← New search

2006 Nissan Titan

Owner reports · Recalls · Investigations

More warning signs than most Titan years

Owner complaints for the 2006 Nissan Titan are substantially higher than the model-year median of 46.

About this comparison →

When problems were reported

Mileage at the reported incident

376 reports with mileage · 54 unknown

NHTSA’s mileage field refers to the reported incident, not necessarily the filing date. This shows report counts, not the likelihood of a failure.

What to inspect

Issues worth paying extra attention to based on owner reports.

  • Power Train. Review the 194 owner reports in this category and discuss these concerns during a pre-purchase inspection. Read reports →
  • Electrical System. Review the 46 owner reports in this category and discuss these concerns during a pre-purchase inspection. Read reports →
  • Suspension. Review the 45 owner reports in this category and discuss these concerns during a pre-purchase inspection. Read reports →

NHTSA owner reports · September 18, 2026 snapshot.

14 crash reports10 fire reports7 injury reports

Power Train complaints

194 reports
Clear category filter
46,400 miles · Oct 31, 2011
Power Train

I JUST WENT INTO THE DEALERSHIP LAST THURSDAY THE 27TH OF SEPTEMBER TO HAVE A ROUTINE OIL CHANGE PERFORMED. AS PART OF THE INSPECTION THE TECHNICIAN NOTICED THAT MY REAR AXLE SEALS ON MY TRUCK WERE SEEPING/LEAKING AGAIN. THE DEALER HAD REPLACED THE REAR AXLES AND SEALS UNDER POWERTRAIN WARRANTY AT 46520 MILES ON THE ODOMETER. TH…

Read full complaint

I JUST WENT INTO THE DEALERSHIP LAST THURSDAY THE 27TH OF SEPTEMBER TO HAVE A ROUTINE OIL CHANGE PERFORMED. AS PART OF THE INSPECTION THE TECHNICIAN NOTICED THAT MY REAR AXLE SEALS ON MY TRUCK WERE SEEPING/LEAKING AGAIN. THE DEALER HAD REPLACED THE REAR AXLES AND SEALS UNDER POWERTRAIN WARRANTY AT 46520 MILES ON THE ODOMETER. THE TRUCK NOW HAS A LITTLE OVER 54K MILES AND THEY ARE GOING OUT AGAIN. SO ESSENTIALLY 14 MONTHS AFTER THE DEALER REPLACED EVERYTHING IT IS OUT AGAIN. I AM GOING TO CONTACT NISSAN DIRECTLY AGAIN TO GET THIS REPAIRED EVEN THOUGH I AM OUT OF WARRANTY BY LESS THAN A MONTH. THIS IS A SERIOUS SAFETY CONCERN FOR BOTH MY FAMILY AND OTHER DRIVERS ON THE ROAD AS THESE SEALS CAN LEAK OIL ONTO THE BRAKES AND COULD CAUSE A REAR END FAILURE AT DRIVING SPEED WHICH COULD ENDANGER LIVES. THIS TRUCK HAS LOW MILES FOR A 2006 AND TOWS A LIGHT TRAILER WITH ATVS A FEW TIMES A YEAR. ALL MANUFACTURE MAINTENANCE IS PERFORMED ON TIME BY A CERTIFIED MECHANIC. *TR

NHTSA ODI #10433665

92,000 miles · Sep 23, 2011
Power Train

AXLE SEALS ON REAR OF VEHICLE LEAK EXCESSIVELY. *TR

NHTSA ODI #10426969

137,321 miles · Sep 14, 2011
Power Train

REAR AXLE SEALS HAVE NOW FAILED FOR THE 3RD TIME. NISSAN DEALERS TELLS ME NISSAN WILL NOT PERMIT THEM TO REPLACE SEALS ALONE. NISSAN CORPORATE HEADQUARTERS FIX IS TO REPLACE ENTIRE AXLE ASSEMBLY AT A COST OF APPROXIMATELY $800 EACH AXLE. NISSAN IS OBVIOUSLY AWARE OF A DESIGN PROBLEM, BUT WILL NOT TAKE THE LEAD TO FIX, BUT PUT…

