← New search

2005 Nissan Titan

Owner reports · Recalls · Investigations

More warning signs than most Titan years

Owner complaints for the 2005 Nissan Titan are substantially higher than the model-year median of 46.

About this comparison →

When problems were reported

Mileage at the reported incident

800 reports with mileage · 91 unknown

NHTSA’s mileage field refers to the reported incident, not necessarily the filing date. This shows report counts, not the likelihood of a failure.

What to inspect

Issues worth paying extra attention to based on owner reports.

  • Power Train. Review the 469 owner reports in this category and discuss these concerns during a pre-purchase inspection. Read reports →
  • Fuel/propulsion System. Review the 68 owner reports in this category and discuss these concerns during a pre-purchase inspection. Read reports →
  • Suspension. Review the 65 owner reports in this category and discuss these concerns during a pre-purchase inspection. Read reports →

NHTSA owner reports · September 18, 2026 snapshot.

11 crash reports7 fire reports10 injury reports

What owners actually said

891 reports
120,000 miles · Jul 31, 2015
Fuel/propulsion System

DRIVING TO WORK IN THE MORNING RUSH HOUR TRAFFIC, AT APPROX 65 MPH, I EXPERIENCED MY 2005 NISSAN TITAN SHUT COMPLETELY DOWN LOSING ALL POWER TO THE ENGINE RESULTING IN A LOSS OF POWER TO ALL SUPPORTING ENGINE ACCESSORIES INCLUDING THE POWER STEERING AND ABS. I ATTEMPTED TO RESTART THE VEHICLE WHILE DRIVING, BY DOWN SHIFTING TO N…

Read full complaint

DRIVING TO WORK IN THE MORNING RUSH HOUR TRAFFIC, AT APPROX 65 MPH, I EXPERIENCED MY 2005 NISSAN TITAN SHUT COMPLETELY DOWN LOSING ALL POWER TO THE ENGINE RESULTING IN A LOSS OF POWER TO ALL SUPPORTING ENGINE ACCESSORIES INCLUDING THE POWER STEERING AND ABS. I ATTEMPTED TO RESTART THE VEHICLE WHILE DRIVING, BY DOWN SHIFTING TO NEUTRAL, WHICH FAILED. FORTUNATELY I WAS ABLE TO FIND A FIND A SPOT TO PULL OVER ON THE SIDE OF THE BUSY HIGHWAY AND CALL FOR ROADSIDE ASSISTANCE. IT WAS LATER DETERMINED THAT I HAD RUN OUT OF FUEL, DESPITE THE FUEL GAUGE SHOWING WELL OVER 1/4 OF A TANK OF USABLE FUEL. AT THIS POINT I DISCOVERED A RECALL CAMPAIGN FOR THE 2005 - 2009 NISSAN TITAN INSTRUMENT PANEL FUEL GAUGE (NHTSA CAMPAIGN NUMBER: 10V074000) AND PROCEEDED TO CALL THE PHONE NUMBER LISTED IN THE REMEDY PORTION OF THE RECALL. WHEN SPEAKING WITH NISSAN IT WAS DETERMINED THAT MY VIN WASN'T INCLUDED IN THE RECALL CAMPAIGN, AND AN APPOINTMENT WAS MADE AT THE LOCAL NISSAN DEALERSHIP BY NISSAN CONSUMER AFFAIRS TO CONFIRM MY FINDING AND SEE IF THEY WOULD BE ABLE TO COMPLETE THE REPAIR FOR ME UNDER THE RECALL. WHEN I BROUGHT MY VEHICLE TO MY LOCAL NISSAN DEALERSHIP THEY INFORMED ME THAT THE VEHICLE VIN WASN'T APART OF THE RECALL, BUT DID SEE A SERVICE BULLETIN ASSOCIATED WITH THAT MAKE AND MODEL. IT WAS ULTIMATELY DETERMINED THEY WOULDN'T BE ABLE TO RECOVER WARRANTY MONEY FROM NISSAN, AND INFORMED ME THAT I WOULD NEED TO PAY FOR THE REPAIR OUT OF POCKET. BOTTOM LINE, IT CAME DOWN TO A MONETARY ISSUE NOT A SAFETY FACTOR ISSUE FOR NISSAN. IT WAS OBVIOUS MY VEHICLE EXPERIENCED THE SAME POTENTIAL CONSEQUENCES AS THE OTHER 2005 NISSAN TITAN VIN'S IN THE RECALL CAMPAIGN. HOWEVER, BASED ON MY EXPERIENCE IN TRYING TO RESOLVE THIS MATTER, IT IS OBVIOUS NISSAN FEELS THE ONUS OF LIABILITY ULTIMATELY FALLS ON ME AS A CONSUMER AND NOT THEM, IF I WOULD LIKE TO OPERATE MY VEHICLE IN A SAFE MANNER. UPDATED 10/9/15 *LN UPDATED 12/21/2015 *JS

NHTSA ODI #10745239

84,601 miles · Jun 15, 2015
Service BrakesSteeringVehicle Speed ControlCrash

THE TRUCK STALLED OUT NO POWER HAD TO CRASH INTO SHOULDER OF ROAD AND EMBANKMENT. GLAD WE SURVIVED THE BUMPY CRASH, I JUST HAD SUSPENSION WORK DONE THAT SAVED US. WE READ THE IPDM BOARD OR ECM RELAY IS BAD AND CAUSES THIS STALLING TO HAPPEN. PART NUMBER FOR ECM RELAY 284B7-CW29.

