Tap a category to read its complaints. One report may name several components.
When problems were reported
Mileage at the reported incident
Limited mileage data: 4 of 222 reports include usable mileage. There isn’t enough coverage to show a useful chart.
NHTSA’s mileage field refers to the reported incident, not necessarily the filing date. This shows report counts, not the likelihood of a failure.
What to inspect
Issues worth paying extra attention to based on owner reports.
Electrical System. Review the 176 owner reports in this category and discuss these concerns during a pre-purchase inspection. Read reports →
Fuel/propulsion System. Review the 51 owner reports in this category and discuss these concerns during a pre-purchase inspection. Read reports →
Power Train. Review the 37 owner reports in this category and discuss these concerns during a pre-purchase inspection. Read reports →
NHTSA owner reports · September 18, 2026 snapshot.
5 crash reports0 fire reports1 injury reports
What owners actually said
222 reports
Mileage unknown · Mar 24, 2025
Electrical SystemEngineVehicle Speed Control
On March 22, 2025, our 2022 Hyundai Ioniq 5 suffered a sudden, complete loss of power while driving at night, after receiving Hyundai’s recall service in January. While driving on city roads, the car displayed “Check Battery” errors despite the main EV battery showing ~75% charge. After stopping, we had AAA install a new 12V bat…
Read full complaint
On March 22, 2025, our 2022 Hyundai Ioniq 5 suffered a sudden, complete loss of power while driving at night, after receiving Hyundai’s recall service in January. While driving on city roads, the car displayed “Check Battery” errors despite the main EV battery showing ~75% charge. After stopping, we had AAA install a new 12V battery, which did not resolve the issue. Minutes later, while crossing a Y-shaped highway interchange, the car lost the ability to accelerate, leaving us stranded in a dangerous area. Hyundai Roadside Assistance gave an 89-minute ETA and failed to dispatch a tow capable of transporting our family of three. We were forced to call our insurance to tow the vehicle to safety. The car is now inoperable at a dealership. Hyundai has not followed up. This is a major safety concern — involving either the 12V system or software post-recall — and could impact other vehicles. Photos, screenshots, and documentation are available.
NHTSA ODI #11650176
Mileage unknown · Feb 25, 2025
Electrical SystemPower Train
About 2 minutes after I started driving, I got a "Stop Vehicle and Check Power Supply" warning. The car slower to about 20 mph and would not go any faster. After returning home, I had the car towed to the dealership. Hyundai said that the ICCU unit failed. This was days after the same dealer performed recall work that was su…
Read full complaint
About 2 minutes after I started driving, I got a "Stop Vehicle and Check Power Supply" warning. The car slower to about 20 mph and would not go any faster. After returning home, I had the car towed to the dealership. Hyundai said that the ICCU unit failed. This was days after the same dealer performed recall work that was supposed to address ICCU issues.
NHTSA ODI #11644857
Mileage unknown · Feb 19, 2025
Electrical System
Car had a warning Check Electrical System and the 12volt drained. ICCU Failed car undrivable.
NHTSA ODI #11643656
Mileage unknown · Feb 18, 2025
Unknown Or Other
Car won't super charge. ICCU has been backordered for a month.
NHTSA ODI #11643414
Mileage unknown · Feb 17, 2025
Engine
Battery warning appeared. Car stopped after a few minutes. Car can’t be started. Complete list of power. Dealer confirmed it was the ICCU. I had a recall service done in 11.19.2024y last time I got an info about a recall was 1.9.2024
Started car and proceeded to drive to work. 1 mile from home, heard a "pop" noise and the car displayed "Check Electric Vehicle System" warning and went into a "turtle" mode that limited speed. Luckily I was on a side street and had not yet made the turn onto the main highway or it may have obstructed traffic or resulted in a c…
Read full complaint
Started car and proceeded to drive to work. 1 mile from home, heard a "pop" noise and the car displayed "Check Electric Vehicle System" warning and went into a "turtle" mode that limited speed. Luckily I was on a side street and had not yet made the turn onto the main highway or it may have obstructed traffic or resulted in a crash. I was able to return home and have the car towed back to a Hyundai dealer for diagnosis and repair. The dealer identified the issue as the ICCU fuse and ICCU itself that needed replacing. All previous recalls and software updates were completed, including the latest ICCU recall (272?) which was completed on December 3. There have now been multiple software updates and recalls targeting this part, but it still resulted in the vehicle losing power and being inoperable.