Read full complaint

REAR AXLE SEALS HAVE NOW FAILED FOR THE 3RD TIME. NISSAN DEALERS TELLS ME NISSAN WILL NOT PERMIT THEM TO REPLACE SEALS ALONE. NISSAN CORPORATE HEADQUARTERS FIX IS TO REPLACE ENTIRE AXLE ASSEMBLY AT A COST OF APPROXIMATELY $800 EACH AXLE. NISSAN IS OBVIOUSLY AWARE OF A DESIGN PROBLEM, BUT WILL NOT TAKE THE LEAD TO FIX, BUT PUT THE COST OF A DEFECTIVE DESIGN ON THE BACK OF THEIR CUSTOMERS. NISSAN SERVICE REPRESENTATIVE TOLD ME THERE IS A FLAW IN THE MATERIALS USED IN THE DIFFERENTIAL AND DIFFERENTIAL IS NOT VENTING PROPERLY THUS CAUSING THE SEALS TO PREMATURELY FAIL. I FAIL TO UNDERSTAND WHY A RECALL HAS NOT BEEN ISSUED SINCE THIS IS A COMMON PROBLEM ON NISSAN TITAN TRUCKS THAT NISSAN WILL NOT FACE. SOUNDS LIKE NISSAN IS HAVING A TOYOTA MOMENT AND BURYING THEIR HEAD IN THE SAND. *KB

NHTSA ODI #10425463

37,178 miles · Aug 24, 2011
Power Train

REAR AXLE SEAL FAILURE BOTH SIDES. CONTAMINATED BRAKES CAUSING FAILURE OF REAR BRAKES. REPLACEMENT OF SEALS AND BRAKE COMPONENTS NECESSARY FOR REPAIR. ACCIDENT AVOIDED. *TR

NHTSA ODI #10421363

47,887 miles · Aug 16, 2011
Power Train

DRIVER SIDE REAR AXLE SEAL LEAKING OIL AND FAULTY AXLE BEARING AT 50K MILES. VERY COMMON FAILURE IN EARLY MILEAGE LIFE OF VEHICLE, MANY OWNER COMPLAINTS. REPLACE SEAL AN BEARING AT COST OVER $700. THE DRIVER SIDE REAR AXLE FAILURE IS MOST COMMON AND IS NOT THE DOMINANT DRIVE WHEEL. NOW THE PASSENGER SIDE AXLE SHOWING SIGNS OF LE…

Read full complaint

DRIVER SIDE REAR AXLE SEAL LEAKING OIL AND FAULTY AXLE BEARING AT 50K MILES. VERY COMMON FAILURE IN EARLY MILEAGE LIFE OF VEHICLE, MANY OWNER COMPLAINTS. REPLACE SEAL AN BEARING AT COST OVER $700. THE DRIVER SIDE REAR AXLE FAILURE IS MOST COMMON AND IS NOT THE DOMINANT DRIVE WHEEL. NOW THE PASSENGER SIDE AXLE SHOWING SIGNS OF LEAKAGE. VEHICLE DOES NOT TOW ANYTHING AND DOES NOT CARRY HEAVY LOADS. DEALER ADVISED NOT TO DRIVE IT ANY FURTHER OR CATASTROPHIC DAMAGE MAY OCCUR TO REAR DIFFERENTIAL ASSEMBLY ESPECIALLY AT HIGHWAY SPEEDS. REPAIRS HAVE BEEN DONE.

NHTSA ODI #10420369

45,972 miles · Aug 14, 2011
Power Train

DRIVER SIDE REAR AXLE SEAL LEAKING OIL AND FAULTY AXLE BEARING AT 50K MILES. VERY COMMON FAILURE IN EARLY LIFE OF VEHICLE, MANY COMPLAINTS. REPLACE SEAL AN BEARING AT COST OVER $700. THE DRIVER SIDE REAR AXLE FAILURE IS MOST COMMON AND IS NOT THE DOMINANT DRIVE WHEEL. *TR

