← New search

2001 Nissan Maxima

Owner reports · Recalls · Investigations

Similar to other model years

Owner complaints for the 2001 Nissan Maxima do not stand out strongly from the model-year median of 99.

About this comparison →

When problems were reported

Mileage at the reported incident

117 reports with mileage · 55 unknown

NHTSA’s mileage field refers to the reported incident, not necessarily the filing date. This shows report counts, not the likelihood of a failure.

What to inspect

Issues worth paying extra attention to based on owner reports.

  • Air Bags. Review the 29 owner reports in this category and discuss these concerns during a pre-purchase inspection. Read reports →
  • Engine And Engine Cooling. Review the 28 owner reports in this category and discuss these concerns during a pre-purchase inspection. Read reports →
  • Electrical System. Review the 27 owner reports in this category and discuss these concerns during a pre-purchase inspection. Read reports →

NHTSA owner reports · September 18, 2026 snapshot.

8 crash reports4 fire reports6 injury reports

Electrical System complaints

27 reports
Clear category filter
58,000 miles · Nov 22, 2004
Electrical System

HIGHWAY DRIVING, CAR JERKS AND SPUTTERS, COULD CAUSE A CRASH SES LIGHT CAME ON, CAR IDLES ROUGH, CAR STALLS REPLACED ALL 6 IGNITION COILS, PROBLEM RECURRED A FEW DAYS LATER. *JB

NHTSA ODI #10100336

22,000 miles · Oct 11, 2004
Electrical System

I HAVE HAD A CONTINUOUS PROBLEM WITH MY 2001 NISSAN MAXIMA COLD START SENSOR AND THE DEALER SAYS NO RECALL HAS BEEN ISSUED. HAS ANYONE ELSE REPORTED THIS PROBLEM? ALSO, I WAS NEVER SENT A RECALL FOR THE SUSPENSION, CONTROL ARM: LOWER ARM. IS IT TO LATE TO HAVE THIS REPLACED? WHY WAS I NOT CONTACTED OR WHY DEALER DIDN'T NOTIF…

Read full complaint

I HAVE HAD A CONTINUOUS PROBLEM WITH MY 2001 NISSAN MAXIMA COLD START SENSOR AND THE DEALER SAYS NO RECALL HAS BEEN ISSUED. HAS ANYONE ELSE REPORTED THIS PROBLEM? ALSO, I WAS NEVER SENT A RECALL FOR THE SUSPENSION, CONTROL ARM: LOWER ARM. IS IT TO LATE TO HAVE THIS REPLACED? WHY WAS I NOT CONTACTED OR WHY DEALER DIDN'T NOTIFY ME? WHAT CAN I DO BECAUSE MY FRONT END IS MAKING NOISES? *NM

NHTSA ODI #10093936

Mileage unknown · Apr 29, 2004
Electrical System

CONTROL FOR HEAT & A/C REFUSED TO WORK. THERE WAS N HEAT IN THE CAR AND A/C LIGHT STAYED ON. DEALER ALLEGEDLY REPAIRED SAME AND IT LASTED A FEW MINUTES AND HEAT WENT OFF AGAIN. CURRENTLY SITUATION IS REVERSED I NOW HAVE HEAT BUT NO A/C. COMPLAINED TO NISSAN ON 11/11/03 - COMPLAINT #4329371, & 4/29/04 COMPLAINT #4521901

NHTSA ODI #10068062

45,650 miles · Dec 26, 2003
Electrical System

APPROX 1 MO AGO MY BATTERY AND BRAKE LIGHT WOULD LIGHT INTERMITTENTLY WITH NO MECHANICAL EFFECT NOTED. THE BATTERY AND ALTERNATOR TESTED GOOD AND THE CAUSE WAS UNKNOWN. THEN ONE DAY ON THE HIGHWAY WITH CRUISE CONTROL AT 75 MPH THE LIGHTS CAME ON. SEVERAL MINUTES LATER THE CRUISE CONTROL SHUT OFF BY ITSELF AND THE ABS LIGHT CA…

