← New search

1991 Ford F-250

Owner reports · Recalls · Investigations

Similar to other model years

Owner complaints for the 1991 Ford F-250 do not stand out strongly from the model-year median of 119.

About this comparison →

How this year compares

Owner complaints by model year

Other model years Selected year
Compare all F-250 years →

Counts vary with age, sales and reporting. They are not failure rates.

What owners reported most

All reported categories

Tap a category to read its complaints. One report may name several components.

When problems were reported

Mileage at the reported incident

Limited mileage data: 15 of 107 reports include usable mileage. There isn’t enough coverage to show a useful chart.

NHTSA’s mileage field refers to the reported incident, not necessarily the filing date. This shows report counts, not the likelihood of a failure.

What to inspect

Issues worth paying extra attention to based on owner reports.

  • Fuel System, Gasoline. Review the 26 owner reports in this category and discuss these concerns during a pre-purchase inspection. Read reports →
  • Service Brakes, Hydraulic. Review the 24 owner reports in this category and discuss these concerns during a pre-purchase inspection. Read reports →
  • Electrical System. Review the 15 owner reports in this category and discuss these concerns during a pre-purchase inspection. Read reports →

NHTSA owner reports · September 18, 2026 snapshot.

5 crash reports9 fire reports3 injury reports

Tires complaints

10 reports
Clear category filter
198,400 miles · May 28, 2009
Tires

DISCOVERER A/T TIRES SIZE LT265/75R16 CATASTROPHICALLY FAILED WHILE DRIVING AT HIGHWAY SPEED. TREAD COMPLETELY PEELED OFF. HAD ONLY BEEN DRIVING FOR 30 MINUTES AND OUTSIDE TEMPERATURE WAS 70 DEGREES F. TIRES HAD ABOUT 23,000 MILES ON THEM. 1-2 YEARS PREVIOUSLY, THE SAME TYPE TIRE ON OPPOSITE WHEEL DEVELOPED A BULGE IN THE SI…

Read full complaint

DISCOVERER A/T TIRES SIZE LT265/75R16 CATASTROPHICALLY FAILED WHILE DRIVING AT HIGHWAY SPEED. TREAD COMPLETELY PEELED OFF. HAD ONLY BEEN DRIVING FOR 30 MINUTES AND OUTSIDE TEMPERATURE WAS 70 DEGREES F. TIRES HAD ABOUT 23,000 MILES ON THEM. 1-2 YEARS PREVIOUSLY, THE SAME TYPE TIRE ON OPPOSITE WHEEL DEVELOPED A BULGE IN THE SIDEWALL AND HAD TO BE REPLACED. *TR

NHTSA ODI #10270248

10,800 miles · Nov 12, 2007
Tires

I HAD 2 FAILURES WITH THE FIRST ABOUT 9/21/07 AND THE SECOND 10/6/07. THE VEHICLE IS A 1991 F250 HD AND IS OCCASIONALLY USED TO HAUL A SLIDE-IN CAMPER. ON BOTH OCCASIONS I HAD THE CAMPER ON THE TRUCK, LOADING THE TRUCK TO NEAR THE RATED CAPACITY OF THE TIRES BUT NOT OVER TO MY KNOWLEDGE. IN BOTH INSTANCES THE TIRE PRESSURE WA…

Read full complaint

I HAD 2 FAILURES WITH THE FIRST ABOUT 9/21/07 AND THE SECOND 10/6/07. THE VEHICLE IS A 1991 F250 HD AND IS OCCASIONALLY USED TO HAUL A SLIDE-IN CAMPER. ON BOTH OCCASIONS I HAD THE CAMPER ON THE TRUCK, LOADING THE TRUCK TO NEAR THE RATED CAPACITY OF THE TIRES BUT NOT OVER TO MY KNOWLEDGE. IN BOTH INSTANCES THE TIRE PRESSURE WAS CHECKED BEFORE LEAVING THE HOUSE, WERE WE TRAVELING A MODERATE SPEED, ABOUT 55 MPH, AND IT WAS COOL. IN BOTH CASES I NOTICED A VIBRATION BUT BEFORE I COULD EFFECT A SUBSTANTIAL RESPONSE THE TIRE EXPLODED. THE TRUCK REMAINED IN CONTROL BUT THERE WAS SUBSTANTIAL DAMAGE TO THE TRUCK. THE TIRES WERE ON THE REAR SO THERE WAS DAMAGE TO BOTH SIDES. THE FIRST TIME I HAD THE TIRE REPLACED BY THE DEALER AND HE GAVE ME OVER A 50% CREDIT, REFLECTING THE AMOUNT OF TREAD LEFT ON THE TIRE. THE SECOND TIME I HAD THE TIRE REPLACED WITH A DIFFERENT BRAND AND KEPT THE OLD TIRE FOR INSPECTION. *TR

