TL* THE CONTACT OWNS A 2017 NISSAN TITAN. WHEN THE VEHICLE WAS STARTED, A SPARK APPEARED FROM THE ENGINE COMPARTMENT. THE VEHICLE WAS TAKEN TO SISK NISSAN (10800 EAGLE WAY, HOPKINSVILLE, KY 42240, 270-886-6681) WHERE IT WAS DIAGNOSED THAT THE VEHICLE HAD NORMAL WEAR AND TEAR. THE VEHICLE WAS NOT REPAIRED. THE MANUFACTURER WAS NO…
Read full complaint
TL* THE CONTACT OWNS A 2017 NISSAN TITAN. WHEN THE VEHICLE WAS STARTED, A SPARK APPEARED FROM THE ENGINE COMPARTMENT. THE VEHICLE WAS TAKEN TO SISK NISSAN (10800 EAGLE WAY, HOPKINSVILLE, KY 42240, 270-886-6681) WHERE IT WAS DIAGNOSED THAT THE VEHICLE HAD NORMAL WEAR AND TEAR. THE VEHICLE WAS NOT REPAIRED. THE MANUFACTURER WAS NOT NOTIFIED OF THE FAILURE. THE FAILURE MILEAGE WAS 14,000. *DT CONSUMER STATED MANUFACTURER WAS NOTIFIED AND REQUESTED TO BUY BACK DUE TO NO FIX OR RECALL BUT NISSAN DENIED TO BUY BACK OR REPLACE CLAIM.*JB
NHTSA ODI #11171597
150 miles · Aug 7, 2018
Electrical SystemEngineVehicle Speed Control
THIS IS THE SECOND TITAN XD WITH THE SAME ISSUE "DEAD PEDAL" OR NO ACCELERATION WHEN PEDAL IS PRESSED THIS IS WHEN THE TRUCK IS BEING DRIVEN AT VARIOUS SPEEDS. NISSAN HAS ATTEMPTED TO FIX WITH NO KNOW REPAIRS AT THIS TIME.
NHTSA ODI #11118350
500 miles · May 1, 2018
Electrical SystemEngine
TL* THE CONTACT OWNS A 2017 NISSAN TITAN. THE CONTACT STATED THAT THERE WAS AN ODOR OF ANTI-FREEZE IN THE VEHICLE. THE CONTACT STATED THAT TWO DIFFERENT DEALERS: BENTON NISSAN OF HOOVER (1640 MONTGOMERY HWY, HOOVER, AL 35216, (205) 938-6103) AND JACK INGRAM NISSAN (227 EASTERN BLVD, MONTGOMERY, AL 36117, (334) 270-6000) WERE UNA…
Read full complaint
TL* THE CONTACT OWNS A 2017 NISSAN TITAN. THE CONTACT STATED THAT THERE WAS AN ODOR OF ANTI-FREEZE IN THE VEHICLE. THE CONTACT STATED THAT TWO DIFFERENT DEALERS: BENTON NISSAN OF HOOVER (1640 MONTGOMERY HWY, HOOVER, AL 35216, (205) 938-6103) AND JACK INGRAM NISSAN (227 EASTERN BLVD, MONTGOMERY, AL 36117, (334) 270-6000) WERE UNABLE TO REPLICATE AND DIAGNOSE THE FAILURE. THE VEHICLE WAS NOT REPAIRED. THE CONTACT WAS UNCERTAIN IF THERE WAS AN INTERNAL FAILURE OR A LEAK THAT COULD PROGRESS DUE TO THE STRONG ODOR. THE MANUFACTURER WAS NOTIFIED OF THE FAILURE. THE VIN WAS NOT AVAILABLE. THE FAILURE MILEAGE WAS APPROXIMATELY 500.