Our 8-mo old 9800 mile Ioniq 5 failed to maintain its 12v battery while parked for a week. It was dead when we came back to it. Jump started successfully. I replaced the OEM battery with an AGM battery, which the car failed to maintain charge on after 2 weeks. At that time, while driving, the car displayed "Stop vehicle an…
Read full complaint
Our 8-mo old 9800 mile Ioniq 5 failed to maintain its 12v battery while parked for a week. It was dead when we came back to it. Jump started successfully. I replaced the OEM battery with an AGM battery, which the car failed to maintain charge on after 2 weeks. At that time, while driving, the car displayed "Stop vehicle and check power supply" and "check vehicle electrical system." I had a battery monitor installed which showed the car only had 44% charge left in a new 12v battery. By the time we made it to the dealer 15 minutes away, the car was barely above 20% on its battery, and was about to stop on the road. The car has been diagnosed with an ICCU failure and replacement parts are 2+ months backordered. This car appears to brick itself without much warning to the driver -- and clearly Hyundai's software-only recalls are not fixing the root cause of this dangerous safety issue.
NHTSA ODI #11640156
Mileage unknown · Jan 3, 2025
Electrical System
The contact owns a 2024 Hyundai Ioniq 5. The contact received notification of NHTSA Campaign Number: 24V868000 (ELECTRICAL SYSTEM); however, the part to do the recall repair was unavailable. The contact stated that the manufacturer had exceeded a reasonable amount of time for the recall repair. The manufacturer was made aware of…
Read full complaint
The contact owns a 2024 Hyundai Ioniq 5. The contact received notification of NHTSA Campaign Number: 24V868000 (ELECTRICAL SYSTEM); however, the part to do the recall repair was unavailable. The contact stated that the manufacturer had exceeded a reasonable amount of time for the recall repair. The manufacturer was made aware of the issue. The contact had not experienced a failure. Parts distribution disconnect.
NHTSA ODI #11633907
Mileage unknown · Dec 27, 2024
Electrical System
Hyundai has installed faulty 12v batteries in the Ioniq 5 series cars. The OEM battery fails, resulting in an emergency stop or failure to start. Hyundai refuses to acknowledge the faulty batteries, yet the resolution found by numerous consumes to resolve the issue has been to purchase and install the correct 12v battery. Despit…
Read full complaint
Hyundai has installed faulty 12v batteries in the Ioniq 5 series cars. The OEM battery fails, resulting in an emergency stop or failure to start. Hyundai refuses to acknowledge the faulty batteries, yet the resolution found by numerous consumes to resolve the issue has been to purchase and install the correct 12v battery. Despite going to the dealership to seek a remedy, they refused to replace the faulty battery. They asked for the dead car to be towed into them, but Hyundai roadside assistance is unable to have towed a dead EV. 5 times the car died in the first 6 months of ownership. Hundreds if not thousands of US owners online have reported the faulty 12v issue to Hyundai, received no working repairs, and ultimately replaced their batteries at their cost.
Hyundai Motor America (Hyundai) is recalling certain 2023-2024 Ioniq 5 vehicles. The high voltage battery cells may contain misaligned electrodes, which can lead to a fire while parked or driving.
Consequence & remedy
Consequence: A fire increases the risk of injury.
Remedy: Owners are advised to park outside and away from structures and limit their charge to a maximum of 80% until the recall repair is complete. Dealers will replace the high voltage battery system assembly, free of charge. Owner notification letters are expected to be mailed August 31, 2026. Owners may contact Hyundai's customer service at 855-371-9460. Hyundai's number for this recall is 305. Vehicle Identification Numbers (VINs) involved in this recall became searchable on NHTSA.gov on July 3, 2026.
Hyundai Motor America (Hyundai) is recalling certain 2022-2024 IONIQ 5, 2023-2025 IONIQ 6, Genesis GV60, Genesis GV70 "Electrified," and Genesis G80 "Electrified" vehicles. The Integrated Charging Control Unit (ICCU) may become damaged and stop charging the 12-volt battery, which can result in a loss of drive power.
Consequence & remedy
Consequence: A loss of drive power increases the risk of a crash.
Remedy: Dealers will inspect and replace the ICCU and its fuse, as necessary. In addition, dealers will update the ICCU software. All repairs will be performed free of charge. Owner notification letters were mailed December 20, 2024. Owners may contact Hyundai customer service at 1-855-371-9460 or Genesis customer service at 1-844-340-9741. Hyundai's numbers for this recall are 272 (Hyundai) and 025G (Genesis). This recall expands and replaces previous recall number 24V-204. Vehicles previously repaired under recall 24V-204 will need to have the new remedy completed.
Hyundai Motor America (Hyundai) is recalling certain 2022-2024 IONIQ 5, 2023-2025 IONIQ 6, Genesis GV60, Genesis GV70 "Electrified," and Genesis G80 "Electrified" vehicles. The Integrated Charging Control Unit (ICCU) may become damaged and stop charging the 12-volt battery, which can result in a loss of drive power.
Consequence: A loss of drive power increases the risk of a crash.