NHTSA ODI #10725446

172,023 miles · May 16, 2015
Power Train

REAR DIFFERENTIAL FAILED. REAR SEAL AND E LOCKER FAILED

NHTSA ODI #10716879

Mileage unknown · May 10, 2015
EngineFuel/propulsion SystemSuspension

HI, I HAVE A 2005 NISSAN TITAN AND THE EXHAUST MANIFOLD HAS CRACKED IN THE SAME SPOT TWICE NOW AND IT IS BEFORE THE CAT SO THAT MEANS ITS NOW A GROSS POLLUTER. THE PROBLEM IS YOU GET IT FIXED AND THEY PUT THE SAME PART BACK ON THAT CRACKS AGAIN BECAUSE THEY HAVEN'T CHANGED THE DESIGN. THERE ARE 3 OTHER TITANS IN MY TOWN AND A…

Read full complaint

HI, I HAVE A 2005 NISSAN TITAN AND THE EXHAUST MANIFOLD HAS CRACKED IN THE SAME SPOT TWICE NOW AND IT IS BEFORE THE CAT SO THAT MEANS ITS NOW A GROSS POLLUTER. THE PROBLEM IS YOU GET IT FIXED AND THEY PUT THE SAME PART BACK ON THAT CRACKS AGAIN BECAUSE THEY HAVEN'T CHANGED THE DESIGN. THERE ARE 3 OTHER TITANS IN MY TOWN AND ALL OF US HAVE THE SAME STORY. ALSO THE SWAY BAR MOUNT ON ALL OF OURS ARE BROKE WITCH RESULTS IN VERY POOR HANDLING. I HOPE IT CAN BE RECALLED BEFORE SOMETHING SERIOUS HAPPENS. THANK YOU.

NHTSA ODI #10715537

151,000 miles · May 6, 2015
Power Train

I BACK OUT OF MY DRIVEWAY, STOPPED THE TRUCK COMPLETELY, SHIFTED FROM REVERSE TO DRIVE AND AS SOON AS I TOUCHED THE ACCELERATOR PEDAL I HERD A LOUD POP AND THEN VIOLENT GRINDING. I SHIFTED MY TRUCK TO 4X4 TO PULL IT OFF THE ROAD WHERE IT IS STILL JUST SETTING WAITING TO BE REPAIRED. *TR

NHTSA ODI #10714893

Mileage unknown · May 4, 2015
Fuel/propulsion System

WE TOOK THE TITAN TO A NISSAN DEALERSHIP FOR RECALL SERVICE AND GENERAL SERVICE ONLY TO FIND OUT THAT THE FUEL LEVEL SENSOR THAT WAS ON RECALL NOTICE IS NOT COVERED ON OUR PARTICULAR VIN. INTERESTING THAT THE $110 DIAGNOSTIC TEST I WAS CHARGED FOR SHOWED THAT SENSOR HAS FAILED, BUT NISSAN REFUSES TO COVER MY VEHICLE UNDER THE R…

Read full complaint

WE TOOK THE TITAN TO A NISSAN DEALERSHIP FOR RECALL SERVICE AND GENERAL SERVICE ONLY TO FIND OUT THAT THE FUEL LEVEL SENSOR THAT WAS ON RECALL NOTICE IS NOT COVERED ON OUR PARTICULAR VIN. INTERESTING THAT THE $110 DIAGNOSTIC TEST I WAS CHARGED FOR SHOWED THAT SENSOR HAS FAILED, BUT NISSAN REFUSES TO COVER MY VEHICLE UNDER THE RECALL. BY LOOKING AT THE COMPLAINTS ON THIS SITE, I CAN SEE I AM NOT THE ONLY CONSUMER AFFECTED BY THIS ISSUE. MAKES ME WONDER IF NISSAN IS ACTUALLY HONORING ANY OF THE RECALLS FOR THIS PARTICULAR REPAIR. INTERESTING THAT AFTER MY SERVICE DATE, I WAS CONTACTED BY A SALES REPRESENTATIVE WITH THE SAME DEALERSHIP ASKING IF I WOULD CONSIDER BRINGING IN MY 2005 TITAN FOR A TRADE-IN OPPORTUNITY. I DON'T WANT A NEW CAR, I WANT THIS ONE REPAIRED WITH THE RECALL THAT WAS ISSUED TO ADDRESS THIS PROBLEM. I CONTACTED THE NATIONAL OFFICE AND WAS ASSIGNED A CASE NUMBER AND THE INDIVIDUAL HANDLING THE CASE ALSO DECLINED MY REQUEST FOR REPAIR. ON THAT SAME CALL, I WAS ASKED HOW MANY NISSAN VEHICLES I OWN AND IF I WOULD CONSIDER BUYING A NISSAN IN THE FUTURE. BASED ON MY EXPERIENCE WITH THIS RECALL, I WILL NEVER OWN ANOTHER NISSAN. NOR WILL I RECOMMEND NISSAN TO ANYONE WHO ASKED WHAT OUR EXPERIENCE HAS BEEN WITH THIS VEHICLE AND THE NISSAN MOTOR CORPORATION. *TR