NHTSA ODI #10419387

88,000 miles · Aug 13, 2011
Power Train

2006 NISSAN TITAN SE REAR LEFT SEAL LEAKING FIXED UNDER WARRANTY. NOW THE SAME ISSUE ON THE LEFT REAR SEAL IS LEAKING AGAIN AND ALSO THE RIGHT REAR SEAL IS STARTING TO LEAK. BASED ON ALL MY RESEARCH I HAVE DONE THIS SEEMS TO BE AN ONGOING ISSUE AND SHOULD BE CONTINUED TO BE COVERED AFTER THE WARRANTY HAS EXPIRED. WHAT ARE MY O…

Read full complaint

2006 NISSAN TITAN SE REAR LEFT SEAL LEAKING FIXED UNDER WARRANTY. NOW THE SAME ISSUE ON THE LEFT REAR SEAL IS LEAKING AGAIN AND ALSO THE RIGHT REAR SEAL IS STARTING TO LEAK. BASED ON ALL MY RESEARCH I HAVE DONE THIS SEEMS TO BE AN ONGOING ISSUE AND SHOULD BE CONTINUED TO BE COVERED AFTER THE WARRANTY HAS EXPIRED. WHAT ARE MY OPTIONS. MY TRUCK IS NOW AT THE DEALER AND I SHOULD NOT HAVE TO PAY FOR REPAIRS. MY TRUCK HAS ONLY 88,000 MILES. *TR

NHTSA ODI #10419298

Mileage unknown · Aug 5, 2011
Power Train

THE REAR ALE BEARINGS IN MY 2006 4X4 NISSAN TITAN HAVE FAILED. NO PARTS MANUFACTURER EXCEPT NISSAN IS OFFERING THE PARTS AND ONLY AS A WHOLE DIFFERENTIAL UNIT. *TT

NHTSA ODI #10417658

57,886 miles · Aug 3, 2011
Power Train

THE FRONT DIFFERENTIAL CARRIER BEARING HAS FAILED CAUSING SEVERE BACKLASH IN THE DRIVES SHAFT AND A FAILURE OF THE PINION. ALSO THE FRONT LEFT SEAL HAS FAILED CAUSING A LEAK TO PROGRESSIVELY GET BIGGER ALLOWING MORE AND MORE LUBRICANT TO ESCAPE.

NHTSA ODI #10417480

85,000 miles · Jul 21, 2011
Power Train

POWER TRAIN:AXLE ASSEMBLY:AXLE SHAFT:SEAL 2006 NISSAN TITAN *KB

NHTSA ODI #10413872

Official recalls

5

10V517000 · Engine And Engine Cooling

Oct 28, 2010

NISSAN IS RECALLING CERTAIN MODEL YEAR 2004-2006 ARMADA, TITAN, INFINITI QX56 AND MODEL YEAR 2005-2006 FRONTIER, PATHFINDER AND XTERRA VEHICLES. THE INTELLIGENT POWER DISTRIBUTION MODULE (IPDM) ASSEMBLY CONTAINS AN ENGINE CONTROL MODULE (ECM) RELAY THAT HAS A DIODE FOR ELECTRICAL CURRENT NOISE REDUCTION. THE ECM RELAY MAY ALLOW SILICON VAPOR TO FORM AND, OVER TIME, THE SILICON EVAPORATES FROM THE DIODE MOLDING WHICH CAUSES SILICON OXIDE TO DEVELOP ON THE ECM RELAY CONTACT DUE TO ARCING.

Consequence & remedy

Consequence: THIS COULD CAUSE ENGINE STALLING INCREASING THE RISK OF A CRASH.

Remedy: DEALERS WILL REPLACE THE ECM RELAY INSIDE THE IPDM ASSEMBLY. THIS SERVICE WILL BE PERFORMED FREE OF CHARGE. THE SAFETY RECALL BEGAN ON DECEMBER 6, 2010. OWNERS MAY CONTACT NISSAN AT 1-800-647-7261.

10V074000 · Fuel System, Other:storage:fuel Gauge System

Mar 3, 2010

NISSAN IS RECALLING CERTAIN MODEL YEAR 2005-2009 TITAN, ARMADA, AND INFINITI QX56 VEHICLES. THE INSTRUMENT PANEL FUEL GAUGE MAY INACCURATELY DISPLAY THAT THE VEHICLE STILL HAS SOME FUEL, TYPICALLY ABOUT ONE QUARTER TANK, WHEN THE FUEL TANK IS EMPTY.

