← New search

2009 Chevrolet Silverado 1500

Owner reports · Recalls · Investigations

Similar to other model years

Owner complaints for the 2009 Chevrolet Silverado 1500 do not stand out strongly from the model-year median of 525.

About this comparison →

When problems were reported

Mileage at the reported incident

224 reports with mileage · 220 unknown

NHTSA’s mileage field refers to the reported incident, not necessarily the filing date. This shows report counts, not the likelihood of a failure.

What to inspect

Issues worth paying extra attention to based on owner reports.

  • Air Bags. Review the 230 owner reports in this category and discuss these concerns during a pre-purchase inspection. Read reports →
  • Structure. Review the 54 owner reports in this category and discuss these concerns during a pre-purchase inspection. Read reports →
  • Electrical System. Review the 43 owner reports in this category and discuss these concerns during a pre-purchase inspection. Read reports →

NHTSA owner reports · September 18, 2026 snapshot.

9 crash reports6 fire reports3 injury reports

Structure complaints

54 reports
Clear category filter
Mileage unknown · Feb 16, 2013
Air BagsStructure

1.) I HAVE NOTICED THAT I HAVE TWO CRACKS ON MY DASH BOARD 2FT 8"INCHES APART . 2.) MY MAIN CONCERN IS THE CRACK ON THE LEFT SIDE OF THE PASSENGER AIR BAG 1"INCH LONG INTO THE AIR BAG COMPARTMENT GROVE. 3.) I HAVE ONLY 2,189 MILES ON MY TRUCK. *TR

NHTSA ODI #10498376

4,900 miles · Jul 20, 2011
StructureCrash

TL* THE CONTACT OWNS A 2009 CHEVROLET SILVERADO 1500. THE CONTACT STATED THAT WHILE DRIVING IN REVERSE AT 2 MPH, THE REAR BUMPER BENT SEVERELY AFTER CRASHING INTO A RAIL. THE CONTACT STATED THE DEALER NOR MANUFACTURER WERE NOTIFIED OF THE FAILURE. THE CONTACT DID NOT MENTION IF THE POLICE WERE CALLED OR IF THERE WERE ANY INJUR…

Read full complaint

TL* THE CONTACT OWNS A 2009 CHEVROLET SILVERADO 1500. THE CONTACT STATED THAT WHILE DRIVING IN REVERSE AT 2 MPH, THE REAR BUMPER BENT SEVERELY AFTER CRASHING INTO A RAIL. THE CONTACT STATED THE DEALER NOR MANUFACTURER WERE NOTIFIED OF THE FAILURE. THE CONTACT DID NOT MENTION IF THE POLICE WERE CALLED OR IF THERE WERE ANY INJURIES. THE VEHICLE WAS NOT REPAIRED. THE FAILURE MILEAGE WAS 4,900 AND THE CURRENT MILEAGE WAS 5,000. THE VIN WAS UNAVAILABLE.

NHTSA ODI #10413782

3,000 miles · Mar 11, 2010
Latches/locks/linkagesStructureVehicle Speed Control

INFORMATION REDACTED PURSUANT TO THE FREEDOM OF INFORMATION ACT (FOIA), 5 U.S.C. 552(B)(6) I OWN A 2009 CHEVY PICKUP WITH A EXTENDED CAB WHEN I DRIVE DOWN THE ROAD THE DOORS SHUTTER AND FEEL LIKE THEY ARE GOING TO OPEN THE DEALER IS SAYING THERE WAS A NATIONAL RECALL FOR STRIKER PLATES THEY PUT THEM ON WITH NO CHANGE I AM AFR…

Read full complaint

INFORMATION REDACTED PURSUANT TO THE FREEDOM OF INFORMATION ACT (FOIA), 5 U.S.C. 552(B)(6) I OWN A 2009 CHEVY PICKUP WITH A EXTENDED CAB WHEN I DRIVE DOWN THE ROAD THE DOORS SHUTTER AND FEEL LIKE THEY ARE GOING TO OPEN THE DEALER IS SAYING THERE WAS A NATIONAL RECALL FOR STRIKER PLATES THEY PUT THEM ON WITH NO CHANGE I AM AFRAID TO PUT MY KIDS IN THIS TRUCK BECAUSE THE DOORS MIGHT OPEN AND GAS PEDAL DOESN'T SEEM TO RESPOND CORRECTLY [XXX] *TR