Read full complaint

APPROX 1 MO AGO MY BATTERY AND BRAKE LIGHT WOULD LIGHT INTERMITTENTLY WITH NO MECHANICAL EFFECT NOTED. THE BATTERY AND ALTERNATOR TESTED GOOD AND THE CAUSE WAS UNKNOWN. THEN ONE DAY ON THE HIGHWAY WITH CRUISE CONTROL AT 75 MPH THE LIGHTS CAME ON. SEVERAL MINUTES LATER THE CRUISE CONTROL SHUT OFF BY ITSELF AND THE ABS LIGHT CAME ON AND THE AIRBAG LIGHT BEGAN FLASHING. DURING SLOWING TO EXIT THE THE HIGHWAY ALL THE INSTRUMENT PANELS BEGAN 'BOUNCING' WITH UNSTABLE READINGS AND THE ENGINE SEEMED AS IF IT WAS GOING TO DIE. I EXITED TO THE SHOULDER OF THE HIGHWAY AND PUT THE CAR IN PARK AND TURNED THE CAR OFF. THE CAR REQUIRED A JUMP TO RESTART IT. I REPLACED THE BATTERY SINCE ONE CELL WAS PARTIALLY BAD. NONETHELESS, THE BATTERY AND BRAKE LIGHT HAVE COME ON AGAIN. NISSAN INDICATES A NEW ALTERNATOR IS REQUIRED ON THE CAR AT 3 YEARS OLD AND 45,700 MILES. *AK

NHTSA ODI #10051143

14,125 miles · Dec 12, 2003
Electrical SystemStructureSuspension

VEHICLE WASN'T PART OF THE RECALL REGARDING THE SUSPENSION DUE TO THE VIN, BUT EXPERIENCED THE PROBLEM STATED ON THE RECALL. *LA THE VEHICLE HAD TO GET A REALIGNMENT, THE BOTTOM COVER WAS LOOSE AND THE VEHICLE CONSTANTLY PULLED TO THE RIGHT/LEFT AND THERE WAS AN ALTERNATOR PROBLEM WHERE THE BATTERY DID NOT CHARGE. THE CONS…

Read full complaint

VEHICLE WASN'T PART OF THE RECALL REGARDING THE SUSPENSION DUE TO THE VIN, BUT EXPERIENCED THE PROBLEM STATED ON THE RECALL. *LA THE VEHICLE HAD TO GET A REALIGNMENT, THE BOTTOM COVER WAS LOOSE AND THE VEHICLE CONSTANTLY PULLED TO THE RIGHT/LEFT AND THERE WAS AN ALTERNATOR PROBLEM WHERE THE BATTERY DID NOT CHARGE. THE CONSUMER REQUESTED ASSISTANCE WITH GETTING THE VEHICLE FULLY CHECKED SINCE THE PROBLEMS ENCOUNTERED OCCURRED DURING THE WARRANTY PERIOD. RECALL#02V146000. *SC *JB

NHTSA ODI #10051667

Mileage unknown · Aug 7, 2002
Electrical SystemFire

CONSUMER TURNED OFF ENGINE AND NOTICED SMOKE, THE VEHICLE WAS TAKEN TO THE DEALER WHERE IT WAS DETERMINED THAT THE WIRE ON THE ELECTRONIC MOTOR MOUNT WIRING CAUGHT ON FIRE AND BURNED. *AK

NHTSA ODI #8015723

Mileage unknown · Jan 2, 2002
Electrical System

WHILE DRIVING, CONSUMER SMELLED SMOKE, CONSUMER THEN PULLED OVER AND LIFTED HOOD AND FOUND HEAVY SMOKE AND WIRES BURNING, CONSUMER CUT OFF ENGINE AND BURNING STOPPED, THEN CALLED AAA.*AK

NHTSA ODI #8001388

Official recalls

3

20V008000 · Air Bags:frontal:passenger Side:inflator Module

Jan 9, 2020

Nissan North America, Inc. (Nissan) is recalling certain 2001-2003 Maxima, 2002-2006 Sentra, 2002-2004 Pathfinder, 2007-2011 Versa Sedan and Versa Hatchback, 2001-2004 Infiniti I30 and I35, 2002-2003 Inifiniti QX4, 2003-2008 Infiniti FX35 and FX45 and 2006-2010 M35 and M45 vehicles. The vehicles are equipped with non-desiccated, frontal passenger air bag inflators containing phase stabilized ammonium nitrate (PSAN) propellant that were used as interim remedy parts for previous Takata recalls. These inflators may explode due to propellant degradation occurring after long-term exposure to high absolute humidity, high temperatures, and high temperature cycling.

