← New search

1995 Ford Windstar

Owner reports · Recalls · Investigations

More warning signs than most Windstar years

Owner complaints for the 1995 Ford Windstar are substantially higher than the model-year median of 192.

About this comparison →

When problems were reported

Mileage at the reported incident

Limited mileage data: 223 of 3,326 reports include usable mileage. There isn’t enough coverage to show a useful chart.

NHTSA’s mileage field refers to the reported incident, not necessarily the filing date. This shows report counts, not the likelihood of a failure.

What to inspect

Issues worth paying extra attention to based on owner reports.

  • Engine And Engine Cooling. Review the 1,610 owner reports in this category and discuss these concerns during a pre-purchase inspection. Read reports →
  • Power Train. Review the 875 owner reports in this category and discuss these concerns during a pre-purchase inspection. Read reports →
  • Service Brakes, Hydraulic. Review the 484 owner reports in this category and discuss these concerns during a pre-purchase inspection. Read reports →

NHTSA owner reports · September 18, 2026 snapshot.

134 crash reports49 fire reports72 injury reports

Power Train complaints

875 reports
Clear category filter
Mileage unknown · Jan 8, 1999
Power Train

THERE ARE MANY OTHER PROBLEMS WITH THESE VANS IN ADDITION TO THIS!

NHTSA ODI #702015

Mileage unknown · Jan 6, 1999
Power Train

TRANSMISSION FAILURE.

NHTSA ODI #781784

Mileage unknown · Jan 4, 1999
Power Train

THE TRANSMISSION SLIPES OUT OF GEAR WHILE DRIVING AND WILL NOT SHIFT INTO REVERSE AFTER THE ENGINE GETS WARMED UP.

NHTSA ODI #701848

Mileage unknown · Jan 1, 1999
Power Train

FORD PAID A PORTION OF THE HEAD GASKET REPLACEMENT PRIOR TO THE RECALL. DEALERSHIP CLAIMED THERE WAS NO PROBLEM WITH TRANSMISSION WHEN I INITIALLY DETECTED IT AT 32K MILES. IN LATE NOVEMBER THE VEHICLE WAS SHIFTING FROM FIRST GEAR INTO NEUTRAL ON CITY STREETS, MAKING THE VEHICLE VERY UNSAFE TO DRIVE. FORD WILL NOT ACCEPT RESP…

Read full complaint

FORD PAID A PORTION OF THE HEAD GASKET REPLACEMENT PRIOR TO THE RECALL. DEALERSHIP CLAIMED THERE WAS NO PROBLEM WITH TRANSMISSION WHEN I INITIALLY DETECTED IT AT 32K MILES. IN LATE NOVEMBER THE VEHICLE WAS SHIFTING FROM FIRST GEAR INTO NEUTRAL ON CITY STREETS, MAKING THE VEHICLE VERY UNSAFE TO DRIVE. FORD WILL NOT ACCEPT RESPONSIBILITY ALTHOUGH THEY HAVE PAID THE MAJORITY OF THE BILL, LEAVING ME WITH A BALANCE OF $500.00. FOUR DAYS AFTER THE TRANSMISSION REPLACEMENT THE "CHECK ENGINE" LIGHT CAME ON AGAIN. THIS VEHICLE WAS NOT SAFE FOR ME OR MY CHILDREN.

NHTSA ODI #701783

Mileage unknown · Dec 29, 1998
Power Train

WHILE DRIVING AT 30 MPH LOST POWER AND THE GEAR WON'T MOVE FROM OUT OF SECOND GEAR. CONSUMER DID'NT HAVE ANY PRIOR WARNING AND THE VEHICLE DIED OUT. *AK

NHTSA ODI #832758

Mileage unknown · Dec 29, 1998
Power Train

I WAS STOPPED AT A TRAFFIC LIGHT. THE LIGHT CHANGED FOR ME TO GO AND I PRESSED ON THE GAS. THE RMP'S ON MY DIAL WENT TO 2000 BUT MY CAR DID NOT MOVE. WHILE THIS WAS GOING ON I ALMOST GOT REAR ENDED BY THE GUY BEHIND ME. HE THOUGHT I WAS MOVING SINCE THE BREAK LIGHTS HAD GONE OUT WHEN I HIT THE GAS. I ALSO NOTICED THAT SAME …

