TL*THE CONTACT OWNS A 2005 NISSAN TITAN. THE CONTACT WAS REVERSING FROM A DRIVEWAY AT RELATIVELY LOW SPEEDS WHEN THE REAR DIFFERENTIAL FAILED. THE VEHICLE WAS NOT DRIVABLE. THE DEALER ADVISED THE ENTIRE DIFFERENTIAL UNIT WOULD NEED TO BE REPLACED AT THE CONTACTS EXPENSE. THE MANUFACTURER WAS NOT CONTACTED. THE VEHICLE WAS NOT RE…
Read full complaint
TL*THE CONTACT OWNS A 2005 NISSAN TITAN. THE CONTACT WAS REVERSING FROM A DRIVEWAY AT RELATIVELY LOW SPEEDS WHEN THE REAR DIFFERENTIAL FAILED. THE VEHICLE WAS NOT DRIVABLE. THE DEALER ADVISED THE ENTIRE DIFFERENTIAL UNIT WOULD NEED TO BE REPLACED AT THE CONTACTS EXPENSE. THE MANUFACTURER WAS NOT CONTACTED. THE VEHICLE WAS NOT REPAIRED. THE FAILURE AND CURRENT MILEAGES WERE 40,000.
NHTSA ODI #10336925
63,000 miles · Jun 10, 2010
Power Train
05 NISSAN TITAN - CLUNKING SOUND I THOUGHT WAS A U-JOINT IS MY REAR END FIXING TO GO. RIGHT REAR SEAL LEAKING DIFFERENTIAL FLUID ON MY REAR BRAKES SAFETY HAZARD. IF MY REAR END WENT OUT WHILE DRIVING 70MPH WHICH I DO EVERY DAY. IT COULD BE VERY DANGEROUS MAYBE FATAL RESULT. I HAVE A 6 AND 4 YEAR OLD THAT ARE WITH ME EVERYDAY IN…
Read full complaint
05 NISSAN TITAN - CLUNKING SOUND I THOUGHT WAS A U-JOINT IS MY REAR END FIXING TO GO. RIGHT REAR SEAL LEAKING DIFFERENTIAL FLUID ON MY REAR BRAKES SAFETY HAZARD. IF MY REAR END WENT OUT WHILE DRIVING 70MPH WHICH I DO EVERY DAY. IT COULD BE VERY DANGEROUS MAYBE FATAL RESULT. I HAVE A 6 AND 4 YEAR OLD THAT ARE WITH ME EVERYDAY IN THE TRUCK. WELL KNOWN PROBLEM THAT NISSAN NEEDS TO FIX! *TR
NHTSA ODI #10335656
72,500 miles · May 31, 2010
Power Train
REAR AXLE ON MY NISSAN TITAN IS LEAKING DIFFERENTIAL FLUID ALL OVER MY BRAKES FOR THE 3RD TIME. IT IS EVIDENT THAT THE NISSAN SETUP IS NOT DOING A GOOD JOB (BAD SEALS OR BAD VENTING CAUSING PRESSURE TO DESTROY THE SEALS. THIS IS A SAFETY ISSUE BECAUSE THE OIL SEEPS ONTO THE BRAKES ONCE THE SEALS HAVE LET GO. *TR
NHTSA ODI #10333932
36,000 miles · May 29, 2010
Power Train
THE AXLE SEALS ON THE NISSAN TITAN BEGAN TO LEAK AND MANY OTHER NISSAN TITAN OWNERS HAVE HAD THIS SAME PROBLEM. MINE BEGAN TO LEAK AT 36K MILES BUT I HAVE SEEN OTHERS LEAK AS EARLY AS 18K MILES. THIS IS A COMMON PROBLEM THAT NEEDS TO BE ADDRESSED PROPERLY AND FIXED. THE DIFFERENTIAL FLUID THAT LEAKS OUT, LEAKS ONTO THE BRAKES AN…
Read full complaint
