VEHICLE WILL STALL WITHOUT PRIOR WARNING. ALSO, THERE IS A LOT OF JERKING AND JUMPING IN FRONT. DEALERSHIP IS AWARE OF PROBLEM.*AK
1992 Ford F-150
Owner reports · Recalls · Investigations
Similar to other model years
Owner complaints for the 1992 Ford F-150 do not stand out strongly from the model-year median of 676.
About this comparison →How this year compares
Owner complaints by model year
Compare all F-150 years →Counts vary with age, sales and reporting. They are not failure rates.
What owners reported most
All reported categories
Tap a category to read its complaints. One report may name several components.
When problems were reported
Mileage at the reported incident
Limited mileage data: 49 of 470 reports include usable mileage. There isn’t enough coverage to show a useful chart.
NHTSA’s mileage field refers to the reported incident, not necessarily the filing date. This shows report counts, not the likelihood of a failure.
What to inspect
Issues worth paying extra attention to based on owner reports.
- Fuel System, Gasoline. Review the 231 owner reports in this category and discuss these concerns during a pre-purchase inspection. Read reports →
- Electrical System. Review the 48 owner reports in this category and discuss these concerns during a pre-purchase inspection. Read reports →
- Engine And Engine Cooling. Review the 37 owner reports in this category and discuss these concerns during a pre-purchase inspection. Read reports →
NHTSA owner reports · September 18, 2026 snapshot.
What owners actually said
470 reportsIN OCTOBER OF 1999 A PRIVATE REPAIR SHOP REPLACED FRONT FUEL TANK PUMP CORRECTING A FUEL TANK CROSSOVER PROBLEM. HOWEVER, PROBLEM HAS REOCCURRED, AND FUEL PUMP SENDER ASSEMBLY WAS FAULTY. DEALER COULD NOT REMEDY THE PROBLEM. *AK THE GAS FROM REAR TANK EMPTIES INTO THE FRONT TANK CAUSING GAS TO SPILL. THE CONSUMER HAD IT F…
Read full complaint
IN OCTOBER OF 1999 A PRIVATE REPAIR SHOP REPLACED FRONT FUEL TANK PUMP CORRECTING A FUEL TANK CROSSOVER PROBLEM. HOWEVER, PROBLEM HAS REOCCURRED, AND FUEL PUMP SENDER ASSEMBLY WAS FAULTY. DEALER COULD NOT REMEDY THE PROBLEM. *AK THE GAS FROM REAR TANK EMPTIES INTO THE FRONT TANK CAUSING GAS TO SPILL. THE CONSUMER HAD IT FIXED, BUT THE PROBLEM REOCCURD AND THE CONSUMER RECEIVED RECALL NOTICE AND THE DEALER REPLACED THE FUEL REGULATOR INSTEAD OF THE PUMP AND PROBLEM STILL NOT SOLVED. *YH
CONSUMER RECEIVED RECALL (93S68) AND MADE AN APPOINTMENT FOR THE NECESSARY REPAIRS, HOWEVER WHEN CONSUMER WENT TO DROP OFF THE VEHICLE, HE WAS THEN INFORMED THAT THE PARTS WERE NOT AVAILABLE , AND IF THERE WERE WAS NO GAS LEAKING FROM VEHICLE NOT TO WORRY ABOUT IT, CONSUMER WENT TO ANOTHER DEALER AND WAS ALSO TOLD THERE WERE NO …
Read full complaint
CONSUMER RECEIVED RECALL (93S68) AND MADE AN APPOINTMENT FOR THE NECESSARY REPAIRS, HOWEVER WHEN CONSUMER WENT TO DROP OFF THE VEHICLE, HE WAS THEN INFORMED THAT THE PARTS WERE NOT AVAILABLE , AND IF THERE WERE WAS NO GAS LEAKING FROM VEHICLE NOT TO WORRY ABOUT IT, CONSUMER WENT TO ANOTHER DEALER AND WAS ALSO TOLD THERE WERE NO PARTS AVAILABLE AND NOT TO WORRY.*JB