NHTSA ODI #10714405

170,000 miles · Apr 14, 2015
Fuel/propulsion System

TL* THE CONTACT OWNS A 2005 NISSAN TITAN. THE CONTACT STATED THAT THE VEHICLE FAILED TO START. THE VEHICLE WAS INSPECTED BY AN INDEPENDENT MECHANIC. THE TECHNICIAN DIAGNOSED THAT THE FUEL TANK WAS EMPTY AND NEEDED FUEL IN ORDER TO START THE VEHICLE. ALSO, THE TECHNICIAN NOTICED THAT THE FUEL GAUGE READ A QUARTER TANK FULL. AS A…

Read full complaint

TL* THE CONTACT OWNS A 2005 NISSAN TITAN. THE CONTACT STATED THAT THE VEHICLE FAILED TO START. THE VEHICLE WAS INSPECTED BY AN INDEPENDENT MECHANIC. THE TECHNICIAN DIAGNOSED THAT THE FUEL TANK WAS EMPTY AND NEEDED FUEL IN ORDER TO START THE VEHICLE. ALSO, THE TECHNICIAN NOTICED THAT THE FUEL GAUGE READ A QUARTER TANK FULL. AS A RESULT, THE TECHNICIAN DIAGNOSED THAT THE FUEL SENDER UNIT INSIDE THE FUEL TANK NEEDED TO BE REPLACED. THE VEHICLE WAS NOT REPAIRED. THE MANUFACTURER WAS NOTIFIED OF THE FAILURE AND STATED THAT THE VIN WAS NOT INCLUDED IN NHTSA CAMPAIGN NUMBER: 10V074000 (FUEL SYSTEM, OTHER). THE APPROXIMATE FAILURE MILEAGE WAS 170,000.

NHTSA ODI #10705623

149,000 miles · Apr 8, 2015
Power Train

WHEN I PUT VEHICLE IN DRIVE, IT WOULD ONLY GO IN REVERSE. I DISCOVERED THE LINKAGE FROM THE GEARSHIFT LEVER TO THE CABLE HAD SEPARATED. THE PLASTIC RETAINING RING ON THE SHIFT CABLE HAD BROKEN TO PIECES AND LEFT NOTHING TO HOLD THE CABLE TO THE SHIFT LEVER. THIS IS POTENTIALLY EXTREMELY DANGEROUS AS A DRIVER COULD MOVE LEVER …

Read full complaint

WHEN I PUT VEHICLE IN DRIVE, IT WOULD ONLY GO IN REVERSE. I DISCOVERED THE LINKAGE FROM THE GEARSHIFT LEVER TO THE CABLE HAD SEPARATED. THE PLASTIC RETAINING RING ON THE SHIFT CABLE HAD BROKEN TO PIECES AND LEFT NOTHING TO HOLD THE CABLE TO THE SHIFT LEVER. THIS IS POTENTIALLY EXTREMELY DANGEROUS AS A DRIVER COULD MOVE LEVER TO PARK AND THINK HE IS ACTUALLY IN PARK WHEN THE TRANSMISSION IS ENGAGED. SOMEONE GETTING OUT OF THE VEHICLE WHILE IT IS STILL RUNNING WILL THEN HAVE A RUNAWAY VEHICLE. LOCAL NISSAN DEALER HAD NO REPLACEMENT PART. I INSTALLED A RETAINING RING AND CLIP. THE FIX COSTS PENNIES AND JUST A FEW MINUTES TIME. *TR

NHTSA ODI #10704396

155,000 miles · Apr 7, 2015
Electrical SystemFuel/propulsion System

WHILE DRIVING ON A HIGHWAY AT APPROXIMATELY 55 MPH, MY ENGINE STALLED. I LOST ALL ENGINE POWER TO MY TRUCK, WITH NO ERROR CODES, NO CHECK ENGINE LIGHT. I HAD TO PLACE MY TRUCK IN NEUTRAL WHILE AT SPEED IN TRAFFIC IN THE LEFT LANE AND COAST TO A SAFE LOCATION ON THE RIGHT SHOULDER. DURING THIS TIME, I HAD NO POWER STEERING OR …