NHTSA ODI #10318795

2,000 miles · Mar 4, 2009
StructureCrash

I HAVE A 2009 CHEVY SILVERADO 1500 CREW 4X4. I RECENTLY HAD COLLISION BACKING OUT OF A PARKING SPACE. I COLLIDED WITH A TOYOTA CAMRY BACKING OUT OF A SPACE ON THE OPPOSITE SIDE AISLE. WE BASICALLY HIT REAR CORNER TO REAR CORNER. MY COMPLAINT IS THE EXTENT OF DAMAGE TO THE TRUCK ON SUCH A LOW SPEED COLLISION. VISUAL DAMA…

Read full complaint

I HAVE A 2009 CHEVY SILVERADO 1500 CREW 4X4. I RECENTLY HAD COLLISION BACKING OUT OF A PARKING SPACE. I COLLIDED WITH A TOYOTA CAMRY BACKING OUT OF A SPACE ON THE OPPOSITE SIDE AISLE. WE BASICALLY HIT REAR CORNER TO REAR CORNER. MY COMPLAINT IS THE EXTENT OF DAMAGE TO THE TRUCK ON SUCH A LOW SPEED COLLISION. VISUAL DAMAGE: RIGHT BUMPER END (3 PIECE OUTER BUMPER) IS BENT IN AND UP SLIGHTLY. REAR OF BED SIDE PANEL IS BENT IN AND UP SLIGHTLY REAR LIGHT IS CRACKED THERE IS A DENT(BUCKLE) IN THE BED SIDE PANEL ABOVE THE WHEEL WELL, ABOUT THE SIZE OF A HAND. 3 ESTIMATES: (1 DEALER, 1 PRIVATE SHOP, 1 GM PREFERRED COLLISION CENTER) PARTS NEEDED; NEW REAR BUMPER NEW BUMPER RE INFORCEMENT NEW TAIL LIGHT NEW TRUCK BED SIDE PANEL.(YES, THE WHOLE SIDE PANEL!) ESTIMATES FOR DAMAGE REPAIRS; $2600 DEALER $2600 PRIVATE $3200 GM AUTHORIZED COLLISION CENTER ABOUT 50/50 PARTS & LABOR THIS DOES NOT INCLUDE A TRAILER HITCH BRACE THAT IS MOST LIKELY BENT. DUE TO LIABILITY OF POTENTIAL FAILURE, ALL SAY IF THIS EVEN LOOKS DAMAGED, WILL REQUIRE REPLACEMENT. ADD $400. DEALER AND GM COLLISION CENTER GEN MGR SAY THE BUMPER DESIGN OF THE NEW SILVERADO BODY STYLE "SUCKS"! THE CENTER SECTION OF THE BUMPER CAN TAKE DIRECT, FLUSH IPACT JUST FINE. THE END SECTIONS WILL BE DESTROYED IN EVEN A LOW SPEED IMPACT. THE KILLER IS THE DAMAGE TO THE SIDE BED PANELS. BECAUSE THE REAR OF PANEL IS A SINGLE WALL OF SHEET METAL, UN REINFORCED, IT BUCKLES LIKE FABRIC AT EVEN THE LIGHTEST TOUCH. YOU COULD BEND IT IN BY HAND IF YOU PUSH HARD ENOUGH. SINCE THERE IS NO WAY TO PULL OUT THIS PANEL DUE TO ITS UN REINFORCED SHEET METAL DESIGN, THE MOST COST EFFECTIVE REPAIR IS TO REPLACE THE WHOLE PANEL. THEY SELL THE TRUCK CHEAP! THEY MAKE A FORTUNE ON REPLACEMENT PARTS BECAUSE OF THE CHEAP DESIGN QUALITY. WORD TO THE WISE: GET THE REAR BACKING SENSORS! IT WILL SAVE YOU $3000. IT WOULDN'T HELP IN MY CASE AS I STILL HAD ANOTHER MOVING VEHICLE. NO FAULT COLLISION. *TR

