← New search

2012 Chevrolet Silverado 3500

Owner reports · Recalls · Investigations

Similar to other model years

Owner complaints for the 2012 Chevrolet Silverado 3500 do not stand out strongly from the model-year median of 35.

About this comparison →

How this year compares

Owner complaints by model year

Other model years Selected year
Compare all Silverado 3500 years →

Counts vary with age, sales and reporting. They are not failure rates.

What owners reported most

All reported categories

Tap a category to read its complaints. One report may name several components.

When problems were reported

Mileage at the reported incident

Limited mileage data: 14 of 23 reports include usable mileage. There isn’t enough coverage to show a useful chart.

NHTSA’s mileage field refers to the reported incident, not necessarily the filing date. This shows report counts, not the likelihood of a failure.

What to inspect

Issues worth paying extra attention to based on owner reports.

  • Tires. Review the 6 owner reports in this category and discuss these concerns during a pre-purchase inspection. Read reports →
  • Air Bags. Review the 4 owner reports in this category and discuss these concerns during a pre-purchase inspection. Read reports →
  • Engine. Review the 4 owner reports in this category and discuss these concerns during a pre-purchase inspection. Read reports →

NHTSA owner reports · September 18, 2026 snapshot.

1 crash reports0 fire reports0 injury reports

What owners actually said

23 reports
Mileage unknown · Dec 12, 2025
Tires

Tire - 265/70 r18 Cooper Could have been a very bad accident. Tire blew out. The tire was inspected by Goodyear PCA-Visual only -recvd below response after several requests. All Internal Goodyear visual Inspection procedures & methodologies are confidential and/or proprietary information of The Goodyear…

Read full complaint

Tire - 265/70 r18 Cooper Could have been a very bad accident. Tire blew out. The tire was inspected by Goodyear PCA-Visual only -recvd below response after several requests. All Internal Goodyear visual Inspection procedures & methodologies are confidential and/or proprietary information of The Goodyear Tire and Rubber Company. Goodyear's findings in this claim are final, and we have closed our file with no further action.

NHTSA ODI #11704782

Mileage unknown · Oct 7, 2025
Tires

TIRE - 265/70 R18 Failure: Tire caused vehicle damage - Tire is at Goodyear Tire - Akron, Ohio Pulled off the road to change tire - was helped by someone that saw incident and lived close by. Yes - Filed a claim with insurance -see attached-and Property Damage Claim Team - Goodyear Tire- PDCT re George_theodore@goodyear.com - Cl…

Read full complaint

TIRE - 265/70 R18 Failure: Tire caused vehicle damage - Tire is at Goodyear Tire - Akron, Ohio Pulled off the road to change tire - was helped by someone that saw incident and lived close by. Yes - Filed a claim with insurance -see attached-and Property Damage Claim Team - Goodyear Tire- PDCT re George_theodore@goodyear.com - Claim # 000645055. Claim was denied. Provided proof that tires were maintained properly by periodic rotation and inspection and requested Goodyear findings twice and still have not received. Claim denied again. Last request to Goodyear was 10/2 requesting their documentation. Waiting for tire to be returned and response to our request. Warning -the vehicle started vibrating

NHTSA ODI #11691934

197,000 miles · Sep 4, 2024
Fuel System, Diesel

The contact owns a 2012 Chevrolet Silverado 3500. The contact stated that the vehicle would be low or completely out of fuel quicker than expected. The contact stated that while attempting to refuel, the contact was unable to fill the rear tank due to the tank being full of fuel. The vehicle had been taken to an independent mech…

Read full complaint

The contact owns a 2012 Chevrolet Silverado 3500. The contact stated that the vehicle would be low or completely out of fuel quicker than expected. The contact stated that while attempting to refuel, the contact was unable to fill the rear tank due to the tank being full of fuel. The vehicle had been taken to an independent mechanic where it was diagnosed and determined that the transfer pump had failed to transfer fuel from the rear tank to the front tank. The contact was informed that the transfer pump needed to be replaced. The vehicle had not been repaired. The manufacturer was not made aware of the failure. The failure mileage was 197,000.