NHTSA ODI #11091187
17,900 miles · Mar 27, 2018
EngineFuel System, Diesel
TO WHOM IT MAY CONCERN I WAS DRIVING WITH SLIGHTLY LESS THAN 1/4 TANK OF GAS AND STOPPED TO PARK ON A HILL WITH VEHICLE ON IDLE. WHILE IN IDLE ON THE HILL THE VEHICLE STALLED OUT. I TRIED TO RESTART BUT THE ENGINE JUST CRANKED WITH NO START AND A LOW PRESSURE FUEL SYSTEM SERVICE LIGHT CAME ON. I TRIED TO PUSH IT DOWN THE H…
Read full complaint
TO WHOM IT MAY CONCERN I WAS DRIVING WITH SLIGHTLY LESS THAN 1/4 TANK OF GAS AND STOPPED TO PARK ON A HILL WITH VEHICLE ON IDLE. WHILE IN IDLE ON THE HILL THE VEHICLE STALLED OUT. I TRIED TO RESTART BUT THE ENGINE JUST CRANKED WITH NO START AND A LOW PRESSURE FUEL SYSTEM SERVICE LIGHT CAME ON. I TRIED TO PUSH IT DOWN THE HILL ON FLAT GROUND AND TRIED TO START AGAIN WITH JUST CRANKING NO START. I THEN HAD TO PUSH THE VEHICLE WITH THE HELP OF MY NEIGHBORS INTO A GUEST STALL AND CALL FOR A TOW. THE VEHICLE WAS TOWED TO TONY NISSAN TO BE LOOKED AT WHERE THE MECHANIC SAID THAT THERE WERE NO ISSUES AND HE REVIEWED ALL THE FUEL SYSTEM AND NO ISSUES WERE FOUND. HE INFORMED ME HE LET THE VEHICLE CRANK OVER UNTIL THE PUMP WAS ABLE TO PICK UP FUEL AND PURGE THE LINE OF AIR AND THE CAR STARTED. THE SERVICE ADVISOR INFORMED ME OF THE FUEL TANK BEING LONGITUDINALLY PLACED IN THE TRUCK WITH FUEL PUMP IN THE CENTER WHICH STOPPED TO IDLE ON A HILL MAY HAVE CAUSED THE PUMP TO GO DRY AND PUMP AIR. I INFORMED HIM THAT THIS COULD BE AN ISSUE IF I WAS DRIVING UP OR DOWN A HILL WITH MY FAMILY AND THEN STOP AND IDLE WHEREBY THE TRUCK STALLS OUT ON A HILL OF SUCH MAGNITUDE LIKE IN SAN FRANCISCO OR WILHEMINA RISE IN HONOLULU, HI. HOPEFULLY THIS IS REVIEWED BY THE ENGINEERS AT NISSAN MOTOR WHICH THIS EMAIL IS ALSO BEING FORWARDED TO NHTSA. INVOICE NUMBER, I BELIEVE, FROM TONY NISSAN IS 653922. *TR
NHTSA ODI #11081513
5,000 miles · Feb 22, 2018
Engine
ON FEB 16 2018 I WAS DRIVING MY 2017 NISSAN TITAN TRUCK WITH 5000 MILES ON THE ODOMETER ALONG A RURAL TWO LANE ROAD IN MISSOURI WITH THREE OTHER PASSENGERS RIDING WITH ME. WE HEARD A NOISE FROM THE ENGINE COMPARTMENT AND SUDDENLY THE POWER STEERING OF THE VEHICLE CEASED TO OPERATE AND THE TRUCK DRIFTED ACROSS THE DOUBLE YELLOW L…
Read full complaint
ON FEB 16 2018 I WAS DRIVING MY 2017 NISSAN TITAN TRUCK WITH 5000 MILES ON THE ODOMETER ALONG A RURAL TWO LANE ROAD IN MISSOURI WITH THREE OTHER PASSENGERS RIDING WITH ME. WE HEARD A NOISE FROM THE ENGINE COMPARTMENT AND SUDDENLY THE POWER STEERING OF THE VEHICLE CEASED TO OPERATE AND THE TRUCK DRIFTED ACROSS THE DOUBLE YELLOW LINES OF THE HIGHWAY. LUCKILY NO CARS WERE COMING IN THE OPPOSITE DIRECTION AND I STEERED HARD TO THE RIGHT AND SLOWED THE VEHICLE DOWN RAPIDLY. I DROVE A SHORT DISTANCE TO A GRAVEL PARKING LOT OF A CHURCH AND WE EXAMINED THE VEHICLE AND COULD SEE THE SERPENTINE BELT WAS NO LONGER IN PLACE. THE TRUCK WAS TOWED TO A NISSAN DEALERSHIP 55 MILES AWAY AND WE AWAITED THEIR REPORT. SEVERAL DAYS LATER I WAS INFORMED THAT THE BELT TENSIONER BRACKET HAD BROKEN IN HALF AND NISSAN WAS GOING TO ORDER PARTS AS THEY WERE NOT IN STOCK AT THE DEALER. REMEMBER THIS IS A NEW 2017 TRUCK WITH ONLY 5000 MILES ON IT. THE SERPENTINE BELT RUNS ALL ASPECTS OF THE VEHICLE AND WITHOUT IT ENGAGED THE VEHICLE BECOMES UNDRIVEABLE. THE VEHICLE IS COMPLETELY STOCK WITH NO MODIFICATIONS OF ANY KIND. THE NISSAN DEALERSHIP ADVISED ME THAT I WAS THE ONLY PERSON IN THE U.S. WITH THIS MALFUNCTION TO DATE. THIS PROBLEM COULD POTENTIALLY KILL.
