FUEL IS BEING TRANSFERRED FROM ONE TANK TO ANOTHER WHILE VEHICLE IS IN OPERATION. CONSUMER TOOK VEHICLE TO DEALERSHIP THAT INFORMED CONSUMER THAT REPAIR WORK FOR RECALL 93V125000 HAD PREVIOUD NO RECORD OF TAKING VEHICLE IN FOR THIS PROBLEM. PLEASE PROVIDE ANY ADDITIONAL INFORMATION/ATTACHMENTS.*AK
1992 Ford F-150
Owner reports · Recalls · Investigations
Similar to other model years
Owner complaints for the 1992 Ford F-150 do not stand out strongly from the model-year median of 676.
About this comparison →How this year compares
Owner complaints by model year
Compare all F-150 years →Counts vary with age, sales and reporting. They are not failure rates.
What owners reported most
All reported categories
Tap a category to read its complaints. One report may name several components.
When problems were reported
Mileage at the reported incident
Limited mileage data: 49 of 470 reports include usable mileage. There isn’t enough coverage to show a useful chart.
NHTSA’s mileage field refers to the reported incident, not necessarily the filing date. This shows report counts, not the likelihood of a failure.
What to inspect
Issues worth paying extra attention to based on owner reports.
- Fuel System, Gasoline. Review the 231 owner reports in this category and discuss these concerns during a pre-purchase inspection. Read reports →
- Electrical System. Review the 48 owner reports in this category and discuss these concerns during a pre-purchase inspection. Read reports →
- Engine And Engine Cooling. Review the 37 owner reports in this category and discuss these concerns during a pre-purchase inspection. Read reports →
NHTSA owner reports · September 18, 2026 snapshot.
What owners actually said
470 reportsTHIS VEHICLE IS EXPERIENCING SAME DEFECT AS DESCRIBED IN NHTSA RECALL CAMPAIGN 93V125000. HOWEVER, DEALERSHIP INFORMED CONSUMER THAT THIS VEHICLE WAS NOT INCLUDED IN RECALL DUE TO VIN. *AK
CONSUMER'S VEHICLE ISN'T PART OF RECALL 93V125000/ MANUFACTURER'S RECALL 93S68 ALTHOUGH IT HAS SAME PROBLEM AS STATED IN RECALL. CONSUMER HAS DUAL TANKS, AND MODULES BETWEEN ALLOW GAS TO GO TO BACK WHICH CAUSES FUEL TO OVERFLOW. CONSUMER IS SECOND OWNER, AND DEALER IS DENYING RECALL REPAIRS DUE TO VIN. *AK
CONSUMER WAS TRAVELING 45MPH ON HIGHWAY AND ANOTHER VEHICLE FLAGGED HIM DOWN THAT HE WAS LEAKING FUEL FROM UNDERNEATH VEHICLE.*AK
CONSUMER HAD CONTACTED DEALER IN REFERENCE TO RECALLS 94 V 169 000 AND 93 V 125 000. CONSUMER BELIEVED RECALL WORK WAS NOT DONE CORRECTLY AS FUEL TANK WAS LEAKING. DEALER BOB BELL FORD 7125 RICHIE HWY. GLEN BURNIE, MD. 410-766-3600. *AK THE DEALER FAILED TO REMOVE THE LEAKING FUEL TANK, AND THE CONSUMER STATED THAT THE …
Read full complaint