NHTSA ODI #11612575

68,000 miles · Aug 29, 2024
EngineFuel System, Diesel

The contact owns a 2012 Chevrolet Silverado 3500. While the contact's sister was driving 65 MPH, the vehicle began to jerk with the check engine warning light illuminated violently. The contact stated that the vehicle stalled in the middle of the highway. The contact called California Highway Patrol who assisted with getting the…

Read full complaint

The contact owns a 2012 Chevrolet Silverado 3500. While the contact's sister was driving 65 MPH, the vehicle began to jerk with the check engine warning light illuminated violently. The contact stated that the vehicle stalled in the middle of the highway. The contact called California Highway Patrol who assisted with getting the vehicle off the road. The vehicle was eventually towed to the dealer where the vehicle was diagnosed with a defective fuel pump. The manufacturer was notified of the failure but offered no assistance. The vehicle remained in the possession of the dealer and was not repaired. The failure mileage was approximately 68,000.

NHTSA ODI #11611607

Mileage unknown · Jun 26, 2023
Tires

Cooper Discoverer HT3 265/70R18 Tread and sidewall separation. became very dangerous to drive. ALL 4 tires became defective.

NHTSA ODI #11528860

Mileage unknown · May 13, 2023
Structure

Our dashboard is beyond cracked, repair cost $2100.00 plus. I was told that the dash needed to have a metal brace installed with repair. We used a sun reflector from day one. We have a little more than 25k miles on it and the vehicle is immaculate except for the 3rd brake light leaking which we have tried to repair over and ove…

Read full complaint

Our dashboard is beyond cracked, repair cost $2100.00 plus. I was told that the dash needed to have a metal brace installed with repair. We used a sun reflector from day one. We have a little more than 25k miles on it and the vehicle is immaculate except for the 3rd brake light leaking which we have tried to repair over and over again another flaw design. We finally got our airbag replaced and now the dash is worse than ever. How are we expected to ever get anything even close to resale value for this vehicle. We paid 36,000.00 We did nothing wrong except be a loyal chevrolet customer for our entire lives. We loved chevy but unfortunately since chevrolet refuses to admit that there is a flaw in these dashboards we would not in clear conscience buy from the company again, it's too bad we wanted to trade it in for a 2023. David Shoemaker The starburst breakage is from airbag replacement the straight lines is chevy defect. I think you should meet us halfway on this at least.

NHTSA ODI #11521797

Mileage unknown · Jul 10, 2022
EngineFuel/propulsion System

Our diesel fuel pump failed unexpectedly and without any notice while pulling a fifth wheel camper on a state highway in Ohio. The engine stopped completely (we were coasting within seconds). We were in a one-lane construction zone, and had it not been for a paved median, I would have been unable to pull off in this constructi…

Read full complaint

Our diesel fuel pump failed unexpectedly and without any notice while pulling a fifth wheel camper on a state highway in Ohio. The engine stopped completely (we were coasting within seconds). We were in a one-lane construction zone, and had it not been for a paved median, I would have been unable to pull off in this construction zone. Fortunately, I had enough momentum to get off the road and was able to exert enough pressure on the brakes manually to stop. In reading about this issue, it is clear that there are known problems with this fuel pump. My cost to repair this defective part will be about $11,500 and will require a 12 hour round trip back to Ohio to pick-up the vehicle after a two-week repair.

NHTSA ODI #11473264

Mileage unknown · Oct 28, 2021
Air Bags

It is amazing to me that a recall is issued in March 2021 and nothing has been done yet and they still are building vehicles probably with defective equipment if there isn't a fix for this recall. GM recall # N212328800

NHTSA ODI #11438473

Mileage unknown · Sep 20, 2021
Air Bags

Takata recall. The contact owns a 2012 Chevrolet Silverado 3500. The contact received a recall notice for NHTSA Campaign Number 21V051000 (Air Bags) however, upon contacting the dealer, he was informed that the repair might cause the dashboard to crack. The contact was then informed that he needed to sign a waiver to ensure that…

Read full complaint

Takata recall. The contact owns a 2012 Chevrolet Silverado 3500. The contact received a recall notice for NHTSA Campaign Number 21V051000 (Air Bags) however, upon contacting the dealer, he was informed that the repair might cause the dashboard to crack. The contact was then informed that he needed to sign a waiver to ensure that the dealer would not be held responsible for any damages to vehicle. The contact declined to sign the waiver and the vehicle was not repaired. The manufacturer was not made aware of the issue. The contact had not experienced a failure. Parts distribution disconnect.