THE AXLE SEALS ON THE NISSAN TITAN BEGAN TO LEAK AND MANY OTHER NISSAN TITAN OWNERS HAVE HAD THIS SAME PROBLEM. MINE BEGAN TO LEAK AT 36K MILES BUT I HAVE SEEN OTHERS LEAK AS EARLY AS 18K MILES. THIS IS A COMMON PROBLEM THAT NEEDS TO BE ADDRESSED PROPERLY AND FIXED. THE DIFFERENTIAL FLUID THAT LEAKS OUT, LEAKS ONTO THE BRAKES AND CAN CAUSE THEM TO FAIL. I NOTICED MY AXLE SEAL WAS LEAKING AFTER MY BRAKES STARTED TO SQUEAK, GRIND, AND JOLT THE TRUCK BACK AND FORTH WHILE BRAKING. THIS HAS BEEN A PROBLEM WITH MY 2005 NISSAN TITAN AND THE PROBLEM CONTINUES TO OCCUR IN NEWER MODELS. I LOVE THE TRUCK BUT THIS PROBLEM NEEDS TO BE FIXED PROPERLY. RIGHT NOW I AM IN THE PROCESS OF REPLACING THE SEAL THROUGH MY NISSAN DEALERSHIP BUT THE PROBLEM IS STILL PRONE TO HAPPEN. *TR
NHTSA ODI #10332740
87,000 miles · May 26, 2010
Power Train
REAR DIFF WENT OUT ON MY 2005 NISSAN TITAN. IT WAS WELL MAINTAINED AND IT WENT OUT AT 87K MILES. THIS IS RIDICULOUS THAT NISSAN WILL NOT STEP UP AND PAY FOR THE ITEM THAT IS OBVIOUSLY A DEFECT. LOOK AT ALL THE COMPLAINTS. I THINK IT IS TIME FOR A CLASS ACTION LAWSUIT. *TR
NHTSA ODI #10332432
64,400 miles · May 25, 2010
Power Train
NISSAN TITAN 2005 4X4 64,400 MILES THE REAR DIFFERENTIAL STARTED JERKING AND POPPING. TOOK THE NISSAN DEALER AND THEY SAID THAT THE REAR DIFFERENTIAL SPIDER GEARS FAILED AND THE ENTIRE REAR END WOULD HAVE TO BE REPLACED. THE COST WAS $3200.00. THIS TRUCK IS MY WIFE'S REGULAR DIVER AND SHE TRANSPORTS THE KIDS TO SCHOOL IN IF THIS…
Read full complaint
NISSAN TITAN 2005 4X4 64,400 MILES THE REAR DIFFERENTIAL STARTED JERKING AND POPPING. TOOK THE NISSAN DEALER AND THEY SAID THAT THE REAR DIFFERENTIAL SPIDER GEARS FAILED AND THE ENTIRE REAR END WOULD HAVE TO BE REPLACED. THE COST WAS $3200.00. THIS TRUCK IS MY WIFE'S REGULAR DIVER AND SHE TRANSPORTS THE KIDS TO SCHOOL IN IF THIS HAD HAPPENED AT HIGH SPEED IT COULD HAVE BEEN VERY DANGEROUS. *TR
NHTSA ODI #10332269
59,000 miles · May 24, 2010
Power Train
NO EVENTS HAVE LED TO THE FAILURE OF THE REAR END OF MY 2005 TITAN 4X4. DEALER HAS IDENTIFIED LEAKING FLUID FROM THE REAR AXEL/SEALS. REAREND (AXEL) FAILURE IS IMMANENT AND WILL BE SUBSTANTIAL. THIS SAME ISSUE HAS BEEN REPORTED BY MANY TITAN OWNERS AND PRESENTS A DRIVING DANGER ON THE ROAD. I CAN'T AFFORD THE $3000 PLUS TO R…
Read full complaint
NO EVENTS HAVE LED TO THE FAILURE OF THE REAR END OF MY 2005 TITAN 4X4. DEALER HAS IDENTIFIED LEAKING FLUID FROM THE REAR AXEL/SEALS. REAREND (AXEL) FAILURE IS IMMANENT AND WILL BE SUBSTANTIAL. THIS SAME ISSUE HAS BEEN REPORTED BY MANY TITAN OWNERS AND PRESENTS A DRIVING DANGER ON THE ROAD. I CAN'T AFFORD THE $3000 PLUS TO REPLACE THE REAR AXEL. VEHICLE HAS ONLY 58,000 MILES. THIS FAILURE IS DUE TO DEFECTIVE INTERNAL PARTS, BEARINGS, ETC. IN THE REAR AXEL OF THESE TITANS TRUCKS. *TR
NHTSA ODI #10331924
Mileage unknown · May 24, 2010
Power Train