THIS IS THE FIRST AND ONLY RECALL WE HAVE BEEN NOTIFIED ON THIS VEHICLE. WE NEED TO KNOW IF THERE ARE ANY OTHER RECALLS OF WHICH WE HAVE NOT BEEN NOTIFIED.*AK
93S68 RECALL PERFORMED IN 1993, FUEL TANK MALFUNCTION SAME AS DESCRIBED IN RECALL...OUT OF POCKET EXPENSE $789.83 UNABLE TO OBTAIN REFUND FROM DEALER. *AK
THE GENERAL AMERI-WAY XT 235/75R15XL REAR TIRES FAILED DUE TO TREAD SEPARATION RESULTING IN DAMAGE TO THE VEHICLE AND THE TRAILER, THE CONSUMER STATED THAT THE TIRES WERE DEFECTIVE. *YH
WE ARRIVE IN THE CAR FROM A CHURT ACTIVITY AT 1130 PM .PARKED TRUCK AND GET TO THE HOUSE IN ORDER TO SLEEP. THE SMELL TO BURN RUBBER ALERT US AT 1200PM .THE CAR IGNITION BEEN OFF AND IN THE GARRAGE. *AK
RECALL 93 V 125 000/FUEL TANK ASSEMBLY: UNUSED FUEL FROM ONE TANK TO BE RETURNED TO THE SECOND TANK, WHEN THIS OCCURS SECOND TANK EXCEEDED, CAUSING FUEL SPILLAGES. SPILL CAN RESULT IN A FIRE WHEN EXPOSED TO A SOURCE OF IGNITION. DEALER WAS NOTIFIED, AND INFOMED CONSUMER THAT VEHICLE WAS NOT COVERED UNDER RECALL DUE TO VIN. F…
Read full complaint
RECALL 93 V 125 000/FUEL TANK ASSEMBLY: UNUSED FUEL FROM ONE TANK TO BE RETURNED TO THE SECOND TANK, WHEN THIS OCCURS SECOND TANK EXCEEDED, CAUSING FUEL SPILLAGES. SPILL CAN RESULT IN A FIRE WHEN EXPOSED TO A SOURCE OF IGNITION. DEALER WAS NOTIFIED, AND INFOMED CONSUMER THAT VEHICLE WAS NOT COVERED UNDER RECALL DUE TO VIN. FEEL FREE TO PROVIDE ANY FURTHER DETAILS ON THIS MATTER. *AK
THIS IS THE SECOND FORD F-150 THAT WE HAVE IN WHICH THE ALTERNATOR HAS CAUGHT ON FIRE IN THE LAST TWO WEEKS. THE OTHER ONE WAS A 1991 FORD F-150. VIN [XXX]. THE 1992 F-150 CAUGHT FIRE IN A PARKING LOT AND BURNED UP THE WIRING HARNESS ALONG WITH HOSES, ALTERNATOR, ETC. THE TRUCK IS PROBABLY A TOTAL LOSS. THE OTHER ONE CAUGHT …
Read full complaint
THIS IS THE SECOND FORD F-150 THAT WE HAVE IN WHICH THE ALTERNATOR HAS CAUGHT ON FIRE IN THE LAST TWO WEEKS. THE OTHER ONE WAS A 1991 FORD F-150. VIN [XXX]. THE 1992 F-150 CAUGHT FIRE IN A PARKING LOT AND BURNED UP THE WIRING HARNESS ALONG WITH HOSES, ALTERNATOR, ETC. THE TRUCK IS PROBABLY A TOTAL LOSS. THE OTHER ONE CAUGHT FIRE WHILE TRAVELING DOWN THE HIGHWAY. WE WERE ABLE TO PUT THIS ONE OUT BEFORE MAJOR DAMAGED OCCURRED. I AM VERY DISTRESSED TO HAVE HAD TWO TRUCKS CATCH FIRE IN TWO WEEKS AND FORD MOTOR COMPANY WILL ONLY TRANSFER ME FROM DEPARTMENT TO DEPARTMENT. ANY HELP WOULD BE APPRECIATED. *AK INFORMATION REDACTED PURSUANT TO THE FREEDOM OF INFORMATION ACT (FOIA), 5 U.S.C. 552(B)(6). *TR
EA99-032; FUEL IS BEING PUMPED FROM FRONT TANK TO REAR TANK, CAUSING FUEL SPILLAGE. CAUSE IS UNKNOWN. *AK
Official recalls
394V169001 · Parking Brake:conventional
Sep 7, 1994
THE PARKING BRAKE CONTROL SELF-ADJUST PAWL DOES NOT LINE UP PROPERLY WITH THE SELF-ADJUST RACHET CAUSING THE PAWL TO SLIP OVER ONE OR MORE TEETH IN THE RACHET.
