← New search

2003 Mercedes Benz E500

Owner reports · Recalls · Investigations

More warning signs than most E500 years

Owner complaints for the 2003 Mercedes Benz E500 are substantially higher than the model-year median of 50.

About this comparison →

How this year compares

Owner complaints by model year

Other model years Selected year
Compare all E500 years →

Counts vary with age, sales and reporting. They are not failure rates.

What owners reported most

All reported categories

Tap a category to read its complaints. One report may name several components.

When problems were reported

Mileage at the reported incident

101 reports with mileage · 24 unknown

NHTSA’s mileage field refers to the reported incident, not necessarily the filing date. This shows report counts, not the likelihood of a failure.

What to inspect

Issues worth paying extra attention to based on owner reports.

  • Service Brakes. Review the 29 owner reports in this category and discuss these concerns during a pre-purchase inspection. Read reports →
  • Fuel/propulsion System. Review the 27 owner reports in this category and discuss these concerns during a pre-purchase inspection. Read reports →
  • Suspension. Review the 19 owner reports in this category and discuss these concerns during a pre-purchase inspection. Read reports →

NHTSA owner reports · September 18, 2026 snapshot.

4 crash reports0 fire reports5 injury reports

What owners actually said

125 reports
83,000 miles · Jun 9, 2012
Fuel/propulsion System

REFERENCE NHTSA ACTION NUMBER: PE12001. FUEL SENDING UNIT LEAKING FUEL RESULTING IN FUEL POOL ON TOP OF FUEL TANK AND UNDER REAR SEAT DRIVERS SIDE. STRONG FUEL SMELL INSIDE VEHICLE WITH BUILT UP OF FUEL VAPORS CAUSING EYE NOSE AND THROAT IRRITATION-ESPECIALLY STRONG SMELL AND VAPOR BUILT UP WHEN FUEL TANK IS FULL OR NEAR FULL. F…

Read full complaint

REFERENCE NHTSA ACTION NUMBER: PE12001. FUEL SENDING UNIT LEAKING FUEL RESULTING IN FUEL POOL ON TOP OF FUEL TANK AND UNDER REAR SEAT DRIVERS SIDE. STRONG FUEL SMELL INSIDE VEHICLE WITH BUILT UP OF FUEL VAPORS CAUSING EYE NOSE AND THROAT IRRITATION-ESPECIALLY STRONG SMELL AND VAPOR BUILT UP WHEN FUEL TANK IS FULL OR NEAR FULL. FULL SPLASHING ON TOP OF TANK AND NEARBY AREA DRIPPING TO FLOOR-FIRE AND EXPLOSIVE HAZARD, CONDITION HAS WORSENED OVER TIME. *JS

NHTSA ODI #10461100

90,000 miles · Jun 8, 2012
Fuel/propulsion System

REFERENCE TO NHTSA ACTION NUMBER: PE12001. THE SEAL ON MY FUEL SENDING UNIT BEGAN LEAKING. THERE HAS BEEN NO ACCIDENTS WITH THIS VEHICLE, AND THIS IS A NON-STRESSED ITEM. THE SEAL THAT ISOLATES FUEL IN THE TANK FROM THE PASSENGER COMPARTMENT HAS FAILED. GASOLINE LEAKS AROUND THE SENDING UNIT SEAL AROUND THE ELECTRICAL CO…

Read full complaint

REFERENCE TO NHTSA ACTION NUMBER: PE12001. THE SEAL ON MY FUEL SENDING UNIT BEGAN LEAKING. THERE HAS BEEN NO ACCIDENTS WITH THIS VEHICLE, AND THIS IS A NON-STRESSED ITEM. THE SEAL THAT ISOLATES FUEL IN THE TANK FROM THE PASSENGER COMPARTMENT HAS FAILED. GASOLINE LEAKS AROUND THE SENDING UNIT SEAL AROUND THE ELECTRICAL CONNECTIONS CONNECTED TO THE SENDING UNIT. THIS LEAK ALLOWS FUEL TO LEAK FROM THE FUEL TANK INTO THE PASSENGER COMPARTMENT DUE TO FAILURE OF THE SEAL WITH NO INPUT OR OUTSIDE ACTION. AFTER FUELING, A FUEL SMELL AND FUMES CAN BE SMELT IN THE CABIN. WHEN THE ACCESS PANEL IS OPENED BELOW THE REAR SEAT, POOLING FUEL CAN BE SEEN. THIS FUEL HAS DIRECT ACCESS TO THE PASSENGER COMPARTMENT. *JS