Consequence & remedy

Consequence: THIS COULD CAUSE THE VEHICLE TO RUN OUT OF GAS AND STALL ON THE HIGHWAY, WHICH COULD CAUSE A CRASH.

Remedy: DEALERS WILL REPLACE THE FUEL SENDER UNIT INSIDE THE FUEL TANK WITH A NEW IMPROVED SENDER CARD. THIS SERVICE WILL BE PERFORMED FREE OF CHARGE. THE SAFETY RECALL BEGAN ON MARCH 22, 2010. OWNERS MAY CONTACT NISSAN AT 1-800-647-7261.

08V284000 · Equipment:appliance:air Conditioner

Jun 27, 2008

NISSAN IS RECALLING 180,664 MY 2005-2006 TITAN, ARMADA AND INFINITY QX56 VEHICLES MANUFACTURED AFTER MARCH 17, 2005, THAT ARE EQUIPPED WITH A VISTEON AIR CONDITIONING CONDENSER FAN MOTOR. THE FAN MOTOR MAY NOT BE PROPERLY SEALED ALLOWING EXCESSIVE WATER INTRUSION AND INADEQUATE DRAINAGE OF MOISTURE.

Consequence & remedy

Consequence: THIS COULD CAUSE CORROSION IN THE MOTOR LEADING POSSIBLY TO OVERHEATING AND A FIRE.

Remedy: DEALERS WILL INSTALL A 'THERMAL PROTECTOR KIT' AND TEST THE AIR CONDITIONING CONDENSER FAN MOTOR AND REPLACE IT IF NECESSARY. THE RECALL BEGAN ON AUGUST 2, 2008. OWNERS MAY CONTACT NISSAN AT 1-800-647-7261.

06V459000 · Electrical System

Nov 30, 2006

ON CERTAIN KING CAB TRUCKS, THE WIRES IN THE HARNESS WERE ROUTED THROUGH THE REAR DOORS AND INTO THE BODY. THESE WIRES MAY BREAK DUE TO OVER BENDING OF THE HARNESS AS THE DOOR IS OPENED AND CLOSED. THE HARNESS CONTAINS WIRES FOR THE DRIVER SEAT BELT PRETENSIONER AND FOR THE FRONT PASSENGER SEAT BELT WHICH IS PART OF THE OCCUPANT CLASSIFICATION SYSTEM. WIRES FOR THE REAR AUDIO SPEAKERS ARE ALSO CONTAINED N THE HARNESS.

Consequence & remedy

Consequence: IF THE WIRES FOR THE SEAT BELTS AND SPEAKER WIRES BREAK AND MAKE CONTACT, THERE IS A POSSIBILITY THAT THE PRETENSIONER MAY DEPLOY. IF THIS HAPPENS WHEN THE SEAT BELT IS RETRACTED, IT WILL NOT BE POSSIBLE TO USE THE SEAT BELT. IF ONE OF THE WIRES ON THE RIGHT SIDE HARNESS FOR THE SEAT BELT TENSION SENSOR BREAKS, THE PASSENGER SIDE FRONT AIR BAG WILL NOT DEPLOY AS DESIGNED IN A FRONTAL COLLISION INCREASING THE RISK OF A CRASH AND PERSONAL INJURY.

Remedy: DEALERS WILL REPLACE THE WIRE HARNESS COVER WITH A DIFFERENT TYPE THAT PREVENTS OVER BENDING OF THE HARNESS AND THE HARNESS WILL BE REROUTED FREE OF CHARGE. THE RECALL BEGAN ON FEBRUARY 19, 2007. OWNERS MAY CONTACT NISSAN AT 1-800-647-7261.

06V064000 · Latches/locks/linkages:doors:latch

Mar 8, 2006

CERTAIN LIGHT TRUCKS FAIL TO COMPLY WITH THE REQUIREMENTS OF FEDERAL MOTOR VEHICLE SAFETY STANDARD NO. 206, "DOOR LOCKS AND DOOR RETENTION COMPONENTS." AN ARC WELD IS MISSING ON SOME RIGHT SIDE REAR DOOR UPPER LATCH ASSEMBLIES.