Consequence & remedy
Consequence: WHEN THE ABOVE OCCURS, IT CAN RESULT IN PARKING BRAKE SYSTEM INEFFECTIVENESS. THE PARKING BRAKE WILL NOT HOLD THE VEHICLE, CAUSING THE VEHICLE TO ROLL FREELY, IF THE TRANSMISSION IS NOT LEFT IN GEAR.
Remedy: A WEDGE WILL BE INSTALLED WHICH WILL SERVE TO LOCK THE PARKING BRAKE SELF-ADJUST MECHANISM PAWL INTO ENGAGEMENT WITH THE RACHET. ALSO, OWNERS WILL BE ADVISED TO RELEASE AND REAPPLY THE PARKING BRAKE WHENEVER TOOTH SKIP OCCURS AND WILL BE REMINDED TO ALWAYS TURN OFF THE ENGINE AND LEAVE THE VEHICLE IN GEAR WHEN THE VEHICLE IS PARKED.
93V125000 · Fuel System, Gasoline:storage:tank Assembly
Aug 2, 1993
A MALFUNCTIONING CHECK VALVE WITHIN THE FUEL PUMP ASSEMBLY CAUSES A PORTION OF THE UNUSED FUEL FROM ONE TANK TO BE RETURNED TO THE SECOND TANK. WHEN THIS OCCURS, THE CAPACITY OF THE SECOND TANK CAN BE EXCEEDED, CAUSING FUEL SPILLAGE.
Consequence & remedy
Consequence: SPILLED FUEL CAN RESULT IN A FIRE WHEN EXPOSED TO ASOURCE OF IGNITION.
Remedy: REPLACEMENT OF THE FUEL PRESSURE REGULATOR AND INSTALLATION OF REDUNDANT CHECK VALVES.
92V006000 · Structure:body:door
Jan 14, 1992
WATER CAN ENTER THE DOOR LATCH RELEASE CABLE. IF THE VEHICLE IS OPERATED IN BELOW FREEZING TEMPERATURES, THE WATER IN THE DOOR LATCH RELEASE CABLE CAN FREEZE AND CAUSE THE LATCH MECHANISM TO MALFUNCTION.
Consequence & remedy
Consequence: THE MALFUNCTION OF THE DOOR LATCH RELEASE CAN RESULT INTHREE DIFFERENT PROBLEMS: 1) THE DOOR WILL NOT BE ABLE TO BE RELATCHED, 2) THEINSIDE DOOR HANDLE CAN BECOME INOPERATIVE, AND 3) THE DOOR COULD APPEAR TO BELATCHED WHEN IT IS NOT, ALLOWING THE DOOR TO OPEN UNEXPECTEDLY IF IT IS JARRED,AND INCREASING THE RISK OF INJURY TO THE ADJACENT SEAT OCCUPANT.
Remedy: REVISED DOOR RELEASE CABLES AND WATER SHIELDS WILL BE INSTALLED.