Read full complaint

I WAS STOPPED AT A TRAFFIC LIGHT. THE LIGHT CHANGED FOR ME TO GO AND I PRESSED ON THE GAS. THE RMP'S ON MY DIAL WENT TO 2000 BUT MY CAR DID NOT MOVE. WHILE THIS WAS GOING ON I ALMOST GOT REAR ENDED BY THE GUY BEHIND ME. HE THOUGHT I WAS MOVING SINCE THE BREAK LIGHTS HAD GONE OUT WHEN I HIT THE GAS. I ALSO NOTICED THAT SAME DAY THE THE CAR WOULD NOT GO INTO REVERSE RIGHT AWAY. IT WOULD TAKE ABOUT 10 SECONDS BEFORE ENGAGING. I TOOK THE CAR TO JOHN LANCE FORD DEALER SHIP LOCATED AT 23775 CENTER RIDGE ROAD, WESTLAKE, OH 44145, 1-800-642-6463. I FOUND OUT IT WAS THE FORWARD CLUTCH PISTON THAT HAD BROKE. I HAD THE MECHANIC GIVE ME THE PART, THERE IS A CRACK THAT RUNS AROUND 45% OF THE PART. THE MECHANIC ALSO INFORMED ME THAT HE HAS SEEN THIS PROBLEM HAPPEN ON QUIT A FEW 95 WINDSTARS. I ASKED HIS WHAT TYPE OF PART HE REPLACED IT WITH. HE TOLD ME THAT THE OLD PART WAS MADE OUT OF ALUMINUM AND THE NEW PART HE REPLACED IT WITH WAS MADE OF STEEL. HE TOLD ME THAT FORD WAS CHANGING THE PART BECAUSE THE STEEL PART WAS STRONGER. FROM LOOKING AT THE REPAIR BILL IT APPEARS THE NEW PART NUMBER OF THE REPLACED BROKEN ITEM IS F4DZ*7A262*A (PISTON-TRAN FORWARD CLUTCH).

NHTSA ODI #701682

Mileage unknown · Dec 28, 1998
Power Train

NO SUMMARY PROVIDED BY CONSUMER

NHTSA ODI #701662

Mileage unknown · Dec 22, 1998
Power Train

DP 98004 AUTOMATIC TRANSMISSION FAILURE: THE AUTOMATIC TRANSMISSION FAILED WITHOUT WARNING. THE TRANSMISSION LOCKED UP IN SECOND GEAR WITHOUT WARNING. DRIVER WAS ABLE TO GET OFF THE ROAD SAFELY. THE DEALER IS AWARE OF THE PROBLEM. THE TRANSMISSION HAS NOT BEEN REPLACED. *AK

NHTSA ODI #832561

Mileage unknown · Dec 22, 1998
Power Train

THE FORWARD CLUTCH PISTON IS FAILING DUE TO A MANUFACTURING DEFECT. THE TRANSMISSION WILL ENGAGE AND DISENGAGE WHILE DRIVING AT SLOW OR HIGH SPEED MAKING THIS A VERY DANGEROUS SITUATION IN WHICH TO OPERATE THIS VEHICLE. IF THIS TRANSMISSION CONTIUES TO OPERATE IN THIS MANNER ON POOR ROAD CONDITIONS, LOSS OF CONTROL CAN AND WILL …

Read full complaint

THE FORWARD CLUTCH PISTON IS FAILING DUE TO A MANUFACTURING DEFECT. THE TRANSMISSION WILL ENGAGE AND DISENGAGE WHILE DRIVING AT SLOW OR HIGH SPEED MAKING THIS A VERY DANGEROUS SITUATION IN WHICH TO OPERATE THIS VEHICLE. IF THIS TRANSMISSION CONTIUES TO OPERATE IN THIS MANNER ON POOR ROAD CONDITIONS, LOSS OF CONTROL CAN AND WILL RESULT BECAUSE OF THE DEFECTIVE CLUTCH PISTON. A RECALL SHOULD BE ISSUED BY THE FORD MOTOR CO. AND THE DEFECTIVE PISTON SHOULD BE REPLACED WITH A STEEL RATHER THEN THE ORIGINAL LIGHT WEIGHT ALUMINUM COMPONENT.

NHTSA ODI #701525

Mileage unknown · Dec 21, 1998
Power Train

CONSUMER DIDN'T ENTER SUMMARY.

