I RECENTLY BOUGHT A USED 1996 FLEETWOOD BOUNDER CLASS A MOTORHOME. BOTH THE LEFT AND RIGHT FRONT SIDE WINDOWS ARE FOGGED UP WITH THIS APPARENTLY HAPPENING BETWEEN THE SANDWICHED PANES OF GLASS. IT IS DIFFICULT TO SEE OUT OF THESE WINDOWS, OR VIEW THE REAR VIEW MIRRORS. FROM TALKING TO OTHERS, I UNDERSTAND THIS IS NOT THE EXCE…
Read full complaint
I RECENTLY BOUGHT A USED 1996 FLEETWOOD BOUNDER CLASS A MOTORHOME. BOTH THE LEFT AND RIGHT FRONT SIDE WINDOWS ARE FOGGED UP WITH THIS APPARENTLY HAPPENING BETWEEN THE SANDWICHED PANES OF GLASS. IT IS DIFFICULT TO SEE OUT OF THESE WINDOWS, OR VIEW THE REAR VIEW MIRRORS. FROM TALKING TO OTHERS, I UNDERSTAND THIS IS NOT THE EXCEPTION, BUT RATHER THE RULE. *TR
NHTSA ODI #10264337
45,000 miles · Aug 14, 2005
Visibility
STATIONARY INSULATED WINDOWS ON PASSENGER AND DRIVERS SIDE CLOUDED MAKING IT DIFFICULT TO SEE REAR VIEW MIRRORS AND TO SEE APPROACHING TRAFFIC FROM LEFT AND RIGHT AT INTERSECTIONS. *NM
NHTSA ODI #10132806
Mileage unknown · Jun 20, 2005
Visibility
DT: CONSUMER STATES: PASSENGER'S WINDOW WAS REPLACED, WINDOW WAS ALMOST OPENED. HAD TO OPEN THE WINDOW, AND PUT HEAD OUT IN ORDER TO SEE TO BACK UP OR TO CHANGE LANES.*AK
NHTSA ODI #10122043
Mileage unknown · Sep 16, 2000
Visibility
DOUBLE GLAZED WINDOW IS DISCOLORED,BLOCKING VISION OF SIDE MIRROR. MFG. DENIES THAT WINDOWS ARE INCLUDED IN RECALL AND WILL NOT REPAIR. WINDOWS WERE RECALLED IN "98 DUE TO IMPROPER GLAZING. DEFINATE SAFETY HAZARD DUE TO LOSS OF VISION TO SIDE OF VEHICLE
NHTSA ODI #731638
Mileage unknown · Oct 1, 1998
Visibility
CONSUMER LEARNED OF A POSSIBLE RECALL ON THE INTERNET, CALLED MANUFACTURER AND WAS TOLD THAT THERE WAS NO RECALL. / NHTSA RECALL 98V-147 . *AK *JB
VEHICLE DESCRIPTION: MOTOR HOMES. THE DRIVER'S AND PASSENGER'S SIDE WINDOWS DO NOT MEET THE REQUIREMENTS OF FMVSS NO. 205, "GLAZING MATERIALS," FOR AN ACCEPTABLE LEVEL OF TINT.
Consequence & remedy
Consequence: THIS CONDITION COULD CAUSE THE DRIVER REDUCED VISIBILITY THROUGH THE SIDE WINDOWS WHEN BACKING UP, WHEN USING THE MIRRORS FOR LANE CHANGES, OR WHENEVER LOOKING THROUGH THE WINDOWS, INCREASING THE RISK OF A VEHICLE CRASH.
THE ELECTRIC WIRE USED TO POWER THE EXPANDABLE ROOM HYDRAULIC PUMP MOTOR WAS NOT EQUIPPED WITH A CIRCUIT BREAKER. OVERHEATING OF THE WIRE CAN OCCUR WITH INCORRECT EXPANDABLE ROOM OPERATION.
Consequence & remedy
Consequence: THIS CONDITION CAN CAUSE THE WIRE INSULATION TO MELT, CAUSING SMOKE AND POSSIBLE FIRE.
Remedy: DEALERS WILL INSTALL A CIRCUIT BREAKER TO THE EXPANDABLE ROOM SYSTEM PUMP MOTOR WIRE. FLEETWOOD WILL ALSO PROVIDE A VEHICLE LABEL TO IDENTIFY THE LOCATION OF THE CIRCUIT BREAKER, AND WILL PROVIDE OWNER'S MANUAL LITERATURE TO IDENTIFY THE CIRCUIT BREAKER LOCATION.
Model-level recall history does not show whether a particular VIN is affected or has received a repair. Check a VIN with NHTSA ↗
NHTSA investigations
0
No exact-year investigations in this snapshot.
1996 Fleetwood Bounder Problems, Complaints & Recalls | Skip That Year