NHTSA ODI #11074262
500 miles · Feb 6, 2018
Engine
WHEN THE DIESEL ENGINE GOES INTO DPF REGENERATION MODE, THE CAB OF THE VEHICLE FILLS WITH UNPLEASANT FUMES THAT SMELL LIKE EVAPORATED DIESEL FUEL OR OTHER NOXIOUS SUBSTANCE THAT IS IRRITATING TO MUCOUS MEMBRANES AND MAY CAUSE HEALTH ISSUES. THE PROBLEM IS WORSE WHEN THE VEHICLE IS AT LOW SPEED OR IN STOP-AND-GO TRAFFIC WHEN EXHA…
Read full complaint
WHEN THE DIESEL ENGINE GOES INTO DPF REGENERATION MODE, THE CAB OF THE VEHICLE FILLS WITH UNPLEASANT FUMES THAT SMELL LIKE EVAPORATED DIESEL FUEL OR OTHER NOXIOUS SUBSTANCE THAT IS IRRITATING TO MUCOUS MEMBRANES AND MAY CAUSE HEALTH ISSUES. THE PROBLEM IS WORSE WHEN THE VEHICLE IS AT LOW SPEED OR IN STOP-AND-GO TRAFFIC WHEN EXHAUST FUMES ARE ABLE TO COLLECT AROUND THE VEHICLE. THE MOST RECENT INSTANCE OCCURRED IN A DRIVE-THRU LINE AT A FAST FOOD RESTAURANT, AND WAS SO PUNGENT THAT I WAS FORCED TO ABANDON THE LINE, PARK THE VEHICLE, AND EVACUATE MYSELF TO FRESH AIR.
NHTSA ODI #11067173
2,600 miles · Jan 13, 2018
Engine
THE TRUCK I HAVE PURCHASED ON NOV 24TH, 2017 HAS THE CUMMINGS DIESEL ENGINE. THE TRUCK IS KNOWN NOT TO START IN WEATHER BELOW 12 DEGREES F. NISSAN TECHS TELL ME NOW (AFTER THE SALE) THAT THIS ENGINE NEEDS AN ANTI FUEL GELL ADDIDATIVE IN ORDER FOR THE VEHICLE TO START IN COLD W…
Read full complaint
THE TRUCK I HAVE PURCHASED ON NOV 24TH, 2017 HAS THE CUMMINGS DIESEL ENGINE. THE TRUCK IS KNOWN NOT TO START IN WEATHER BELOW 12 DEGREES F. NISSAN TECHS TELL ME NOW (AFTER THE SALE) THAT THIS ENGINE NEEDS AN ANTI FUEL GELL ADDIDATIVE IN ORDER FOR THE VEHICLE TO START IN COLD WEATHER. I FEEL I HAVE BEEN ROBBED OF THE $50,645 I SPENT ON A NEW VEHICLE. THIS IS NOT AT ALL AN ACCEPTABLE ANSWER TO ME. I HAVE A 2005 CHEVROLET K3500 WITH A CHEVROLET DURAMAX DIESEL THAT IN 12 3/4 YEARS HAS NOT HAD ONE DROP OF ANTI GEL FLUID PLACED IN IT, & HAS NEVER FAILED TO START NOT ONE SINGLE TIME WITH 235,000 MILES ON IT!!! I FIND THIS UNACCEPTABLE, & DEMAND SOME SORT OF ACTION BE TAKEN. I BOUGHT A VEHICLE IN THE GOOD FAITH IT WAS GOING TO LAST. INSTEAD I HAVE BOUGHT SOMETHING I HATE NOW; NEVER KNOWING WEATHER OR NOT IT WILL START. VEHICLE HAS FAILED TO START ON MULTIPLE DAYS. ABOUT 6 DAYS TOTAL SO FAR SINCE CHRISTMAS OF 2017. FILLED A CASE #: 29386597... NISSAN CLOSED IT AFTER SAYING THERE WAS NOTHING THEY COULD DO! ALSO FILLING A COMPLAINT WITH THE INDIANA STATE ATTORNEY GENERAL, & BBB!
