← New search

2004 Mercedes Benz E500

Owner reports · Recalls · Investigations

More warning signs than most E500 years

Owner complaints for the 2004 Mercedes Benz E500 are substantially higher than the model-year median of 50.

About this comparison →

How this year compares

Owner complaints by model year

Other model years Selected year
Compare all E500 years →

Counts vary with age, sales and reporting. They are not failure rates.

What owners reported most

All reported categories

Tap a category to read its complaints. One report may name several components.

When problems were reported

Mileage at the reported incident

127 reports with mileage · 15 unknown

NHTSA’s mileage field refers to the reported incident, not necessarily the filing date. This shows report counts, not the likelihood of a failure.

What to inspect

Issues worth paying extra attention to based on owner reports.

  • Fuel/propulsion System. Review the 56 owner reports in this category and discuss these concerns during a pre-purchase inspection. Read reports →
  • Fuel System, Gasoline. Review the 30 owner reports in this category and discuss these concerns during a pre-purchase inspection. Read reports →
  • Suspension. Review the 23 owner reports in this category and discuss these concerns during a pre-purchase inspection. Read reports →

NHTSA owner reports · September 18, 2026 snapshot.

3 crash reports2 fire reports2 injury reports

What owners actually said

142 reports
113,000 miles · Aug 15, 2013
Fuel System, Gasoline

AFTER FILLING MY CAR WITH FUEL, I HAVE NOTICE A STRONG ODOR OF GAS FUMES IN MY GARAGE AND INSIDE MY CAR. BUT I DON'T SEE ANY LEAKS ON THE FLOOR. AFTER THE GAS TANK DROPS TO 3/4 OF A TANK, THE SMELL OF FUMES GOES AWAY. THIS HAS BEEN GOING ON FOR SEVERAL MONTHS. ALSO, THE GAS GAUGE ISN'T ACCURATE. I FOUND OUT, THIS IS A TYPICAL P…

Read full complaint

AFTER FILLING MY CAR WITH FUEL, I HAVE NOTICE A STRONG ODOR OF GAS FUMES IN MY GARAGE AND INSIDE MY CAR. BUT I DON'T SEE ANY LEAKS ON THE FLOOR. AFTER THE GAS TANK DROPS TO 3/4 OF A TANK, THE SMELL OF FUMES GOES AWAY. THIS HAS BEEN GOING ON FOR SEVERAL MONTHS. ALSO, THE GAS GAUGE ISN'T ACCURATE. I FOUND OUT, THIS IS A TYPICAL PROBLEM WITH THE E CLASS 2003-2008. I BELIEVE THIS IS A SAFETY ISSUE AND THAT MERCEDES SHOULD REPAIR IT ASAP. THANKS. *TR

NHTSA ODI #10535449

85,000 miles · Aug 9, 2013
Electrical SystemSuspension

WHILE TRAVELING NORTH ON I-5, AT APPROX. 65 MPH, DISPLAY SHOWED RED LETTERING "VEHICLE TOO LOW STOP CAR". MADE MY WAY OVER TO SIDE OF ROAD WHEN MESSAGE DISAPPEARED. PROCEEDED WITH TRIP. AFTER A COUPLE OF MILES, MESSAGE APPEARED AGAIN. NO SIGNIFICANT DIFFERENCE IN CAR HANDLING OR PERFORMANCE FELT. MESSAGE AGAIN, DISAPPEARED. THI…

Read full complaint

WHILE TRAVELING NORTH ON I-5, AT APPROX. 65 MPH, DISPLAY SHOWED RED LETTERING "VEHICLE TOO LOW STOP CAR". MADE MY WAY OVER TO SIDE OF ROAD WHEN MESSAGE DISAPPEARED. PROCEEDED WITH TRIP. AFTER A COUPLE OF MILES, MESSAGE APPEARED AGAIN. NO SIGNIFICANT DIFFERENCE IN CAR HANDLING OR PERFORMANCE FELT. MESSAGE AGAIN, DISAPPEARED. THIS CONTINUED UNTIL ARRIVAL AT HOME. THOUGHT FAULTY RELAY OR SOME ELECTRICAL PROBLEM. ONCE HOME, I GOT OUT OF CAR AND HEARD A SOUND AS IF AIR WAS ESCAPING FROM A BALLOON. NOTICED LEFT FRONT HAD DROPPED ALMOST ON TIRE. CAR NOT DRIVABLE. TOWED TO SHOP. BLADDER BURST. *TR

NHTSA ODI #10534472

126,000 miles · Jul 31, 2013
Fuel/propulsion System

TL* THE CONTACT OWNS A 2004 MERCEDES BENZ E500. THE CONTACT STATED THAT WHILE HAVING THE VEHICLE INSPECTED, THE MECHANIC INFORMED THE CONTACT THAT THE FUEL FILTER MODULE NEEDED TO BE REPLACED. THE VEHICLE WAS NOT REPAIRED AND THE MANUFACTURER WAS NOTIFIED. THE APPROXIMATE FAILURE MILEAGE WAS 126,000.