CONSUMER HAD CONTACTED DEALER IN REFERENCE TO RECALLS 94 V 169 000 AND 93 V 125 000. CONSUMER BELIEVED RECALL WORK WAS NOT DONE CORRECTLY AS FUEL TANK WAS LEAKING. DEALER BOB BELL FORD 7125 RICHIE HWY. GLEN BURNIE, MD. 410-766-3600. *AK THE DEALER FAILED TO REMOVE THE LEAKING FUEL TANK, AND THE CONSUMER STATED THAT THE PROBLEM WAS DANGEROUS UNLESS ACTION WAS TAKEN. *YH
AFTER FILLING UP FUEL TANK FUEL GAUGE WILL SHOW ON DASHBOARD THAT TANK IS EMPTY.*AK
AFTER FILLING UP TANKS AND DRIVING DOWN ROAD COULD EXPERIENCE A LEAKAGE OF FUEL WHERE BOTH TANKS HAD TO BE REPLACED, INCLUDING DUAL TANKS SWITCH.*AK
RECALL 93V125000/ MANUFACTURER'S RECALL 93S68; FUEL WAS LEAKING FROM TANK PERIODICALLY. LATELY VEHICLE WAS STARTING TO LEAK MORE FREQUENTLY. CONSUMER WAS ON A ROAD TRIP AND FUEL WAS LEAKING FROM TANK CONSISTENTLY. CONSUMER WILL CONTACT DEALER TO SEE IF ANYTHING COULD BE DONE.*AK CONSUMER STATES VEHICLE HAD LEAKED FUEL I…
Read full complaint
RECALL 93V125000/ MANUFACTURER'S RECALL 93S68; FUEL WAS LEAKING FROM TANK PERIODICALLY. LATELY VEHICLE WAS STARTING TO LEAK MORE FREQUENTLY. CONSUMER WAS ON A ROAD TRIP AND FUEL WAS LEAKING FROM TANK CONSISTENTLY. CONSUMER WILL CONTACT DEALER TO SEE IF ANYTHING COULD BE DONE.*AK CONSUMER STATES VEHICLE HAD LEAKED FUEL IN PAST, HOWEVER THE CAUSE WAS NEVER DETERMINED. *SLC
EA99032; DUAL GAS TANK , FUEL IS TRANSFERRING FROM FRONT TANK TO REAR TANK DURING NORMAL OPERATION, CAUSING REAR TANK TO FILL ABNORMALLY, AND SPILL THROUGH GAS PIPE. RECALL 93V125000 REPAIRS WERE DONE, BUT DEFECT REOCCURRED. *AK DEALER STATED THAT CHECK VALVES HAD BEEN INSTALLED ON FUEL LINE CAUSING CHECK ENGINE LIGHT TO ILLUM…
Read full complaint
EA99032; DUAL GAS TANK , FUEL IS TRANSFERRING FROM FRONT TANK TO REAR TANK DURING NORMAL OPERATION, CAUSING REAR TANK TO FILL ABNORMALLY, AND SPILL THROUGH GAS PIPE. RECALL 93V125000 REPAIRS WERE DONE, BUT DEFECT REOCCURRED. *AK DEALER STATED THAT CHECK VALVES HAD BEEN INSTALLED ON FUEL LINE CAUSING CHECK ENGINE LIGHT TO ILLUMINATE. *SLC
93 V 125 000/FUEL TANK ASSEMBLY: A PORTION OF THE UNUSED FUEL FROM ONE TANK WAS RETURNED TO SECOND TANK. WHEN OCCURRED, SECOND TANK EXCEEDED ITS LIMIT, CAUSING FUEL SPILLAGES. SPILLED FUEL CAN RESULT IN A FIRE WHEN EXPOSED TO A SOURCE OF IGNITION. REPAIRS WERE DONE IN OCT 1994, AND PROBLEM HAS REOCCURRED. DEALER/ MANUFACTUR…
Read full complaint
93 V 125 000/FUEL TANK ASSEMBLY: A PORTION OF THE UNUSED FUEL FROM ONE TANK WAS RETURNED TO SECOND TANK. WHEN OCCURRED, SECOND TANK EXCEEDED ITS LIMIT, CAUSING FUEL SPILLAGES. SPILLED FUEL CAN RESULT IN A FIRE WHEN EXPOSED TO A SOURCE OF IGNITION. REPAIRS WERE DONE IN OCT 1994, AND PROBLEM HAS REOCCURRED. DEALER/ MANUFACTURER WERE NOTIFIED, AND WERE UNWILLING TO ASSIST IN THIS MATTER. FEEL FREE TO PROVIDE ANY FURTHER DETAILS ON THIS MATTER . *AK
Official recalls
394V169001 · Parking Brake:conventional
Sep 7, 1994
THE PARKING BRAKE CONTROL SELF-ADJUST PAWL DOES NOT LINE UP PROPERLY WITH THE SELF-ADJUST RACHET CAUSING THE PAWL TO SLIP OVER ONE OR MORE TEETH IN THE RACHET.