Consequence & remedy

Consequence: THIS MAY RESULT IN THE RIGHT SIDE DOORS COMING PARTIALLY OPEN INCREASING THE RISK OF INJURY TO OCCUPANTS.

Remedy: DEALERS WILL REPLACE THE UPPER LATCH ASSEMBLY FREE OF CHARGE. THE RECALL BEGAN ON APRIL 3, 2006. OWNERS MAY CONTACT NISSAN AT 800-662-6200.

Model-level recall history does not show whether a particular VIN is affected or has received a repair. Check a VIN with NHTSA ↗

NHTSA investigations

1

PE08037 · Engine Compartment Fire

Opened May 30, 2008 · Closed Aug 25, 2008

Status: closed (inferred from source dates) · Electrical System:wiring; Electrical System:wiring:front Underhood; Engine And Engine Cooling; Engine And Engine Cooling:engine

ON MAY 30, 2008, THE OFFICE OF DEFECTS INVESTIGATION (ODI) OPENED A PRELIMINARY EVALUATION BASED ON CONSUMER COMPLAINTS ALLEGING THAT SMOKE AND/OR FIRE ERUPTED IN THE ENGINE COMPARTMENT OF MODEL YEAR (MY) 2005-2006 NISSAN ARMADA AND TITAN VEHICLES.BY LETTER DATED JUNE 24, 2008, NISSAN NOTIFIED THE NATIONAL HIGHWAY TRAFFIC SAFETY ADMINISTRATION (NHTSA) THAT IT WILL CONDUCT A SAFETY RECALL (NHTSA #08V284) FOR MY2005-2006 NISSAN TITAN, ARMADA AND INFINITI QX56 VEHICLES MANUFACTURED FROM MARCH 17, 2005 TO AUGUST 21, 2006 THAT ARE EQUIPPED WITH A 90-WATT AIR CONDITIONING CONDENSER FAN.THE RECALL INVOLVES APPROXIMATELY 180,664 VEHICLES.THIS ALSO INCLUDES APPROXIMATELY 5,689 SUBJECT CONDENSER FANS, SOME OF WHICH MAY HAVE BEEN INSTALLED IN MY2004 AND PRE-MARCH 17, 2005 MY NISSAN TITAN, ARMADA OR INFINITI QX56 VEHICLES AS A SERVICE REPLACEMENT PART.NISSAN DEALERS WILL INSTALL A SPECIAL THERMAL PROTECTOR KIT ON EXISTING FANS THAT WILL ELIMINATE THE POTENTIAL FOR A FIRE TO OCCUR.NISSAN NORTH AMERICA, INC. (NISSAN) INFORMED ODI THAT THE 90-WATT AIR CONDITIONING CONDENSER FAN WAS MANUFACTURED OUT-OF-SPECIFICATION ALLOWING FOR EXCESSIVE WATER INTRUSION AND INADEQUATE DRAINAGE OF MOISTURE THAT MAY ACCUMULATE IN THE MOTOR AS A RESULT OF WATER INTRUSION OR CONDENSATION.IF SUFFICIENT MOISTURE ACCUMULATES IN THE MOTOR WITHOUT ADEQUATE DRAINAGE, CORROSION MAY OCCUR.THE CORROSION CAN CAUSE AN INCREASE IN INTERNAL FRICTION AND AN INCREASE IN THE ELECTRICAL CURRENT DRAW, RESULTING IN AN INCREASE IN THE TEMPERATURE OF THE MOTOR THAT COULD MELT ITS WIRING INSULATION AND OTHER PLASTIC COMPONENTS AND FORM A GAS.IF TWO WIRES WITHOUT INSULATION TOUCH EACH OTHER AND CREATE A SPARK, THIS GAS COULD IGNITE AND RESULT IN A FIRE.THE ACTION TAKEN BY NISSAN IS SUFFICIENT TO RESOLVE THE ISSUE RAISED BY THIS INVESTIGATION.ACCORDINGLY, THIS INVESTIGATION IS CLOSED.