Consequence & remedy

Consequence: An inflator explosion may result in sharp metal fragments striking the driver or other occupants resulting in serious injury or death.

Remedy: Nissan will notify owners, and dealers will replace the front passenger air bag inflators with alternate desiccated inflators, free of charge. The recall began February 12, 2020. Owners may contact Nissan customer service at 888-737-9511 or Infiniti customer service at 888-810-3715.

15V287000 · Air Bags

May 15, 2015

Nissan North America, Inc. (Nissan) is recalling certain model year 2001-2003 Nissan Maxima, 2002-2004 Pathfinder, 2002-2006 Sentra, 2002-2003 Infiniti QX4 and I35, 2003 FX35 and FX45, and 2001 I30 vehicles. Upon deployment of the passenger side frontal air bag, excessive internal pressure may cause the inflator to rupture.

Consequence & remedy

Consequence: In the event of a crash necessitating deployment of the passenger's frontal air bag, the inflator could rupture with metal fragments striking the vehicle occupants potentially resulting in serious injury or death.

Remedy: Nissan will notify owners, and dealers will replace the passenger air bag inflator, free of charge. The recall began on June 15, 2015. Owners may contact Nissan customer service at 1-800-647-7261. Note: On December 18, 2015 Nissan informed NHTSA of an amendment of this recall to remove 2004-2005 Infiniti FX35 and FX45 vehicles.

02V146000 · Suspension:front:control Arm:lower Arm

May 30, 2002

ON CERTAIN PASSENGER VEHICLES, THE PIN AT THE END OF THE FRONT SUSPENSION TRANSVERSE LINK (LOWER CONTROL ARM) COULD BREAK WHERE IT IS MOUNTED TO THE FRAME.

Consequence & remedy

Consequence: THIS CAN CAUSE A KNOCKING SOUND AND ABNORMAL STEERING. THIS COULD RESULT IN DIFFICULTY CONTROLLING THE VEHICLE AND INCREASING THE RISK OF A CRASH.

Remedy: DEALERS WILL REPLACE THE TRANSVERSE LINKS ON THE LEFT AND RIGHT SIDES WITH NEW ONES. OWNER NOTIFICATION BEGAN JULY 29, 2002. OWNERS WHO TAKE THEIR VEHICLES TO AN AUTHORIZED DEALER ON AN AGREED UPON SERVICE DATE AND DO NOT RECEIVE THE FREE REMEDY WITHIN A REASONABLE TIME SHOULD CONTACT NISSAN AT 1-800-647-7261 OR INFINITI AT 1-800-662-6200.

Model-level recall history does not show whether a particular VIN is affected or has received a repair. Check a VIN with NHTSA ↗

NHTSA investigations

1

EA21002 · Desiccated Air Bag Inflator Rupture

Opened Sep 17, 2021 · No close date supplied

Status: open (inferred from source dates) · Air Bags:frontal:driver Side:inflator Module; Air Bags:frontal:passenger Side:inflator Module