Consequence & remedy
Consequence: WHEN THE ABOVE OCCURS, IT CAN RESULT IN PARKING BRAKE SYSTEM INEFFECTIVENESS. THE PARKING BRAKE WILL NOT HOLD THE VEHICLE, CAUSING THE VEHICLE TO ROLL FREELY, IF THE TRANSMISSION IS NOT LEFT IN GEAR.
Remedy: A WEDGE WILL BE INSTALLED WHICH WILL SERVE TO LOCK THE PARKING BRAKE SELF-ADJUST MECHANISM PAWL INTO ENGAGEMENT WITH THE RACHET. ALSO, OWNERS WILL BE ADVISED TO RELEASE AND REAPPLY THE PARKING BRAKE WHENEVER TOOTH SKIP OCCURS AND WILL BE REMINDED TO ALWAYS TURN OFF THE ENGINE AND LEAVE THE VEHICLE IN GEAR WHEN THE VEHICLE IS PARKED.
93V125000 · Fuel System, Gasoline:storage:tank Assembly
Aug 2, 1993
A MALFUNCTIONING CHECK VALVE WITHIN THE FUEL PUMP ASSEMBLY CAUSES A PORTION OF THE UNUSED FUEL FROM ONE TANK TO BE RETURNED TO THE SECOND TANK. WHEN THIS OCCURS, THE CAPACITY OF THE SECOND TANK CAN BE EXCEEDED, CAUSING FUEL SPILLAGE.
Consequence & remedy
Consequence: SPILLED FUEL CAN RESULT IN A FIRE WHEN EXPOSED TO ASOURCE OF IGNITION.
Remedy: REPLACEMENT OF THE FUEL PRESSURE REGULATOR AND INSTALLATION OF REDUNDANT CHECK VALVES.
92V006000 · Structure:body:door
Jan 14, 1992
WATER CAN ENTER THE DOOR LATCH RELEASE CABLE. IF THE VEHICLE IS OPERATED IN BELOW FREEZING TEMPERATURES, THE WATER IN THE DOOR LATCH RELEASE CABLE CAN FREEZE AND CAUSE THE LATCH MECHANISM TO MALFUNCTION.
Consequence & remedy
Consequence: THE MALFUNCTION OF THE DOOR LATCH RELEASE CAN RESULT INTHREE DIFFERENT PROBLEMS: 1) THE DOOR WILL NOT BE ABLE TO BE RELATCHED, 2) THEINSIDE DOOR HANDLE CAN BECOME INOPERATIVE, AND 3) THE DOOR COULD APPEAR TO BELATCHED WHEN IT IS NOT, ALLOWING THE DOOR TO OPEN UNEXPECTEDLY IF IT IS JARRED,AND INCREASING THE RISK OF INJURY TO THE ADJACENT SEAT OCCUPANT.
Remedy: REVISED DOOR RELEASE CABLES AND WATER SHIELDS WILL BE INSTALLED.