NHTSA ODI #10260734

Official recalls

3

21V050000 · Air Bags:frontal:passenger Side:inflator Module

Feb 5, 2021

General Motors, LLC (GM) is recalling certain 2007-2011 Cadillac Escalade, Escalade ESV, Escalade EXT, Chevrolet Avalanche, Silverado 1500, Suburban, Tahoe, GMC Sierra 1500, Yukon, Yukon XL, and 2009-2011 Chevrolet Silverado 2500, Silverado 3500, GMC Sierra 2500 and Sierra 3500 vehicles originally sold, or ever registered, in the states of Alabama, California, Florida, Georgia, Hawaii, Louisiana, Mississippi, South Carolina, Texas, Puerto Rico, American Samoa, Guam, the Northern Mariana Islands (Saipan), and the U.S. Virgin Islands or "Zone A." Additionally, GM is recalling certain 2007-2008 Cadillac Escalade, Escalade ESV, Escalade EXT, Chevrolet Avalanche, Silverado 1500, Suburban, Tahoe, GMC Sierra 1500, Yukon, Yukon XL vehicles originally sold, or ever registered, in the states of Arizona, Arkansas, Delaware, District of Columbia, Illinois, Indiana, Kansas, Kentucky, Maryland, Missouri, Nebraska, Nevada, New Jersey, New Mexico, North Carolina, Ohio, Oklahoma, Pennsylvania, Tennessee, Virginia, and West Virginia or "Zone B." These vehicles are equipped with non-desiccated passenger frontal inflators containing phase-stabilized ammonium nitrate (PSAN) propellant. These inflators may explode due to propellant degradation occurring after long-term exposure to high absolute humidity, high temperatures, and high temperature cycling.

Consequence & remedy

Consequence: An inflator explosion may result in sharp metal fragments striking the driver or other occupants, resulting in serious injury or death.

Remedy: GM will notify owners, and dealers will replace the front passenger air bag inflator with an alternate one, free of charge. Interim letters notifying owners of the safety risk were mailed on February 22, 2021. Second notification letters will be mailed once the remedy is available. Owner notification letters were mailed on March 1, 2021. Owners may contact Chevrolet customer service at 1-800-222-1020; Cadillac customer service at 1-800-458-8006; and GMC customer service at 1-800-462-8782. GM's number for this recall is N212328760.

21V052000 · Air Bags:frontal:passenger Side:inflator Module

Feb 5, 2021

General Motors, LLC (GM) is recalling certain 2009 Cadillac Escalade, Escalade ESV, Escalade EXT, Chevrolet Avalanche, Silverado 1500, Silverado 2500, Silverado 3500, Suburban, Tahoe, GMC Sierra 1500, Sierra 2500, Sierra 3500, Yukon, and Yukon XL vehicles originally sold, or ever registered, in the states of Arizona, Arkansas, Delaware, District of Columbia, Illinois, Indiana, Kansas, Kentucky, Maryland, Missouri, Nebraska, Nevada, New Jersey, New Mexico, North Carolina, Ohio, Oklahoma, Pennsylvania, Tennessee, Virginia, and West Virginia or "Zone B." Additionally, GM is recalling certain 2007-2008 Cadillac Escalade, Escalade ESV, and Escalade EXT, Chevrolet Avalanche, Silverado 1500, Suburban, Tahoe, GMC Sierra 1500, Yukon, and Yukon XL vehicles originally sold, or ever registered, in the states of Alaska, Colorado, Connecticut, Idaho, Iowa, Maine, Massachusetts, Michigan, Minnesota, Montana, New Hampshire, New York, North Dakota, Oregon, Rhode Island, South Dakota, Utah, Vermont, Washington, Wisconsin, and Wyoming or "Zone C." These vehicles are equipped with non-desiccated passenger frontal inflators containing phase-stabilized ammonium nitrate (PSAN) propellant. These inflators may explode due to propellant degradation occurring after long-term exposure to high absolute humidity, high temperatures, and high temperature cycling.

Consequence & remedy

Consequence: An inflator explosion may result in sharp metal fragments striking the driver or other occupants, resulting in serious injury or death.

Remedy: GM will notify owners, and dealers will replace the front passenger air bag inflator with an alternate one, free of charge. Interim letters notifying owners of the safety risk were mailed on February 23, 2021. Second notification letters will be mailed once the remedy is available. Owner notification letters were mailed on September 20, 2021. Owners may contact Chevrolet customer service at 1-800-222-1020, Cadillac customer service at 1-800-458-8006, and GMC customer service at 1-800-462-8782. GM's number for this recall is N212328780.