Read full complaint

WHILE DRIVING ON A HIGHWAY AT APPROXIMATELY 55 MPH, MY ENGINE STALLED. I LOST ALL ENGINE POWER TO MY TRUCK, WITH NO ERROR CODES, NO CHECK ENGINE LIGHT. I HAD TO PLACE MY TRUCK IN NEUTRAL WHILE AT SPEED IN TRAFFIC IN THE LEFT LANE AND COAST TO A SAFE LOCATION ON THE RIGHT SHOULDER. DURING THIS TIME, I HAD NO POWER STEERING OR POWER BRAKES. AFTER I SAFELY STOPPED ON THE SHOULDER, I TRIED TO RESTART MY ENGINE. MY ENGINE WOULD NOT START. APPROXIMATELY ONE MONTH PRIOR TO THIS INCIDENT, MY TRUCK HAD INTERMITTENTLY STALLED WHILE STOPPED, WITH AN ERROR CODE THAT POINTED TO AN INEFFECTIVE CATALYTIC CONVERTER. I HAD MY MASS AIR FLOW SENSOR REPLACED, MY ECM RELAY REPLACED, AND MY CATALYTIC CONVERTER REPLACED, AT A COST OF ~ $5000 TOTAL. I AM NOW TOLD THE INTELLIGENT POWER DISTRIBUTION MODULE IS LIKELY THE CULPRIT FOR ALL OF THESE PROBLEMS, WHICH WILL COST ME ANOTHER $700 TO REPLACE. IN RESEARCHING PREVIOUS RECALLS, THERE IS AN EXISTING RECALL FOR THE ECM RELAY, BUT NOT THE IPDM MODULE. IT APPEARS IN OTHER TITAN FORUMS THAT SEVERAL OTHER PEOPLE HAVE SUFFERED FROM THE SAME ISSUE. *TR

NHTSA ODI #10704193

107,426 miles · Mar 20, 2015
Power Train

AS I WAS REVERSING TO BACK OUT A PARKING SPOT I FELT A HARD THUD LOOKED UNDER AND AROUND TRUCK DIDN'T SEE ANYTHING IT STARTED SNOWING AND I HAD TO USE MY 4WHEEL DRIVE AND IT WOULD NOT ENGAGE THE INDICATOR SAID IT WAS IN 4WHEEL DRIVE BUT THE FRONT WHEELS WOULD NOT TURN TOOK IT A TRANSMISSION SHOP THEY TOLD ME MY LEFT FRONT AXLE P…

Read full complaint

AS I WAS REVERSING TO BACK OUT A PARKING SPOT I FELT A HARD THUD LOOKED UNDER AND AROUND TRUCK DIDN'T SEE ANYTHING IT STARTED SNOWING AND I HAD TO USE MY 4WHEEL DRIVE AND IT WOULD NOT ENGAGE THE INDICATOR SAID IT WAS IN 4WHEEL DRIVE BUT THE FRONT WHEELS WOULD NOT TURN TOOK IT A TRANSMISSION SHOP THEY TOLD ME MY LEFT FRONT AXLE POPPED OUT OF THE DIFFERENTIAL WHICH IS A COMMON PROBLEM WITH THE TITAN I FOUND SEVERAL COMPLAINTS ABOUT THIS AND THE SAME WAY MY TRUCK AXLE POPPED OUT AND SAME SIDE CALLED NISSAN AND THEY WONT FIX THIS PROBLEM ITS VERY COSTLY AND DANGEROUS SOME PEOPLE FRONT DIFF BLEW APART I THINK SOMETHING NEEDS TO BE DONE A RECALL OR SOMETHING IT CAN CAUSE A ACCIDENT. *TR

NHTSA ODI #10695541

Official recalls

4

10V517000 · Engine And Engine Cooling

Oct 28, 2010

NISSAN IS RECALLING CERTAIN MODEL YEAR 2004-2006 ARMADA, TITAN, INFINITI QX56 AND MODEL YEAR 2005-2006 FRONTIER, PATHFINDER AND XTERRA VEHICLES. THE INTELLIGENT POWER DISTRIBUTION MODULE (IPDM) ASSEMBLY CONTAINS AN ENGINE CONTROL MODULE (ECM) RELAY THAT HAS A DIODE FOR ELECTRICAL CURRENT NOISE REDUCTION. THE ECM RELAY MAY ALLOW SILICON VAPOR TO FORM AND, OVER TIME, THE SILICON EVAPORATES FROM THE DIODE MOLDING WHICH CAUSES SILICON OXIDE TO DEVELOP ON THE ECM RELAY CONTACT DUE TO ARCING.

Consequence & remedy

Consequence: THIS COULD CAUSE ENGINE STALLING INCREASING THE RISK OF A CRASH.

Remedy: DEALERS WILL REPLACE THE ECM RELAY INSIDE THE IPDM ASSEMBLY. THIS SERVICE WILL BE PERFORMED FREE OF CHARGE. THE SAFETY RECALL BEGAN ON DECEMBER 6, 2010. OWNERS MAY CONTACT NISSAN AT 1-800-647-7261.