NHTSA ODI #11433572

Mileage unknown · Dec 20, 2019
Unknown Or Other

DASH IN CRACKING BOTH SIDES.

NHTSA ODI #11290391

Official recalls

4

21V051000 · Air Bags:frontal:passenger Side:inflator Module

Feb 5, 2021

General Motors, LLC (GM) is recalling certain 2012 Cadillac Escalade, Escalade ESV, Escalade EXT, Chevrolet Avalanche, Silverado 1500, Silverado 2500/3500, Suburban, Tahoe, GMC Sierra 1500, Sierra 2500/3500, Yukon, and Yukon XL originally sold, or ever registered, in the states of Alabama, California, Florida, Georgia, Hawaii, Louisiana, Mississippi, South Carolina, Texas, Puerto Rico, American Samoa, Guam, the Northern Mariana Islands (Saipan), and the U.S. Virgin Islands or "Zone A." These vehicles are equipped with non-desiccated passenger frontal inflators containing phase-stabilized ammonium nitrate (PSAN) propellant. These inflators may explode due to propellant degradation occurring after long-term exposure to high absolute humidity, high temperatures, and high temperature cycling.

Consequence & remedy

Consequence: An inflator explosion may result in sharp metal fragments striking the driver or other occupants, resulting in serious injury or death.

Remedy: GM will notify owners, and dealers will replace the front passenger air bag inflator with an alternate one, free of charge. Interim letters notifying owners of the safety risk were mailed on February 22, 2021. Second notification letters will be mailed once the remedy is available. Owner notification letters were mailed on May 11, 2021. Owners may contact Cadillac customer service at 1-800-458-8006; Chevrolet customer service at 1-800-222-1020; and GMC customer service at 1-800-462-8782. GM's number for this recall is N212328770.

21V054000 · Air Bags:frontal:passenger Side:inflator Module

Feb 5, 2021

General Motors, LLC (GM) is recalling certain 2014 Cadillac Escalade, Escalade ESV, Chevrolet Silverado 2500, Silverado 3500, Suburban, Tahoe, GMC Sierra 2500, Sierra 3500, Yukon, and Yukon XL vehicles originally sold, or ever registered, in the states of AL, CA, FL, GA, HI, LA, MS, SC, TX, PR, AS, GU, the MP, and VI or "Zone A." Additionally GM is recalling certain 2011-2014 Cadillac Escalade, Escalade ESV, Chevrolet Silverado 2500, Silverado 3500, Suburban, Tahoe, GMC Sierra 2500, Sierra 3500, Yukon, Yukon XL and 2011-2013 Cadillac Escalade EXT, Chevrolet Avalanche, Silverado 1500, and GMC Sierra 1500 vehicles originally sold, or ever registered, in the states of AZ, AR, DE, DC, IL, IN, KS, KY, MD, MO, NE, NV, NJ, NM, NC, OH, OK, PA, TN, VA, and WV or "Zone B." Additionally, GM is recalling certain 2010-2014 Cadillac Escalade, Escalade ESV, Chevrolet Silverado 2500, Silverado 3500, Suburban, Tahoe, GMC Sierra 2500, Sierra 3500, Yukon, and Yukon XL and 2010-2013 Cadillac Escalade EXT, Chevrolet Avalanche, Silverado 1500, and GMC Sierra 1500 vehicles originally sold, or ever registered, in the states of AK, CO, CT, ID, IA, ME, MA, MI, MN, MT, NH, NY, ND, OR, RI, SD, UT, VT, WA, WI, and WY or "Zone C." These vehicles are equipped with non-desiccated passenger frontal inflators containing phase-stabilized ammonium nitrate (PSAN) propellant. These inflators may explode due to propellant degradation occurring after long-term exposure to high absolute humidity, high temperatures, and high temperature cycling.

Consequence & remedy

Consequence: An inflator explosion may result in sharp metal fragments striking the driver or other occupants, resulting in serious injury or death.