NHTSA ODI #10532854

115,000 miles · Jul 22, 2013
Fuel/propulsion System

TL* THE CONTACT OWNS A 2004 MERCEDES-BENZ E500. THE CONTACT STATED THAT FUEL WAS SMELLED AROUND THE VEHICLE. THE VEHICLE WAS TAKEN TO THE DEALER WHERE IT WAS FOUND THAT THE FUEL TANK NEEDED TO BE REPLACED. THE VEHICLE WAS NOT REPAIRED. THE MANUFACTURER WAS CONTACTED ABOUT THE FAILURE. THE FAILURE MILEAGE WAS 115,000.

NHTSA ODI #10526109

109,000 miles · Jun 15, 2013
Fuel System, Gasoline

MY VEHICLE 2004 E500 HAS STRONG SMELL OF GAS IN CABIN FROM THE REAR SEAT AREA AND OUTSIDE OF THE CAR, SINCE THEN CAR TAKES LONGER TO TURN ON. HOPE THIS WILL BE SOLVED SOON. *TR

NHTSA ODI #10519902

103,102 miles · Jun 2, 2013
Fuel System, Gasoline

FOR THE PAST SEVERAL MONTHS AFTER FILLING THE VEHICLE A STRONG GAS SMELL/FUMES ARE PRESENT IN THE VEHICLE. THE SMELL/FUMES SUBSIDE WHEN APPROXIMATELY 1/4 OF THE FUEL IN THE TANK HAS BEEN USED. ON FRIDAY MAY 31ST 2013 THE VEHICLE WAS FILLED WITH FUEL. PARKED THE VEHICLE IN THE GARAGE FRIDAY NIGHT AND WAS KNOCKED OVER BY GAS SM…

Read full complaint

FOR THE PAST SEVERAL MONTHS AFTER FILLING THE VEHICLE A STRONG GAS SMELL/FUMES ARE PRESENT IN THE VEHICLE. THE SMELL/FUMES SUBSIDE WHEN APPROXIMATELY 1/4 OF THE FUEL IN THE TANK HAS BEEN USED. ON FRIDAY MAY 31ST 2013 THE VEHICLE WAS FILLED WITH FUEL. PARKED THE VEHICLE IN THE GARAGE FRIDAY NIGHT AND WAS KNOCKED OVER BY GAS SMELL/FUMES ON SATURDAY MORNING, JUNE 1ST 2013. THE VEHICLE WAS PARKED OUTSIDE OVERNIGHT. AFTER RESEARCHING THE ISSUE, I FOUND FUEL AROUND THE SENDING UNIT UNDER THE DRIVE SIDE BACK SEAT. THE FUEL WAS REMOVED AND THE SENDING UNIT CLEANED. THE SENDING UNIT WAS OBSERVED SEE IF A LEAK COULD BE DETECTED ON THE UNIT. THE LEAK IS AT THE TOP PART OF THE SENDING UNIT. THE PART WHERE THE SMALL WIRE PLUG IS ATTACHED TO THE SENDING UNIT. IT LOOKS LIKE THIS PART IS "GLUED" TO THE BODY OF THE SENDING UNIT. SHORT TERM FIX IS TO ONLY FILL THE FUEL TANK HALF WAY. THIS HAZARD, IF NOT RECTIFIED BY THE MANUFACTURE MAKES MINE AND ALL OTHER VEHICLES UNSAFE AND UN-SELLABLE ON THE USED CAR MARKET.

NHTSA ODI #10515250

9,000 miles · May 31, 2013
Fuel System, Gasoline

TL* THE CONTACT OWNS A 2004 MERCEDES BENZ E500. THE CONTACT STATED THAT AFTER REFUELING, THERE WERE GASOLINE FUMES PRESENT IN THE INTERIOR AND EXTERIOR OF THE VEHICLE. THE VEHICLE WAS TAKEN TO THE DEALER AND THE MANUFACTURER WAS MADE AWARE OF THE FAILURE. THE VEHICLE WAS NOT REPAIRED. THE FAILURE MILEAGE WAS 9,000 AND THE CURREN…

Read full complaint

TL* THE CONTACT OWNS A 2004 MERCEDES BENZ E500. THE CONTACT STATED THAT AFTER REFUELING, THERE WERE GASOLINE FUMES PRESENT IN THE INTERIOR AND EXTERIOR OF THE VEHICLE. THE VEHICLE WAS TAKEN TO THE DEALER AND THE MANUFACTURER WAS MADE AWARE OF THE FAILURE. THE VEHICLE WAS NOT REPAIRED. THE FAILURE MILEAGE WAS 9,000 AND THE CURRENT MILEAGE WAS 93,000. *TR