MY REAR DIFF HAS BEEN MAKING NOISES FOR THE PAST 4000 MILES. TOOK IT INTO THE SHOP TWO TIMES AND THEY COULDN'T FIND IT. NOW THE REAR IS SHOT AND IM OVER MY WARRANTY NOW BY 1000 MILES,SO THEY WONT DO NOTHING ABOUT IT. *TR
NHTSA ODI #10331919
67,800 miles · May 23, 2010
Power Train
I HAD DRIVEN FROM MY COLLEGE TO MY CHIROPRACTORS OFFICE WITHOUT ANY INCIDENTS. WHEN LEAVING MY CHIROPRACTORS OFFICE I WAS BACKING OUT OF PARKING STALL WITH WHEELS TURNED TO THE RIGHT. ALL OF A SUDDEN THERE WAS A LOUD POP. BEING A MECHANIC I THOUGHT THAT I MIGHT HAVE UJOINT ISSUES. I CLIMBED UNDER AND CHECKED MY DRIVELINE AND EV…
Read full complaint
I HAD DRIVEN FROM MY COLLEGE TO MY CHIROPRACTORS OFFICE WITHOUT ANY INCIDENTS. WHEN LEAVING MY CHIROPRACTORS OFFICE I WAS BACKING OUT OF PARKING STALL WITH WHEELS TURNED TO THE RIGHT. ALL OF A SUDDEN THERE WAS A LOUD POP. BEING A MECHANIC I THOUGHT THAT I MIGHT HAVE UJOINT ISSUES. I CLIMBED UNDER AND CHECKED MY DRIVELINE AND EVERYTHING WAS IN GOOD ORDER. I THEN DROVE BACK TO MY COLLEGE WHERE I COULD GET MY TRUCK ONTO A LIFT AND CHECK IT OUT. IN THE 12 MILES FROM THE CHIROPRACTORS OFFICE TO THE COLLEGE IT HAD PROGRESSED TO THE POINT OF NOT BEING ABLE TO DRIVE. IT WOULD BIND WHEN TURNING LEFT AND DRAG WHEELS AS THOUGHT LIMITED SLIP WAS OUT. OR WHEN TURNING TO THE LEFT IT WOULD SOUND AS THOUGH SOMEONE HAD TAKEN A 20 POUND SLEDGE HAMMER AND HIT THE TAIL SHAFT OF THE TRANSMISSION. THE REAR AXLE SEALS AND BEARINGS WERE REPLACED AT 50,000MI UNDER FACTORY WARRANTY. AFTER REVIEWING MANY CLAIMS ON THIS DIFFERENTIAL THIS WAS AN INDICATION AS TO THE REAR DIFF GOING OUT. CURRENTLY I HAVE 67,000MI ON IT AND ON THE DEALER LEVEL THEY ARE NOT WILLING TO REPLACE. HAVE A PHONE INTERVIEW WITH A NISSAN NORTH AMERICA DISTRICT REP TOMORROW AND HOPE TO HAVE THIS CLEARED UP. IF NOT THE QUOTE TO GET A NEW REAR END ASSEMBLY, SINCE YOU CANNOT JUST ORDER THE PUMPKIN, IS $3400.00. I SEE THAT THERE IS A HUGE ISSUE WITH THIS AND HOPE THAT NISSAN WILL TAKE CARE OF THIS. MY TRUCK IS A 2005 NISSAN TITAN LE CREW CAB 4X4 WITH OFFROAD AND TOW PACKAGE. NO MODS HAVE BEEN DONE TO TRUCK WITH EXCEPTION OF PUTTING ON NERF BARS. EVERYTHING ELSE IS WHAT NISSAN SENT IT OUT THE DOORS WITH. THANK YOU *TR
NHTSA ODI #10331857
84,256 miles · May 19, 2010
Power Train
WHILE ROLLING FROM A STOP DRIVING A NISSAN 2005 TITAN TRUCK WITH 84,200 MILES ON IT, I HEARD A NOISE AND SUBSEQUENT CLANGING SOUND. LATER THAT DAY I INVESTIGATED THE SOUND AND DETERMINED IT WAS COMING FROM THE REAR OF THE VEHICLE AND THE PROBLEM WAS PROBABLY THE REAR DIFFERENTIAL. I TOOK IT TO A NISSAN DEALER WHO LATER DETERMI…
Read full complaint