NHTSA ODI #11062537
Mileage unknown · May 20, 2017
EngineFuel/propulsion SystemUnknown Or Other
VERY SOON AFTER I PURCHASED THE TITAN TRUCK, RANDOMLY, WHILE THE CAR SITS IDLE OR WHILE DRIVING THE TRUCK ANYWHERE (I.E. ON CITY STREETS, ON THE HIGHWAY, IN MY NEIGHBORHOOD) THE TRUCK PRODUCES A STRONG SCENT OF DIESEL MIXTURE/EXHAUST FUMES IN THE CABIN OF THE TRUCK. THE FUMES ARE SO STRONG IT MAKES ME DIZZY. THE DIESEL FUMES/E…
Read full complaint
VERY SOON AFTER I PURCHASED THE TITAN TRUCK, RANDOMLY, WHILE THE CAR SITS IDLE OR WHILE DRIVING THE TRUCK ANYWHERE (I.E. ON CITY STREETS, ON THE HIGHWAY, IN MY NEIGHBORHOOD) THE TRUCK PRODUCES A STRONG SCENT OF DIESEL MIXTURE/EXHAUST FUMES IN THE CABIN OF THE TRUCK. THE FUMES ARE SO STRONG IT MAKES ME DIZZY. THE DIESEL FUMES/EXHAUST SMELL IN THE CABIN WHEN THE DEF CYCLE IS ON AS WELL. I'VE TAKEN IT TO A NISSAN DEALERSHIP AT LEAST FOUR TIMES TO NO AVAIL AT REPAIRING IT. I BOUGHT THIS TRUCK AS A NEW CAR.
Nissan North America, Inc. (Nissan) is recalling certain 2017-2019 gasoline, light duty, Titan vehicles. The alternator harness may have been damaged during the engine installation process, possibly resulting in an electrical short.
Consequence & remedy
Consequence: An electrical short may cause an engine stall, increasing the risk of a crash. In addition, it increases the risk of a fire.
Remedy: Nissan will notify owners, and dealers will inspect the alternator harness for the proper routing and any damage. The harness will be clipped into the correct position or replaced as necessary, free of charge. The recall began August 8, 2019. Owners may contact Nissan customer service at 1-800-867-7669.
Additional source detail variants (2)
Electrical System:wiring
Nissan North America, Inc. (Nissan) is recalling certain 2017-2019 gasoline, light duty, Titan vehicles. The alternator harness may have been damaged during the engine installation process, possibly resulting in an electrical short.
Consequence: An electrical short may cause an engine stall, increasing the risk of a crash. In addition, it increases the risk of a fire.
Remedy: Nissan will notify owners, and dealers will inspect the alternator harness for the proper routing and any damage. The harness will be clipped into the correct position or replaced as necessary, free of charge. The recall began August 8, 2019. Owners may contact Nissan customer service at 1-800-867-7669.
Electrical System:alternator/generator/regulator
Nissan North America, Inc. (Nissan) is recalling certain 2017-2019 gasoline, light duty, Titan vehicles. The alternator harness may have been damaged during the engine installation process, possibly resulting in an electrical short.
Consequence: An electrical short may cause an engine stall, increasing the risk of a crash. In addition, it increases the risk of a fire.
Remedy: Nissan will notify owners, and dealers will inspect the alternator harness for the proper routing and any damage. The harness will be clipped into the correct position or replaced as necessary, free of charge. The recall began August 8, 2019. Owners may contact Nissan customer service at 1-800-867-7669.
Nissan North America, Inc. (Nissan) is recalling certain 2016-2018 Nissan Titan, 2016 and 2018 Nissan Titan XD vehicles. Accessories installed on these vehicles reduced the load carrying capacity, however, a Load Carrying Capacity modification label was not installed, possibly allowing the vehicle to be overloaded. As such, these vehicles fail to comply with the requirements of Federal Motor Vehicle Safety Standard (FMVSS) number 110, "Tire Selection and Rims."