NHTSA ODI #10514431

68,000 miles · May 18, 2013
Fuel System, GasolineFuel/propulsion System

REFERENCE NHTSA ACTION NUMBER: PE12001. THERE IS A DISTINCT FUEL SMELL AFTER FILLING UP THE TANK. DO NOT SMELL INSIDE VEHICLE BUT DO SMELL AFTER THE CAR IS PUT AWAY INSIDE GARAGE. NO SIGN OF LEAKAGE UNDER THE CAR (PUDDLING OR DRIPS). GOES AWAY AFTER FUEL TANK IS LESS THAN FULL. THERE IS NO SMELL IF YOU ONLY FILL TO 3/4. *TR

NHTSA ODI #10512625

Mileage unknown · Apr 11, 2013
Fuel/propulsion System

THE FUEL TANK CANNOT BE FILLED UP COMPLETELY. DOING SO CAUSES THE CAR TO SMELL LIKE GASOLINE. THERE SEEMS TO BE A FUEL LEAK ON THE TANK WHICH CAUSES THE GASOLINE TO SPILL. THE ODOR COMES MOSTLY FROM THE BACK SEAT OF THE CAR. IF THE TANK IS FILLED, THE CAR WILL HAVE THE GASOLINE ODOR FOR WEEKS EVEN WITH THE WINDOWS LEFT OPEN.…

Read full complaint

THE FUEL TANK CANNOT BE FILLED UP COMPLETELY. DOING SO CAUSES THE CAR TO SMELL LIKE GASOLINE. THERE SEEMS TO BE A FUEL LEAK ON THE TANK WHICH CAUSES THE GASOLINE TO SPILL. THE ODOR COMES MOSTLY FROM THE BACK SEAT OF THE CAR. IF THE TANK IS FILLED, THE CAR WILL HAVE THE GASOLINE ODOR FOR WEEKS EVEN WITH THE WINDOWS LEFT OPEN. THIS IS QUITE DANGEROUS IN MANY WAYS SINCE I HAVE AN INFANT WHO IS REQUIRED BY LAW TO SIT IN THE BACKSEAT REAR FACED. *TR

NHTSA ODI #10505966

160,000 miles · Apr 10, 2013
Fuel/propulsion System

THERE WAS A FUEL LEAK THAT CAUSED THE CAR TO SMELL OF GAS WHEN THE TANK IS NEAR FULL (3/4) TO COMPLETELY FILLED. THE FUEL HAS NOT BEEN LEAKING TO THE GROUND AND I HAVE BEEN UNABLE TO PINPOINT EXACT LOCATION. WHEN I WOULD GO INTO MY CLOSED GARAGE AFTER THE CAR HAD BEEN PARKED FOR A WHILE THE SMELL OF FUEL IS TOO STRONG TO IGNORE.…

Read full complaint

THERE WAS A FUEL LEAK THAT CAUSED THE CAR TO SMELL OF GAS WHEN THE TANK IS NEAR FULL (3/4) TO COMPLETELY FILLED. THE FUEL HAS NOT BEEN LEAKING TO THE GROUND AND I HAVE BEEN UNABLE TO PINPOINT EXACT LOCATION. WHEN I WOULD GO INTO MY CLOSED GARAGE AFTER THE CAR HAD BEEN PARKED FOR A WHILE THE SMELL OF FUEL IS TOO STRONG TO IGNORE. MY MECHANIC TOLD ME THE SOURCE IS THE SENDING UNIT AND TANK ASSEMBLY. HE TOLD ME THE FAILURE WAS COMMON AND THE SITUATION COULD BECOME VERY DANGEROUS IF IGNORED. THE COST TO REPLACE THE TANK IS GOING TO RUN $2,000. THE CAR HAS NEVER BEEN DAMAGED AND SHOULD NOT REQUIRE A TANK REPLACEMENT AT THIS POINT IN ITS LIFECYCLE. *TR

NHTSA ODI #10505741

Official recalls

3

24V874000 · Visibility:sun/moon Roof Assembly

Nov 19, 2024

Mercedes-Benz USA, LLC (MBUSA) is recalling certain 2001-2011 C-Class, CLK, E-Class, and CLS vehicles. Please see the recall report for a complete list of models and model years. The glass sunroof panel may not be properly secured and can detach.

Consequence & remedy

Consequence: A detached sunroof panel can become a road hazard, increasing the risk of a crash.

Remedy: Dealers will inspect and replace the sunroof panel as necessary, free of charge. Owner notification letters were mailed January 10, 2025. Owners may contact MBUSA customer service at 1-800-367-6372. This recall is an expansion of previous NHTSA recall number 22V-954. MBUSA's number for this recall is 2024120001/2/3.

22V954000 · Visibility:sun/moon Roof Assembly

Dec 23, 2022

Mercedes-Benz USA, LLC (MBUSA) is recalling certain 2001-2011 C-Class, CLK, E-Class, and CLS vehicles. Please refer to MBUSA's recall report for specific vehicle model details. The glass sunroof panel may not be properly secured and may detach.