Additional source detail variants (4)

Electrical System:wiring:front Underhood

ON MAY 30, 2008, THE OFFICE OF DEFECTS INVESTIGATION (ODI) OPENED A PRELIMINARY EVALUATION BASED ON CONSUMER COMPLAINTS ALLEGING THAT SMOKE AND/OR FIRE ERUPTED IN THE ENGINE COMPARTMENT OF MODEL YEAR (MY) 2005-2006 NISSAN ARMADA AND TITAN VEHICLES.BY LETTER DATED JUNE 24, 2008, NISSAN NOTIFIED THE NATIONAL HIGHWAY TRAFFIC SAFETY ADMINISTRATION (NHTSA) THAT IT WILL CONDUCT A SAFETY RECALL (NHTSA #08V284) FOR MY2005-2006 NISSAN TITAN, ARMADA AND INFINITI QX56 VEHICLES MANUFACTURED FROM MARCH 17, 2005 TO AUGUST 21, 2006 THAT ARE EQUIPPED WITH A 90-WATT AIR CONDITIONING CONDENSER FAN.THE RECALL INVOLVES APPROXIMATELY 180,664 VEHICLES.THIS ALSO INCLUDES APPROXIMATELY 5,689 SUBJECT CONDENSER FANS, SOME OF WHICH MAY HAVE BEEN INSTALLED IN MY2004 AND PRE-MARCH 17, 2005 MY NISSAN TITAN, ARMADA OR INFINITI QX56 VEHICLES AS A SERVICE REPLACEMENT PART.NISSAN DEALERS WILL INSTALL A SPECIAL THERMAL PROTECTOR KIT ON EXISTING FANS THAT WILL ELIMINATE THE POTENTIAL FOR A FIRE TO OCCUR.NISSAN NORTH AMERICA, INC. (NISSAN) INFORMED ODI THAT THE 90-WATT AIR CONDITIONING CONDENSER FAN WAS MANUFACTURED OUT-OF-SPECIFICATION ALLOWING FOR EXCESSIVE WATER INTRUSION AND INADEQUATE DRAINAGE OF MOISTURE THAT MAY ACCUMULATE IN THE MOTOR AS A RESULT OF WATER INTRUSION OR CONDENSATION.IF SUFFICIENT MOISTURE ACCUMULATES IN THE MOTOR WITHOUT ADEQUATE DRAINAGE, CORROSION MAY OCCUR.THE CORROSION CAN CAUSE AN INCREASE IN INTERNAL FRICTION AND AN INCREASE IN THE ELECTRICAL CURRENT DRAW, RESULTING IN AN INCREASE IN THE TEMPERATURE OF THE MOTOR THAT COULD MELT ITS WIRING INSULATION AND OTHER PLASTIC COMPONENTS AND FORM A GAS.IF TWO WIRES WITHOUT INSULATION TOUCH EACH OTHER AND CREATE A SPARK, THIS GAS COULD IGNITE AND RESULT IN A FIRE.THE ACTION TAKEN BY NISSAN IS SUFFICIENT TO RESOLVE THE ISSUE RAISED BY THIS INVESTIGATION.ACCORDINGLY, THIS INVESTIGATION IS CLOSED.