Remedy: GM will notify owners, and dealers will replace the front passenger air bag inflator with an alternate one, free of charge. Interim letters notifying owners of the safety risk were mailed on February 25, 2021. Second notification letters will be mailed once the remedy is available. Owner notification letters were mailed to 40 VIN owners on May 11, 2021. A second owner notification letter was mailed to all other owners on January 24, 2022. Owners may contact Chevrolet customer service at 1-800-222-1020; Cadillac customer service at 1-800-458-8006; and GMC customer service at 1-800-462-8782. GM's number for this recall is N212328800.

18V267000 · Equipment

Apr 26, 2018

General Motors LLC (GM) is recalling certain 2009-2014 Chevrolet Silverado HD and GMC Sierra HD, 2009 GMC Topkick 5000, 6000, 7000 and 8000 Series and Isuzu F Series, and 2009-2018 Chevrolet Express, and GMC Savana vehicles, equipped with certain Plastic-Handle Fire Extinguishers or Push Button 'Pindicator' Fire Extinguishers. These extinguishers may become clogged, preventing the extinguisher from discharging as expected or requiring excessive force to activate the extinguisher. Additionally, in certain models, the nozzle may detach from the valve assembly with enough force that it could cause injury and also render the product inoperable. For a full list of the affected fire extinguisher models visit: https://static.nhtsa.gov/odi/rcl/2017/RMISC-17E062-5427.pdf

Consequence & remedy

Consequence: In the event of a fire, if the fire extinguisher does not function properly, it can increase the risk of injury.

Remedy: GM will notify owners, instructing them to contact Kidde to get a replacement fire extinguisher, free of charge. The recall began June 11, 2018. Owners may contact Chevrolet customer service at 1-800-222-1020, GMC customer service at 1-800-462-8782, and Isuzu customer service at 1-866-441-9638. GM's number for this recall is 18146.

17V664000 · Fuel System, Gasoline:storage:auxillary Tank

Oct 19, 2017

General Motors LLC (GM) is recalling certain 2011-2015 Chevrolet Silverado 3500 and GMC Sierra 3500 trucks equipped with dual fuel tanks. The low fuel level sensor for the front tank may stick causing the rear tank to overfill the front tank.

Consequence & remedy

Consequence: If the front tank overfills, the excess pressure may cause the front tank to expand and contact the driveshaft, possibly resulting in a hole in the tank. The hole will leak fuel, which in the presence of an ignition source, can increase the risk of a fire.

Remedy: GM has notified owners, and dealers will replace the rear tank fuel pump or update the fuel-level sensor software, as well as inspect the front tank, replacing it as necessary, free of charge. The recall began December 11, 2017. Owners may contact GM customer service for Chevrolet 1-800-222-1020 or for GMC customer service at 1-800-462-8782. GM's number for this recall is 17399.

Model-level recall history does not show whether a particular VIN is affected or has received a repair. Check a VIN with NHTSA ↗

NHTSA investigations

1

EA21002 · Desiccated Air Bag Inflator Rupture

Opened Sep 17, 2021 · No close date supplied

Status: open (inferred from source dates) · Air Bags:frontal:driver Side:inflator Module; Air Bags:frontal:passenger Side:inflator Module