WHILE ROLLING FROM A STOP DRIVING A NISSAN 2005 TITAN TRUCK WITH 84,200 MILES ON IT, I HEARD A NOISE AND SUBSEQUENT CLANGING SOUND. LATER THAT DAY I INVESTIGATED THE SOUND AND DETERMINED IT WAS COMING FROM THE REAR OF THE VEHICLE AND THE PROBLEM WAS PROBABLY THE REAR DIFFERENTIAL. I TOOK IT TO A NISSAN DEALER WHO LATER DETERMINED THAT THE PINION GEAR LOSS A TOOTH/TEETH. AFTER FURTHER INVESTIGATION I DETERMINED THE ONLY WAY TO FIX THE PROBLEM WAS TO INSTALL THE WHOLE REAR END ASSEMBLY INCLUDING HOUSING, GEARS, AND AXLES COSTING $3100 AT THE NISSAN DEALER. THERE IS A SAFETY PROBLEM WITH NISSAN WHICH NEEDS TO BE INVESTIGATED. *TR
NISSAN IS RECALLING CERTAIN MODEL YEAR 2004-2006 ARMADA, TITAN, INFINITI QX56 AND MODEL YEAR 2005-2006 FRONTIER, PATHFINDER AND XTERRA VEHICLES. THE INTELLIGENT POWER DISTRIBUTION MODULE (IPDM) ASSEMBLY CONTAINS AN ENGINE CONTROL MODULE (ECM) RELAY THAT HAS A DIODE FOR ELECTRICAL CURRENT NOISE REDUCTION. THE ECM RELAY MAY ALLOW SILICON VAPOR TO FORM AND, OVER TIME, THE SILICON EVAPORATES FROM THE DIODE MOLDING WHICH CAUSES SILICON OXIDE TO DEVELOP ON THE ECM RELAY CONTACT DUE TO ARCING.
Consequence & remedy
Consequence: THIS COULD CAUSE ENGINE STALLING INCREASING THE RISK OF A CRASH.
Remedy: DEALERS WILL REPLACE THE ECM RELAY INSIDE THE IPDM ASSEMBLY. THIS SERVICE WILL BE PERFORMED FREE OF CHARGE. THE SAFETY RECALL BEGAN ON DECEMBER 6, 2010. OWNERS MAY CONTACT NISSAN AT 1-800-647-7261.
NISSAN IS RECALLING CERTAIN MODEL YEAR 2005-2009 TITAN, ARMADA, AND INFINITI QX56 VEHICLES. THE INSTRUMENT PANEL FUEL GAUGE MAY INACCURATELY DISPLAY THAT THE VEHICLE STILL HAS SOME FUEL, TYPICALLY ABOUT ONE QUARTER TANK, WHEN THE FUEL TANK IS EMPTY.
Consequence & remedy
Consequence: THIS COULD CAUSE THE VEHICLE TO RUN OUT OF GAS AND STALL ON THE HIGHWAY, WHICH COULD CAUSE A CRASH.
Remedy: DEALERS WILL REPLACE THE FUEL SENDER UNIT INSIDE THE FUEL TANK WITH A NEW IMPROVED SENDER CARD. THIS SERVICE WILL BE PERFORMED FREE OF CHARGE. THE SAFETY RECALL BEGAN ON MARCH 22, 2010. OWNERS MAY CONTACT NISSAN AT 1-800-647-7261.
NISSAN IS RECALLING 180,664 MY 2005-2006 TITAN, ARMADA AND INFINITY QX56 VEHICLES MANUFACTURED AFTER MARCH 17, 2005, THAT ARE EQUIPPED WITH A VISTEON AIR CONDITIONING CONDENSER FAN MOTOR. THE FAN MOTOR MAY NOT BE PROPERLY SEALED ALLOWING EXCESSIVE WATER INTRUSION AND INADEQUATE DRAINAGE OF MOISTURE.
Consequence & remedy
Consequence: THIS COULD CAUSE CORROSION IN THE MOTOR LEADING POSSIBLY TO OVERHEATING AND A FIRE.
Remedy: DEALERS WILL INSTALL A 'THERMAL PROTECTOR KIT' AND TEST THE AIR CONDITIONING CONDENSER FAN MOTOR AND REPLACE IT IF NECESSARY. THE RECALL BEGAN ON AUGUST 2, 2008. OWNERS MAY CONTACT NISSAN AT 1-800-647-7261.