Consequence & remedy
Consequence: An overloaded vehicle can increase the risk of a crash.
Remedy: Nissan will notify owners and provide a new modification label, with installation instructions, free of charge. The recall began on June 4, 2018. Owners may contact Nissan customer service at 1-800-867-7669.
Nissan North America, Inc. (Nissan) is recalling certain 2016-2017 Nissan Titan Crew Cab and Titan XD Crew Cab vehicles. In the event of a crash, the rear seatbelt assembly may not adequately protect the occupant's head, allowing it to contact the D-ring bolt trim cap. As such, these vehicles fail to conform to Federal Motor Vehicle Safety Standard (FMVSS) number 201, "Occupant Protection in Interior Impact."
Consequence & remedy
Consequence: If the occupant's head contacts the D-ring bolt trim cap during a crash, there is an increased risk of injury.
Remedy: Nissan will notify owners, and dealers will install energy absorbing material to the C-Pillar Finishers and replace the Seatbelt Bolt and Bolt Cap, free of charge. The recall began September 19, 2017. Owners may contact Nissan customer service at 1-800-647-7261.
Model-level recall history does not show whether a particular VIN is affected or has received a repair. Check a VIN with NHTSA ↗
NHTSA investigations
2
PE23020 · Loss Of Motive Power Due To Broken Crankshaft With No Ability To Restart.
Opened Nov 15, 2023 · Closed Jun 27, 2025
Status: closed (inferred from source dates) · Engine; Engine And Engine Cooling:engine:diesel
On November 15, 2023, the Office of Defects Investigation (ODI) opened Preliminary Evaluation PE23020 to investigate allegations of loss of motive power in model year (MY) 2016 through 2019 Nissan Titan XD trucks equipped with 5.0L Cummins diesel engines. The complaints allege the condition was due to a failure of the engine crankshaft. The purpose of the investigation was to understand the scope, frequency, and safety related consequence of the alleged defect. During the investigation, it was found that the subject vehicles can experience a loss of motive power due to a failure of the crankshaft main bearings which can lead to a fractured crankshaft. This resulted in a loss of motive power and an inability to restart. An analysis of all complaint sources shows many vehicles exhibit knocking, vibration, malfunction indicator lamp (MIL) warnings, and/or poor engine performance prior to a total failure. Some consumers report driving their truck in for repairs only to be diagnosed with a failed crankshaft. ODI has not identified any injuries or fires attributable to this failure. ODI is aware of one complaint alleging a non-injury crash involving a curb strike. ODI is also aware of complaints of overheating starter motors and melted starter motor wiring occurring after prolonged attempts to start engines that have suffered a broken crankshaft. In its response to ODI's January 26, 2024 information request letter, Nissan provided information detailing several material and process changes involved in the production of the subject vehicle’s engine.These changes appear to coincide with incremental improvements in failure rates but there is no indication that a single factor was the primary cause of the failures. Analysis of ODI consumer complaints and manufacturer provided data found that failure rates decreased progressively for each model year. Review of failure mileage found that 50% of the failures occurred by 60,000 miles with a significant decrease in failures after 80,000 miles. Assuming average yearly mileage driven, the newest model year trucks (2019) would be near or past peak failure mileage. Given the low failure rate, the observable warnings available to the driver, and much of the fleet being past peak failure mileage, ODI is closing this Preliminary Evaluation with no further action. The closing of the investigation does not constitute a finding by NHTSA that a defect does not exist, and NHTSA will take further action if warranted by future circumstances. To review the ODI reports cited in the Closing Resume ODI Report Identification Number document, go to NHTSA.gov.