Consequence & remedy

Consequence: A detached sunroof panel may become a road hazard, increasing the risk of a crash.

Remedy: Dealers will inspect and replace the sunroof panel as necessary free of charge. Owner notification letters were mailed February 3, 2023. Owners may contact MBUSA customer service at 1-800-367-6372. This recall expands NHTSA recall number 19V-918. MBUSA's numbers for this recall are 2023010004, 2023010005, and 2023010006.

19V918000 · Visibility:sun/moon Roof Assembly

Dec 20, 2019

Mercedes-Benz USA, LLC. (MBUSA) is recalling certain 2001-2011 vehicles. The bonding between the glass panel and the sliding roof frame may deteriorate, possibly resulting in the glass panel detaching from the vehicle. For a full list of the affected models visit: https://static.nhtsa.gov/odi/rcl/2019/RMISC-19V918-4126.pdf

Consequence & remedy

Consequence: A detached glass panel can separate from the vehicle and become a road hazard, increasing the risk of a crash.

Remedy: MBUSA will notify owners, and dealers will inspect the glass panel bonding and replace the sliding roof, as necessary, free of charge. The recall began July 10, 2020. Owners may contact MBUSA customer service at 1-800-367-6372. MBUSA's number for this recall is 2020040011.

Model-level recall history does not show whether a particular VIN is affected or has received a repair. Check a VIN with NHTSA ↗

NHTSA investigations

1

EA13003 · Fuel Leakage From The Fuel Tank

Opened Mar 15, 2013 · Closed Dec 19, 2014

Status: closed (inferred from source dates) · Fuel System, Gasoline; Fuel System, Gasoline:delivery; Fuel System, Gasoline:delivery:fuel Pump; Fuel System, Gasoline:delivery:hoses, Lines/piping, And Fittings; Fuel System, Gasoline:storage; Fuel System, Gasoline:storage:tank Assembly

The Office of Defects Investigation (ODI) opened this investigation on January 23, 2012 as PE12-001 based on 20 consumer reports in model year (MY) 2003-2006 E55 AMG vehicles.Based on new reports in other E-Class vehicles, ODI upgraded the investigation to Engineering Analysis (EA) 13-003 on March 15, 2013, and expanded the scope to all E-Class vehicles through MY 2008.The complainants alleged a strong odor of gasoline fuel both inside and outside of their vehicle, particularly after refilling the fuel tank.Many of the complainants noted that the odor subsided or went away after driving some distance thereby lowering the fuel level in the tank.Other owners reported they would only fill the tank to about three quarters full to avoid the odor altogether.Some complainants alleged fuel leaked from the fuel filter/sender, located on the top of the fuel tank on the driver's side, and collected on top of the tank.There were also allegations that the fuel leaks were associated with an Emissions Recall Campaign (No. 2008020001) conducted by Mercedes-Benz USA, LLC (Mercedes) in 2008 on MY 2003-2006 E-Class and CLS-Class AMG models.The issue in the recall involved small cracks in the pressurized outlet fitting of the fuel filter/sender.AMG vehicles are high performance models that operate at higher fuel pressure and use a different fuel filter/sender and fuel pump than non-AMG models.Information on Recall No. 2008020001 is available from the U.S. Environmental Protection Agency (EPA) website at www.EPA.gov.ODI's investigation found various leak sources that are unrelated to the outlet fitting cited in the EPA recall campaign.Through interviews with complainants, field inspections of complaint vehicles, and the collection and laboratory analysis of failed parts, three identifiable leak sources were found.The component parts and areas of the leaks involve the On-Board Diagnostic fuel tank pressure sensor (located on top of the fuel filter/sender), the outlet of the centrally mounted fuel tank fuel filling limiter valve, and the top of the fuel pump. These areas of leakage are located at the top of the fuel tank in unpressurized parts of the fuel system. When the tank is full, fuel can slowly weep/seep from micro-cracks in these components and may collect in cavities on top of the filter/sender, pump, or tank.Contrary to complainant's allegations that fuel entered the inside of their vehicle under the rear seat bench, neither ODI nor Mercedes found a plausible way for this to occur.The fuel tank is located outside of the passenger compartment, attached to the underside of the vehicle.The service access ports for the fuel filter/sender (driver's side) and fuel pump (passenger's side) are located under the rear seat bench, covered by a steel plate, sealed and bolted to the vehicle floor.When technicians service the fuel filter/sender, which has a regularly scheduled 60,000 mile service interval, and/or the fuel pump, the work is performed from inside the vehicle by working through the access ports.By letter dated September 4, 2014, Mercedes has notified the agency that it will extend the original warranty coverage to 15 years and unlimited mileage on Covered Fuel Tank Components in E-Class vehicles in MY 2003-2009 and CLS-Class vehicles in MY 2006-2011.The covered fuel tank components for the warranty extension include the fuel tank, fuel filter/sender, fuel pump, and all related gaskets/seals and retention rings.ODI is closing this investigation based on the manufacturer's extend warranty of the affected fuel system components and in consideration that the nature of the leaks does not appear to present an un