ON CERTAIN KING CAB TRUCKS, THE WIRES IN THE HARNESS WERE ROUTED THROUGH THE REAR DOORS AND INTO THE BODY. THESE WIRES MAY BREAK DUE TO OVER BENDING OF THE HARNESS AS THE DOOR IS OPENED AND CLOSED. THE HARNESS CONTAINS WIRES FOR THE DRIVER SEAT BELT PRETENSIONER AND FOR THE FRONT PASSENGER SEAT BELT WHICH IS PART OF THE OCCUPANT CLASSIFICATION SYSTEM. WIRES FOR THE REAR AUDIO SPEAKERS ARE ALSO CONTAINED N THE HARNESS.
Consequence & remedy
Consequence: IF THE WIRES FOR THE SEAT BELTS AND SPEAKER WIRES BREAK AND MAKE CONTACT, THERE IS A POSSIBILITY THAT THE PRETENSIONER MAY DEPLOY. IF THIS HAPPENS WHEN THE SEAT BELT IS RETRACTED, IT WILL NOT BE POSSIBLE TO USE THE SEAT BELT. IF ONE OF THE WIRES ON THE RIGHT SIDE HARNESS FOR THE SEAT BELT TENSION SENSOR BREAKS, THE PASSENGER SIDE FRONT AIR BAG WILL NOT DEPLOY AS DESIGNED IN A FRONTAL COLLISION INCREASING THE RISK OF A CRASH AND PERSONAL INJURY.
Remedy: DEALERS WILL REPLACE THE WIRE HARNESS COVER WITH A DIFFERENT TYPE THAT PREVENTS OVER BENDING OF THE HARNESS AND THE HARNESS WILL BE REROUTED FREE OF CHARGE. THE RECALL BEGAN ON FEBRUARY 19, 2007. OWNERS MAY CONTACT NISSAN AT 1-800-647-7261.
Model-level recall history does not show whether a particular VIN is affected or has received a repair. Check a VIN with NHTSA ↗
NHTSA investigations
1
PE08037 · Engine Compartment Fire
Opened May 30, 2008 · Closed Aug 25, 2008
Status: closed (inferred from source dates) · Electrical System:wiring; Electrical System:wiring:front Underhood; Engine And Engine Cooling; Engine And Engine Cooling:engine
ON MAY 30, 2008, THE OFFICE OF DEFECTS INVESTIGATION (ODI) OPENED A PRELIMINARY EVALUATION BASED ON CONSUMER COMPLAINTS ALLEGING THAT SMOKE AND/OR FIRE ERUPTED IN THE ENGINE COMPARTMENT OF MODEL YEAR (MY) 2005-2006 NISSAN ARMADA AND TITAN VEHICLES.BY LETTER DATED JUNE 24, 2008, NISSAN NOTIFIED THE NATIONAL HIGHWAY TRAFFIC SAFETY ADMINISTRATION (NHTSA) THAT IT WILL CONDUCT A SAFETY RECALL (NHTSA #08V284) FOR MY2005-2006 NISSAN TITAN, ARMADA AND INFINITI QX56 VEHICLES MANUFACTURED FROM MARCH 17, 2005 TO AUGUST 21, 2006 THAT ARE EQUIPPED WITH A 90-WATT AIR CONDITIONING CONDENSER FAN.THE RECALL INVOLVES APPROXIMATELY 180,664 VEHICLES.THIS ALSO INCLUDES APPROXIMATELY 5,689 SUBJECT CONDENSER FANS, SOME OF WHICH MAY HAVE BEEN INSTALLED IN MY2004 AND PRE-MARCH 17, 2005 MY NISSAN TITAN, ARMADA OR INFINITI QX56 VEHICLES AS A SERVICE REPLACEMENT PART.NISSAN DEALERS WILL INSTALL A SPECIAL THERMAL PROTECTOR KIT ON EXISTING FANS THAT WILL ELIMINATE THE POTENTIAL FOR A FIRE TO OCCUR.NISSAN NORTH AMERICA, INC. (NISSAN) INFORMED ODI THAT THE 90-WATT AIR CONDITIONING CONDENSER FAN WAS MANUFACTURED OUT-OF-SPECIFICATION ALLOWING FOR EXCESSIVE WATER INTRUSION AND INADEQUATE DRAINAGE OF MOISTURE THAT MAY ACCUMULATE IN THE MOTOR AS A RESULT OF WATER INTRUSION OR CONDENSATION.IF SUFFICIENT MOISTURE ACCUMULATES IN THE MOTOR WITHOUT ADEQUATE DRAINAGE, CORROSION MAY OCCUR.THE CORROSION CAN CAUSE AN INCREASE IN INTERNAL FRICTION AND AN INCREASE IN THE ELECTRICAL CURRENT DRAW, RESULTING IN AN INCREASE IN THE TEMPERATURE OF THE MOTOR THAT COULD MELT ITS WIRING INSULATION AND OTHER PLASTIC COMPONENTS AND FORM A GAS.IF TWO WIRES WITHOUT INSULATION TOUCH EACH OTHER AND CREATE A SPARK, THIS GAS COULD IGNITE AND RESULT IN A FIRE.THE ACTION TAKEN BY NISSAN IS SUFFICIENT TO RESOLVE THE ISSUE RAISED BY THIS INVESTIGATION.ACCORDINGLY, THIS INVESTIGATION IS CLOSED.