NHTSA ODI #10460985

Mileage unknown · May 23, 2012
Fuel/propulsion System

AFTER FILLING UP GAS TANK GAS STARTED TO DRIP FROM THE GAS TANK TO THE FLOOR. *TT

NHTSA ODI #10459332

93,000 miles · May 11, 2012
Air Bags

SRS LIGHT INDICATES MALFUNCTION. LIGHT COMES AND GOES AND APPEARS TO BE RANDOM. *TR

NHTSA ODI #10458166

90,600 miles · Feb 21, 2012
Air BagsInjury

TL* THE CONTACT OWNS A 2003 MERCEDES BENZ E500. THE CONTACT WAS DRIVING 40 MPH WHEN THE DRIVER'S SIDE FRONT AND REAR AIR BAGS DEPLOYED WITHOUT WARNING. THE VEHICLE WAS NOT TAKEN TO THE DEALER AND THE MANUFACTURER WAS NOT CONTACTED. THE VEHICLE WAS NOT REPAIRED. THE FAILURE MILEAGE WAS 90,600 AND THE CURRENT MILEAGE WAS 90,683.…

Read full complaint

TL* THE CONTACT OWNS A 2003 MERCEDES BENZ E500. THE CONTACT WAS DRIVING 40 MPH WHEN THE DRIVER'S SIDE FRONT AND REAR AIR BAGS DEPLOYED WITHOUT WARNING. THE VEHICLE WAS NOT TAKEN TO THE DEALER AND THE MANUFACTURER WAS NOT CONTACTED. THE VEHICLE WAS NOT REPAIRED. THE FAILURE MILEAGE WAS 90,600 AND THE CURRENT MILEAGE WAS 90,683. UPDATED 05/09/12 *BF THE CONSUMER STATED HER DAUGHTER WAS INJURED WHEN THE AIR BAGS DEPLOYED FOR NO REASON. UPDATED 06/01/12

NHTSA ODI #10448632

65,000 miles · Nov 11, 2011
Power Train

I HAVE AN 03 MERCEDES E500. AT ABOUT 65000 ML I HAD GLYCOL IN MY TRANSMISSION DUE TO RADIATOR FAILURE. I TOOK IT TO MERCEDES SARASOTA AND THEY SAID IT WILL COST $5000 AND THEY HAVE TO CHANGE THE RADIATOR AND THE TRANSMISSION. I WAS READING THE MERCEDES WORLD FORUM AND I SEE THAT LOT OF PEOPLE HAD THE SAME PROBLEM. AT THE AND COS…

Read full complaint

I HAVE AN 03 MERCEDES E500. AT ABOUT 65000 ML I HAD GLYCOL IN MY TRANSMISSION DUE TO RADIATOR FAILURE. I TOOK IT TO MERCEDES SARASOTA AND THEY SAID IT WILL COST $5000 AND THEY HAVE TO CHANGE THE RADIATOR AND THE TRANSMISSION. I WAS READING THE MERCEDES WORLD FORUM AND I SEE THAT LOT OF PEOPLE HAD THE SAME PROBLEM. AT THE AND COST ME $3000 AT AAMCO. I HOPE MERCEDES WILL ISSUE A RECALL FOR THIS PROBLEM. *TR

NHTSA ODI #10435280

40,000 miles · Oct 31, 2011
Fuel System, Gasoline

STRONG SMELL OF GASOLINE EVERY TIME I FILL UP AND UNTIL I DRIVE ABOUT 50 MILES. I WAS TOLD BY A GERMAN AUTO REPAIR SHOP THAT IT IS A CRACKED GAS TANK AND THAT THIS IS A SYSTEMIC PROBLEM WITH MERCEDES E-CLASS MODELS FROM 2003-2005. THE SMELL APPEARS TO BE EMANATING FROM THE REAR PASSENGER DRIVER'S SIDE. I HAVE ALSO BEEN TOLD T…

Read full complaint

STRONG SMELL OF GASOLINE EVERY TIME I FILL UP AND UNTIL I DRIVE ABOUT 50 MILES. I WAS TOLD BY A GERMAN AUTO REPAIR SHOP THAT IT IS A CRACKED GAS TANK AND THAT THIS IS A SYSTEMIC PROBLEM WITH MERCEDES E-CLASS MODELS FROM 2003-2005. THE SMELL APPEARS TO BE EMANATING FROM THE REAR PASSENGER DRIVER'S SIDE. I HAVE ALSO BEEN TOLD THERE WAS A RECALL FOR THIS EXACT ISSUE IN EUROPE AND ASIA BUT THAT MERCEDES NEVER ISSUED A RECALL IN THE US FOR THIS ISSUE DESPITE BEING EXTREMELY PERVASIVE. I DRIVE MY CHILDREN IN THIS CAR AND I AM INCREASINGLY CONCERNED ABOUT THIS DANGEROUS SITUATION. THE REPAIR PRICE I WAS QUOTED WAS ABOUT $2400. THIS SEEMS LIKE IT SHOULD BE A MERCEDES PROBLEM, NOT A CONSUMER PROBLEM. NOBODY SHOULD EXPECT THEIR GAS TANK TO CRACK AT ANY POINT! *TR

