.THE ATTACHED ENGINEERING ANALYSIS CLOSING REPORT FULLY DESCRIBES THE RESULTS OF THIS INVESTIGATION AND REASON FOR CLOSING.THE SUBJECT VEHICLES CAN EXPERIENCE FUEL TRANSFER FROM ONE TANK TO THE OTHER DUE TO MALFUNCTIONS IN THE FUEL SYSTEM.WHEN FUEL IS PUMPED OR RETURNED TO THE NON-OPERATING TANK (CROSS FLOW), THE CAPACITY OF THE NON-OPERATING TANK CAN BE EXCEEDED, CAUSING FUEL TO OVERFLOW PAST THE FILLER CAP, CREATING A FIRE POTENTIAL.

RQ98008 · Ford F-SERIES Dual Fuel Tank Leakage

Opened May 29, 1998 · Closed Nov 4, 1999

Status: closed (inferred from source dates) · Fuel System, Gasoline:storage:tank Assembly

THESE VEHICLES CAN EXPERIENCE FUEL TRANSFER FROM ONE TANK TO THE OTHER DUE TO A MALFUNCTIONING FUEL PUMP.FROM THE INFORMATION GATHERED TO DATE, IT APPEARS THAT THERE CAN BE MULTIPLE CAUSES AND/OR A COMBINATION OF CAUSES FOR FUEL CROSS FLOW AND THAT THE RECALL REMEDY MAY BE INADEQUATE.FURTHER INVESTIGATION IS NEEDED.THIS INVESTIGATION IS UPGRADED TO EA99-032.CLICK ON DOCUMENT SEARCH BUTTON FOR ADDITIONAL INFORMATION.

EA93022 · Idle Air Spd Ctrl Vlv Malf

Opened Jul 30, 1993 · Closed Aug 31, 1994

Status: closed (inferred from source dates) · Engine And Engine Cooling

There is no summary currently available

EA93014 · Alternator Belt Failure

Opened Jun 4, 1993 · Closed Jul 29, 1994

Status: closed (inferred from source dates) · Electrical System

There is no summary currently available

PE93010 · Idle Air Spd Ctrl Vlv Malf

Opened Mar 2, 1993 · Closed Jul 30, 1993

Status: closed (inferred from source dates) · Engine And Engine Cooling

There is no summary currently available

EA93001 · Fuel Expulsion

Opened Jan 7, 1993 · Closed Aug 20, 1993

Status: closed (inferred from source dates) · Vehicle Speed Control:linkages

There is no summary currently available

PE92077 · Fuel Expulsion

Opened Sep 9, 1992 · Closed Jan 7, 1993

Status: closed (inferred from source dates) · Vehicle Speed Control:linkages

There is no summary currently available

EA91044 · Loss Of Brake Effectivenes

Opened Oct 30, 1991 · Closed Oct 30, 1992

Status: closed (inferred from source dates) · Service Brakes, Hydraulic

===

EA91031 · Fuel Expulsion

Opened Jun 26, 1991 · Closed Nov 1, 1991

Status: closed (inferred from source dates) · Vehicle Speed Control:linkages

There is no summary currently available

PE91077 · Loss Of Brake Effectivenes

Opened May 23, 1991 · Closed Oct 31, 1991

Status: closed (inferred from source dates) · Service Brakes, Hydraulic

There is no summary currently available

PE91064 · Transmission Fluid Fires

Opened Apr 9, 1991 · Closed Jul 5, 1991

Status: closed (inferred from source dates) · Power Train

There is no summary currently available