NHTSA ODI #10208696

Mileage unknown · Jun 4, 2001
Tires

TREAD STARTED COMING OFF TIRE. REMOVED BEFORE BLOWOUT. LOCAL DEALER CONTACTED BUT "NO RECALL PROGRAM ON THAT SIZE". SEEMS TO BE SAME PROBLEM AS WITH 235/75/R15'S. *AK (TIRESIZE: 235/85/R16)( DOT NUMBER: TIRE SIZE: 235/85/R16 )

NHTSA ODI #746390

Mileage unknown · May 18, 2001
Tires

CONSUMER WAS TRAVELING 58-59MPH AND PASSENGER'S REAR TIRE TREAD SEPARATED. ONLY WARNING WAS THAT VEHICLE SWAYED FORM SIDE TO SIDE. TREAD WAS HITTING REAR OF WHEEL WELL AND RUNNING WELL. VEHICLE HAD OVER $2407.00 WORTH OF DAMAGE. TIRE SIZE P265/75R16, APRROXIMATELY 3500, AFTERMARKET TIRES.*AK *JB

NHTSA ODI #888588

Mileage unknown · Feb 14, 2001
TiresCrash

WHILE DRIVING, CONSUMER HEARD A LOUD NOISE AND PULLED OFF TO SIDE OF ROAD, FOUND FRONT REAR FIRESTONE TIRE HAD EXPERIENCED TREAD SEPARATIONH, TIRE SIZE P235/85R16, DOT VN0RTWT241. *SLC

NHTSA ODI #880582

Mileage unknown · Jan 21, 2001
Tires

RIGHT REAR TIRE SEPARATED THEN BLEW, THROWING THE TIRE CAP AROUND ,DAMAGING FENDER, SHOCK, MUFFLER AND WHEEL WELL SUPPORTS AS WELL AS OUR NERVES TRYING TO MAINTAIN CONTROL.*AK (DOT NUMBER: ? TIRESIZE: 255/85R16)

NHTSA ODI #739728

Mileage unknown · Nov 1, 2000
Tires

LEFT REAR TIRE BLEWOUT AND SHREDDED CAUSING DAMAGE TO THE INNER FENDER, TIRES SHOWED SIGNS OF SEPARATION OF THE TREAD (FIRESTONE STEELTEX LT23585R16). NLM

NHTSA ODI #556520

Mileage unknown · Oct 14, 2000
Electrical SystemService Brakes, HydraulicTires

FRONT TIRE WEARING UNEVENLY EVEM WITH RECENT ALINEMENT-TOOK TO AMERICAS TIRE CO. FOR ROTATION AND WAS TOLD TIRE HAD FLAT SPOTS AND ROTATION WOULD NOT HELP-TIRE DEFECTIVE. IS THIS TIRE ON THE RECALL? (TIRESIZE: LT21585R16)( DOT NUMBER: TIRE SIZE: LT21585R16 )

NHTSA ODI #734313

22,466 miles · Oct 14, 2000
Tires

FRONT TIRE WEARING UNEVENLY EVEN WITH RECENT ALIGNMENT. TOOK TO AMERICAS TIRE CO. FOR ROTATION AND WAS TOLD TIRE HAD FLAT SPOTS AND ROTATION WOULD NOT HELP-TIRE DEFECTIVE. IS THIS TIRE ON THE RECALL? ****DIMSII IVOQ ENTRY AFTER 12/12/02 CUT-OVER TO ARTEMIS****73413