NHTSA ODI #10433623

80,950 miles · Sep 10, 2011
Engine And Engine CoolingVehicle Speed Control

AS I WAS MERGING ON TO THE HIGHWAY FROM ANOTHER HIGHWAY AT ABOUT 40MPH, I HAD TO SPEED UP BECAUSE OF THE TRAFFIC THAT WAS COMING TOWARDS ME AND ALSO TO BLEND IN WITH THE REST OF THE CARS SPEEDS. I WENT TO ACCELERATE, BUT NOTHING HAPPENED. LET OFF THE GAS, AND THEN PUNCHED THE PEDAL ALL THE WAY, BUT STILL NO SIGN OF ACCELERATION…

Read full complaint

AS I WAS MERGING ON TO THE HIGHWAY FROM ANOTHER HIGHWAY AT ABOUT 40MPH, I HAD TO SPEED UP BECAUSE OF THE TRAFFIC THAT WAS COMING TOWARDS ME AND ALSO TO BLEND IN WITH THE REST OF THE CARS SPEEDS. I WENT TO ACCELERATE, BUT NOTHING HAPPENED. LET OFF THE GAS, AND THEN PUNCHED THE PEDAL ALL THE WAY, BUT STILL NO SIGN OF ACCELERATION. I KEPT MY FOOT ON THE GAS AND ABOUT 3 SECONDS LATER, THE CAR BEGAN SLOWLY TO SPEED UP...ONE MPH AT A TIME. IT TOOK SOME TIME TO MAKE IT SO 65MPH. AFTER REACHING THAT SPEED, I TRIED SOME TROUBLESHOOTING. I LET OFF GAS PEDAL COMPLETELY AND STEPPED BACK ON IT. THAT DIDN'T HELP. I ALSO TRIED USING MY SHIFTRONIC, AND THAT DIDN'T HELP. I TOOK THE NEXT OFF RAMP AND CAME TO A COMPLETE STOP AT A TRAFFIC LIGHT. I WENT INTO PARK AND RIGHT BACK INTO "D". I STILL HAD THE ACCELERATING PROBLEM. THE ONLY WAY IT WENT AWAY WAS TO SHUT OFF THE CAR AND TURN IT BACK ON. IT CURRENTLY WORKS WELL WITHOUT ANY SIGNS OF A PROBLEM. I DID NOT RECEIVE A MESSAGE ON THE DASHBOARD NOR DID I RECEIVE AN ERROR CODE. *TR

NHTSA ODI #10424560

66,002 miles · Feb 7, 2011
Suspension

BOTH FRONT AND REAR AIR SHOCKS WENT WITHIN 2000 MILES OF EACH OTHER 64000 AND 66000 MILES. THESE SHOCKS ARE THOUSANDS OF DOLLARS AND ARE A MAJOR PROBLEM WITH THESE CARS. THEY WERE NOT ENGINEERED PROPERLY OR THEY SHOULD HAVE LASTED MUCH LONGER. MERCEDES WILL DO NOTHING ABOUT..

NHTSA ODI #10381948

81,777 miles · Dec 24, 2010
Power Train

IN JUNE OF 2010 I PURCHASED A 2003 MERCEDES BENZ E500. THE CAR AT TIMES WOULD SHIFT HEAVY AND AT TIMES WOULD SHIFT DOWN SUDDENLY OR ACCELERATE SUDDENLY AND DRAMATICALLY WHEN THE ACCELERATOR WAS PRESS LIGHTLY FROM A STOP. THE PROBLEM CONTINUED TO THE PRESENT TIME AND HAS GOTTEN WORSE NOW IN THE WINTER MONTHS. I KNOW THE CAR IS A…

Read full complaint

IN JUNE OF 2010 I PURCHASED A 2003 MERCEDES BENZ E500. THE CAR AT TIMES WOULD SHIFT HEAVY AND AT TIMES WOULD SHIFT DOWN SUDDENLY OR ACCELERATE SUDDENLY AND DRAMATICALLY WHEN THE ACCELERATOR WAS PRESS LIGHTLY FROM A STOP. THE PROBLEM CONTINUED TO THE PRESENT TIME AND HAS GOTTEN WORSE NOW IN THE WINTER MONTHS. I KNOW THE CAR IS A POTENTIAL DANGER BUT HAVE NO OTHER ALTERNATIVE BUT TO DRIVE IT. PLEASE HELP! *TR

NHTSA ODI #10372340

Official recalls

3

24V874000 · Visibility:sun/moon Roof Assembly

Nov 19, 2024

Mercedes-Benz USA, LLC (MBUSA) is recalling certain 2001-2011 C-Class, CLK, E-Class, and CLS vehicles. Please see the recall report for a complete list of models and model years. The glass sunroof panel may not be properly secured and can detach.

Consequence & remedy

Consequence: A detached sunroof panel can become a road hazard, increasing the risk of a crash.

Remedy: Dealers will inspect and replace the sunroof panel as necessary, free of charge. Owner notification letters were mailed January 10, 2025. Owners may contact MBUSA customer service at 1-800-367-6372. This recall is an expansion of previous NHTSA recall number 22V-954. MBUSA's number for this recall is 2024120001/2/3.