Model-level recall history does not show whether a particular VIN is affected or has received a repair. Check a VIN with NHTSA ↗
NHTSA investigations
8EA99032 · Dual Fuel Tank Crossflow/leakage
Opened Nov 4, 1999 · Closed Dec 6, 2001
Status: closed (inferred from source dates) · Vehicle Speed Control:linkages
ON JULY 14, 1993 FORD FILED A DEFECT INFORMATION REPORT CONCERNING FUEL TANK CROSS FLOW LEAKAGE ON F-SERIES LIGHT TRUCKS AND CAB CHASSIS BUILT FROM JULY 22, 1989 THROUGH DECEMBER 17, 1992.THE REMEDY WAS TO REPLACE THE FUEL PRESSURE REGULATOR AND INSTALL A CHECK VALVE BETWEEN EACH FUEL SUPPLY LINE AND FUEL TANK (2) TO REPAIR THE SUPPLY SIDE FUEL CROSS FLOW PROBLEM (RECALL 93V-125).ODI OPENED RQ98-008 ON MAY 29, 1998 BECAUSE OF THE LARGE NUMBER OF ALLEGED REMEDY FAILURES AND REPORTS OF FUEL CROSS FLOW ON VEHICLES OUTSIDE OF THE RECALL POPULATION.BASED ONTHE INFORMATION RECEIVED FROM FORD ON AUGUST 11, SEPTEMBER 30, AND DECEMBER 15, 1998, AND THE INCREASING TREND OF REMEDY FAILURES AND OUT OF SCOPE CROSSFLOW REPORTS, ODI OPENED EA99-032 ON NOVEMBER 4, 1999.THE ATTACHED ENGINEERING ANALYSIS CLOSING REPORT FULLY DESCRIBES THE RESULTS OF THIS INVESTIGATION AND REASON FOR CLOSING.THE SUBJECT VEHICLES CAN EXPERIENCE FUEL TRANSFER FROM ONE TANK TO THE OTHER DUE TO MALFUNCTIONS IN THE FUEL SYSTEM.WHEN FUEL IS PUMPED OR RETURNED TO THE NON-OPERATING TANK (CROSS FLOW), THE CAPACITY OF THE NON-OPERATING TANK CAN BE EXCEEDED, CAUSING FUEL TO OVERFLOW PAST THE FILLER CAP, CREATING A FIRE POTENTIAL.
Additional source detail variants (2)
Vehicle Speed Control:linkages
ON JULY 14, 1993 FORD FILED A DEFECT INFORMATION REPORT CONCERNING FUEL TANK CROSS FLOW LEAKAGE ON F-SERIES LIGHT TRUCKS AND CAB CHASSIS BUILT FROM JULY 22, 1989 THROUGH DECEMBER 17, 1992.THE REMEDY WAS TO REPLACE THE FUEL PRESSURE REGULATOR AND INSTALL A CHECK VALVE BETWEEN EACH FUEL SUPPLY LINE AND FUEL TANK (2) TO REPAIR THE SUPPLY SIDE FUEL CROSS FLOW PROBLEM (RECALL 93V-125).ODI OPENED RQ98-008 ON MAY 29, 1998 BECAUSE OF THE LARGE NUMBER OF ALLEGED REMEDY FAILURES AND REPORTS OF FUEL CROSS FLOW ON VEHICLES OUTSIDE OF THE RECALL POPULATION.BASED ONTHE INFORMATION RECEIVED FROM FORD ON AUGUST 11, SEPTEMBER 30, AND DECEMBER 15, 1998, AND THE INCREASING TREND OF REMEDY FAILURES AND OUT OF SCOPE CROSSFLOW REPORTS, ODI OPENED EA99-032 ON NOVEMBER 4, 1999.THE ATTACHED ENGINEERING ANALYSIS CLOSING REPORT FULLY DESCRIBES THE RESULTS OF THIS INVESTIGATION AND REASON FOR CLOSING.THE SUBJECT VEHICLES CAN EXPERIENCE FUEL TRANSFER FROM ONE TANK TO THE OTHER DUE TO MALFUNCTIONS IN THE FUEL SYSTEM.WHEN FUEL IS PUMPED OR RETURNED TO THE NON-OPERATING TANK (CROSS FLOW), THE CAPACITY OF THE NON-OPERATING TANK CAN BE EXCEEDED, CAUSING FUEL TO OVERFLOW PAST THE FILLER CAP, CREATING A FIRE POTENTIAL.