Model-level recall history does not show whether a particular VIN is affected or has received a repair. Check a VIN with NHTSA ↗
NHTSA investigations
8EA99032 · Dual Fuel Tank Crossflow/leakage
Opened Nov 4, 1999 · Closed Dec 6, 2001
Status: closed (inferred from source dates) · Vehicle Speed Control:linkages
ON JULY 14, 1993 FORD FILED A DEFECT INFORMATION REPORT CONCERNING FUEL TANK CROSS FLOW LEAKAGE ON F-SERIES LIGHT TRUCKS AND CAB CHASSIS BUILT FROM JULY 22, 1989 THROUGH DECEMBER 17, 1992.THE REMEDY WAS TO REPLACE THE FUEL PRESSURE REGULATOR AND INSTALL A CHECK VALVE BETWEEN EACH FUEL SUPPLY LINE AND FUEL TANK (2) TO REPAIR THE SUPPLY SIDE FUEL CROSS FLOW PROBLEM (RECALL 93V-125).ODI OPENED RQ98-008 ON MAY 29, 1998 BECAUSE OF THE LARGE NUMBER OF ALLEGED REMEDY FAILURES AND REPORTS OF FUEL CROSS FLOW ON VEHICLES OUTSIDE OF THE RECALL POPULATION.BASED ONTHE INFORMATION RECEIVED FROM FORD ON AUGUST 11, SEPTEMBER 30, AND DECEMBER 15, 1998, AND THE INCREASING TREND OF REMEDY FAILURES AND OUT OF SCOPE CROSSFLOW REPORTS, ODI OPENED EA99-032 ON NOVEMBER 4, 1999.THE ATTACHED ENGINEERING ANALYSIS CLOSING REPORT FULLY DESCRIBES THE RESULTS OF THIS INVESTIGATION AND REASON FOR CLOSING.THE SUBJECT VEHICLES CAN EXPERIENCE FUEL TRANSFER FROM ONE TANK TO THE OTHER DUE TO MALFUNCTIONS IN THE FUEL SYSTEM.WHEN FUEL IS PUMPED OR RETURNED TO THE NON-OPERATING TANK (CROSS FLOW), THE CAPACITY OF THE NON-OPERATING TANK CAN BE EXCEEDED, CAUSING FUEL TO OVERFLOW PAST THE FILLER CAP, CREATING A FIRE POTENTIAL.
Additional source detail variants (2)
Vehicle Speed Control:linkages
ON JULY 14, 1993 FORD FILED A DEFECT INFORMATION REPORT CONCERNING FUEL TANK CROSS FLOW LEAKAGE ON F-SERIES LIGHT TRUCKS AND CAB CHASSIS BUILT FROM JULY 22, 1989 THROUGH DECEMBER 17, 1992.THE REMEDY WAS TO REPLACE THE FUEL PRESSURE REGULATOR AND INSTALL A CHECK VALVE BETWEEN EACH FUEL SUPPLY LINE AND FUEL TANK (2) TO REPAIR THE SUPPLY SIDE FUEL CROSS FLOW PROBLEM (RECALL 93V-125).ODI OPENED RQ98-008 ON MAY 29, 1998 BECAUSE OF THE LARGE NUMBER OF ALLEGED REMEDY FAILURES AND REPORTS OF FUEL CROSS FLOW ON VEHICLES OUTSIDE OF THE RECALL POPULATION.BASED ONTHE INFORMATION RECEIVED FROM FORD ON AUGUST 11, SEPTEMBER 30, AND DECEMBER 15, 1998, AND THE INCREASING TREND OF REMEDY FAILURES AND OUT OF SCOPE CROSSFLOW REPORTS, ODI OPENED EA99-032 ON NOVEMBER 4, 1999.THE ATTACHED ENGINEERING ANALYSIS CLOSING REPORT FULLY DESCRIBES THE RESULTS OF THIS INVESTIGATION AND REASON FOR CLOSING.THE SUBJECT VEHICLES CAN EXPERIENCE FUEL TRANSFER FROM ONE TANK TO THE OTHER DUE TO MALFUNCTIONS IN THE FUEL SYSTEM.WHEN FUEL IS PUMPED OR RETURNED TO THE NON-OPERATING TANK (CROSS FLOW), THE CAPACITY OF THE NON-OPERATING TANK CAN BE EXCEEDED, CAUSING FUEL TO OVERFLOW PAST THE FILLER CAP, CREATING A FIRE POTENTIAL.