Remedy: Dealers will inspect and replace the ICCU and its fuse, as necessary. In addition, dealers will update the ICCU software. All repairs will be performed free of charge. Owner notification letters were mailed December 20, 2024. Owners may contact Hyundai customer service at 1-855-371-9460 or Genesis customer service at 1-844-340-9741. Hyundai's numbers for this recall are 272 (Hyundai) and 025G (Genesis). This recall expands and replaces previous recall number 24V-204. Vehicles previously repaired under recall 24V-204 will need to have the new remedy completed.
Electrical SYSTEM:12V/24V/48V Battery
Hyundai Motor America (Hyundai) is recalling certain 2022-2024 IONIQ 5, 2023-2025 IONIQ 6, Genesis GV60, Genesis GV70 "Electrified," and Genesis G80 "Electrified" vehicles. The Integrated Charging Control Unit (ICCU) may become damaged and stop charging the 12-volt battery, which can result in a loss of drive power.
Consequence: A loss of drive power increases the risk of a crash.
Remedy: Dealers will inspect and replace the ICCU and its fuse, as necessary. In addition, dealers will update the ICCU software. All repairs will be performed free of charge. Owner notification letters were mailed December 20, 2024. Owners may contact Hyundai customer service at 1-855-371-9460 or Genesis customer service at 1-844-340-9741. Hyundai's numbers for this recall are 272 (Hyundai) and 025G (Genesis). This recall expands and replaces previous recall number 24V-204. Vehicles previously repaired under recall 24V-204 will need to have the new remedy completed.
Hyundai Motor America (Hyundai) is recalling certain 2022-2024 IONIQ 5, 2023-2024 IONIQ 6, Genesis GV60, Genesis GV70 "Electrified," and Genesis G80 "Electrified" vehicles. The Integrated Charging Control Unit (ICCU) may become damaged and stop charging the 12-Volt battery, which can result in a loss of drive power.
Consequence & remedy
Consequence: A loss of drive power increases the risk of a crash.
Remedy: This recall is replaced by NHTSA recall number 24V-868. Vehicles already repaired under this recall will need to have the new remedy completed. Dealers will inspect and replace the ICCU and its fuse, as necessary. In addition, dealers will update the ICCU software. All repairs will be performed free of charge. Owner notification letters were mailed April 22, 2024. Owners may contact Hyundai customer service at 1-855-371-9460. Hyundai's number for this recall is 257/021G.
Additional source detail variants (2)
Electrical SYSTEM:12V/24V/48V Battery
Hyundai Motor America (Hyundai) is recalling certain 2022-2024 IONIQ 5, 2023-2024 IONIQ 6, Genesis GV60, Genesis GV70 "Electrified," and Genesis G80 "Electrified" vehicles. The Integrated Charging Control Unit (ICCU) may become damaged and stop charging the 12-Volt battery, which can result in a loss of drive power.
Consequence: A loss of drive power increases the risk of a crash.
Remedy: This recall is replaced by NHTSA recall number 24V-868. Vehicles already repaired under this recall will need to have the new remedy completed. Dealers will inspect and replace the ICCU and its fuse, as necessary. In addition, dealers will update the ICCU software. All repairs will be performed free of charge. Owner notification letters were mailed April 22, 2024. Owners may contact Hyundai customer service at 1-855-371-9460. Hyundai's number for this recall is 257/021G.
Hyundai Motor America (Hyundai) is recalling certain 2022-2024 IONIQ 5, 2023-2024 IONIQ 6, Genesis GV60, Genesis GV70 "Electrified," and Genesis G80 "Electrified" vehicles. The Integrated Charging Control Unit (ICCU) may become damaged and stop charging the 12-Volt battery, which can result in a loss of drive power.
Consequence: A loss of drive power increases the risk of a crash.
Remedy: This recall is replaced by NHTSA recall number 24V-868. Vehicles already repaired under this recall will need to have the new remedy completed. Dealers will inspect and replace the ICCU and its fuse, as necessary. In addition, dealers will update the ICCU software. All repairs will be performed free of charge. Owner notification letters were mailed April 22, 2024. Owners may contact Hyundai customer service at 1-855-371-9460. Hyundai's number for this recall is 257/021G.