From 2000 through 2017, Takata produced millions of air bag inflators using two types of phase-stabilized ammonium nitrate ("PSAN") propellant -- propellant 2004 and propellant 2004L. After prolonged exposure to high temperature cycles and humidity, inflators using propellant 2004 can degrade, causing the propellant to burn too quickly when ignited. The rapid burning can cause the inflator to rupture during deployment, potentially causing serious or even fatal injury to vehicle occupants. See 2016 Blomquist Report at www.nhtsa.gov/sites/nhtsa.gov/files/documents/expert_report-hrblomquist.pdf.Consequently, all frontal inflators using propellant 2004 that do not contain a "desiccant" (a substance that traps and holds moisture) in US vehicles are under recall. These "non-desiccated" inflators either have been or are required to be replaced.In some cases, the remedy part for these recalled inflators was, or will be, an inflator using either propellant 2004 or 2004L that does contain a desiccant. None of these "desiccated" remedy parts (which were installed in older model year vehicles) are currently under recall for a degradation concern. Certain subsets of desiccated PSAN inflators using propellant 2004 for use as original equipment, however, have been recalled for a degradation concern. All Takata inflators produced with propellant 2004L contain desiccant, and none of these desiccated inflators using propellant 2004L are under recall for a degradation concern. There have been no reported field ruptures in any non-recalled desiccated PSAN inflators.It is understood that desiccants fully saturate at some threshold, at which point any additional moisture will not be captured. This means the degradation process observed in non-desiccated inflators using propellant 2004 may also occur in non-recalled desiccated inflators using propellant 2004, assuming additional moisture enters the inflator and high temperature cycling occurs. Based on available information, desiccant saturation can occur within the first five years in the worst environments, and the time required for full saturation is affected by multiple factors. While no present safety risk has been identified, further work is needed to evaluate the future risk of non-recalled desiccated inflators using propellant 2004.Three entities -- Takata (now known as TK Global), the Independent Testing Coalition, and Exponent -- have been studying the long-term behavior of Takata desiccated PSAN inflators using propellant 2004L (as well as 2004) in the presence of moisture and temperature cycling. The research efforts, which include development of predictive modeling techniques and field sample analysis, are ongoing. To date, none of the researchers have identified field evidence showing that propellant 2004L is undergoing a degradation process that leads to aggressive deployment and potential rupture. However, the time in service of such inflators remains short compared to that of the inflators using propellant 2004. Further study is needed to assess the long-term safety of desiccated inflators using propellant 2004L.The Office of Defects Investigation is opening this investigation to examine whether a safety defect related to propellant degradation exists in non-recalled desiccated PSAN frontal inflators manufactured by Takata. This investigation will require extensive information on Takata production processes and surveys of inflators in the field. Lists of recall actions that may have used desiccated PSAN inflators as remedy parts, as well as the makes and models originally manufactured with them, is available with the downloadable version of this document (see nhtsa.gov/recalls?nhtsaId=EA21002 -- note this information is subject to change/revision as the investigation proceeds). This investigation does not supersede EA15-001, which remains open.

Additional source detail variants (2)

Air Bags:frontal:driver Side:inflator Module

From 2000 through 2017, Takata produced millions of air bag inflators using two types of phase-stabilized ammonium nitrate ("PSAN") propellant -- propellant 2004 and propellant 2004L. After prolonged exposure to high temperature cycles and humidity, inflators using propellant 2004 can degrade, causing the propellant to burn too quickly when ignited. The rapid burning can cause the inflator to rupture during deployment, potentially causing serious or even fatal injury to vehicle occupants. See 2016 Blomquist Report at www.nhtsa.gov/sites/nhtsa.gov/files/documents/expert_report-hrblomquist.pdf.Consequently, all frontal inflators using propellant 2004 that do not contain a "desiccant" (a substance that traps and holds moisture) in US vehicles are under recall. These "non-desiccated" inflators either have been or are required to be replaced.In some cases, the remedy part for these recalled inflators was, or will be, an inflator using either propellant 2004 or 2004L that does contain a desiccant. None of these "desiccated" remedy parts (which were installed in older model year vehicles) are currently under recall for a degradation concern. Certain subsets of desiccated PSAN inflators using propellant 2004 for use as original equipment, however, have been recalled for a degradation concern. All Takata inflators produced with propellant 2004L contain desiccant, and none of these desiccated inflators using propellant 2004L are under recall for a degradation concern. There have been no reported field ruptures in any non-recalled desiccated PSAN inflators.It is understood that desiccants fully saturate at some threshold, at which point any additional moisture will not be captured. This means the degradation process observed in non-desiccated inflators using propellant 2004 may also occur in non-recalled desiccated inflators using propellant 2004, assuming additional moisture enters the inflator and high temperature cycling occurs. Based on available information, desiccant saturation can occur within the first five years in the worst environments, and the time required for full saturation is affected by multiple factors. While no present safety risk has been identified, further work is needed to evaluate the future risk of non-recalled desiccated inflators using propellant 2004.Three entities -- Takata (now known as TK Global), the Independent Testing Coalition, and Exponent -- have been studying the long-term behavior of Takata desiccated PSAN inflators using propellant 2004L (as well as 2004) in the presence of moisture and temperature cycling. The research efforts, which include development of predictive modeling techniques and field sample analysis, are ongoing. To date, none of the researchers have identified field evidence showing that propellant 2004L is undergoing a degradation process that leads to aggressive deployment and potential rupture. However, the time in service of such inflators remains short compared to that of the inflators using propellant 2004. Further study is needed to assess the long-term safety of desiccated inflators using propellant 2004L.The Office of Defects Investigation is opening this investigation to examine whether a safety defect related to propellant degradation exists in non-recalled desiccated PSAN frontal inflators manufactured by Takata. This investigation will require extensive information on Takata production processes and surveys of inflators in the field. Lists of recall actions that may have used desiccated PSAN inflators as remedy parts, as well as the makes and models originally manufactured with them, is available with the downloadable version of this document (see nhtsa.gov/recalls?nhtsaId=EA21002 -- note this information is subject to change/revision as the investigation proceeds). This investigation does not supersede EA15-001, which remains open.