Electrical System:wiring

ON MAY 30, 2008, THE OFFICE OF DEFECTS INVESTIGATION (ODI) OPENED A PRELIMINARY EVALUATION BASED ON CONSUMER COMPLAINTS ALLEGING THAT SMOKE AND/OR FIRE ERUPTED IN THE ENGINE COMPARTMENT OF MODEL YEAR (MY) 2005-2006 NISSAN ARMADA AND TITAN VEHICLES.BY LETTER DATED JUNE 24, 2008, NISSAN NOTIFIED THE NATIONAL HIGHWAY TRAFFIC SAFETY ADMINISTRATION (NHTSA) THAT IT WILL CONDUCT A SAFETY RECALL (NHTSA #08V284) FOR MY2005-2006 NISSAN TITAN, ARMADA AND INFINITI QX56 VEHICLES MANUFACTURED FROM MARCH 17, 2005 TO AUGUST 21, 2006 THAT ARE EQUIPPED WITH A 90-WATT AIR CONDITIONING CONDENSER FAN.THE RECALL INVOLVES APPROXIMATELY 180,664 VEHICLES.THIS ALSO INCLUDES APPROXIMATELY 5,689 SUBJECT CONDENSER FANS, SOME OF WHICH MAY HAVE BEEN INSTALLED IN MY2004 AND PRE-MARCH 17, 2005 MY NISSAN TITAN, ARMADA OR INFINITI QX56 VEHICLES AS A SERVICE REPLACEMENT PART.NISSAN DEALERS WILL INSTALL A SPECIAL THERMAL PROTECTOR KIT ON EXISTING FANS THAT WILL ELIMINATE THE POTENTIAL FOR A FIRE TO OCCUR.NISSAN NORTH AMERICA, INC. (NISSAN) INFORMED ODI THAT THE 90-WATT AIR CONDITIONING CONDENSER FAN WAS MANUFACTURED OUT-OF-SPECIFICATION ALLOWING FOR EXCESSIVE WATER INTRUSION AND INADEQUATE DRAINAGE OF MOISTURE THAT MAY ACCUMULATE IN THE MOTOR AS A RESULT OF WATER INTRUSION OR CONDENSATION.IF SUFFICIENT MOISTURE ACCUMULATES IN THE MOTOR WITHOUT ADEQUATE DRAINAGE, CORROSION MAY OCCUR.THE CORROSION CAN CAUSE AN INCREASE IN INTERNAL FRICTION AND AN INCREASE IN THE ELECTRICAL CURRENT DRAW, RESULTING IN AN INCREASE IN THE TEMPERATURE OF THE MOTOR THAT COULD MELT ITS WIRING INSULATION AND OTHER PLASTIC COMPONENTS AND FORM A GAS.IF TWO WIRES WITHOUT INSULATION TOUCH EACH OTHER AND CREATE A SPARK, THIS GAS COULD IGNITE AND RESULT IN A FIRE.THE ACTION TAKEN BY NISSAN IS SUFFICIENT TO RESOLVE THE ISSUE RAISED BY THIS INVESTIGATION.ACCORDINGLY, THIS INVESTIGATION IS CLOSED.

Engine And Engine Cooling:engine

ON MAY 30, 2008, THE OFFICE OF DEFECTS INVESTIGATION (ODI) OPENED A PRELIMINARY EVALUATION BASED ON CONSUMER COMPLAINTS ALLEGING THAT SMOKE AND/OR FIRE ERUPTED IN THE ENGINE COMPARTMENT OF MODEL YEAR (MY) 2005-2006 NISSAN ARMADA AND TITAN VEHICLES.BY LETTER DATED JUNE 24, 2008, NISSAN NOTIFIED THE NATIONAL HIGHWAY TRAFFIC SAFETY ADMINISTRATION (NHTSA) THAT IT WILL CONDUCT A SAFETY RECALL (NHTSA #08V284) FOR MY2005-2006 NISSAN TITAN, ARMADA AND INFINITI QX56 VEHICLES MANUFACTURED FROM MARCH 17, 2005 TO AUGUST 21, 2006 THAT ARE EQUIPPED WITH A 90-WATT AIR CONDITIONING CONDENSER FAN.THE RECALL INVOLVES APPROXIMATELY 180,664 VEHICLES.THIS ALSO INCLUDES APPROXIMATELY 5,689 SUBJECT CONDENSER FANS, SOME OF WHICH MAY HAVE BEEN INSTALLED IN MY2004 AND PRE-MARCH 17, 2005 MY NISSAN TITAN, ARMADA OR INFINITI QX56 VEHICLES AS A SERVICE REPLACEMENT PART.NISSAN DEALERS WILL INSTALL A SPECIAL THERMAL PROTECTOR KIT ON EXISTING FANS THAT WILL ELIMINATE THE POTENTIAL FOR A FIRE TO OCCUR.NISSAN NORTH AMERICA, INC. (NISSAN) INFORMED ODI THAT THE 90-WATT AIR CONDITIONING CONDENSER FAN WAS MANUFACTURED OUT-OF-SPECIFICATION ALLOWING FOR EXCESSIVE WATER INTRUSION AND INADEQUATE DRAINAGE OF MOISTURE THAT MAY ACCUMULATE IN THE MOTOR AS A RESULT OF WATER INTRUSION OR CONDENSATION.IF SUFFICIENT MOISTURE ACCUMULATES IN THE MOTOR WITHOUT ADEQUATE DRAINAGE, CORROSION MAY OCCUR.THE CORROSION CAN CAUSE AN INCREASE IN INTERNAL FRICTION AND AN INCREASE IN THE ELECTRICAL CURRENT DRAW, RESULTING IN AN INCREASE IN THE TEMPERATURE OF THE MOTOR THAT COULD MELT ITS WIRING INSULATION AND OTHER PLASTIC COMPONENTS AND FORM A GAS.IF TWO WIRES WITHOUT INSULATION TOUCH EACH OTHER AND CREATE A SPARK, THIS GAS COULD IGNITE AND RESULT IN A FIRE.THE ACTION TAKEN BY NISSAN IS SUFFICIENT TO RESOLVE THE ISSUE RAISED BY THIS INVESTIGATION.ACCORDINGLY, THIS INVESTIGATION IS CLOSED.