Vehicle Speed Control:linkages
ON JULY 14, 1993 FORD FILED A DEFECT INFORMATION REPORT CONCERNING FUEL TANK CROSS FLOW LEAKAGE ON F-SERIES LIGHT TRUCKS AND CAB CHASSIS BUILT FROM JULY 22, 1989 THROUGH DECEMBER 17, 1992.THE REMEDY WAS TO REPLACE THE FUEL PRESSURE REGULATOR AND INSTALL A CHECK VALVE BETWEEN EACH FUEL SUPPLY LINE AND FUEL TANK (2) TO REPAIR THE SUPPLY SIDE FUEL CROSS FLOW PROBLEM (RECALL 93V-125).ODI OPENED RQ98-008 ON MAY 29, 1998 BECAUSE OF THE LARGE NUMBER OF ALLEGED REMEDY FAILURES AND REPORTS OF FUEL CROSS FLOW ON VEHICLES OUTSIDE OF THE RECALL POPULATION.BASED ONTHE INFORMATION RECEIVED FROM FORD ON AUGUST 11, SEPTEMBER 30, AND DECEMBER 15, 1998, AND THE INCREASING TREND OF REMEDY FAILURES AND OUT OF SCOPE CROSSFLOW REPORTS, ODI OPENED EA99-032 ON NOVEMBER 4, 1999.THE ATTACHED ENGINEERING ANALYSIS CLOSING REPORT FULLY DESCRIBES THE RESULTS OF THIS INVESTIGATION AND REASON FOR CLOSING.THE SUBJECT VEHICLES CAN EXPERIENCE FUEL TRANSFER FROM ONE TANK TO THE OTHER DUE TO MALFUNCTIONS IN THE FUEL SYSTEM.WHEN FUEL IS PUMPED OR RETURNED TO THE NON-OPERATING TANK (CROSS FLOW), THE CAPACITY OF THE NON-OPERATING TANK CAN BE EXCEEDED, CAUSING FUEL TO OVERFLOW PAST THE FILLER CAP, CREATING A FIRE POTENTIAL.
RQ98008 · Ford F-SERIES Dual Fuel Tank Leakage
Opened May 29, 1998 · Closed Nov 4, 1999
Status: closed (inferred from source dates) · Fuel System, Gasoline:storage:tank Assembly
THESE VEHICLES CAN EXPERIENCE FUEL TRANSFER FROM ONE TANK TO THE OTHER DUE TO A MALFUNCTIONING FUEL PUMP.FROM THE INFORMATION GATHERED TO DATE, IT APPEARS THAT THERE CAN BE MULTIPLE CAUSES AND/OR A COMBINATION OF CAUSES FOR FUEL CROSS FLOW AND THAT THE RECALL REMEDY MAY BE INADEQUATE.FURTHER INVESTIGATION IS NEEDED.THIS INVESTIGATION IS UPGRADED TO EA99-032.CLICK ON DOCUMENT SEARCH BUTTON FOR ADDITIONAL INFORMATION.
EA93022 · Idle Air Spd Ctrl Vlv Malf
Opened Jul 30, 1993 · Closed Aug 31, 1994
Status: closed (inferred from source dates) · Engine And Engine Cooling
There is no summary currently available
EA93020 · Parking Brake Failure
Opened Jul 28, 1993 · Closed Sep 23, 1994
Status: closed (inferred from source dates) · Service Brakes, Hydraulic
There is no summary currently available
Additional source detail variants (2)
Service Brakes, Hydraulic
There is no summary currently available
Service Brakes, Hydraulic
There is no summary currently available
PE93015 · Parking Brake Failure
Opened Mar 9, 1993 · Closed Jul 27, 1993
Status: closed (inferred from source dates) · Service Brakes, Hydraulic
There is no summary currently available
PE93010 · Idle Air Spd Ctrl Vlv Malf
Opened Mar 2, 1993 · Closed Jul 30, 1993
Status: closed (inferred from source dates) · Engine And Engine Cooling
There is no summary currently available
EA93001 · Fuel Expulsion
Opened Jan 7, 1993 · Closed Aug 20, 1993
Status: closed (inferred from source dates) · Vehicle Speed Control:linkages
There is no summary currently available
PE92077 · Fuel Expulsion
Opened Sep 9, 1992 · Closed Jan 7, 1993
Status: closed (inferred from source dates) · Vehicle Speed Control:linkages
There is no summary currently available
Illustration