Additional source detail variants (4)
Electrical System:wiring:front Underhood
ON MAY 30, 2008, THE OFFICE OF DEFECTS INVESTIGATION (ODI) OPENED A PRELIMINARY EVALUATION BASED ON CONSUMER COMPLAINTS ALLEGING THAT SMOKE AND/OR FIRE ERUPTED IN THE ENGINE COMPARTMENT OF MODEL YEAR (MY) 2005-2006 NISSAN ARMADA AND TITAN VEHICLES.BY LETTER DATED JUNE 24, 2008, NISSAN NOTIFIED THE NATIONAL HIGHWAY TRAFFIC SAFETY ADMINISTRATION (NHTSA) THAT IT WILL CONDUCT A SAFETY RECALL (NHTSA #08V284) FOR MY2005-2006 NISSAN TITAN, ARMADA AND INFINITI QX56 VEHICLES MANUFACTURED FROM MARCH 17, 2005 TO AUGUST 21, 2006 THAT ARE EQUIPPED WITH A 90-WATT AIR CONDITIONING CONDENSER FAN.THE RECALL INVOLVES APPROXIMATELY 180,664 VEHICLES.THIS ALSO INCLUDES APPROXIMATELY 5,689 SUBJECT CONDENSER FANS, SOME OF WHICH MAY HAVE BEEN INSTALLED IN MY2004 AND PRE-MARCH 17, 2005 MY NISSAN TITAN, ARMADA OR INFINITI QX56 VEHICLES AS A SERVICE REPLACEMENT PART.NISSAN DEALERS WILL INSTALL A SPECIAL THERMAL PROTECTOR KIT ON EXISTING FANS THAT WILL ELIMINATE THE POTENTIAL FOR A FIRE TO OCCUR.NISSAN NORTH AMERICA, INC. (NISSAN) INFORMED ODI THAT THE 90-WATT AIR CONDITIONING CONDENSER FAN WAS MANUFACTURED OUT-OF-SPECIFICATION ALLOWING FOR EXCESSIVE WATER INTRUSION AND INADEQUATE DRAINAGE OF MOISTURE THAT MAY ACCUMULATE IN THE MOTOR AS A RESULT OF WATER INTRUSION OR CONDENSATION.IF SUFFICIENT MOISTURE ACCUMULATES IN THE MOTOR WITHOUT ADEQUATE DRAINAGE, CORROSION MAY OCCUR.THE CORROSION CAN CAUSE AN INCREASE IN INTERNAL FRICTION AND AN INCREASE IN THE ELECTRICAL CURRENT DRAW, RESULTING IN AN INCREASE IN THE TEMPERATURE OF THE MOTOR THAT COULD MELT ITS WIRING INSULATION AND OTHER PLASTIC COMPONENTS AND FORM A GAS.IF TWO WIRES WITHOUT INSULATION TOUCH EACH OTHER AND CREATE A SPARK, THIS GAS COULD IGNITE AND RESULT IN A FIRE.THE ACTION TAKEN BY NISSAN IS SUFFICIENT TO RESOLVE THE ISSUE RAISED BY THIS INVESTIGATION.ACCORDINGLY, THIS INVESTIGATION IS CLOSED.