Vehicle Speed Control:linkages
ON JULY 14, 1993 FORD FILED A DEFECT INFORMATION REPORT CONCERNING FUEL TANK CROSS FLOW LEAKAGE ON F-SERIES LIGHT TRUCKS AND CAB CHASSIS BUILT FROM JULY 22, 1989 THROUGH DECEMBER 17, 1992.THE REMEDY WAS TO REPLACE THE FUEL PRESSURE REGULATOR AND INSTALL A CHECK VALVE BETWEEN EACH FUEL SUPPLY LINE AND FUEL TANK (2) TO REPAIR THE SUPPLY SIDE FUEL CROSS FLOW PROBLEM (RECALL 93V-125).ODI OPENED RQ98-008 ON MAY 29, 1998 BECAUSE OF THE LARGE NUMBER OF ALLEGED REMEDY FAILURES AND REPORTS OF FUEL CROSS FLOW ON VEHICLES OUTSIDE OF THE RECALL POPULATION.BASED ONTHE INFORMATION RECEIVED FROM FORD ON AUGUST 11, SEPTEMBER 30, AND DECEMBER 15, 1998, AND THE INCREASING TREND OF REMEDY FAILURES AND OUT OF SCOPE CROSSFLOW REPORTS, ODI OPENED EA99-032 ON NOVEMBER 4, 1999.THE ATTACHED ENGINEERING ANALYSIS CLOSING REPORT FULLY DESCRIBES THE RESULTS OF THIS INVESTIGATION AND REASON FOR CLOSING.THE SUBJECT VEHICLES CAN EXPERIENCE FUEL TRANSFER FROM ONE TANK TO THE OTHER DUE TO MALFUNCTIONS IN THE FUEL SYSTEM.WHEN FUEL IS PUMPED OR RETURNED TO THE NON-OPERATING TANK (CROSS FLOW), THE CAPACITY OF THE NON-OPERATING TANK CAN BE EXCEEDED, CAUSING FUEL TO OVERFLOW PAST THE FILLER CAP, CREATING A FIRE POTENTIAL.
RQ98008 · Ford F-SERIES Dual Fuel Tank Leakage
Opened May 29, 1998 · Closed Nov 4, 1999
Status: closed (inferred from source dates) · Fuel System, Gasoline:storage:tank Assembly
THESE VEHICLES CAN EXPERIENCE FUEL TRANSFER FROM ONE TANK TO THE OTHER DUE TO A MALFUNCTIONING FUEL PUMP.FROM THE INFORMATION GATHERED TO DATE, IT APPEARS THAT THERE CAN BE MULTIPLE CAUSES AND/OR A COMBINATION OF CAUSES FOR FUEL CROSS FLOW AND THAT THE RECALL REMEDY MAY BE INADEQUATE.FURTHER INVESTIGATION IS NEEDED.THIS INVESTIGATION IS UPGRADED TO EA99-032.CLICK ON DOCUMENT SEARCH BUTTON FOR ADDITIONAL INFORMATION.
EA93022 · Idle Air Spd Ctrl Vlv Malf
Opened Jul 30, 1993 · Closed Aug 31, 1994
Status: closed (inferred from source dates) · Engine And Engine Cooling
There is no summary currently available
EA93020 · Parking Brake Failure
Opened Jul 28, 1993 · Closed Sep 23, 1994
Status: closed (inferred from source dates) · Service Brakes, Hydraulic
There is no summary currently available
Additional source detail variants (2)
Service Brakes, Hydraulic
There is no summary currently available
Service Brakes, Hydraulic
There is no summary currently available
PE93015 · Parking Brake Failure
Opened Mar 9, 1993 · Closed Jul 27, 1993
Status: closed (inferred from source dates) · Service Brakes, Hydraulic
There is no summary currently available
PE93010 · Idle Air Spd Ctrl Vlv Malf
Opened Mar 2, 1993 · Closed Jul 30, 1993
Status: closed (inferred from source dates) · Engine And Engine Cooling
There is no summary currently available
EA93001 · Fuel Expulsion
Opened Jan 7, 1993 · Closed Aug 20, 1993
Status: closed (inferred from source dates) · Vehicle Speed Control:linkages
There is no summary currently available
PE92077 · Fuel Expulsion
Opened Sep 9, 1992 · Closed Jan 7, 1993
Status: closed (inferred from source dates) · Vehicle Speed Control:linkages
There is no summary currently available
Illustration