21V053000 · Air Bags:frontal:passenger Side:inflator Module

Feb 5, 2021

General Motors, LLC (GM) is recalling certain 2013 Cadillac Escalade, Escalade ESV, and Escalade EXT, Chevrolet Avalanche, Silverado 1500, Silverado 2500/3500, Suburban, Tahoe, GMC Sierra 1500, Sierra 2500/3500, Yukon, and Yukon XL vehicles originally sold, or ever registered, in the states of Alabama, California, Florida, Georgia, Hawaii, Louisiana, Mississippi, South Carolina, Texas, Puerto Rico, American Samoa, Guam, the Northern Mariana Islands (Saipan), and the U.S. Virgin Islands or "Zone A." Additionally, GM is recalling certain 2010 Cadillac Escalade, Escalade ESV, and Escalade EXT, Chevrolet Avalanche, Silverado 1500, Silverado 2500/3500, Suburban, Tahoe, GMC Sierra 1500, Sierra 2500/3500, Yukon, and Yukon XL vehicles originally sold, or ever registered in the states of Arizona, Arkansas, Delaware, District of Columbia, Illinois, Indiana, Kansas, Kentucky, Maryland, Missouri, Nebraska, Nevada, New Jersey, New Mexico, North Carolina, Ohio, Oklahoma, Pennsylvania, Tennessee, Virginia, and West Virginia or "Zone B." Additionally, GM is recalling certain 2009 Cadillac Escalade, Escalade ESV, and Escalade EXT, Chevrolet Avalanche, Silverado 1500, Silverado 2500/3500, Suburban, Tahoe, GMC Sierra 1500, Sierra 2500/3500, Yukon, and Yukon XL vehicles originally sold, or ever registered, in the states of Alaska, Colorado, Connecticut, Idaho, Iowa, Maine, Massachusetts, Michigan, Minnesota, Montana, New Hampshire, New York, North Dakota, Oregon, Rhode Island, South Dakota, Utah, Vermont, Washington, Wisconsin, and Wyoming or "Zone C."

Consequence & remedy

Consequence: An inflator explosion may result in sharp metal fragments striking the driver or other occupants, resulting in serious injury or death.

Remedy: GM will notify owners, and dealers will replace the front passenger air bag inflator with an alternate one, free of charge. Interim letters notifying owners of the safety risk were mailed on February 24, 2021. Second notification letters will be mailed once the remedy is available. Owner notification letters were mailed on May 11, 2021. Owners may contact Cadillac customer service at 1-800-458-8006; Chevrolet customer service at 1-800-222-1020; and GMC customer service at 1-800-462-8782. GM's number for this recall is N212328790.

Model-level recall history does not show whether a particular VIN is affected or has received a repair. Check a VIN with NHTSA ↗

NHTSA investigations

2

DP22005 · Pedestrian Alert Sounds

Opened Jan 27, 2023 · Closed Aug 7, 2023

Status: closed (inferred from source dates) · Electrical System:propulsion System

NHTSA received a petition on or about July 18, 2022, requesting that Federal Motor Vehicle Safety Standard (FMVSS) 141 be applied to all electric and hybrid vehicles operating in the United States. The petition can be reviewed at NHTSA.gov under ODI Number 11486072. FMVSS 141 establishes performance requirements for pedestrian alert sounds for motor vehicles. The standard applies to hybrid and electric vehicles that have a gross vehicle weight rating of 4,536 KG or less or are defined as low-speed vehicles. The standard became fully applicable to all such vehicles manufactured on or after March 1, 2021.On January 27, 2023, NHTSA opened Defect Petition (DP) 22-005 to evaluate the subject matter described in the petition. On June 24, 2023 and as supplemented on June 25, 2023, the petitioner notified NHTSA he was withdrawing his petition. The petitioner indicated that, based on his review of data, there is no justification for asserting potential benefits that could be derived from actions sought by my petition. Based on the petitioner's withdrawal, DP22-005 is closed. Closure of this DP does not represent a determination by NHTSA regarding the subject matter of the petition.

EA21002 · Desiccated Air Bag Inflator Rupture

Opened Sep 17, 2021 · No close date supplied

Status: open (inferred from source dates) · Air Bags:frontal:driver Side:inflator Module; Air Bags:frontal:passenger Side:inflator Module