Electrical System:wiring
ON MAY 30, 2008, THE OFFICE OF DEFECTS INVESTIGATION (ODI) OPENED A PRELIMINARY EVALUATION BASED ON CONSUMER COMPLAINTS ALLEGING THAT SMOKE AND/OR FIRE ERUPTED IN THE ENGINE COMPARTMENT OF MODEL YEAR (MY) 2005-2006 NISSAN ARMADA AND TITAN VEHICLES.BY LETTER DATED JUNE 24, 2008, NISSAN NOTIFIED THE NATIONAL HIGHWAY TRAFFIC SAFETY ADMINISTRATION (NHTSA) THAT IT WILL CONDUCT A SAFETY RECALL (NHTSA #08V284) FOR MY2005-2006 NISSAN TITAN, ARMADA AND INFINITI QX56 VEHICLES MANUFACTURED FROM MARCH 17, 2005 TO AUGUST 21, 2006 THAT ARE EQUIPPED WITH A 90-WATT AIR CONDITIONING CONDENSER FAN.THE RECALL INVOLVES APPROXIMATELY 180,664 VEHICLES.THIS ALSO INCLUDES APPROXIMATELY 5,689 SUBJECT CONDENSER FANS, SOME OF WHICH MAY HAVE BEEN INSTALLED IN MY2004 AND PRE-MARCH 17, 2005 MY NISSAN TITAN, ARMADA OR INFINITI QX56 VEHICLES AS A SERVICE REPLACEMENT PART.NISSAN DEALERS WILL INSTALL A SPECIAL THERMAL PROTECTOR KIT ON EXISTING FANS THAT WILL ELIMINATE THE POTENTIAL FOR A FIRE TO OCCUR.NISSAN NORTH AMERICA, INC. (NISSAN) INFORMED ODI THAT THE 90-WATT AIR CONDITIONING CONDENSER FAN WAS MANUFACTURED OUT-OF-SPECIFICATION ALLOWING FOR EXCESSIVE WATER INTRUSION AND INADEQUATE DRAINAGE OF MOISTURE THAT MAY ACCUMULATE IN THE MOTOR AS A RESULT OF WATER INTRUSION OR CONDENSATION.IF SUFFICIENT MOISTURE ACCUMULATES IN THE MOTOR WITHOUT ADEQUATE DRAINAGE, CORROSION MAY OCCUR.THE CORROSION CAN CAUSE AN INCREASE IN INTERNAL FRICTION AND AN INCREASE IN THE ELECTRICAL CURRENT DRAW, RESULTING IN AN INCREASE IN THE TEMPERATURE OF THE MOTOR THAT COULD MELT ITS WIRING INSULATION AND OTHER PLASTIC COMPONENTS AND FORM A GAS.IF TWO WIRES WITHOUT INSULATION TOUCH EACH OTHER AND CREATE A SPARK, THIS GAS COULD IGNITE AND RESULT IN A FIRE.THE ACTION TAKEN BY NISSAN IS SUFFICIENT TO RESOLVE THE ISSUE RAISED BY THIS INVESTIGATION.ACCORDINGLY, THIS INVESTIGATION IS CLOSED.
Engine And Engine Cooling:engine
ON MAY 30, 2008, THE OFFICE OF DEFECTS INVESTIGATION (ODI) OPENED A PRELIMINARY EVALUATION BASED ON CONSUMER COMPLAINTS ALLEGING THAT SMOKE AND/OR FIRE ERUPTED IN THE ENGINE COMPARTMENT OF MODEL YEAR (MY) 2005-2006 NISSAN ARMADA AND TITAN VEHICLES.BY LETTER DATED JUNE 24, 2008, NISSAN NOTIFIED THE NATIONAL HIGHWAY TRAFFIC SAFETY ADMINISTRATION (NHTSA) THAT IT WILL CONDUCT A SAFETY RECALL (NHTSA #08V284) FOR MY2005-2006 NISSAN TITAN, ARMADA AND INFINITI QX56 VEHICLES MANUFACTURED FROM MARCH 17, 2005 TO AUGUST 21, 2006 THAT ARE EQUIPPED WITH A 90-WATT AIR CONDITIONING CONDENSER FAN.THE RECALL INVOLVES APPROXIMATELY 180,664 VEHICLES.THIS ALSO INCLUDES APPROXIMATELY 5,689 SUBJECT CONDENSER FANS, SOME OF WHICH MAY HAVE BEEN INSTALLED IN MY2004 AND PRE-MARCH 17, 2005 MY NISSAN TITAN, ARMADA OR INFINITI QX56 VEHICLES AS A SERVICE REPLACEMENT PART.NISSAN DEALERS WILL INSTALL A SPECIAL THERMAL PROTECTOR KIT ON EXISTING FANS THAT WILL ELIMINATE THE POTENTIAL FOR A FIRE TO OCCUR.NISSAN NORTH AMERICA, INC. (NISSAN) INFORMED ODI THAT THE 90-WATT AIR CONDITIONING CONDENSER FAN WAS MANUFACTURED OUT-OF-SPECIFICATION ALLOWING FOR EXCESSIVE WATER INTRUSION AND INADEQUATE DRAINAGE OF MOISTURE THAT MAY ACCUMULATE IN THE MOTOR AS A RESULT OF WATER INTRUSION OR CONDENSATION.IF SUFFICIENT MOISTURE ACCUMULATES IN THE MOTOR WITHOUT ADEQUATE DRAINAGE, CORROSION MAY OCCUR.THE CORROSION CAN CAUSE AN INCREASE IN INTERNAL FRICTION AND AN INCREASE IN THE ELECTRICAL CURRENT DRAW, RESULTING IN AN INCREASE IN THE TEMPERATURE OF THE MOTOR THAT COULD MELT ITS WIRING INSULATION AND OTHER PLASTIC COMPONENTS AND FORM A GAS.IF TWO WIRES WITHOUT INSULATION TOUCH EACH OTHER AND CREATE A SPARK, THIS GAS COULD IGNITE AND RESULT IN A FIRE.THE ACTION TAKEN BY NISSAN IS SUFFICIENT TO RESOLVE THE ISSUE RAISED BY THIS INVESTIGATION.ACCORDINGLY, THIS INVESTIGATION IS CLOSED.