Model-level recall history does not show whether a particular VIN is affected or has received a repair. Check a VIN with NHTSA ↗
On June 8, 2023, the Office of Defect Investigation (ODI) opened PE23011 to investigate allegations of loss of motor power on model year (MY) 2022 Hyundai Ioniq 5 vehicles. Some consumers reported loss of motor power immediately after a warning lamp illumination or reduction of motive power while the vehicle was in motion. This investigation found that the Integrated Charging Control Unit (ICCU) may be subject to various conditions such as overcurrent, overvoltage induced at the end of charging, and certain thermal loading during operation that can damage its internal components and open the ICCU fuse, resulting in an inability to charge the 12-volt battery. The vehicle could eventually lose all motive power, increasing the risk of a crash. In July 2023, Hyundai issued a service campaign to address certain MY 2022-2023 Ioniq 5 and MY 2023 Ioniq 6 vehicles that may have low 12V auxiliary battery charging occurrences due to an ICCU fault and may set the DTC P1A9096 “DC/DC Converter Input Voltage Sensor Fault”. On March 15, 2024, Hyundai filed Safety Recall 24V-204 for 98,878 MY 2022-2024 Hyundai Ioniq 5 vehicles and MY 2023-2024 Hyundai Ioniq 6, Genesis GV60, Genesis GV70 “Electrified” and Genesis G80 “Electrified” vehicles. The recall remedy provides an inspection, and if necessary, a replacement of the ICCU and the associated fuse. The ICCU software reduces the risk of overcurrent and implements voltage peak reduction at the end of EV battery charging. The recall also includes a software update that revises the electric water pump operational threshold to reduce thermal loading during charging and driving. In view of the recall action being taken by Hyundai, ODI is closing this Preliminary Evaluation. The agency reserves the right to take additional action if warranted by future circumstances. To review the reports cited in the Closing Resume ODI Report Identification Number document, go to NHTSA.gov.
Additional source detail variants (2)
Electrical SYSTEM:12V/24V/48V Battery
On June 8, 2023, the Office of Defect Investigation (ODI) opened PE23011 to investigate allegations of loss of motor power on model year (MY) 2022 Hyundai Ioniq 5 vehicles. Some consumers reported loss of motor power immediately after a warning lamp illumination or reduction of motive power while the vehicle was in motion. This investigation found that the Integrated Charging Control Unit (ICCU) may be subject to various conditions such as overcurrent, overvoltage induced at the end of charging, and certain thermal loading during operation that can damage its internal components and open the ICCU fuse, resulting in an inability to charge the 12-volt battery. The vehicle could eventually lose all motive power, increasing the risk of a crash. In July 2023, Hyundai issued a service campaign to address certain MY 2022-2023 Ioniq 5 and MY 2023 Ioniq 6 vehicles that may have low 12V auxiliary battery charging occurrences due to an ICCU fault and may set the DTC P1A9096 “DC/DC Converter Input Voltage Sensor Fault”. On March 15, 2024, Hyundai filed Safety Recall 24V-204 for 98,878 MY 2022-2024 Hyundai Ioniq 5 vehicles and MY 2023-2024 Hyundai Ioniq 6, Genesis GV60, Genesis GV70 “Electrified” and Genesis G80 “Electrified” vehicles. The recall remedy provides an inspection, and if necessary, a replacement of the ICCU and the associated fuse. The ICCU software reduces the risk of overcurrent and implements voltage peak reduction at the end of EV battery charging. The recall also includes a software update that revises the electric water pump operational threshold to reduce thermal loading during charging and driving. In view of the recall action being taken by Hyundai, ODI is closing this Preliminary Evaluation. The agency reserves the right to take additional action if warranted by future circumstances. To review the reports cited in the Closing Resume ODI Report Identification Number document, go to NHTSA.gov.
On June 8, 2023, the Office of Defect Investigation (ODI) opened PE23011 to investigate allegations of loss of motor power on model year (MY) 2022 Hyundai Ioniq 5 vehicles. Some consumers reported loss of motor power immediately after a warning lamp illumination or reduction of motive power while the vehicle was in motion. This investigation found that the Integrated Charging Control Unit (ICCU) may be subject to various conditions such as overcurrent, overvoltage induced at the end of charging, and certain thermal loading during operation that can damage its internal components and open the ICCU fuse, resulting in an inability to charge the 12-volt battery. The vehicle could eventually lose all motive power, increasing the risk of a crash. In July 2023, Hyundai issued a service campaign to address certain MY 2022-2023 Ioniq 5 and MY 2023 Ioniq 6 vehicles that may have low 12V auxiliary battery charging occurrences due to an ICCU fault and may set the DTC P1A9096 “DC/DC Converter Input Voltage Sensor Fault”. On March 15, 2024, Hyundai filed Safety Recall 24V-204 for 98,878 MY 2022-2024 Hyundai Ioniq 5 vehicles and MY 2023-2024 Hyundai Ioniq 6, Genesis GV60, Genesis GV70 “Electrified” and Genesis G80 “Electrified” vehicles. The recall remedy provides an inspection, and if necessary, a replacement of the ICCU and the associated fuse. The ICCU software reduces the risk of overcurrent and implements voltage peak reduction at the end of EV battery charging. The recall also includes a software update that revises the electric water pump operational threshold to reduce thermal loading during charging and driving. In view of the recall action being taken by Hyundai, ODI is closing this Preliminary Evaluation. The agency reserves the right to take additional action if warranted by future circumstances. To review the reports cited in the Closing Resume ODI Report Identification Number document, go to NHTSA.gov.