Additional source detail variants (2)
Engine And Engine Cooling:engine:diesel
On November 15, 2023, the Office of Defects Investigation (ODI) opened Preliminary Evaluation PE23020 to investigate allegations of loss of motive power in model year (MY) 2016 through 2019 Nissan Titan XD trucks equipped with 5.0L Cummins diesel engines. The complaints allege the condition was due to a failure of the engine crankshaft. The purpose of the investigation was to understand the scope, frequency, and safety related consequence of the alleged defect. During the investigation, it was found that the subject vehicles can experience a loss of motive power due to a failure of the crankshaft main bearings which can lead to a fractured crankshaft. This resulted in a loss of motive power and an inability to restart. An analysis of all complaint sources shows many vehicles exhibit knocking, vibration, malfunction indicator lamp (MIL) warnings, and/or poor engine performance prior to a total failure. Some consumers report driving their truck in for repairs only to be diagnosed with a failed crankshaft. ODI has not identified any injuries or fires attributable to this failure. ODI is aware of one complaint alleging a non-injury crash involving a curb strike. ODI is also aware of complaints of overheating starter motors and melted starter motor wiring occurring after prolonged attempts to start engines that have suffered a broken crankshaft. In its response to ODI's January 26, 2024 information request letter, Nissan provided information detailing several material and process changes involved in the production of the subject vehicle’s engine.These changes appear to coincide with incremental improvements in failure rates but there is no indication that a single factor was the primary cause of the failures. Analysis of ODI consumer complaints and manufacturer provided data found that failure rates decreased progressively for each model year. Review of failure mileage found that 50% of the failures occurred by 60,000 miles with a significant decrease in failures after 80,000 miles. Assuming average yearly mileage driven, the newest model year trucks (2019) would be near or past peak failure mileage. Given the low failure rate, the observable warnings available to the driver, and much of the fleet being past peak failure mileage, ODI is closing this Preliminary Evaluation with no further action. The closing of the investigation does not constitute a finding by NHTSA that a defect does not exist, and NHTSA will take further action if warranted by future circumstances. To review the ODI reports cited in the Closing Resume ODI Report Identification Number document, go to NHTSA.gov.
Engine
On November 15, 2023, the Office of Defects Investigation (ODI) opened Preliminary Evaluation PE23020 to investigate allegations of loss of motive power in model year (MY) 2016 through 2019 Nissan Titan XD trucks equipped with 5.0L Cummins diesel engines. The complaints allege the condition was due to a failure of the engine crankshaft. The purpose of the investigation was to understand the scope, frequency, and safety related consequence of the alleged defect. During the investigation, it was found that the subject vehicles can experience a loss of motive power due to a failure of the crankshaft main bearings which can lead to a fractured crankshaft. This resulted in a loss of motive power and an inability to restart. An analysis of all complaint sources shows many vehicles exhibit knocking, vibration, malfunction indicator lamp (MIL) warnings, and/or poor engine performance prior to a total failure. Some consumers report driving their truck in for repairs only to be diagnosed with a failed crankshaft. ODI has not identified any injuries or fires attributable to this failure. ODI is aware of one complaint alleging a non-injury crash involving a curb strike. ODI is also aware of complaints of overheating starter motors and melted starter motor wiring occurring after prolonged attempts to start engines that have suffered a broken crankshaft. In its response to ODI's January 26, 2024 information request letter, Nissan provided information detailing several material and process changes involved in the production of the subject vehicle’s engine.These changes appear to coincide with incremental improvements in failure rates but there is no indication that a single factor was the primary cause of the failures. Analysis of ODI consumer complaints and manufacturer provided data found that failure rates decreased progressively for each model year. Review of failure mileage found that 50% of the failures occurred by 60,000 miles with a significant decrease in failures after 80,000 miles. Assuming average yearly mileage driven, the newest model year trucks (2019) would be near or past peak failure mileage. Given the low failure rate, the observable warnings available to the driver, and much of the fleet being past peak failure mileage, ODI is closing this Preliminary Evaluation with no further action. The closing of the investigation does not constitute a finding by NHTSA that a defect does not exist, and NHTSA will take further action if warranted by future circumstances. To review the ODI reports cited in the Closing Resume ODI Report Identification Number document, go to NHTSA.gov.