Engine And Engine Cooling
ON MAY 30, 2008, THE OFFICE OF DEFECTS INVESTIGATION (ODI) OPENED A PRELIMINARY EVALUATION BASED ON CONSUMER COMPLAINTS ALLEGING THAT SMOKE AND/OR FIRE ERUPTED IN THE ENGINE COMPARTMENT OF MODEL YEAR (MY) 2005-2006 NISSAN ARMADA AND TITAN VEHICLES.BY LETTER DATED JUNE 24, 2008, NISSAN NOTIFIED THE NATIONAL HIGHWAY TRAFFIC SAFETY ADMINISTRATION (NHTSA) THAT IT WILL CONDUCT A SAFETY RECALL (NHTSA #08V284) FOR MY2005-2006 NISSAN TITAN, ARMADA AND INFINITI QX56 VEHICLES MANUFACTURED FROM MARCH 17, 2005 TO AUGUST 21, 2006 THAT ARE EQUIPPED WITH A 90-WATT AIR CONDITIONING CONDENSER FAN.THE RECALL INVOLVES APPROXIMATELY 180,664 VEHICLES.THIS ALSO INCLUDES APPROXIMATELY 5,689 SUBJECT CONDENSER FANS, SOME OF WHICH MAY HAVE BEEN INSTALLED IN MY2004 AND PRE-MARCH 17, 2005 MY NISSAN TITAN, ARMADA OR INFINITI QX56 VEHICLES AS A SERVICE REPLACEMENT PART.NISSAN DEALERS WILL INSTALL A SPECIAL THERMAL PROTECTOR KIT ON EXISTING FANS THAT WILL ELIMINATE THE POTENTIAL FOR A FIRE TO OCCUR.NISSAN NORTH AMERICA, INC. (NISSAN) INFORMED ODI THAT THE 90-WATT AIR CONDITIONING CONDENSER FAN WAS MANUFACTURED OUT-OF-SPECIFICATION ALLOWING FOR EXCESSIVE WATER INTRUSION AND INADEQUATE DRAINAGE OF MOISTURE THAT MAY ACCUMULATE IN THE MOTOR AS A RESULT OF WATER INTRUSION OR CONDENSATION.IF SUFFICIENT MOISTURE ACCUMULATES IN THE MOTOR WITHOUT ADEQUATE DRAINAGE, CORROSION MAY OCCUR.THE CORROSION CAN CAUSE AN INCREASE IN INTERNAL FRICTION AND AN INCREASE IN THE ELECTRICAL CURRENT DRAW, RESULTING IN AN INCREASE IN THE TEMPERATURE OF THE MOTOR THAT COULD MELT ITS WIRING INSULATION AND OTHER PLASTIC COMPONENTS AND FORM A GAS.IF TWO WIRES WITHOUT INSULATION TOUCH EACH OTHER AND CREATE A SPARK, THIS GAS COULD IGNITE AND RESULT IN A FIRE.THE ACTION TAKEN BY NISSAN IS SUFFICIENT TO RESOLVE THE ISSUE RAISED BY THIS INVESTIGATION.ACCORDINGLY, THIS INVESTIGATION IS CLOSED.
2005 Nissan Titan Problems, Complaints & Recalls | Skip That Year