10V074000 · Fuel System, Other:storage:fuel Gauge System

Mar 3, 2010

NISSAN IS RECALLING CERTAIN MODEL YEAR 2005-2009 TITAN, ARMADA, AND INFINITI QX56 VEHICLES. THE INSTRUMENT PANEL FUEL GAUGE MAY INACCURATELY DISPLAY THAT THE VEHICLE STILL HAS SOME FUEL, TYPICALLY ABOUT ONE QUARTER TANK, WHEN THE FUEL TANK IS EMPTY.

Consequence & remedy

Consequence: THIS COULD CAUSE THE VEHICLE TO RUN OUT OF GAS AND STALL ON THE HIGHWAY, WHICH COULD CAUSE A CRASH.

Remedy: DEALERS WILL REPLACE THE FUEL SENDER UNIT INSIDE THE FUEL TANK WITH A NEW IMPROVED SENDER CARD. THIS SERVICE WILL BE PERFORMED FREE OF CHARGE. THE SAFETY RECALL BEGAN ON MARCH 22, 2010. OWNERS MAY CONTACT NISSAN AT 1-800-647-7261.

08V284000 · Equipment:appliance:air Conditioner

Jun 27, 2008

NISSAN IS RECALLING 180,664 MY 2005-2006 TITAN, ARMADA AND INFINITY QX56 VEHICLES MANUFACTURED AFTER MARCH 17, 2005, THAT ARE EQUIPPED WITH A VISTEON AIR CONDITIONING CONDENSER FAN MOTOR. THE FAN MOTOR MAY NOT BE PROPERLY SEALED ALLOWING EXCESSIVE WATER INTRUSION AND INADEQUATE DRAINAGE OF MOISTURE.

Consequence & remedy

Consequence: THIS COULD CAUSE CORROSION IN THE MOTOR LEADING POSSIBLY TO OVERHEATING AND A FIRE.

Remedy: DEALERS WILL INSTALL A 'THERMAL PROTECTOR KIT' AND TEST THE AIR CONDITIONING CONDENSER FAN MOTOR AND REPLACE IT IF NECESSARY. THE RECALL BEGAN ON AUGUST 2, 2008. OWNERS MAY CONTACT NISSAN AT 1-800-647-7261.

06V459000 · Electrical System

Nov 30, 2006

ON CERTAIN KING CAB TRUCKS, THE WIRES IN THE HARNESS WERE ROUTED THROUGH THE REAR DOORS AND INTO THE BODY. THESE WIRES MAY BREAK DUE TO OVER BENDING OF THE HARNESS AS THE DOOR IS OPENED AND CLOSED. THE HARNESS CONTAINS WIRES FOR THE DRIVER SEAT BELT PRETENSIONER AND FOR THE FRONT PASSENGER SEAT BELT WHICH IS PART OF THE OCCUPANT CLASSIFICATION SYSTEM. WIRES FOR THE REAR AUDIO SPEAKERS ARE ALSO CONTAINED N THE HARNESS.

Consequence & remedy

Consequence: IF THE WIRES FOR THE SEAT BELTS AND SPEAKER WIRES BREAK AND MAKE CONTACT, THERE IS A POSSIBILITY THAT THE PRETENSIONER MAY DEPLOY. IF THIS HAPPENS WHEN THE SEAT BELT IS RETRACTED, IT WILL NOT BE POSSIBLE TO USE THE SEAT BELT. IF ONE OF THE WIRES ON THE RIGHT SIDE HARNESS FOR THE SEAT BELT TENSION SENSOR BREAKS, THE PASSENGER SIDE FRONT AIR BAG WILL NOT DEPLOY AS DESIGNED IN A FRONTAL COLLISION INCREASING THE RISK OF A CRASH AND PERSONAL INJURY.

Remedy: DEALERS WILL REPLACE THE WIRE HARNESS COVER WITH A DIFFERENT TYPE THAT PREVENTS OVER BENDING OF THE HARNESS AND THE HARNESS WILL BE REROUTED FREE OF CHARGE. THE RECALL BEGAN ON FEBRUARY 19, 2007. OWNERS MAY CONTACT NISSAN AT 1-800-647-7261.

Model-level recall history does not show whether a particular VIN is affected or has received a repair. Check a VIN with NHTSA ↗

NHTSA investigations

1

PE08037 · Engine Compartment Fire

Opened May 30, 2008 · Closed Aug 25, 2008

Status: closed (inferred from source dates) · Electrical System:wiring; Electrical System:wiring:front Underhood; Engine And Engine Cooling; Engine And Engine Cooling:engine