Additional source detail variants (6)

Fuel System, Gasoline:delivery:fuel Pump

The Office of Defects Investigation (ODI) opened this investigation on January 23, 2012 as PE12-001 based on 20 consumer reports in model year (MY) 2003-2006 E55 AMG vehicles.Based on new reports in other E-Class vehicles, ODI upgraded the investigation to Engineering Analysis (EA) 13-003 on March 15, 2013, and expanded the scope to all E-Class vehicles through MY 2008.The complainants alleged a strong odor of gasoline fuel both inside and outside of their vehicle, particularly after refilling the fuel tank.Many of the complainants noted that the odor subsided or went away after driving some distance thereby lowering the fuel level in the tank.Other owners reported they would only fill the tank to about three quarters full to avoid the odor altogether.Some complainants alleged fuel leaked from the fuel filter/sender, located on the top of the fuel tank on the driver's side, and collected on top of the tank.There were also allegations that the fuel leaks were associated with an Emissions Recall Campaign (No. 2008020001) conducted by Mercedes-Benz USA, LLC (Mercedes) in 2008 on MY 2003-2006 E-Class and CLS-Class AMG models.The issue in the recall involved small cracks in the pressurized outlet fitting of the fuel filter/sender.AMG vehicles are high performance models that operate at higher fuel pressure and use a different fuel filter/sender and fuel pump than non-AMG models.Information on Recall No. 2008020001 is available from the U.S. Environmental Protection Agency (EPA) website at www.EPA.gov.ODI's investigation found various leak sources that are unrelated to the outlet fitting cited in the EPA recall campaign.Through interviews with complainants, field inspections of complaint vehicles, and the collection and laboratory analysis of failed parts, three identifiable leak sources were found.The component parts and areas of the leaks involve the On-Board Diagnostic fuel tank pressure sensor (located on top of the fuel filter/sender), the outlet of the centrally mounted fuel tank fuel filling limiter valve, and the top of the fuel pump. These areas of leakage are located at the top of the fuel tank in unpressurized parts of the fuel system. When the tank is full, fuel can slowly weep/seep from micro-cracks in these components and may collect in cavities on top of the filter/sender, pump, or tank.Contrary to complainant's allegations that fuel entered the inside of their vehicle under the rear seat bench, neither ODI nor Mercedes found a plausible way for this to occur.The fuel tank is located outside of the passenger compartment, attached to the underside of the vehicle.The service access ports for the fuel filter/sender (driver's side) and fuel pump (passenger's side) are located under the rear seat bench, covered by a steel plate, sealed and bolted to the vehicle floor.When technicians service the fuel filter/sender, which has a regularly scheduled 60,000 mile service interval, and/or the fuel pump, the work is performed from inside the vehicle by working through the access ports.By letter dated September 4, 2014, Mercedes has notified the agency that it will extend the original warranty coverage to 15 years and unlimited mileage on Covered Fuel Tank Components in E-Class vehicles in MY 2003-2009 and CLS-Class vehicles in MY 2006-2011.The covered fuel tank components for the warranty extension include the fuel tank, fuel filter/sender, fuel pump, and all related gaskets/seals and retention rings.ODI is closing this investigation based on the manufacturer's extend warranty of the affected fuel system components and in consideration that the nature of the leaks does not appear to present an un