NHTSA ODI #10009861

Mileage unknown · Oct 10, 2000
Tires

CRUISING AT A SPEED OF 65MPH., TIRE BLEW (RUBBER PEELED OFF TIRE EXPOSING STEEL BELT) CAUSING TRUCK DAMAGE TO OUTER PANEL REAR BRACE, RT MOLDING REAR ADHESIVE TYPE, RT OUTER PANEL REPAIRED AND REFINISHED, REPLACED RT MOLDING WHEEL OPENING, REPLACED RUNNING BOARD, TAIL PIPE, RT RR WHEEL LINER FRT., RT RR WHEEL LINER RR., REAR …

Read full complaint

CRUISING AT A SPEED OF 65MPH., TIRE BLEW (RUBBER PEELED OFF TIRE EXPOSING STEEL BELT) CAUSING TRUCK DAMAGE TO OUTER PANEL REAR BRACE, RT MOLDING REAR ADHESIVE TYPE, RT OUTER PANEL REPAIRED AND REFINISHED, REPLACED RT MOLDING WHEEL OPENING, REPLACED RUNNING BOARD, TAIL PIPE, RT RR WHEEL LINER FRT., RT RR WHEEL LINER RR., REAR MUD GUARDS AND PAINTING OF ALL REPLACED PARTS. ALSO, REPAIRED EMERGENCY BRAKE. PLUS ALL LABOR COSTS. TOTAL COST OF REPAIR $2,054.00, PAID BY SAFECO INSURANCE CLAIM # 24A001680380 1-800-433-1058. TOTAL COST OF TIRE REPLACEMENT $105.00 PLUS MN TAX. REPLACED WITH 4 NEW FIRESTONE STEELTEX DR4S, TUBLPS. 2358R16. LOAD RANGE E. NOW UNDER INVESTIGATION. PURCHASED AT FIRESTONE TIRE AND SERVICE CENTER 2100 N SNELLING ROSEVILLE MN 55113 NOTE: WE ARE NOW DRIVING ON THESE NEW REPLACED TIRES AND ARE VERY CONCERNED FOR OUR SAFETY. PLEASE ADVICE (DOT NUMBER: 8XOR65C TIRESIZE: 16 INCH)

NHTSA ODI #733888

Official recalls

5

96V071000 · Electrical System:ignition

Apr 25, 1996

THE IGNITION SWITCH COULD EXPERIENCE AN INTERNAL SHORT CIRCUIT.

Consequence & remedy

Consequence: THIS CONDITION COULD CAUSE OVERHEATING, SMOKE, AND POSSIBLY FIRE IN THE STEERING COLUMN AREA OF THE VEHICLE.

Remedy: DEALERS WILL REPLACE THE IGNITION SWITCH.

94V040000 · Fuel System, Gasoline:delivery:hoses, Lines/piping, And Fittings

Feb 23, 1994

THE STEEL FUEL RETURN TUBES THAT CONNECT THE FRAME FUEL RETURN LINES WITH THE ENGINE FUEL RAIL CAN CONTACT THE PINCH WELD FLANGE CONNECTING THE DASH PANEL TO THE FLOOR PAN. CONTINUED CONTACT LEADS TO ABRASION OF THE STEEL FUEL RETURN TUBE AND EVENTUALLY RESULTS IN A FUEL LEAK.

Consequence & remedy

Consequence: ABRASION OF THE STEEL TUBE WALL THAT EVENTUALLY CAUSES A FUEL LEAK MAY RESULT IN A FIRE, IF A SOURCE OF IGNITION IS PRESENT.

Remedy: FORD DEALERS WILL REPLACE THE FUEL RETURN TUBES WITH FLEXIBLE STAINLESS STEEL BRAIDED/TEFLON TUBES. DEALERS WILL ALSO INSPECT THE FUEL SUPPLY TUBES.