22V954000 · Visibility:sun/moon Roof Assembly

Dec 23, 2022

Mercedes-Benz USA, LLC (MBUSA) is recalling certain 2001-2011 C-Class, CLK, E-Class, and CLS vehicles. Please refer to MBUSA's recall report for specific vehicle model details. The glass sunroof panel may not be properly secured and may detach.

Consequence & remedy

Consequence: A detached sunroof panel may become a road hazard, increasing the risk of a crash.

Remedy: Dealers will inspect and replace the sunroof panel as necessary free of charge. Owner notification letters were mailed February 3, 2023. Owners may contact MBUSA customer service at 1-800-367-6372. This recall expands NHTSA recall number 19V-918. MBUSA's numbers for this recall are 2023010004, 2023010005, and 2023010006.

19V918000 · Visibility:sun/moon Roof Assembly

Dec 20, 2019

Mercedes-Benz USA, LLC. (MBUSA) is recalling certain 2001-2011 vehicles. The bonding between the glass panel and the sliding roof frame may deteriorate, possibly resulting in the glass panel detaching from the vehicle. For a full list of the affected models visit: https://static.nhtsa.gov/odi/rcl/2019/RMISC-19V918-4126.pdf

Consequence & remedy

Consequence: A detached glass panel can separate from the vehicle and become a road hazard, increasing the risk of a crash.

Remedy: MBUSA will notify owners, and dealers will inspect the glass panel bonding and replace the sliding roof, as necessary, free of charge. The recall began July 10, 2020. Owners may contact MBUSA customer service at 1-800-367-6372. MBUSA's number for this recall is 2020040011.

Model-level recall history does not show whether a particular VIN is affected or has received a repair. Check a VIN with NHTSA ↗

NHTSA investigations

1

EA13003 · Fuel Leakage From The Fuel Tank

Opened Mar 15, 2013 · Closed Dec 19, 2014

Status: closed (inferred from source dates) · Fuel System, Gasoline; Fuel System, Gasoline:delivery; Fuel System, Gasoline:delivery:fuel Pump; Fuel System, Gasoline:delivery:hoses, Lines/piping, And Fittings; Fuel System, Gasoline:storage; Fuel System, Gasoline:storage:tank Assembly

The Office of Defects Investigation (ODI) opened this investigation on January 23, 2012 as PE12-001 based on 20 consumer reports in model year (MY) 2003-2006 E55 AMG vehicles.Based on new reports in other E-Class vehicles, ODI upgraded the investigation to Engineering Analysis (EA) 13-003 on March 15, 2013, and expanded the scope to all E-Class vehicles through MY 2008.The complainants alleged a strong odor of gasoline fuel both inside and outside of their vehicle, particularly after refilling the fuel tank.Many of the complainants noted that the odor subsided or went away after driving some distance thereby lowering the fuel level in the tank.Other owners reported they would only fill the tank to about three quarters full to avoid the odor altogether.Some complainants alleged fuel leaked from the fuel filter/sender, located on the top of the fuel tank on the driver's side, and collected on top of the tank.There were also allegations that the fuel leaks were associated with an Emissions Recall Campaign (No. 2008020001) conducted by Mercedes-Benz USA, LLC (Mercedes) in 2008 on MY 2003-2006 E-Class and CLS-Class AMG models.The issue in the recall involved small cracks in the pressurized outlet fitting of the fuel filter/sender.AMG vehicles are high performance models that operate at higher fuel pressure and use a different fuel filter/sender and fuel pump than non-AMG models.Information on Recall No. 2008020001 is available from the U.S. Environmental Protection Agency (EPA) website at www.EPA.gov.ODI's investigation found various leak sources that are unrelated to the outlet fitting cited in the EPA recall campaign.Through interviews with complainants, field inspections of complaint vehicles, and the collection and laboratory analysis of failed parts, three identifiable leak sources were found.The component parts and areas of the leaks involve the On-Board Diagnostic fuel tank pressure sensor (located on top of the fuel filter/sender), the outlet of the centrally mounted fuel tank fuel filling limiter valve, and the top of the fuel pump. These areas of leakage are located at the top of the fuel tank in unpressurized parts of the fuel system. When the tank is full, fuel can slowly weep/seep from micro-cracks in these components and may collect in cavities on top of the filter/sender, pump, or tank.Contrary to complainant's allegations that fuel entered the inside of their vehicle under the rear seat bench, neither ODI nor Mercedes found a plausible way for this to occur.The fuel tank is located outside of the passenger compartment, attached to the underside of the vehicle.The service access ports for the fuel filter/sender (driver's side) and fuel pump (passenger's side) are located under the rear seat bench, covered by a steel plate, sealed and bolted to the vehicle floor.When technicians service the fuel filter/sender, which has a regularly scheduled 60,000 mile service interval, and/or the fuel pump, the work is performed from inside the vehicle by working through the access ports.By letter dated September 4, 2014, Mercedes has notified the agency that it will extend the original warranty coverage to 15 years and unlimited mileage on Covered Fuel Tank Components in E-Class vehicles in MY 2003-2009 and CLS-Class vehicles in MY 2006-2011.The covered fuel tank components for the warranty extension include the fuel tank, fuel filter/sender, fuel pump, and all related gaskets/seals and retention rings.ODI is closing this investigation based on the manufacturer's extend warranty of the affected fuel system components and in consideration that the nature of the leaks does not appear to present an un