Fuel System, Gasoline:delivery:hoses, Lines/piping, And Fittings

The Office of Defects Investigation (ODI) opened this investigation on January 23, 2012 as PE12-001 based on 20 consumer reports in model year (MY) 2003-2006 E55 AMG vehicles.Based on new reports in other E-Class vehicles, ODI upgraded the investigation to Engineering Analysis (EA) 13-003 on March 15, 2013, and expanded the scope to all E-Class vehicles through MY 2008.The complainants alleged a strong odor of gasoline fuel both inside and outside of their vehicle, particularly after refilling the fuel tank.Many of the complainants noted that the odor subsided or went away after driving some distance thereby lowering the fuel level in the tank.Other owners reported they would only fill the tank to about three quarters full to avoid the odor altogether.Some complainants alleged fuel leaked from the fuel filter/sender, located on the top of the fuel tank on the driver's side, and collected on top of the tank.There were also allegations that the fuel leaks were associated with an Emissions Recall Campaign (No. 2008020001) conducted by Mercedes-Benz USA, LLC (Mercedes) in 2008 on MY 2003-2006 E-Class and CLS-Class AMG models.The issue in the recall involved small cracks in the pressurized outlet fitting of the fuel filter/sender.AMG vehicles are high performance models that operate at higher fuel pressure and use a different fuel filter/sender and fuel pump than non-AMG models.Information on Recall No. 2008020001 is available from the U.S. Environmental Protection Agency (EPA) website at www.EPA.gov.ODI's investigation found various leak sources that are unrelated to the outlet fitting cited in the EPA recall campaign.Through interviews with complainants, field inspections of complaint vehicles, and the collection and laboratory analysis of failed parts, three identifiable leak sources were found.The component parts and areas of the leaks involve the On-Board Diagnostic fuel tank pressure sensor (located on top of the fuel filter/sender), the outlet of the centrally mounted fuel tank fuel filling limiter valve, and the top of the fuel pump. These areas of leakage are located at the top of the fuel tank in unpressurized parts of the fuel system. When the tank is full, fuel can slowly weep/seep from micro-cracks in these components and may collect in cavities on top of the filter/sender, pump, or tank.Contrary to complainant's allegations that fuel entered the inside of their vehicle under the rear seat bench, neither ODI nor Mercedes found a plausible way for this to occur.The fuel tank is located outside of the passenger compartment, attached to the underside of the vehicle.The service access ports for the fuel filter/sender (driver's side) and fuel pump (passenger's side) are located under the rear seat bench, covered by a steel plate, sealed and bolted to the vehicle floor.When technicians service the fuel filter/sender, which has a regularly scheduled 60,000 mile service interval, and/or the fuel pump, the work is performed from inside the vehicle by working through the access ports.By letter dated September 4, 2014, Mercedes has notified the agency that it will extend the original warranty coverage to 15 years and unlimited mileage on Covered Fuel Tank Components in E-Class vehicles in MY 2003-2009 and CLS-Class vehicles in MY 2006-2011.The covered fuel tank components for the warranty extension include the fuel tank, fuel filter/sender, fuel pump, and all related gaskets/seals and retention rings.ODI is closing this investigation based on the manufacturer's extend warranty of the affected fuel system components and in consideration that the nature of the leaks does not appear to present an un

Fuel System, Gasoline:delivery

The Office of Defects Investigation (ODI) opened this investigation on January 23, 2012 as PE12-001 based on 20 consumer reports in model year (MY) 2003-2006 E55 AMG vehicles.Based on new reports in other E-Class vehicles, ODI upgraded the investigation to Engineering Analysis (EA) 13-003 on March 15, 2013, and expanded the scope to all E-Class vehicles through MY 2008.The complainants alleged a strong odor of gasoline fuel both inside and outside of their vehicle, particularly after refilling the fuel tank.Many of the complainants noted that the odor subsided or went away after driving some distance thereby lowering the fuel level in the tank.Other owners reported they would only fill the tank to about three quarters full to avoid the odor altogether.Some complainants alleged fuel leaked from the fuel filter/sender, located on the top of the fuel tank on the driver's side, and collected on top of the tank.There were also allegations that the fuel leaks were associated with an Emissions Recall Campaign (No. 2008020001) conducted by Mercedes-Benz USA, LLC (Mercedes) in 2008 on MY 2003-2006 E-Class and CLS-Class AMG models.The issue in the recall involved small cracks in the pressurized outlet fitting of the fuel filter/sender.AMG vehicles are high performance models that operate at higher fuel pressure and use a different fuel filter/sender and fuel pump than non-AMG models.Information on Recall No. 2008020001 is available from the U.S. Environmental Protection Agency (EPA) website at www.EPA.gov.ODI's investigation found various leak sources that are unrelated to the outlet fitting cited in the EPA recall campaign.Through interviews with complainants, field inspections of complaint vehicles, and the collection and laboratory analysis of failed parts, three identifiable leak sources were found.The component parts and areas of the leaks involve the On-Board Diagnostic fuel tank pressure sensor (located on top of the fuel filter/sender), the outlet of the centrally mounted fuel tank fuel filling limiter valve, and the top of the fuel pump. These areas of leakage are located at the top of the fuel tank in unpressurized parts of the fuel system. When the tank is full, fuel can slowly weep/seep from micro-cracks in these components and may collect in cavities on top of the filter/sender, pump, or tank.Contrary to complainant's allegations that fuel entered the inside of their vehicle under the rear seat bench, neither ODI nor Mercedes found a plausible way for this to occur.The fuel tank is located outside of the passenger compartment, attached to the underside of the vehicle.The service access ports for the fuel filter/sender (driver's side) and fuel pump (passenger's side) are located under the rear seat bench, covered by a steel plate, sealed and bolted to the vehicle floor.When technicians service the fuel filter/sender, which has a regularly scheduled 60,000 mile service interval, and/or the fuel pump, the work is performed from inside the vehicle by working through the access ports.By letter dated September 4, 2014, Mercedes has notified the agency that it will extend the original warranty coverage to 15 years and unlimited mileage on Covered Fuel Tank Components in E-Class vehicles in MY 2003-2009 and CLS-Class vehicles in MY 2006-2011.The covered fuel tank components for the warranty extension include the fuel tank, fuel filter/sender, fuel pump, and all related gaskets/seals and retention rings.ODI is closing this investigation based on the manufacturer's extend warranty of the affected fuel system components and in consideration that the nature of the leaks does not appear to present an un