Air Bags:frontal:passenger Side:inflator Module

From 2000 through 2017, Takata produced millions of air bag inflators using two types of phase-stabilized ammonium nitrate ("PSAN") propellant -- propellant 2004 and propellant 2004L. After prolonged exposure to high temperature cycles and humidity, inflators using propellant 2004 can degrade, causing the propellant to burn too quickly when ignited. The rapid burning can cause the inflator to rupture during deployment, potentially causing serious or even fatal injury to vehicle occupants. See 2016 Blomquist Report at www.nhtsa.gov/sites/nhtsa.gov/files/documents/expert_report-hrblomquist.pdf.Consequently, all frontal inflators using propellant 2004 that do not contain a "desiccant" (a substance that traps and holds moisture) in US vehicles are under recall. These "non-desiccated" inflators either have been or are required to be replaced.In some cases, the remedy part for these recalled inflators was, or will be, an inflator using either propellant 2004 or 2004L that does contain a desiccant. None of these "desiccated" remedy parts (which were installed in older model year vehicles) are currently under recall for a degradation concern. Certain subsets of desiccated PSAN inflators using propellant 2004 for use as original equipment, however, have been recalled for a degradation concern. All Takata inflators produced with propellant 2004L contain desiccant, and none of these desiccated inflators using propellant 2004L are under recall for a degradation concern. There have been no reported field ruptures in any non-recalled desiccated PSAN inflators.It is understood that desiccants fully saturate at some threshold, at which point any additional moisture will not be captured. This means the degradation process observed in non-desiccated inflators using propellant 2004 may also occur in non-recalled desiccated inflators using propellant 2004, assuming additional moisture enters the inflator and high temperature cycling occurs. Based on available information, desiccant saturation can occur within the first five years in the worst environments, and the time required for full saturation is affected by multiple factors. While no present safety risk has been identified, further work is needed to evaluate the future risk of non-recalled desiccated inflators using propellant 2004.Three entities -- Takata (now known as TK Global), the Independent Testing Coalition, and Exponent -- have been studying the long-term behavior of Takata desiccated PSAN inflators using propellant 2004L (as well as 2004) in the presence of moisture and temperature cycling. The research efforts, which include development of predictive modeling techniques and field sample analysis, are ongoing. To date, none of the researchers have identified field evidence showing that propellant 2004L is undergoing a degradation process that leads to aggressive deployment and potential rupture. However, the time in service of such inflators remains short compared to that of the inflators using propellant 2004. Further study is needed to assess the long-term safety of desiccated inflators using propellant 2004L.The Office of Defects Investigation is opening this investigation to examine whether a safety defect related to propellant degradation exists in non-recalled desiccated PSAN frontal inflators manufactured by Takata. This investigation will require extensive information on Takata production processes and surveys of inflators in the field. Lists of recall actions that may have used desiccated PSAN inflators as remedy parts, as well as the makes and models originally manufactured with them, is available with the downloadable version of this document (see nhtsa.gov/recalls?nhtsaId=EA21002 -- note this information is subject to change/revision as the investigation proceeds). This investigation does not supersede EA15-001, which remains open.