Additional source detail variants (6)

Fuel System, Gasoline:delivery:fuel Pump

The Office of Defects Investigation (ODI) opened this investigation on January 23, 2012 as PE12-001 based on 20 consumer reports in model year (MY) 2003-2006 E55 AMG vehicles.Based on new reports in other E-Class vehicles, ODI upgraded the investigation to Engineering Analysis (EA) 13-003 on March 15, 2013, and expanded the scope to all E-Class vehicles through MY 2008.The complainants alleged a strong odor of gasoline fuel both inside and outside of their vehicle, particularly after refilling the fuel tank.Many of the complainants noted that the odor subsided or went away after driving some distance thereby lowering the fuel level in the tank.Other owners reported they would only fill the tank to about three quarters full to avoid the odor altogether.Some complainants alleged fuel leaked from the fuel filter/sender, located on the top of the fuel tank on the driver's side, and collected on top of the tank.There were also allegations that the fuel leaks were associated with an Emissions Recall Campaign (No. 2008020001) conducted by Mercedes-Benz USA, LLC (Mercedes) in 2008 on MY 2003-2006 E-Class and CLS-Class AMG models.The issue in the recall involved small cracks in the pressurized outlet fitting of the fuel filter/sender.AMG vehicles are high performance models that operate at higher fuel pressure and use a different fuel filter/sender and fuel pump than non-AMG models.Information on Recall No. 2008020001 is available from the U.S. Environmental Protection Agency (EPA) website at www.EPA.gov.ODI's investigation found various leak sources that are unrelated to the outlet fitting cited in the EPA recall campaign.Through interviews with complainants, field inspections of complaint vehicles, and the collection and laboratory analysis of failed parts, three identifiable leak sources were found.The component parts and areas of the leaks involve the On-Board Diagnostic fuel tank pressure sensor (located on top of the fuel filter/sender), the outlet of the centrally mounted fuel tank fuel filling limiter valve, and the top of the fuel pump. These areas of leakage are located at the top of the fuel tank in unpressurized parts of the fuel system. When the tank is full, fuel can slowly weep/seep from micro-cracks in these components and may collect in cavities on top of the filter/sender, pump, or tank.Contrary to complainant's allegations that fuel entered the inside of their vehicle under the rear seat bench, neither ODI nor Mercedes found a plausible way for this to occur.The fuel tank is located outside of the passenger compartment, attached to the underside of the vehicle.The service access ports for the fuel filter/sender (driver's side) and fuel pump (passenger's side) are located under the rear seat bench, covered by a steel plate, sealed and bolted to the vehicle floor.When technicians service the fuel filter/sender, which has a regularly scheduled 60,000 mile service interval, and/or the fuel pump, the work is performed from inside the vehicle by working through the access ports.By letter dated September 4, 2014, Mercedes has notified the agency that it will extend the original warranty coverage to 15 years and unlimited mileage on Covered Fuel Tank Components in E-Class vehicles in MY 2003-2009 and CLS-Class vehicles in MY 2006-2011.The covered fuel tank components for the warranty extension include the fuel tank, fuel filter/sender, fuel pump, and all related gaskets/seals and retention rings.ODI is closing this investigation based on the manufacturer's extend warranty of the affected fuel system components and in consideration that the nature of the leaks does not appear to present an un