ON MAY 30, 2008, THE OFFICE OF DEFECTS INVESTIGATION (ODI) OPENED A PRELIMINARY EVALUATION BASED ON CONSUMER COMPLAINTS ALLEGING THAT SMOKE AND/OR FIRE ERUPTED IN THE ENGINE COMPARTMENT OF MODEL YEAR (MY) 2005-2006 NISSAN ARMADA AND TITAN VEHICLES.BY LETTER DATED JUNE 24, 2008, NISSAN NOTIFIED THE NATIONAL HIGHWAY TRAFFIC SAFETY ADMINISTRATION (NHTSA) THAT IT WILL CONDUCT A SAFETY RECALL (NHTSA #08V284) FOR MY2005-2006 NISSAN TITAN, ARMADA AND INFINITI QX56 VEHICLES MANUFACTURED FROM MARCH 17, 2005 TO AUGUST 21, 2006 THAT ARE EQUIPPED WITH A 90-WATT AIR CONDITIONING CONDENSER FAN.THE RECALL INVOLVES APPROXIMATELY 180,664 VEHICLES.THIS ALSO INCLUDES APPROXIMATELY 5,689 SUBJECT CONDENSER FANS, SOME OF WHICH MAY HAVE BEEN INSTALLED IN MY2004 AND PRE-MARCH 17, 2005 MY NISSAN TITAN, ARMADA OR INFINITI QX56 VEHICLES AS A SERVICE REPLACEMENT PART.NISSAN DEALERS WILL INSTALL A SPECIAL THERMAL PROTECTOR KIT ON EXISTING FANS THAT WILL ELIMINATE THE POTENTIAL FOR A FIRE TO OCCUR.NISSAN NORTH AMERICA, INC. (NISSAN) INFORMED ODI THAT THE 90-WATT AIR CONDITIONING CONDENSER FAN WAS MANUFACTURED OUT-OF-SPECIFICATION ALLOWING FOR EXCESSIVE WATER INTRUSION AND INADEQUATE DRAINAGE OF MOISTURE THAT MAY ACCUMULATE IN THE MOTOR AS A RESULT OF WATER INTRUSION OR CONDENSATION.IF SUFFICIENT MOISTURE ACCUMULATES IN THE MOTOR WITHOUT ADEQUATE DRAINAGE, CORROSION MAY OCCUR.THE CORROSION CAN CAUSE AN INCREASE IN INTERNAL FRICTION AND AN INCREASE IN THE ELECTRICAL CURRENT DRAW, RESULTING IN AN INCREASE IN THE TEMPERATURE OF THE MOTOR THAT COULD MELT ITS WIRING INSULATION AND OTHER PLASTIC COMPONENTS AND FORM A GAS.IF TWO WIRES WITHOUT INSULATION TOUCH EACH OTHER AND CREATE A SPARK, THIS GAS COULD IGNITE AND RESULT IN A FIRE.THE ACTION TAKEN BY NISSAN IS SUFFICIENT TO RESOLVE THE ISSUE RAISED BY THIS INVESTIGATION.ACCORDINGLY, THIS INVESTIGATION IS CLOSED.

Additional source detail variants (4)

Electrical System:wiring:front Underhood

ON MAY 30, 2008, THE OFFICE OF DEFECTS INVESTIGATION (ODI) OPENED A PRELIMINARY EVALUATION BASED ON CONSUMER COMPLAINTS ALLEGING THAT SMOKE AND/OR FIRE ERUPTED IN THE ENGINE COMPARTMENT OF MODEL YEAR (MY) 2005-2006 NISSAN ARMADA AND TITAN VEHICLES.BY LETTER DATED JUNE 24, 2008, NISSAN NOTIFIED THE NATIONAL HIGHWAY TRAFFIC SAFETY ADMINISTRATION (NHTSA) THAT IT WILL CONDUCT A SAFETY RECALL (NHTSA #08V284) FOR MY2005-2006 NISSAN TITAN, ARMADA AND INFINITI QX56 VEHICLES MANUFACTURED FROM MARCH 17, 2005 TO AUGUST 21, 2006 THAT ARE EQUIPPED WITH A 90-WATT AIR CONDITIONING CONDENSER FAN.THE RECALL INVOLVES APPROXIMATELY 180,664 VEHICLES.THIS ALSO INCLUDES APPROXIMATELY 5,689 SUBJECT CONDENSER FANS, SOME OF WHICH MAY HAVE BEEN INSTALLED IN MY2004 AND PRE-MARCH 17, 2005 MY NISSAN TITAN, ARMADA OR INFINITI QX56 VEHICLES AS A SERVICE REPLACEMENT PART.NISSAN DEALERS WILL INSTALL A SPECIAL THERMAL PROTECTOR KIT ON EXISTING FANS THAT WILL ELIMINATE THE POTENTIAL FOR A FIRE TO OCCUR.NISSAN NORTH AMERICA, INC. (NISSAN) INFORMED ODI THAT THE 90-WATT AIR CONDITIONING CONDENSER FAN WAS MANUFACTURED OUT-OF-SPECIFICATION ALLOWING FOR EXCESSIVE WATER INTRUSION AND INADEQUATE DRAINAGE OF MOISTURE THAT MAY ACCUMULATE IN THE MOTOR AS A RESULT OF WATER INTRUSION OR CONDENSATION.IF SUFFICIENT MOISTURE ACCUMULATES IN THE MOTOR WITHOUT ADEQUATE DRAINAGE, CORROSION MAY OCCUR.THE CORROSION CAN CAUSE AN INCREASE IN INTERNAL FRICTION AND AN INCREASE IN THE ELECTRICAL CURRENT DRAW, RESULTING IN AN INCREASE IN THE TEMPERATURE OF THE MOTOR THAT COULD MELT ITS WIRING INSULATION AND OTHER PLASTIC COMPONENTS AND FORM A GAS.IF TWO WIRES WITHOUT INSULATION TOUCH EACH OTHER AND CREATE A SPARK, THIS GAS COULD IGNITE AND RESULT IN A FIRE.THE ACTION TAKEN BY NISSAN IS SUFFICIENT TO RESOLVE THE ISSUE RAISED BY THIS INVESTIGATION.ACCORDINGLY, THIS INVESTIGATION IS CLOSED.