EA21002 · Desiccated Air Bag Inflator Rupture
Opened Sep 17, 2021 · No close date supplied
Status: open (inferred from source dates) · Air Bags:frontal:driver Side:inflator Module; Air Bags:frontal:passenger Side:inflator Module
From 2000 through 2017, Takata produced millions of air bag inflators using two types of phase-stabilized ammonium nitrate ("PSAN") propellant -- propellant 2004 and propellant 2004L. After prolonged exposure to high temperature cycles and humidity, inflators using propellant 2004 can degrade, causing the propellant to burn too quickly when ignited. The rapid burning can cause the inflator to rupture during deployment, potentially causing serious or even fatal injury to vehicle occupants. See 2016 Blomquist Report at www.nhtsa.gov/sites/nhtsa.gov/files/documents/expert_report-hrblomquist.pdf.Consequently, all frontal inflators using propellant 2004 that do not contain a "desiccant" (a substance that traps and holds moisture) in US vehicles are under recall. These "non-desiccated" inflators either have been or are required to be replaced.In some cases, the remedy part for these recalled inflators was, or will be, an inflator using either propellant 2004 or 2004L that does contain a desiccant. None of these "desiccated" remedy parts (which were installed in older model year vehicles) are currently under recall for a degradation concern. Certain subsets of desiccated PSAN inflators using propellant 2004 for use as original equipment, however, have been recalled for a degradation concern. All Takata inflators produced with propellant 2004L contain desiccant, and none of these desiccated inflators using propellant 2004L are under recall for a degradation concern. There have been no reported field ruptures in any non-recalled desiccated PSAN inflators.It is understood that desiccants fully saturate at some threshold, at which point any additional moisture will not be captured. This means the degradation process observed in non-desiccated inflators using propellant 2004 may also occur in non-recalled desiccated inflators using propellant 2004, assuming additional moisture enters the inflator and high temperature cycling occurs. Based on available information, desiccant saturation can occur within the first five years in the worst environments, and the time required for full saturation is affected by multiple factors. While no present safety risk has been identified, further work is needed to evaluate the future risk of non-recalled desiccated inflators using propellant 2004.Three entities -- Takata (now known as TK Global), the Independent Testing Coalition, and Exponent -- have been studying the long-term behavior of Takata desiccated PSAN inflators using propellant 2004L (as well as 2004) in the presence of moisture and temperature cycling. The research efforts, which include development of predictive modeling techniques and field sample analysis, are ongoing. To date, none of the researchers have identified field evidence showing that propellant 2004L is undergoing a degradation process that leads to aggressive deployment and potential rupture. However, the time in service of such inflators remains short compared to that of the inflators using propellant 2004. Further study is needed to assess the long-term safety of desiccated inflators using propellant 2004L.The Office of Defects Investigation is opening this investigation to examine whether a safety defect related to propellant degradation exists in non-recalled desiccated PSAN frontal inflators manufactured by Takata. This investigation will require extensive information on Takata production processes and surveys of inflators in the field. Lists of recall actions that may have used desiccated PSAN inflators as remedy parts, as well as the makes and models originally manufactured with them, is available with the downloadable version of this document (see nhtsa.gov/recalls?nhtsaId=EA21002 -- note this information is subject to change/revision as the investigation proceeds). This investigation does not supersede EA15-001, which remains open.
Additional source detail variants (2)
Air Bags:frontal:driver Side:inflator Module
From 2000 through 2017, Takata produced millions of air bag inflators using two types of phase-stabilized ammonium nitrate ("PSAN") propellant -- propellant 2004 and propellant 2004L. After prolonged exposure to high temperature cycles and humidity, inflators using propellant 2004 can degrade, causing the propellant to burn too quickly when ignited. The rapid burning can cause the inflator to rupture during deployment, potentially causing serious or even fatal injury to vehicle occupants. See 2016 Blomquist Report at www.nhtsa.gov/sites/nhtsa.gov/files/documents/expert_report-hrblomquist.pdf.Consequently, all frontal inflators using propellant 2004 that do not contain a "desiccant" (a substance that traps and holds moisture) in US vehicles are under recall. These "non-desiccated" inflators either have been or are required to be replaced.In some cases, the remedy part for these recalled inflators was, or will be, an inflator using either propellant 2004 or 2004L that does contain a desiccant. None of these "desiccated" remedy parts (which were installed in older model year vehicles) are currently under recall for a degradation concern. Certain subsets of desiccated PSAN inflators using propellant 2004 for use as original equipment, however, have been recalled for a degradation concern. All Takata inflators produced with propellant 2004L contain desiccant, and none of these desiccated inflators using propellant 2004L are under recall for a degradation concern. There have been no reported field ruptures in any non-recalled desiccated PSAN inflators.It is understood that desiccants fully saturate at some threshold, at which point any additional moisture will not be captured. This means the degradation process observed in non-desiccated inflators using propellant 2004 may also occur in non-recalled desiccated inflators using propellant 2004, assuming additional moisture enters the inflator and high temperature cycling occurs. Based on available information, desiccant saturation can occur within the first five years in the worst environments, and the time required for full saturation is affected by multiple factors. While no present safety risk has been identified, further work is needed to evaluate the future risk of non-recalled desiccated inflators using propellant 2004.Three entities -- Takata (now known as TK Global), the Independent Testing Coalition, and Exponent -- have been studying the long-term behavior of Takata desiccated PSAN inflators using propellant 2004L (as well as 2004) in the presence of moisture and temperature cycling. The research efforts, which include development of predictive modeling techniques and field sample analysis, are ongoing. To date, none of the researchers have identified field evidence showing that propellant 2004L is undergoing a degradation process that leads to aggressive deployment and potential rupture. However, the time in service of such inflators remains short compared to that of the inflators using propellant 2004. Further study is needed to assess the long-term safety of desiccated inflators using propellant 2004L.The Office of Defects Investigation is opening this investigation to examine whether a safety defect related to propellant degradation exists in non-recalled desiccated PSAN frontal inflators manufactured by Takata. This investigation will require extensive information on Takata production processes and surveys of inflators in the field. Lists of recall actions that may have used desiccated PSAN inflators as remedy parts, as well as the makes and models originally manufactured with them, is available with the downloadable version of this document (see nhtsa.gov/recalls?nhtsaId=EA21002 -- note this information is subject to change/revision as the investigation proceeds). This investigation does not supersede EA15-001, which remains open.