Fuel System, Gasoline:delivery:hoses, Lines/piping, And Fittings

The Office of Defects Investigation (ODI) opened this investigation on January 23, 2012 as PE12-001 based on 20 consumer reports in model year (MY) 2003-2006 E55 AMG vehicles.Based on new reports in other E-Class vehicles, ODI upgraded the investigation to Engineering Analysis (EA) 13-003 on March 15, 2013, and expanded the scope to all E-Class vehicles through MY 2008.The complainants alleged a strong odor of gasoline fuel both inside and outside of their vehicle, particularly after refilling the fuel tank.Many of the complainants noted that the odor subsided or went away after driving some distance thereby lowering the fuel level in the tank.Other owners reported they would only fill the tank to about three quarters full to avoid the odor altogether.Some complainants alleged fuel leaked from the fuel filter/sender, located on the top of the fuel tank on the driver's side, and collected on top of the tank.There were also allegations that the fuel leaks were associated with an Emissions Recall Campaign (No. 2008020001) conducted by Mercedes-Benz USA, LLC (Mercedes) in 2008 on MY 2003-2006 E-Class and CLS-Class AMG models.The issue in the recall involved small cracks in the pressurized outlet fitting of the fuel filter/sender.AMG vehicles are high performance models that operate at higher fuel pressure and use a different fuel filter/sender and fuel pump than non-AMG models.Information on Recall No. 2008020001 is available from the U.S. Environmental Protection Agency (EPA) website at www.EPA.gov.ODI's investigation found various leak sources that are unrelated to the outlet fitting cited in the EPA recall campaign.Through interviews with complainants, field inspections of complaint vehicles, and the collection and laboratory analysis of failed parts, three identifiable leak sources were found.The component parts and areas of the leaks involve the On-Board Diagnostic fuel tank pressure sensor (located on top of the fuel filter/sender), the outlet of the centrally mounted fuel tank fuel filling limiter valve, and the top of the fuel pump. These areas of leakage are located at the top of the fuel tank in unpressurized parts of the fuel system. When the tank is full, fuel can slowly weep/seep from micro-cracks in these components and may collect in cavities on top of the filter/sender, pump, or tank.Contrary to complainant's allegations that fuel entered the inside of their vehicle under the rear seat bench, neither ODI nor Mercedes found a plausible way for this to occur.The fuel tank is located outside of the passenger compartment, attached to the underside of the vehicle.The service access ports for the fuel filter/sender (driver's side) and fuel pump (passenger's side) are located under the rear seat bench, covered by a steel plate, sealed and bolted to the vehicle floor.When technicians service the fuel filter/sender, which has a regularly scheduled 60,000 mile service interval, and/or the fuel pump, the work is performed from inside the vehicle by working through the access ports.By letter dated September 4, 2014, Mercedes has notified the agency that it will extend the original warranty coverage to 15 years and unlimited mileage on Covered Fuel Tank Components in E-Class vehicles in MY 2003-2009 and CLS-Class vehicles in MY 2006-2011.The covered fuel tank components for the warranty extension include the fuel tank, fuel filter/sender, fuel pump, and all related gaskets/seals and retention rings.ODI is closing this investigation based on the manufacturer's extend warranty of the affected fuel system components and in consideration that the nature of the leaks does not appear to present an un

Fuel System, Gasoline:delivery

The Office of Defects Investigation (ODI) opened this investigation on January 23, 2012 as PE12-001 based on 20 consumer reports in model year (MY) 2003-2006 E55 AMG vehicles.Based on new reports in other E-Class vehicles, ODI upgraded the investigation to Engineering Analysis (EA) 13-003 on March 15, 2013, and expanded the scope to all E-Class vehicles through MY 2008.The complainants alleged a strong odor of gasoline fuel both inside and outside of their vehicle, particularly after refilling the fuel tank.Many of the complainants noted that the odor subsided or went away after driving some distance thereby lowering the fuel level in the tank.Other owners reported they would only fill the tank to about three quarters full to avoid the odor altogether.Some complainants alleged fuel leaked from the fuel filter/sender, located on the top of the fuel tank on the driver's side, and collected on top of the tank.There were also allegations that the fuel leaks were associated with an Emissions Recall Campaign (No. 2008020001) conducted by Mercedes-Benz USA, LLC (Mercedes) in 2008 on MY 2003-2006 E-Class and CLS-Class AMG models.The issue in the recall involved small cracks in the pressurized outlet fitting of the fuel filter/sender.AMG vehicles are high performance models that operate at higher fuel pressure and use a different fuel filter/sender and fuel pump than non-AMG models.Information on Recall No. 2008020001 is available from the U.S. Environmental Protection Agency (EPA) website at www.EPA.gov.ODI's investigation found various leak sources that are unrelated to the outlet fitting cited in the EPA recall campaign.Through interviews with complainants, field inspections of complaint vehicles, and the collection and laboratory analysis of failed parts, three identifiable leak sources were found.The component parts and areas of the leaks involve the On-Board Diagnostic fuel tank pressure sensor (located on top of the fuel filter/sender), the outlet of the centrally mounted fuel tank fuel filling limiter valve, and the top of the fuel pump. These areas of leakage are located at the top of the fuel tank in unpressurized parts of the fuel system. When the tank is full, fuel can slowly weep/seep from micro-cracks in these components and may collect in cavities on top of the filter/sender, pump, or tank.Contrary to complainant's allegations that fuel entered the inside of their vehicle under the rear seat bench, neither ODI nor Mercedes found a plausible way for this to occur.The fuel tank is located outside of the passenger compartment, attached to the underside of the vehicle.The service access ports for the fuel filter/sender (driver's side) and fuel pump (passenger's side) are located under the rear seat bench, covered by a steel plate, sealed and bolted to the vehicle floor.When technicians service the fuel filter/sender, which has a regularly scheduled 60,000 mile service interval, and/or the fuel pump, the work is performed from inside the vehicle by working through the access ports.By letter dated September 4, 2014, Mercedes has notified the agency that it will extend the original warranty coverage to 15 years and unlimited mileage on Covered Fuel Tank Components in E-Class vehicles in MY 2003-2009 and CLS-Class vehicles in MY 2006-2011.The covered fuel tank components for the warranty extension include the fuel tank, fuel filter/sender, fuel pump, and all related gaskets/seals and retention rings.ODI is closing this investigation based on the manufacturer's extend warranty of the affected fuel system components and in consideration that the nature of the leaks does not appear to present an un