From 2000 through 2017, Takata produced millions of air bag inflators using two types of phase-stabilized ammonium nitrate ("PSAN") propellant -- propellant 2004 and propellant 2004L. After prolonged exposure to high temperature cycles and humidity, inflators using propellant 2004 can degrade, causing the propellant to burn too quickly when ignited. The rapid burning can cause the inflator to rupture during deployment, potentially causing serious or even fatal injury to vehicle occupants. See 2016 Blomquist Report at www.nhtsa.gov/sites/nhtsa.gov/files/documents/expert_report-hrblomquist.pdf.Consequently, all frontal inflators using propellant 2004 that do not contain a "desiccant" (a substance that traps and holds moisture) in US vehicles are under recall. These "non-desiccated" inflators either have been or are required to be replaced.In some cases, the remedy part for these recalled inflators was, or will be, an inflator using either propellant 2004 or 2004L that does contain a desiccant. None of these "desiccated" remedy parts (which were installed in older model year vehicles) are currently under recall for a degradation concern. Certain subsets of desiccated PSAN inflators using propellant 2004 for use as original equipment, however, have been recalled for a degradation concern. All Takata inflators produced with propellant 2004L contain desiccant, and none of these desiccated inflators using propellant 2004L are under recall for a degradation concern. There have been no reported field ruptures in any non-recalled desiccated PSAN inflators.It is understood that desiccants fully saturate at some threshold, at which point any additional moisture will not be captured. This means the degradation process observed in non-desiccated inflators using propellant 2004 may also occur in non-recalled desiccated inflators using propellant 2004, assuming additional moisture enters the inflator and high temperature cycling occurs. Based on available information, desiccant saturation can occur within the first five years in the worst environments, and the time required for full saturation is affected by multiple factors. While no present safety risk has been identified, further work is needed to evaluate the future risk of non-recalled desiccated inflators using propellant 2004.Three entities -- Takata (now known as TK Global), the Independent Testing Coalition, and Exponent -- have been studying the long-term behavior of Takata desiccated PSAN inflators using propellant 2004L (as well as 2004) in the presence of moisture and temperature cycling. The research efforts, which include development of predictive modeling techniques and field sample analysis, are ongoing. To date, none of the researchers have identified field evidence showing that propellant 2004L is undergoing a degradation process that leads to aggressive deployment and potential rupture. However, the time in service of such inflators remains short compared to that of the inflators using propellant 2004. Further study is needed to assess the long-term safety of desiccated inflators using propellant 2004L.The Office of Defects Investigation is opening this investigation to examine whether a safety defect related to propellant degradation exists in non-recalled desiccated PSAN frontal inflators manufactured by Takata. This investigation will require extensive information on Takata production processes and surveys of inflators in the field. Lists of recall actions that may have used desiccated PSAN inflators as remedy parts, as well as the makes and models originally manufactured with them, is available with the downloadable version of this document (see nhtsa.gov/recalls?nhtsaId=EA21002 -- note this information is subject to change/revision as the investigation proceeds). This investigation does not supersede EA15-001, which remains open.

Additional source detail variants (2)

Air Bags:frontal:driver Side:inflator Module

From 2000 through 2017, Takata produced millions of air bag inflators using two types of phase-stabilized ammonium nitrate ("PSAN") propellant -- propellant 2004 and propellant 2004L. After prolonged exposure to high temperature cycles and humidity, inflators using propellant 2004 can degrade, causing the propellant to burn too quickly when ignited. The rapid burning can cause the inflator to rupture during deployment, potentially causing serious or even fatal injury to vehicle occupants. See 2016 Blomquist Report at www.nhtsa.gov/sites/nhtsa.gov/files/documents/expert_report-hrblomquist.pdf.Consequently, all frontal inflators using propellant 2004 that do not contain a "desiccant" (a substance that traps and holds moisture) in US vehicles are under recall. These "non-desiccated" inflators either have been or are required to be replaced.In some cases, the remedy part for these recalled inflators was, or will be, an inflator using either propellant 2004 or 2004L that does contain a desiccant. None of these "desiccated" remedy parts (which were installed in older model year vehicles) are currently under recall for a degradation concern. Certain subsets of desiccated PSAN inflators using propellant 2004 for use as original equipment, however, have been recalled for a degradation concern. All Takata inflators produced with propellant 2004L contain desiccant, and none of these desiccated inflators using propellant 2004L are under recall for a degradation concern. There have been no reported field ruptures in any non-recalled desiccated PSAN inflators.It is understood that desiccants fully saturate at some threshold, at which point any additional moisture will not be captured. This means the degradation process observed in non-desiccated inflators using propellant 2004 may also occur in non-recalled desiccated inflators using propellant 2004, assuming additional moisture enters the inflator and high temperature cycling occurs. Based on available information, desiccant saturation can occur within the first five years in the worst environments, and the time required for full saturation is affected by multiple factors. While no present safety risk has been identified, further work is needed to evaluate the future risk of non-recalled desiccated inflators using propellant 2004.Three entities -- Takata (now known as TK Global), the Independent Testing Coalition, and Exponent -- have been studying the long-term behavior of Takata desiccated PSAN inflators using propellant 2004L (as well as 2004) in the presence of moisture and temperature cycling. The research efforts, which include development of predictive modeling techniques and field sample analysis, are ongoing. To date, none of the researchers have identified field evidence showing that propellant 2004L is undergoing a degradation process that leads to aggressive deployment and potential rupture. However, the time in service of such inflators remains short compared to that of the inflators using propellant 2004. Further study is needed to assess the long-term safety of desiccated inflators using propellant 2004L.The Office of Defects Investigation is opening this investigation to examine whether a safety defect related to propellant degradation exists in non-recalled desiccated PSAN frontal inflators manufactured by Takata. This investigation will require extensive information on Takata production processes and surveys of inflators in the field. Lists of recall actions that may have used desiccated PSAN inflators as remedy parts, as well as the makes and models originally manufactured with them, is available with the downloadable version of this document (see nhtsa.gov/recalls?nhtsaId=EA21002 -- note this information is subject to change/revision as the investigation proceeds). This investigation does not supersede EA15-001, which remains open.