Air Bags:frontal:passenger Side:inflator Module
From 2000 through 2017, Takata produced millions of air bag inflators using two types of phase-stabilized ammonium nitrate ("PSAN") propellant -- propellant 2004 and propellant 2004L. After prolonged exposure to high temperature cycles and humidity, inflators using propellant 2004 can degrade, causing the propellant to burn too quickly when ignited. The rapid burning can cause the inflator to rupture during deployment, potentially causing serious or even fatal injury to vehicle occupants. See 2016 Blomquist Report at www.nhtsa.gov/sites/nhtsa.gov/files/documents/expert_report-hrblomquist.pdf.Consequently, all frontal inflators using propellant 2004 that do not contain a "desiccant" (a substance that traps and holds moisture) in US vehicles are under recall. These "non-desiccated" inflators either have been or are required to be replaced.In some cases, the remedy part for these recalled inflators was, or will be, an inflator using either propellant 2004 or 2004L that does contain a desiccant. None of these "desiccated" remedy parts (which were installed in older model year vehicles) are currently under recall for a degradation concern. Certain subsets of desiccated PSAN inflators using propellant 2004 for use as original equipment, however, have been recalled for a degradation concern. All Takata inflators produced with propellant 2004L contain desiccant, and none of these desiccated inflators using propellant 2004L are under recall for a degradation concern. There have been no reported field ruptures in any non-recalled desiccated PSAN inflators.It is understood that desiccants fully saturate at some threshold, at which point any additional moisture will not be captured. This means the degradation process observed in non-desiccated inflators using propellant 2004 may also occur in non-recalled desiccated inflators using propellant 2004, assuming additional moisture enters the inflator and high temperature cycling occurs. Based on available information, desiccant saturation can occur within the first five years in the worst environments, and the time required for full saturation is affected by multiple factors. While no present safety risk has been identified, further work is needed to evaluate the future risk of non-recalled desiccated inflators using propellant 2004.Three entities -- Takata (now known as TK Global), the Independent Testing Coalition, and Exponent -- have been studying the long-term behavior of Takata desiccated PSAN inflators using propellant 2004L (as well as 2004) in the presence of moisture and temperature cycling. The research efforts, which include development of predictive modeling techniques and field sample analysis, are ongoing. To date, none of the researchers have identified field evidence showing that propellant 2004L is undergoing a degradation process that leads to aggressive deployment and potential rupture. However, the time in service of such inflators remains short compared to that of the inflators using propellant 2004. Further study is needed to assess the long-term safety of desiccated inflators using propellant 2004L.The Office of Defects Investigation is opening this investigation to examine whether a safety defect related to propellant degradation exists in non-recalled desiccated PSAN frontal inflators manufactured by Takata. This investigation will require extensive information on Takata production processes and surveys of inflators in the field. Lists of recall actions that may have used desiccated PSAN inflators as remedy parts, as well as the makes and models originally manufactured with them, is available with the downloadable version of this document (see nhtsa.gov/recalls?nhtsaId=EA21002 -- note this information is subject to change/revision as the investigation proceeds). This investigation does not supersede EA15-001, which remains open.
2017 Nissan Titan Problems, Complaints & Recalls | Skip That Year