93V125000 · Fuel System, Gasoline:storage:tank Assembly

Aug 2, 1993

A MALFUNCTIONING CHECK VALVE WITHIN THE FUEL PUMP ASSEMBLY CAUSES A PORTION OF THE UNUSED FUEL FROM ONE TANK TO BE RETURNED TO THE SECOND TANK. WHEN THIS OCCURS, THE CAPACITY OF THE SECOND TANK CAN BE EXCEEDED, CAUSING FUEL SPILLAGE.

Consequence & remedy

Consequence: SPILLED FUEL CAN RESULT IN A FIRE WHEN EXPOSED TO ASOURCE OF IGNITION.

Remedy: REPLACEMENT OF THE FUEL PRESSURE REGULATOR AND INSTALLATION OF REDUNDANT CHECK VALVES.

93V066000 · Steering: Steering Wheel/handle Bar

Apr 27, 1993

KEYS ATTACHED TO THE KEY RING OF AN IGNITION KEY WHILE IT IS IN THE VEHICLE IGNITION CAN BECOME LODGED IN THE STEERING LOCK RECEIVER AS THE STEERING WHEEL IS BEING TURNED.

Consequence & remedy

Consequence: THE LODGED KEYS CAN CAUSE LOSS OF STEERING CONTROL, WHICHCAN RESULT IN AN ACCIDENT WHEN THE VEHICLE IS BEING USED ON THE HIGHWAY.

Remedy: A SHIELD WILL BE POSITIONED BETWEEN THE STEERING WHEEL AND THE IGNITION SWITCH AND HELD IN PLACE BY THE STEERING LOCK BAND.

92V026000 · Service Brakes, Hydraulic:foundation Components:drum:shoes/linings

Mar 3, 1992

A REVISED BRAKE LINING NOISE INSULATOR RESULTED IN A DECREASE IN THE THERMAL INSULATION BETWEEN THE BRAKE LINING AND THE FRONT BRAKE CALIPER PISTON. THIS CAUSED GREATER HEAT TRANSFER TO THE CALIPER PISTONS WITH THE POTENTIAL TO OVERHEAT THE BRAKE FLUID AND DIMINISH BRAKE EFFECTIVENESS DURING SEVERE BRAKING CONDITIONS.

Consequence & remedy

Consequence: INCREASED STOPPING DISTANCES AND INABLILITY TO HOLDVEHICLES ON A STEEP GRADE RESULTS IN INCREASED RISK OF ACCIDENT IN THE EVENT OFA SUDDEN STOP OR WHEN CONSTANT BRAKING IS NEEDED TO MANEUVER THROUGH AREAS WITHSTEEP GRADES.

Remedy: ADD SNAP-IN INSULATORS THAT ATTACH TO EACH OF THE FRONT BRAKE CALIPER PISTONS. IN ADDITION, VEHICLES WITH 7.5 L ENGINES WILL HAVE INSULATION ADDED TO THE ENGINE COMPARTMENT BRAKE LINES.

Model-level recall history does not show whether a particular VIN is affected or has received a repair. Check a VIN with NHTSA ↗