Air Bags:frontal:passenger Side:inflator Module

From 2000 through 2017, Takata produced millions of air bag inflators using two types of phase-stabilized ammonium nitrate ("PSAN") propellant -- propellant 2004 and propellant 2004L. After prolonged exposure to high temperature cycles and humidity, inflators using propellant 2004 can degrade, causing the propellant to burn too quickly when ignited. The rapid burning can cause the inflator to rupture during deployment, potentially causing serious or even fatal injury to vehicle occupants. See 2016 Blomquist Report at www.nhtsa.gov/sites/nhtsa.gov/files/documents/expert_report-hrblomquist.pdf.Consequently, all frontal inflators using propellant 2004 that do not contain a "desiccant" (a substance that traps and holds moisture) in US vehicles are under recall. These "non-desiccated" inflators either have been or are required to be replaced.In some cases, the remedy part for these recalled inflators was, or will be, an inflator using either propellant 2004 or 2004L that does contain a desiccant. None of these "desiccated" remedy parts (which were installed in older model year vehicles) are currently under recall for a degradation concern. Certain subsets of desiccated PSAN inflators using propellant 2004 for use as original equipment, however, have been recalled for a degradation concern. All Takata inflators produced with propellant 2004L contain desiccant, and none of these desiccated inflators using propellant 2004L are under recall for a degradation concern. There have been no reported field ruptures in any non-recalled desiccated PSAN inflators.It is understood that desiccants fully saturate at some threshold, at which point any additional moisture will not be captured. This means the degradation process observed in non-desiccated inflators using propellant 2004 may also occur in non-recalled desiccated inflators using propellant 2004, assuming additional moisture enters the inflator and high temperature cycling occurs. Based on available information, desiccant saturation can occur within the first five years in the worst environments, and the time required for full saturation is affected by multiple factors. While no present safety risk has been identified, further work is needed to evaluate the future risk of non-recalled desiccated inflators using propellant 2004.Three entities -- Takata (now known as TK Global), the Independent Testing Coalition, and Exponent -- have been studying the long-term behavior of Takata desiccated PSAN inflators using propellant 2004L (as well as 2004) in the presence of moisture and temperature cycling. The research efforts, which include development of predictive modeling techniques and field sample analysis, are ongoing. To date, none of the researchers have identified field evidence showing that propellant 2004L is undergoing a degradation process that leads to aggressive deployment and potential rupture. However, the time in service of such inflators remains short compared to that of the inflators using propellant 2004. Further study is needed to assess the long-term safety of desiccated inflators using propellant 2004L.The Office of Defects Investigation is opening this investigation to examine whether a safety defect related to propellant degradation exists in non-recalled desiccated PSAN frontal inflators manufactured by Takata. This investigation will require extensive information on Takata production processes and surveys of inflators in the field. Lists of recall actions that may have used desiccated PSAN inflators as remedy parts, as well as the makes and models originally manufactured with them, is available with the downloadable version of this document (see nhtsa.gov/recalls?nhtsaId=EA21002 -- note this information is subject to change/revision as the investigation proceeds). This investigation does not supersede EA15-001, which remains open.