From 2000 through 2017, Takata produced millions of air bag inflators using two types of phase-stabilized ammonium nitrate ("PSAN") propellant -- propellant 2004 and propellant 2004L. After prolonged exposure to high temperature cycles and humidity, inflators using propellant 2004 can degrade, causing the propellant to burn too quickly when ignited. The rapid burning can cause the inflator to rupture during deployment, potentially causing serious or even fatal injury to vehicle occupants. See 2016 Blomquist Report at www.nhtsa.gov/sites/nhtsa.gov/files/documents/expert_report-hrblomquist.pdf.Consequently, all frontal inflators using propellant 2004 that do not contain a "desiccant" (a substance that traps and holds moisture) in US vehicles are under recall. These "non-desiccated" inflators either have been or are required to be replaced.In some cases, the remedy part for these recalled inflators was, or will be, an inflator using either propellant 2004 or 2004L that does contain a desiccant. None of these "desiccated" remedy parts (which were installed in older model year vehicles) are currently under recall for a degradation concern. Certain subsets of desiccated PSAN inflators using propellant 2004 for use as original equipment, however, have been recalled for a degradation concern. All Takata inflators produced with propellant 2004L contain desiccant, and none of these desiccated inflators using propellant 2004L are under recall for a degradation concern. There have been no reported field ruptures in any non-recalled desiccated PSAN inflators.It is understood that desiccants fully saturate at some threshold, at which point any additional moisture will not be captured. This means the degradation process observed in non-desiccated inflators using propellant 2004 may also occur in non-recalled desiccated inflators using propellant 2004, assuming additional moisture enters the inflator and high temperature cycling occurs. Based on available information, desiccant saturation can occur within the first five years in the worst environments, and the time required for full saturation is affected by multiple factors. While no present safety risk has been identified, further work is needed to evaluate the future risk of non-recalled desiccated inflators using propellant 2004.Three entities -- Takata (now known as TK Global), the Independent Testing Coalition, and Exponent -- have been studying the long-term behavior of Takata desiccated PSAN inflators using propellant 2004L (as well as 2004) in the presence of moisture and temperature cycling. The research efforts, which include development of predictive modeling techniques and field sample analysis, are ongoing. To date, none of the researchers have identified field evidence showing that propellant 2004L is undergoing a degradation process that leads to aggressive deployment and potential rupture. However, the time in service of such inflators remains short compared to that of the inflators using propellant 2004. Further study is needed to assess the long-term safety of desiccated inflators using propellant 2004L.The Office of Defects Investigation is opening this investigation to examine whether a safety defect related to propellant degradation exists in non-recalled desiccated PSAN frontal inflators manufactured by Takata. This investigation will require extensive information on Takata production processes and surveys of inflators in the field. Lists of recall actions that may have used desiccated PSAN inflators as remedy parts, as well as the makes and models originally manufactured with them, is available with the downloadable version of this document (see nhtsa.gov/recalls?nhtsaId=EA21002 -- note this information is subject to change/revision as the investigation proceeds). This investigation does not supersede EA15-001, which remains open.

Additional source detail variants (2)

Air Bags:frontal:driver Side:inflator Module

From 2000 through 2017, Takata produced millions of air bag inflators using two types of phase-stabilized ammonium nitrate ("PSAN") propellant -- propellant 2004 and propellant 2004L. After prolonged exposure to high temperature cycles and humidity, inflators using propellant 2004 can degrade, causing the propellant to burn too quickly when ignited. The rapid burning can cause the inflator to rupture during deployment, potentially causing serious or even fatal injury to vehicle occupants. See 2016 Blomquist Report at www.nhtsa.gov/sites/nhtsa.gov/files/documents/expert_report-hrblomquist.pdf.Consequently, all frontal inflators using propellant 2004 that do not contain a "desiccant" (a substance that traps and holds moisture) in US vehicles are under recall. These "non-desiccated" inflators either have been or are required to be replaced.In some cases, the remedy part for these recalled inflators was, or will be, an inflator using either propellant 2004 or 2004L that does contain a desiccant. None of these "desiccated" remedy parts (which were installed in older model year vehicles) are currently under recall for a degradation concern. Certain subsets of desiccated PSAN inflators using propellant 2004 for use as original equipment, however, have been recalled for a degradation concern. All Takata inflators produced with propellant 2004L contain desiccant, and none of these desiccated inflators using propellant 2004L are under recall for a degradation concern. There have been no reported field ruptures in any non-recalled desiccated PSAN inflators.It is understood that desiccants fully saturate at some threshold, at which point any additional moisture will not be captured. This means the degradation process observed in non-desiccated inflators using propellant 2004 may also occur in non-recalled desiccated inflators using propellant 2004, assuming additional moisture enters the inflator and high temperature cycling occurs. Based on available information, desiccant saturation can occur within the first five years in the worst environments, and the time required for full saturation is affected by multiple factors. While no present safety risk has been identified, further work is needed to evaluate the future risk of non-recalled desiccated inflators using propellant 2004.Three entities -- Takata (now known as TK Global), the Independent Testing Coalition, and Exponent -- have been studying the long-term behavior of Takata desiccated PSAN inflators using propellant 2004L (as well as 2004) in the presence of moisture and temperature cycling. The research efforts, which include development of predictive modeling techniques and field sample analysis, are ongoing. To date, none of the researchers have identified field evidence showing that propellant 2004L is undergoing a degradation process that leads to aggressive deployment and potential rupture. However, the time in service of such inflators remains short compared to that of the inflators using propellant 2004. Further study is needed to assess the long-term safety of desiccated inflators using propellant 2004L.The Office of Defects Investigation is opening this investigation to examine whether a safety defect related to propellant degradation exists in non-recalled desiccated PSAN frontal inflators manufactured by Takata. This investigation will require extensive information on Takata production processes and surveys of inflators in the field. Lists of recall actions that may have used desiccated PSAN inflators as remedy parts, as well as the makes and models originally manufactured with them, is available with the downloadable version of this document (see nhtsa.gov/recalls?nhtsaId=EA21002 -- note this information is subject to change/revision as the investigation proceeds). This investigation does not supersede EA15-001, which remains open.