Electrical System:wiring

ON MAY 30, 2008, THE OFFICE OF DEFECTS INVESTIGATION (ODI) OPENED A PRELIMINARY EVALUATION BASED ON CONSUMER COMPLAINTS ALLEGING THAT SMOKE AND/OR FIRE ERUPTED IN THE ENGINE COMPARTMENT OF MODEL YEAR (MY) 2005-2006 NISSAN ARMADA AND TITAN VEHICLES.BY LETTER DATED JUNE 24, 2008, NISSAN NOTIFIED THE NATIONAL HIGHWAY TRAFFIC SAFETY ADMINISTRATION (NHTSA) THAT IT WILL CONDUCT A SAFETY RECALL (NHTSA #08V284) FOR MY2005-2006 NISSAN TITAN, ARMADA AND INFINITI QX56 VEHICLES MANUFACTURED FROM MARCH 17, 2005 TO AUGUST 21, 2006 THAT ARE EQUIPPED WITH A 90-WATT AIR CONDITIONING CONDENSER FAN.THE RECALL INVOLVES APPROXIMATELY 180,664 VEHICLES.THIS ALSO INCLUDES APPROXIMATELY 5,689 SUBJECT CONDENSER FANS, SOME OF WHICH MAY HAVE BEEN INSTALLED IN MY2004 AND PRE-MARCH 17, 2005 MY NISSAN TITAN, ARMADA OR INFINITI QX56 VEHICLES AS A SERVICE REPLACEMENT PART.NISSAN DEALERS WILL INSTALL A SPECIAL THERMAL PROTECTOR KIT ON EXISTING FANS THAT WILL ELIMINATE THE POTENTIAL FOR A FIRE TO OCCUR.NISSAN NORTH AMERICA, INC. (NISSAN) INFORMED ODI THAT THE 90-WATT AIR CONDITIONING CONDENSER FAN WAS MANUFACTURED OUT-OF-SPECIFICATION ALLOWING FOR EXCESSIVE WATER INTRUSION AND INADEQUATE DRAINAGE OF MOISTURE THAT MAY ACCUMULATE IN THE MOTOR AS A RESULT OF WATER INTRUSION OR CONDENSATION.IF SUFFICIENT MOISTURE ACCUMULATES IN THE MOTOR WITHOUT ADEQUATE DRAINAGE, CORROSION MAY OCCUR.THE CORROSION CAN CAUSE AN INCREASE IN INTERNAL FRICTION AND AN INCREASE IN THE ELECTRICAL CURRENT DRAW, RESULTING IN AN INCREASE IN THE TEMPERATURE OF THE MOTOR THAT COULD MELT ITS WIRING INSULATION AND OTHER PLASTIC COMPONENTS AND FORM A GAS.IF TWO WIRES WITHOUT INSULATION TOUCH EACH OTHER AND CREATE A SPARK, THIS GAS COULD IGNITE AND RESULT IN A FIRE.THE ACTION TAKEN BY NISSAN IS SUFFICIENT TO RESOLVE THE ISSUE RAISED BY THIS INVESTIGATION.ACCORDINGLY, THIS INVESTIGATION IS CLOSED.