Fuel System, Gasoline

The Office of Defects Investigation (ODI) opened this investigation on January 23, 2012 as PE12-001 based on 20 consumer reports in model year (MY) 2003-2006 E55 AMG vehicles.Based on new reports in other E-Class vehicles, ODI upgraded the investigation to Engineering Analysis (EA) 13-003 on March 15, 2013, and expanded the scope to all E-Class vehicles through MY 2008.The complainants alleged a strong odor of gasoline fuel both inside and outside of their vehicle, particularly after refilling the fuel tank.Many of the complainants noted that the odor subsided or went away after driving some distance thereby lowering the fuel level in the tank.Other owners reported they would only fill the tank to about three quarters full to avoid the odor altogether.Some complainants alleged fuel leaked from the fuel filter/sender, located on the top of the fuel tank on the driver's side, and collected on top of the tank.There were also allegations that the fuel leaks were associated with an Emissions Recall Campaign (No. 2008020001) conducted by Mercedes-Benz USA, LLC (Mercedes) in 2008 on MY 2003-2006 E-Class and CLS-Class AMG models.The issue in the recall involved small cracks in the pressurized outlet fitting of the fuel filter/sender.AMG vehicles are high performance models that operate at higher fuel pressure and use a different fuel filter/sender and fuel pump than non-AMG models.Information on Recall No. 2008020001 is available from the U.S. Environmental Protection Agency (EPA) website at www.EPA.gov.ODI's investigation found various leak sources that are unrelated to the outlet fitting cited in the EPA recall campaign.Through interviews with complainants, field inspections of complaint vehicles, and the collection and laboratory analysis of failed parts, three identifiable leak sources were found.The component parts and areas of the leaks involve the On-Board Diagnostic fuel tank pressure sensor (located on top of the fuel filter/sender), the outlet of the centrally mounted fuel tank fuel filling limiter valve, and the top of the fuel pump. These areas of leakage are located at the top of the fuel tank in unpressurized parts of the fuel system. When the tank is full, fuel can slowly weep/seep from micro-cracks in these components and may collect in cavities on top of the filter/sender, pump, or tank.Contrary to complainant's allegations that fuel entered the inside of their vehicle under the rear seat bench, neither ODI nor Mercedes found a plausible way for this to occur.The fuel tank is located outside of the passenger compartment, attached to the underside of the vehicle.The service access ports for the fuel filter/sender (driver's side) and fuel pump (passenger's side) are located under the rear seat bench, covered by a steel plate, sealed and bolted to the vehicle floor.When technicians service the fuel filter/sender, which has a regularly scheduled 60,000 mile service interval, and/or the fuel pump, the work is performed from inside the vehicle by working through the access ports.By letter dated September 4, 2014, Mercedes has notified the agency that it will extend the original warranty coverage to 15 years and unlimited mileage on Covered Fuel Tank Components in E-Class vehicles in MY 2003-2009 and CLS-Class vehicles in MY 2006-2011.The covered fuel tank components for the warranty extension include the fuel tank, fuel filter/sender, fuel pump, and all related gaskets/seals and retention rings.ODI is closing this investigation based on the manufacturer's extend warranty of the affected fuel system components and in consideration that the nature of the leaks does not appear to present an un