NHTSA investigations

11

EA99032 · Dual Fuel Tank Crossflow/leakage

Opened Nov 4, 1999 · Closed Dec 6, 2001

Status: closed (inferred from source dates) · Vehicle Speed Control:linkages

ON JULY 14, 1993 FORD FILED A DEFECT INFORMATION REPORT CONCERNING FUEL TANK CROSS FLOW LEAKAGE ON F-SERIES LIGHT TRUCKS AND CAB CHASSIS BUILT FROM JULY 22, 1989 THROUGH DECEMBER 17, 1992.THE REMEDY WAS TO REPLACE THE FUEL PRESSURE REGULATOR AND INSTALL A CHECK VALVE BETWEEN EACH FUEL SUPPLY LINE AND FUEL TANK (2) TO REPAIR THE SUPPLY SIDE FUEL CROSS FLOW PROBLEM (RECALL 93V-125).ODI OPENED RQ98-008 ON MAY 29, 1998 BECAUSE OF THE LARGE NUMBER OF ALLEGED REMEDY FAILURES AND REPORTS OF FUEL CROSS FLOW ON VEHICLES OUTSIDE OF THE RECALL POPULATION.BASED ONTHE INFORMATION RECEIVED FROM FORD ON AUGUST 11, SEPTEMBER 30, AND DECEMBER 15, 1998, AND THE INCREASING TREND OF REMEDY FAILURES AND OUT OF SCOPE CROSSFLOW REPORTS, ODI OPENED EA99-032 ON NOVEMBER 4, 1999.THE ATTACHED ENGINEERING ANALYSIS CLOSING REPORT FULLY DESCRIBES THE RESULTS OF THIS INVESTIGATION AND REASON FOR CLOSING.THE SUBJECT VEHICLES CAN EXPERIENCE FUEL TRANSFER FROM ONE TANK TO THE OTHER DUE TO MALFUNCTIONS IN THE FUEL SYSTEM.WHEN FUEL IS PUMPED OR RETURNED TO THE NON-OPERATING TANK (CROSS FLOW), THE CAPACITY OF THE NON-OPERATING TANK CAN BE EXCEEDED, CAUSING FUEL TO OVERFLOW PAST THE FILLER CAP, CREATING A FIRE POTENTIAL.

Additional source detail variants (2)

Vehicle Speed Control:linkages

ON JULY 14, 1993 FORD FILED A DEFECT INFORMATION REPORT CONCERNING FUEL TANK CROSS FLOW LEAKAGE ON F-SERIES LIGHT TRUCKS AND CAB CHASSIS BUILT FROM JULY 22, 1989 THROUGH DECEMBER 17, 1992.THE REMEDY WAS TO REPLACE THE FUEL PRESSURE REGULATOR AND INSTALL A CHECK VALVE BETWEEN EACH FUEL SUPPLY LINE AND FUEL TANK (2) TO REPAIR THE SUPPLY SIDE FUEL CROSS FLOW PROBLEM (RECALL 93V-125).ODI OPENED RQ98-008 ON MAY 29, 1998 BECAUSE OF THE LARGE NUMBER OF ALLEGED REMEDY FAILURES AND REPORTS OF FUEL CROSS FLOW ON VEHICLES OUTSIDE OF THE RECALL POPULATION.BASED ONTHE INFORMATION RECEIVED FROM FORD ON AUGUST 11, SEPTEMBER 30, AND DECEMBER 15, 1998, AND THE INCREASING TREND OF REMEDY FAILURES AND OUT OF SCOPE CROSSFLOW REPORTS, ODI OPENED EA99-032 ON NOVEMBER 4, 1999.THE ATTACHED ENGINEERING ANALYSIS CLOSING REPORT FULLY DESCRIBES THE RESULTS OF THIS INVESTIGATION AND REASON FOR CLOSING.THE SUBJECT VEHICLES CAN EXPERIENCE FUEL TRANSFER FROM ONE TANK TO THE OTHER DUE TO MALFUNCTIONS IN THE FUEL SYSTEM.WHEN FUEL IS PUMPED OR RETURNED TO THE NON-OPERATING TANK (CROSS FLOW), THE CAPACITY OF THE NON-OPERATING TANK CAN BE EXCEEDED, CAUSING FUEL TO OVERFLOW PAST THE FILLER CAP, CREATING A FIRE POTENTIAL.