Fuel System, Gasoline

The Office of Defects Investigation (ODI) opened this investigation on January 23, 2012 as PE12-001 based on 20 consumer reports in model year (MY) 2003-2006 E55 AMG vehicles.Based on new reports in other E-Class vehicles, ODI upgraded the investigation to Engineering Analysis (EA) 13-003 on March 15, 2013, and expanded the scope to all E-Class vehicles through MY 2008.The complainants alleged a strong odor of gasoline fuel both inside and outside of their vehicle, particularly after refilling the fuel tank.Many of the complainants noted that the odor subsided or went away after driving some distance thereby lowering the fuel level in the tank.Other owners reported they would only fill the tank to about three quarters full to avoid the odor altogether.Some complainants alleged fuel leaked from the fuel filter/sender, located on the top of the fuel tank on the driver's side, and collected on top of the tank.There were also allegations that the fuel leaks were associated with an Emissions Recall Campaign (No. 2008020001) conducted by Mercedes-Benz USA, LLC (Mercedes) in 2008 on MY 2003-2006 E-Class and CLS-Class AMG models.The issue in the recall involved small cracks in the pressurized outlet fitting of the fuel filter/sender.AMG vehicles are high performance models that operate at higher fuel pressure and use a different fuel filter/sender and fuel pump than non-AMG models.Information on Recall No. 2008020001 is available from the U.S. Environmental Protection Agency (EPA) website at www.EPA.gov.ODI's investigation found various leak sources that are unrelated to the outlet fitting cited in the EPA recall campaign.Through interviews with complainants, field inspections of complaint vehicles, and the collection and laboratory analysis of failed parts, three identifiable leak sources were found.The component parts and areas of the leaks involve the On-Board Diagnostic fuel tank pressure sensor (located on top of the fuel filter/sender), the outlet of the centrally mounted fuel tank fuel filling limiter valve, and the top of the fuel pump. These areas of leakage are located at the top of the fuel tank in unpressurized parts of the fuel system. When the tank is full, fuel can slowly weep/seep from micro-cracks in these components and may collect in cavities on top of the filter/sender, pump, or tank.Contrary to complainant's allegations that fuel entered the inside of their vehicle under the rear seat bench, neither ODI nor Mercedes found a plausible way for this to occur.The fuel tank is located outside of the passenger compartment, attached to the underside of the vehicle.The service access ports for the fuel filter/sender (driver's side) and fuel pump (passenger's side) are located under the rear seat bench, covered by a steel plate, sealed and bolted to the vehicle floor.When technicians service the fuel filter/sender, which has a regularly scheduled 60,000 mile service interval, and/or the fuel pump, the work is performed from inside the vehicle by working through the access ports.By letter dated September 4, 2014, Mercedes has notified the agency that it will extend the original warranty coverage to 15 years and unlimited mileage on Covered Fuel Tank Components in E-Class vehicles in MY 2003-2009 and CLS-Class vehicles in MY 2006-2011.The covered fuel tank components for the warranty extension include the fuel tank, fuel filter/sender, fuel pump, and all related gaskets/seals and retention rings.ODI is closing this investigation based on the manufacturer's extend warranty of the affected fuel system components and in consideration that the nature of the leaks does not appear to present an un