Fuel System, Gasoline:storage

The Office of Defects Investigation (ODI) opened this investigation on January 23, 2012 as PE12-001 based on 20 consumer reports in model year (MY) 2003-2006 E55 AMG vehicles.Based on new reports in other E-Class vehicles, ODI upgraded the investigation to Engineering Analysis (EA) 13-003 on March 15, 2013, and expanded the scope to all E-Class vehicles through MY 2008.The complainants alleged a strong odor of gasoline fuel both inside and outside of their vehicle, particularly after refilling the fuel tank.Many of the complainants noted that the odor subsided or went away after driving some distance thereby lowering the fuel level in the tank.Other owners reported they would only fill the tank to about three quarters full to avoid the odor altogether.Some complainants alleged fuel leaked from the fuel filter/sender, located on the top of the fuel tank on the driver's side, and collected on top of the tank.There were also allegations that the fuel leaks were associated with an Emissions Recall Campaign (No. 2008020001) conducted by Mercedes-Benz USA, LLC (Mercedes) in 2008 on MY 2003-2006 E-Class and CLS-Class AMG models.The issue in the recall involved small cracks in the pressurized outlet fitting of the fuel filter/sender.AMG vehicles are high performance models that operate at higher fuel pressure and use a different fuel filter/sender and fuel pump than non-AMG models.Information on Recall No. 2008020001 is available from the U.S. Environmental Protection Agency (EPA) website at www.EPA.gov.ODI's investigation found various leak sources that are unrelated to the outlet fitting cited in the EPA recall campaign.Through interviews with complainants, field inspections of complaint vehicles, and the collection and laboratory analysis of failed parts, three identifiable leak sources were found.The component parts and areas of the leaks involve the On-Board Diagnostic fuel tank pressure sensor (located on top of the fuel filter/sender), the outlet of the centrally mounted fuel tank fuel filling limiter valve, and the top of the fuel pump. These areas of leakage are located at the top of the fuel tank in unpressurized parts of the fuel system. When the tank is full, fuel can slowly weep/seep from micro-cracks in these components and may collect in cavities on top of the filter/sender, pump, or tank.Contrary to complainant's allegations that fuel entered the inside of their vehicle under the rear seat bench, neither ODI nor Mercedes found a plausible way for this to occur.The fuel tank is located outside of the passenger compartment, attached to the underside of the vehicle.The service access ports for the fuel filter/sender (driver's side) and fuel pump (passenger's side) are located under the rear seat bench, covered by a steel plate, sealed and bolted to the vehicle floor.When technicians service the fuel filter/sender, which has a regularly scheduled 60,000 mile service interval, and/or the fuel pump, the work is performed from inside the vehicle by working through the access ports.By letter dated September 4, 2014, Mercedes has notified the agency that it will extend the original warranty coverage to 15 years and unlimited mileage on Covered Fuel Tank Components in E-Class vehicles in MY 2003-2009 and CLS-Class vehicles in MY 2006-2011.The covered fuel tank components for the warranty extension include the fuel tank, fuel filter/sender, fuel pump, and all related gaskets/seals and retention rings.ODI is closing this investigation based on the manufacturer's extend warranty of the affected fuel system components and in consideration that the nature of the leaks does not appear to present an un

Fuel System, Gasoline:storage:tank Assembly

The Office of Defects Investigation (ODI) opened this investigation on January 23, 2012 as PE12-001 based on 20 consumer reports in model year (MY) 2003-2006 E55 AMG vehicles.Based on new reports in other E-Class vehicles, ODI upgraded the investigation to Engineering Analysis (EA) 13-003 on March 15, 2013, and expanded the scope to all E-Class vehicles through MY 2008.The complainants alleged a strong odor of gasoline fuel both inside and outside of their vehicle, particularly after refilling the fuel tank.Many of the complainants noted that the odor subsided or went away after driving some distance thereby lowering the fuel level in the tank.Other owners reported they would only fill the tank to about three quarters full to avoid the odor altogether.Some complainants alleged fuel leaked from the fuel filter/sender, located on the top of the fuel tank on the driver's side, and collected on top of the tank.There were also allegations that the fuel leaks were associated with an Emissions Recall Campaign (No. 2008020001) conducted by Mercedes-Benz USA, LLC (Mercedes) in 2008 on MY 2003-2006 E-Class and CLS-Class AMG models.The issue in the recall involved small cracks in the pressurized outlet fitting of the fuel filter/sender.AMG vehicles are high performance models that operate at higher fuel pressure and use a different fuel filter/sender and fuel pump than non-AMG models.Information on Recall No. 2008020001 is available from the U.S. Environmental Protection Agency (EPA) website at www.EPA.gov.ODI's investigation found various leak sources that are unrelated to the outlet fitting cited in the EPA recall campaign.Through interviews with complainants, field inspections of complaint vehicles, and the collection and laboratory analysis of failed parts, three identifiable leak sources were found.The component parts and areas of the leaks involve the On-Board Diagnostic fuel tank pressure sensor (located on top of the fuel filter/sender), the outlet of the centrally mounted fuel tank fuel filling limiter valve, and the top of the fuel pump. These areas of leakage are located at the top of the fuel tank in unpressurized parts of the fuel system. When the tank is full, fuel can slowly weep/seep from micro-cracks in these components and may collect in cavities on top of the filter/sender, pump, or tank.Contrary to complainant's allegations that fuel entered the inside of their vehicle under the rear seat bench, neither ODI nor Mercedes found a plausible way for this to occur.The fuel tank is located outside of the passenger compartment, attached to the underside of the vehicle.The service access ports for the fuel filter/sender (driver's side) and fuel pump (passenger's side) are located under the rear seat bench, covered by a steel plate, sealed and bolted to the vehicle floor.When technicians service the fuel filter/sender, which has a regularly scheduled 60,000 mile service interval, and/or the fuel pump, the work is performed from inside the vehicle by working through the access ports.By letter dated September 4, 2014, Mercedes has notified the agency that it will extend the original warranty coverage to 15 years and unlimited mileage on Covered Fuel Tank Components in E-Class vehicles in MY 2003-2009 and CLS-Class vehicles in MY 2006-2011.The covered fuel tank components for the warranty extension include the fuel tank, fuel filter/sender, fuel pump, and all related gaskets/seals and retention rings.ODI is closing this investigation based on the manufacturer's extend warranty of the affected fuel system components and in consideration that the nature of the leaks does not appear to present an un