1. FIRE BEHIND FURNACE PANELING 8:30 AM MST I NOTICED SMOKE COMING FROM UNDER THE FURNACE PANEL. I SHUT DOWN THE FURNACE AND OPENED THE FURNACE PANEL. UPON OPENING, I DISCOVERED THE LINOLEUM BURNING IN A SIX INCH DIAMETER OVAL AREA. I EXTINGUISHED THE FIRE. EXAMINATION SHOWED THE FURNACE FEEDS THE DUCT SYSTEM UNDER THE FLOOR B…
Read full complaint
1. FIRE BEHIND FURNACE PANELING 8:30 AM MST I NOTICED SMOKE COMING FROM UNDER THE FURNACE PANEL. I SHUT DOWN THE FURNACE AND OPENED THE FURNACE PANEL. UPON OPENING, I DISCOVERED THE LINOLEUM BURNING IN A SIX INCH DIAMETER OVAL AREA. I EXTINGUISHED THE FIRE. EXAMINATION SHOWED THE FURNACE FEEDS THE DUCT SYSTEM UNDER THE FLOOR BY MEANS OF A HOLE IN THE FLOOR THAT IS SUPPOSED TO ALIGN WITH THE FURNACE CHAMBER HOLE. THE SPACE BETWEEN FURNACE AND FLOOR HAS A FITTED GASKET AND ALUMINUM-LIKE FOIL PROTECTING THE FLOOR FROM THE HEATED AIR. HOWEVER, THE HOLE IN THE FLOOR WAS MISALIGNED BY 3" SUCH THAT THE FURNACE SLOT WAS OVERLAPPING 3" OF ACTUAL LINOLEUM COVERED FLOOR. THIS ALLOWED THE FURNACE HEATED AIR TO BLOW DIRECTLY ON THE LINOLEUM AND SET IT ON FIRE. THIS VEHICLE IS LOCATED ON-SITE OF OUR HOUSE BUILDING, SO I ENLISTED HELP FROM THE HVAC CONTRACTOR WORKING ON THE HOUSE; AND WE CORRECTED THE HOLE ALIGNMENT AND PUT IN SHEET METAL, INSULATION, GASKETS, AND HEAT BARRIERS TO CORRECT THE SITUATION. 2. EARLIER HAZARD PROBLEM. SEVERAL MONTHS EARLIER, WHEN ATTEMPTING ACCESS TO BLACK AND GRAY WATER VALVES, IT WAS VERY EASY TO CUT YOUR HAND ON SHARP EDGED SHEET METAL PANELS ABOVE THE VALVES. I CORRECTED THIS PROBLEM BY PUTTING TUBING OVER THE SHARP EDGES. HOWEVER, WHEN I CALLED THE COMPANY ABOUT THIS HAZARD, I WAS TOLD BY A CUSTOMER SERVICE PERSON THAT IT "WASN'T WARRANTY". I EXPLAINED I WAS ALERTING THEM TO HAZARD, DESIGN AND QUALITY CONTROL PROBLEMS. 3. MISALIGNED BATH ROOM DOOR, UNLABELED ELECTRICAL SWITCHES, AND CO DETECTOR. THESE ITEMS REPRESENT THE MINOR ANNOYANCES THAT I HAVE CORRECTED ALONG WITH THE REPLACEMENT OF THE CO DETECTOR POWER SYSTEM BY RECALL. THE REVERSE SUCCESSION OF THESE ABOVE ITEMS HAS LED ME TO BELIEVE THERE IS A SERIOUS LACK OF QUALITY/MANAGEMENT CONTROL IN PLACE TO TRANSFER DESIGN TO PRODUCTION AND WITH INFORMATION FLOW TO RESPONSIBLE MANAGEMENT. THIS IS CREATING SERIOUS INJURY OR DEATH HAZARDS TO THE EQUIPMENT USER. *TR
Keystone RV Company (Keystone) is recalling various 2003-2018 Crossroads, Dutchmen, and Keystone recreational trailers equipped with Kidde Plastic-Handle or Push Button 'Pindicator' Fire Extinguishers. A list of the affected trailer models is available at: https://static.nhtsa.gov/odi/rcl/2017/RMISC-17V755-5127.pdf. These extinguishers may become clogged, preventing the extinguisher from discharging as expected or excessive force may be needed to activate the extinguisher. Additionally, in certain models, the nozzle may detach from the valve assembly with enough force that it could cause injury and also render the product inoperable. For a full list of the affected fire extinguisher models visit: https://static.nhtsa.gov/odi/rcl/2017/RMISC-17E062-5427.pdf
Consequence & remedy
Consequence: In the event of a fire, if the fire extinguisher does not function properly, it can increase the risk of injury.
Remedy: Keystone will notify owners and instruct them to contact Kidde for a replacement fire extinguisher, free of charge. The recall began on January 15, 2018. Owners may contact Keystone customer service at 1-574-535-2100, or Kidde customer service toll-free at 1-855-262-3540, or online at www.kidde.com and click on "Product Safety Recall" for more information. Keystone's number for this recall is 17-307.
ON CERTAIN RECREATIONAL VEHICLES EQUIPPED WITH A 9 VOLT BATTERY OPERATED CARBON MONOXIDE (CO) DETECTOR, IF THE BATTERY IN THE DETECTOR GOES DEAD OR IS REMOVED, THE DETECTOR WILL NOT FUNCTION AND THEREFORE CAN NOT WARN THE OCCUPANTS IF CO REACHES A HARMFUL LEVEL.
Consequence & remedy
Consequence: IF CO REACHES A HARMFUL LEVEL, SERIOUS ILLNESS OR DEATH COULD RESULT TO THE OCCUPANTS.
Remedy: DEALERS WILL INSTALL A HARD WIRED 12 VOLT CO DETECTORS FREE OF CHARGE. THE RECALL BEGAN ON JUNE 5, 2006. OWNERS MAY CONTACT KEYSTONE AT 866-425-4369.
ON CERTAIN FIFTH WHEEL TRAILERS, PROPANE LINES WERE INCORRECTLY POSITIONED DURING MANUFACTURING AND DO NOT HAVE SUFFICIENT CLEARANCE BETWEEN THE FLOOR OF THE SLIDE ROOM AND THE OUTSIDE WALL OF THE SLIDE ROOM.
Consequence & remedy
Consequence: THE COPPER LINES MAY GET PINCHED WHEN THE DOOR SIDE SLIDE-OUT IS RETRACTED. THE LINES COULD BE DAMAGED AND LEAK PROPANE RESULTING IN A FIRE.
Remedy: DEALERS WILL RELOCATE THE LINES AND A STOP WILL BE ADDED TO PREVENT THE LINES FROM BEING DAMAGED IN THE FUTURE. THE RECALL BEGAN ON MARCH 27, 2006. ALL VEHICLES ARE LOCATED AT DEALERSHIPS AND HAVE NOT BEEN SOLD TO CONSUMERS.
Model-level recall history does not show whether a particular VIN is affected or has received a repair. Check a VIN with NHTSA ↗