Fuel System, Gasoline:storage

The Office of Defects Investigation (ODI) opened this investigation on January 23, 2012 as PE12-001 based on 20 consumer reports in model year (MY) 2003-2006 E55 AMG vehicles.Based on new reports in other E-Class vehicles, ODI upgraded the investigation to Engineering Analysis (EA) 13-003 on March 15, 2013, and expanded the scope to all E-Class vehicles through MY 2008.The complainants alleged a strong odor of gasoline fuel both inside and outside of their vehicle, particularly after refilling the fuel tank.Many of the complainants noted that the odor subsided or went away after driving some distance thereby lowering the fuel level in the tank.Other owners reported they would only fill the tank to about three quarters full to avoid the odor altogether.Some complainants alleged fuel leaked from the fuel filter/sender, located on the top of the fuel tank on the driver's side, and collected on top of the tank.There were also allegations that the fuel leaks were associated with an Emissions Recall Campaign (No. 2008020001) conducted by Mercedes-Benz USA, LLC (Mercedes) in 2008 on MY 2003-2006 E-Class and CLS-Class AMG models.The issue in the recall involved small cracks in the pressurized outlet fitting of the fuel filter/sender.AMG vehicles are high performance models that operate at higher fuel pressure and use a different fuel filter/sender and fuel pump than non-AMG models.Information on Recall No. 2008020001 is available from the U.S. Environmental Protection Agency (EPA) website at www.EPA.gov.ODI's investigation found various leak sources that are unrelated to the outlet fitting cited in the EPA recall campaign.Through interviews with complainants, field inspections of complaint vehicles, and the collection and laboratory analysis of failed parts, three identifiable leak sources were found.The component parts and areas of the leaks involve the On-Board Diagnostic fuel tank pressure sensor (located on top of the fuel filter/sender), the outlet of the centrally mounted fuel tank fuel filling limiter valve, and the top of the fuel pump. These areas of leakage are located at the top of the fuel tank in unpressurized parts of the fuel system. When the tank is full, fuel can slowly weep/seep from micro-cracks in these components and may collect in cavities on top of the filter/sender, pump, or tank.Contrary to complainant's allegations that fuel entered the inside of their vehicle under the rear seat bench, neither ODI nor Mercedes found a plausible way for this to occur.The fuel tank is located outside of the passenger compartment, attached to the underside of the vehicle.The service access ports for the fuel filter/sender (driver's side) and fuel pump (passenger's side) are located under the rear seat bench, covered by a steel plate, sealed and bolted to the vehicle floor.When technicians service the fuel filter/sender, which has a regularly scheduled 60,000 mile service interval, and/or the fuel pump, the work is performed from inside the vehicle by working through the access ports.By letter dated September 4, 2014, Mercedes has notified the agency that it will extend the original warranty coverage to 15 years and unlimited mileage on Covered Fuel Tank Components in E-Class vehicles in MY 2003-2009 and CLS-Class vehicles in MY 2006-2011.The covered fuel tank components for the warranty extension include the fuel tank, fuel filter/sender, fuel pump, and all related gaskets/seals and retention rings.ODI is closing this investigation based on the manufacturer's extend warranty of the affected fuel system components and in consideration that the nature of the leaks does not appear to present an un

Fuel System, Gasoline:storage:tank Assembly

The Office of Defects Investigation (ODI) opened this investigation on January 23, 2012 as PE12-001 based on 20 consumer reports in model year (MY) 2003-2006 E55 AMG vehicles.Based on new reports in other E-Class vehicles, ODI upgraded the investigation to Engineering Analysis (EA) 13-003 on March 15, 2013, and expanded the scope to all E-Class vehicles through MY 2008.The complainants alleged a strong odor of gasoline fuel both inside and outside of their vehicle, particularly after refilling the fuel tank.Many of the complainants noted that the odor subsided or went away after driving some distance thereby lowering the fuel level in the tank.Other owners reported they would only fill the tank to about three quarters full to avoid the odor altogether.Some complainants alleged fuel leaked from the fuel filter/sender, located on the top of the fuel tank on the driver's side, and collected on top of the tank.There were also allegations that the fuel leaks were associated with an Emissions Recall Campaign (No. 2008020001) conducted by Mercedes-Benz USA, LLC (Mercedes) in 2008 on MY 2003-2006 E-Class and CLS-Class AMG models.The issue in the recall involved small cracks in the pressurized outlet fitting of the fuel filter/sender.AMG vehicles are high performance models that operate at higher fuel pressure and use a different fuel filter/sender and fuel pump than non-AMG models.Information on Recall No. 2008020001 is available from the U.S. Environmental Protection Agency (EPA) website at www.EPA.gov.ODI's investigation found various leak sources that are unrelated to the outlet fitting cited in the EPA recall campaign.Through interviews with complainants, field inspections of complaint vehicles, and the collection and laboratory analysis of failed parts, three identifiable leak sources were found.The component parts and areas of the leaks involve the On-Board Diagnostic fuel tank pressure sensor (located on top of the fuel filter/sender), the outlet of the centrally mounted fuel tank fuel filling limiter valve, and the top of the fuel pump. These areas of leakage are located at the top of the fuel tank in unpressurized parts of the fuel system. When the tank is full, fuel can slowly weep/seep from micro-cracks in these components and may collect in cavities on top of the filter/sender, pump, or tank.Contrary to complainant's allegations that fuel entered the inside of their vehicle under the rear seat bench, neither ODI nor Mercedes found a plausible way for this to occur.The fuel tank is located outside of the passenger compartment, attached to the underside of the vehicle.The service access ports for the fuel filter/sender (driver's side) and fuel pump (passenger's side) are located under the rear seat bench, covered by a steel plate, sealed and bolted to the vehicle floor.When technicians service the fuel filter/sender, which has a regularly scheduled 60,000 mile service interval, and/or the fuel pump, the work is performed from inside the vehicle by working through the access ports.By letter dated September 4, 2014, Mercedes has notified the agency that it will extend the original warranty coverage to 15 years and unlimited mileage on Covered Fuel Tank Components in E-Class vehicles in MY 2003-2009 and CLS-Class vehicles in MY 2006-2011.The covered fuel tank components for the warranty extension include the fuel tank, fuel filter/sender, fuel pump, and all related gaskets/seals and retention rings.ODI is closing this investigation based on the manufacturer's extend warranty of the affected fuel system components and in consideration that the nature of the leaks does not appear to present an un