NHTSA ODI #701517

Official recalls

6

09V399000 · Vehicle Speed Control

Oct 13, 2009

FORD IS RECALLING MODEL YEARS 1995-2003 WINDSTAR, 2000-2003 EXCURSION DIESEL, 1993-1997 AND 1999-2003 F-250 SD THROUGH F-550 SD DIESEL, 1992-2003 E-150 THROUGH E-550, 1995-2002 EXPLORER, 1997 AND 2002 MERCURY MOUNTAINEER, 1995-1997 AND 2001-2003 RANGER, AND 1994 F53 VEHICLES EQUIPPED WITH THE TEXAS INSTRUMENTS SPEED CONTROL DEACTIVATION SWITCH (SCDS). THE SCDS MAY LEAK INTERNALLY AND THEN OVERHEAT, SMOKE, OR BURN.

Consequence & remedy

Consequence: A VEHICLE FIRE COULD OCCUR WITH OR WITHOUT THE ENGINE RUNNING.

Remedy: FORD WILL NOTIFY OWNERS THAT DEALERS WILL INSTALL A FUSED WIRING HARNESS IN LINE WITH THE SCDS. ON 1999-2003 WINDSTAR VEHICLES WITH A LEAKING SCDS, DEALERS WILL ALSO INSPECT THE ABS CONTROL MODULE CONNECTOR AND REPAIR AS NECESSARY. REPAIRS WILL BE COMPLETED FREE OF CHARGE. THE SAFETY RECALL BEGAN ON OCTOBER 27, 2009. OWNERS MAY CONTACT FORD AT 1-888-222-2751.

02V101000 · Service Brakes, Hydraulic:foundation Components:hoses, Lines/piping, And Fittings

Apr 4, 2002

ON CERTAIN MINIVANS ORIGINALLY SOLD IN OR CURRENTLY REGISTERED IN THE STATES OF CONNECTICUT, DELAWARE, ILLINOIS, INDIANA, IOWA, MAINE, MARYLAND, MASSACHUSETTS, MICHIGAN, MINNESOTA, MISSOURI, NEW HAMPSHIRE, NEW JERSEY, NEW YORK, OHIO, PENNSYLVANIA, RHODE ISLAND, VERMONT, WEST VIRGINIA, WISCONSIN, AND THE DISTRICT OF COLUMBIA. DURING ASSEMBLY, SOME BRAKE LINES WERE INSTALLED IN A TWISTED POSITION, CAUSING CONTACT WITH THE DASH PANEL INSULATOR ABOVE THE CATALYTIC CONVERTER. THIS CONTACT COULD ABRADE THE BRAKE LINE CORROSION PROTECTION, CONSEQUENTLY, SALT OR WATER ABSORBED IN THE DASH PANEL INSULATOR WOULD PROMOTE CORROSION. THIS CORROSION COULD ULTIMATELY LEAD TO A LEAK IN THE BRAKE LINE.

Consequence & remedy

Consequence: LEAKAGE OF BRAKE FLUID WILL RESULT IN BRAKE LIGHT ACTIVATION. EXTENDED STOPPING DISTANCE COULD ALSO RESULT, INCREASING THE RISK OF A CRASH.

Remedy: DEALERS WILL INSPECT THE BRAKE LINE FOR CORROSION AND CLEARANCE CONDITIONS. A BRAKE LINE THAT IS NOT CORRODED WILL BE REPOSITIONED. A BRAKE LINE THAT IS CORRODED OR LEAKING WILL BE REPLACED WITH A NYLON COATED BRAKE LINE AND SECURED USING THREE RETAINING CLIPS TO ASSURE CLEARANCE FROM THE INSULATOR. OWNER NOTIFICATION BEGAN MAY 10, 2002. OWNERS WHO TAKE THEIR VEHICLES TO AN AUTHORIZED DEALER ON AN AGREED UPON SERVICE DATE AND DO NOT RECEIVE THE FREE REMEDY WITHIN A REASONABLE TIME SHOULD CONTACT FORD AT 1-866-436-7332.

99V309000 · Fuel System, Gasoline:storage:tank Assembly

Nov 2, 1999

VEHICLE DESCRIPTION: MINIVANS WHICH WERE ORIGINALLY SOLD OR CURRENTLY REGISTERED IN THE FOLLOWING HOT WEATHER STATES: ALABAMA, ARIZONA, ARKANSAS, CALIFORNIA (10 SOUTHERN COUNTIES), FLORIDA, GEORGIA, HAWAII, LOUISIANA, MISSISSIPPI, NEVADA (CLARK COUNTY ONLY), OKLAHOMA, SOUTH CAROLINA AND TEXAS, CAN DEVELOP CRACKS IN THE FUEL TANK IN THE FORWARD STRAP AREA OF THE STANDARD 20 GALLON TANK DUE TO A COMBINATION OF FACTORS THAT ARE PRESENT IN CERTAIN VERY HOT AREAS OF THE COUNTRY.