Vehicle Speed Control:linkages

ON JULY 14, 1993 FORD FILED A DEFECT INFORMATION REPORT CONCERNING FUEL TANK CROSS FLOW LEAKAGE ON F-SERIES LIGHT TRUCKS AND CAB CHASSIS BUILT FROM JULY 22, 1989 THROUGH DECEMBER 17, 1992.THE REMEDY WAS TO REPLACE THE FUEL PRESSURE REGULATOR AND INSTALL A CHECK VALVE BETWEEN EACH FUEL SUPPLY LINE AND FUEL TANK (2) TO REPAIR THE SUPPLY SIDE FUEL CROSS FLOW PROBLEM (RECALL 93V-125).ODI OPENED RQ98-008 ON MAY 29, 1998 BECAUSE OF THE LARGE NUMBER OF ALLEGED REMEDY FAILURES AND REPORTS OF FUEL CROSS FLOW ON VEHICLES OUTSIDE OF THE RECALL POPULATION.BASED ONTHE INFORMATION RECEIVED FROM FORD ON AUGUST 11, SEPTEMBER 30, AND DECEMBER 15, 1998, AND THE INCREASING TREND OF REMEDY FAILURES AND OUT OF SCOPE CROSSFLOW REPORTS, ODI OPENED EA99-032 ON NOVEMBER 4, 1999.THE ATTACHED ENGINEERING ANALYSIS CLOSING REPORT FULLY DESCRIBES THE RESULTS OF THIS INVESTIGATION AND REASON FOR CLOSING.THE SUBJECT VEHICLES CAN EXPERIENCE FUEL TRANSFER FROM ONE TANK TO THE OTHER DUE TO MALFUNCTIONS IN THE FUEL SYSTEM.WHEN FUEL IS PUMPED OR RETURNED TO THE NON-OPERATING TANK (CROSS FLOW), THE CAPACITY OF THE NON-OPERATING TANK CAN BE EXCEEDED, CAUSING FUEL TO OVERFLOW PAST THE FILLER CAP, CREATING A FIRE POTENTIAL.

RQ98008 · Ford F-SERIES Dual Fuel Tank Leakage

Opened May 29, 1998 · Closed Nov 4, 1999

Status: closed (inferred from source dates) · Fuel System, Gasoline:storage:tank Assembly

THESE VEHICLES CAN EXPERIENCE FUEL TRANSFER FROM ONE TANK TO THE OTHER DUE TO A MALFUNCTIONING FUEL PUMP.FROM THE INFORMATION GATHERED TO DATE, IT APPEARS THAT THERE CAN BE MULTIPLE CAUSES AND/OR A COMBINATION OF CAUSES FOR FUEL CROSS FLOW AND THAT THE RECALL REMEDY MAY BE INADEQUATE.FURTHER INVESTIGATION IS NEEDED.THIS INVESTIGATION IS UPGRADED TO EA99-032.CLICK ON DOCUMENT SEARCH BUTTON FOR ADDITIONAL INFORMATION.

EA93022 · Idle Air Spd Ctrl Vlv Malf

Opened Jul 30, 1993 · Closed Aug 31, 1994

Status: closed (inferred from source dates) · Engine And Engine Cooling

There is no summary currently available

EA93014 · Alternator Belt Failure

Opened Jun 4, 1993 · Closed Jul 29, 1994

Status: closed (inferred from source dates) · Electrical System

There is no summary currently available

PE93010 · Idle Air Spd Ctrl Vlv Malf

Opened Mar 2, 1993 · Closed Jul 30, 1993

Status: closed (inferred from source dates) · Engine And Engine Cooling

There is no summary currently available

EA93001 · Fuel Expulsion

Opened Jan 7, 1993 · Closed Aug 20, 1993

Status: closed (inferred from source dates) · Vehicle Speed Control:linkages

There is no summary currently available

PE92077 · Fuel Expulsion

Opened Sep 9, 1992 · Closed Jan 7, 1993

Status: closed (inferred from source dates) · Vehicle Speed Control:linkages

There is no summary currently available

EA91044 · Loss Of Brake Effectivenes

Opened Oct 30, 1991 · Closed Oct 30, 1992

Status: closed (inferred from source dates) · Service Brakes, Hydraulic

===

EA91031 · Fuel Expulsion

Opened Jun 26, 1991 · Closed Nov 1, 1991

Status: closed (inferred from source dates) · Vehicle Speed Control:linkages

There is no summary currently available

PE91077 · Loss Of Brake Effectivenes

Opened May 23, 1991 · Closed Oct 31, 1991

Status: closed (inferred from source dates) · Service Brakes, Hydraulic

There is no summary currently available

PE91064 · Transmission Fluid Fires

Opened Apr 9, 1991 · Closed Jul 5, 1991

Status: closed (inferred from source dates) · Power Train

There is no summary currently available