Engine And Engine Cooling

ON MAY 30, 2008, THE OFFICE OF DEFECTS INVESTIGATION (ODI) OPENED A PRELIMINARY EVALUATION BASED ON CONSUMER COMPLAINTS ALLEGING THAT SMOKE AND/OR FIRE ERUPTED IN THE ENGINE COMPARTMENT OF MODEL YEAR (MY) 2005-2006 NISSAN ARMADA AND TITAN VEHICLES.BY LETTER DATED JUNE 24, 2008, NISSAN NOTIFIED THE NATIONAL HIGHWAY TRAFFIC SAFETY ADMINISTRATION (NHTSA) THAT IT WILL CONDUCT A SAFETY RECALL (NHTSA #08V284) FOR MY2005-2006 NISSAN TITAN, ARMADA AND INFINITI QX56 VEHICLES MANUFACTURED FROM MARCH 17, 2005 TO AUGUST 21, 2006 THAT ARE EQUIPPED WITH A 90-WATT AIR CONDITIONING CONDENSER FAN.THE RECALL INVOLVES APPROXIMATELY 180,664 VEHICLES.THIS ALSO INCLUDES APPROXIMATELY 5,689 SUBJECT CONDENSER FANS, SOME OF WHICH MAY HAVE BEEN INSTALLED IN MY2004 AND PRE-MARCH 17, 2005 MY NISSAN TITAN, ARMADA OR INFINITI QX56 VEHICLES AS A SERVICE REPLACEMENT PART.NISSAN DEALERS WILL INSTALL A SPECIAL THERMAL PROTECTOR KIT ON EXISTING FANS THAT WILL ELIMINATE THE POTENTIAL FOR A FIRE TO OCCUR.NISSAN NORTH AMERICA, INC. (NISSAN) INFORMED ODI THAT THE 90-WATT AIR CONDITIONING CONDENSER FAN WAS MANUFACTURED OUT-OF-SPECIFICATION ALLOWING FOR EXCESSIVE WATER INTRUSION AND INADEQUATE DRAINAGE OF MOISTURE THAT MAY ACCUMULATE IN THE MOTOR AS A RESULT OF WATER INTRUSION OR CONDENSATION.IF SUFFICIENT MOISTURE ACCUMULATES IN THE MOTOR WITHOUT ADEQUATE DRAINAGE, CORROSION MAY OCCUR.THE CORROSION CAN CAUSE AN INCREASE IN INTERNAL FRICTION AND AN INCREASE IN THE ELECTRICAL CURRENT DRAW, RESULTING IN AN INCREASE IN THE TEMPERATURE OF THE MOTOR THAT COULD MELT ITS WIRING INSULATION AND OTHER PLASTIC COMPONENTS AND FORM A GAS.IF TWO WIRES WITHOUT INSULATION TOUCH EACH OTHER AND CREATE A SPARK, THIS GAS COULD IGNITE AND RESULT IN A FIRE.THE ACTION TAKEN BY NISSAN IS SUFFICIENT TO RESOLVE THE ISSUE RAISED BY THIS INVESTIGATION.ACCORDINGLY, THIS INVESTIGATION IS CLOSED.