Engine And Engine Cooling:engine

ON MAY 30, 2008, THE OFFICE OF DEFECTS INVESTIGATION (ODI) OPENED A PRELIMINARY EVALUATION BASED ON CONSUMER COMPLAINTS ALLEGING THAT SMOKE AND/OR FIRE ERUPTED IN THE ENGINE COMPARTMENT OF MODEL YEAR (MY) 2005-2006 NISSAN ARMADA AND TITAN VEHICLES.BY LETTER DATED JUNE 24, 2008, NISSAN NOTIFIED THE NATIONAL HIGHWAY TRAFFIC SAFETY ADMINISTRATION (NHTSA) THAT IT WILL CONDUCT A SAFETY RECALL (NHTSA #08V284) FOR MY2005-2006 NISSAN TITAN, ARMADA AND INFINITI QX56 VEHICLES MANUFACTURED FROM MARCH 17, 2005 TO AUGUST 21, 2006 THAT ARE EQUIPPED WITH A 90-WATT AIR CONDITIONING CONDENSER FAN.THE RECALL INVOLVES APPROXIMATELY 180,664 VEHICLES.THIS ALSO INCLUDES APPROXIMATELY 5,689 SUBJECT CONDENSER FANS, SOME OF WHICH MAY HAVE BEEN INSTALLED IN MY2004 AND PRE-MARCH 17, 2005 MY NISSAN TITAN, ARMADA OR INFINITI QX56 VEHICLES AS A SERVICE REPLACEMENT PART.NISSAN DEALERS WILL INSTALL A SPECIAL THERMAL PROTECTOR KIT ON EXISTING FANS THAT WILL ELIMINATE THE POTENTIAL FOR A FIRE TO OCCUR.NISSAN NORTH AMERICA, INC. (NISSAN) INFORMED ODI THAT THE 90-WATT AIR CONDITIONING CONDENSER FAN WAS MANUFACTURED OUT-OF-SPECIFICATION ALLOWING FOR EXCESSIVE WATER INTRUSION AND INADEQUATE DRAINAGE OF MOISTURE THAT MAY ACCUMULATE IN THE MOTOR AS A RESULT OF WATER INTRUSION OR CONDENSATION.IF SUFFICIENT MOISTURE ACCUMULATES IN THE MOTOR WITHOUT ADEQUATE DRAINAGE, CORROSION MAY OCCUR.THE CORROSION CAN CAUSE AN INCREASE IN INTERNAL FRICTION AND AN INCREASE IN THE ELECTRICAL CURRENT DRAW, RESULTING IN AN INCREASE IN THE TEMPERATURE OF THE MOTOR THAT COULD MELT ITS WIRING INSULATION AND OTHER PLASTIC COMPONENTS AND FORM A GAS.IF TWO WIRES WITHOUT INSULATION TOUCH EACH OTHER AND CREATE A SPARK, THIS GAS COULD IGNITE AND RESULT IN A FIRE.THE ACTION TAKEN BY NISSAN IS SUFFICIENT TO RESOLVE THE ISSUE RAISED BY THIS INVESTIGATION.ACCORDINGLY, THIS INVESTIGATION IS CLOSED.

Engine And Engine Cooling

ON MAY 30, 2008, THE OFFICE OF DEFECTS INVESTIGATION (ODI) OPENED A PRELIMINARY EVALUATION BASED ON CONSUMER COMPLAINTS ALLEGING THAT SMOKE AND/OR FIRE ERUPTED IN THE ENGINE COMPARTMENT OF MODEL YEAR (MY) 2005-2006 NISSAN ARMADA AND TITAN VEHICLES.BY LETTER DATED JUNE 24, 2008, NISSAN NOTIFIED THE NATIONAL HIGHWAY TRAFFIC SAFETY ADMINISTRATION (NHTSA) THAT IT WILL CONDUCT A SAFETY RECALL (NHTSA #08V284) FOR MY2005-2006 NISSAN TITAN, ARMADA AND INFINITI QX56 VEHICLES MANUFACTURED FROM MARCH 17, 2005 TO AUGUST 21, 2006 THAT ARE EQUIPPED WITH A 90-WATT AIR CONDITIONING CONDENSER FAN.THE RECALL INVOLVES APPROXIMATELY 180,664 VEHICLES.THIS ALSO INCLUDES APPROXIMATELY 5,689 SUBJECT CONDENSER FANS, SOME OF WHICH MAY HAVE BEEN INSTALLED IN MY2004 AND PRE-MARCH 17, 2005 MY NISSAN TITAN, ARMADA OR INFINITI QX56 VEHICLES AS A SERVICE REPLACEMENT PART.NISSAN DEALERS WILL INSTALL A SPECIAL THERMAL PROTECTOR KIT ON EXISTING FANS THAT WILL ELIMINATE THE POTENTIAL FOR A FIRE TO OCCUR.NISSAN NORTH AMERICA, INC. (NISSAN) INFORMED ODI THAT THE 90-WATT AIR CONDITIONING CONDENSER FAN WAS MANUFACTURED OUT-OF-SPECIFICATION ALLOWING FOR EXCESSIVE WATER INTRUSION AND INADEQUATE DRAINAGE OF MOISTURE THAT MAY ACCUMULATE IN THE MOTOR AS A RESULT OF WATER INTRUSION OR CONDENSATION.IF SUFFICIENT MOISTURE ACCUMULATES IN THE MOTOR WITHOUT ADEQUATE DRAINAGE, CORROSION MAY OCCUR.THE CORROSION CAN CAUSE AN INCREASE IN INTERNAL FRICTION AND AN INCREASE IN THE ELECTRICAL CURRENT DRAW, RESULTING IN AN INCREASE IN THE TEMPERATURE OF THE MOTOR THAT COULD MELT ITS WIRING INSULATION AND OTHER PLASTIC COMPONENTS AND FORM A GAS.IF TWO WIRES WITHOUT INSULATION TOUCH EACH OTHER AND CREATE A SPARK, THIS GAS COULD IGNITE AND RESULT IN A FIRE.THE ACTION TAKEN BY NISSAN IS SUFFICIENT TO RESOLVE THE ISSUE RAISED BY THIS INVESTIGATION.ACCORDINGLY, THIS INVESTIGATION IS CLOSED.