Air Bags:frontal:passenger Side:inflator Module

From 2000 through 2017, Takata produced millions of air bag inflators using two types of phase-stabilized ammonium nitrate ("PSAN") propellant -- propellant 2004 and propellant 2004L. After prolonged exposure to high temperature cycles and humidity, inflators using propellant 2004 can degrade, causing the propellant to burn too quickly when ignited. The rapid burning can cause the inflator to rupture during deployment, potentially causing serious or even fatal injury to vehicle occupants. See 2016 Blomquist Report at www.nhtsa.gov/sites/nhtsa.gov/files/documents/expert_report-hrblomquist.pdf.Consequently, all frontal inflators using propellant 2004 that do not contain a "desiccant" (a substance that traps and holds moisture) in US vehicles are under recall. These "non-desiccated" inflators either have been or are required to be replaced.In some cases, the remedy part for these recalled inflators was, or will be, an inflator using either propellant 2004 or 2004L that does contain a desiccant. None of these "desiccated" remedy parts (which were installed in older model year vehicles) are currently under recall for a degradation concern. Certain subsets of desiccated PSAN inflators using propellant 2004 for use as original equipment, however, have been recalled for a degradation concern. All Takata inflators produced with propellant 2004L contain desiccant, and none of these desiccated inflators using propellant 2004L are under recall for a degradation concern. There have been no reported field ruptures in any non-recalled desiccated PSAN inflators.It is understood that desiccants fully saturate at some threshold, at which point any additional moisture will not be captured. This means the degradation process observed in non-desiccated inflators using propellant 2004 may also occur in non-recalled desiccated inflators using propellant 2004, assuming additional moisture enters the inflator and high temperature cycling occurs. Based on available information, desiccant saturation can occur within the first five years in the worst environments, and the time required for full saturation is affected by multiple factors. While no present safety risk has been identified, further work is needed to evaluate the future risk of non-recalled desiccated inflators using propellant 2004.Three entities -- Takata (now known as TK Global), the Independent Testing Coalition, and Exponent -- have been studying the long-term behavior of Takata desiccated PSAN inflators using propellant 2004L (as well as 2004) in the presence of moisture and temperature cycling. The research efforts, which include development of predictive modeling techniques and field sample analysis, are ongoing. To date, none of the researchers have identified field evidence showing that propellant 2004L is undergoing a degradation process that leads to aggressive deployment and potential rupture. However, the time in service of such inflators remains short compared to that of the inflators using propellant 2004. Further study is needed to assess the long-term safety of desiccated inflators using propellant 2004L.The Office of Defects Investigation is opening this investigation to examine whether a safety defect related to propellant degradation exists in non-recalled desiccated PSAN frontal inflators manufactured by Takata. This investigation will require extensive information on Takata production processes and surveys of inflators in the field. Lists of recall actions that may have used desiccated PSAN inflators as remedy parts, as well as the makes and models originally manufactured with them, is available with the downloadable version of this document (see nhtsa.gov/recalls?nhtsaId=EA21002 -- note this information is subject to change/revision as the investigation proceeds). This investigation does not supersede EA15-001, which remains open.