Consequence & remedy

Consequence: THESE CRACKS COULD RESULT IN FUEL LEAKAGE IF THEY PROPAGATE THROUGH THE WALL OF THE TANK.

Remedy: DEALERS WILL INSTALL A BRACE ASSEMBLY AT THE STRAP BOLT HOLE LOCATION AND REPLACE THE TANK STRAP WITH A REVISED, LONGER STRAP. DEALERS WILL ALSO INSPECT THE TANKS FOR LEAKS. IF A LEAK EXISTS AND IS THE RESULT OF A CRACK IN THE FUEL TANK, THE TANK WILL BE REPLACED IN ADDITION TO THE INSTALLATION OF A SPACER AND LONGER STRAP.

97V180000 · Structure:body:hood

Oct 20, 1997

VEHICLE DESCRIPTION: PASSENGER VEHICLES AND MINI VANS. TEARING OF THE BOND BETWEEN THE INNER AND OUTER HOOD PANELS DURING MINOR FRONT END COLLISIONS CAN RESULT IN A GAP AT THE LEADING EDGE OF THE HOOD. AIR FORCED BETWEEN THE INNER AND OUTER PANELS CAN PRODUCE ENOUGH PRESSURE TO FORCE THE OUTER PANEL UPWARD.

Consequence & remedy

Consequence: THIS CONDITION CAN RESULT IN TOTAL SEPARATION OF THE OUTER HOOD PANEL.

Remedy: DEALERS WILL INSPECT THE HOOD AREA FOR ANY DAMAGE ALONG THE LEADING EDGE OF THE HOOD. IF THERE IS ANY EVIDENCE OF BOND SEPARATION, THE HOOD WILL BE REPLACED. IF THERE IS NO EVIDENCE OF BOND SEPARATION, ADDITIONAL ADHESIVE WILL BE APPLIED BETWEEN THE INNER AND OUTER HOOD PANELS.

94V222000 · Electrical System:wiring:front Underhood

Nov 4, 1994

THE WIRING HARNESS INSULATION CAN ABRADE ON A BRACE THAT RUNS FROM THE INSTRUMENT PANEL TO THE COWL.

Consequence & remedy

Consequence: THIS CONDITION CAN RESULT IN AN ELECTRICAL SHORT AND POSSIBLY A VEHICLE FIRE.

Remedy: DEALERS WILL INSTALL A SHIELD ON THE INSTRUMENT PANEL TO COWL BRACE, AND INSTALLATION OF A PIECE OF CONVOLUTE WRAP MATERIAL ON ONE OF THE ADJACENT HARNESSES.

94V223000 · Electrical System:alternator/generator/regulator

Nov 4, 1994

THE ALTERNATOR OUTPUT WIRE WAS NOT CONNECTED TIGHTLY TO THE POWER DISTRIBUTION BOX.

Consequence & remedy

Consequence: THIS CAN RESULT IN OVERHEATING OF THE CONNECTION AND A POSSIBLE VEHICLE FIRE.

Remedy: DEALERS WILL INSPECT AND TIGHTEN THE CONNECTION. VEHICLES WITH VISIBLE DAMAGE TO THE PLASTIC POWER DISTRIBUTION BOX HOUSING WILL HAVE THE THE UNDERHOOD HARNESS, INCLUDING THE POWER DISTRIBUTION BOX, REPLACED.

Model-level recall history does not show whether a particular VIN is affected or has received a repair. Check a VIN with NHTSA ↗

NHTSA investigations

14

EA08021 · Engine Compartment Fires

Opened Sep 17, 2008 · Closed Oct 14, 2009

Status: closed (inferred from source dates) · Electrical System; Electrical System:wiring; Service Brakes, Hydraulic; Service Brakes, Hydraulic:antilock/traction Control/electronic Limited Slip; Service Brakes, Hydraulic:antilock/traction Control/electronic Limited Slip:control Unit/module ; Vehicle Speed Control; Vehicle Speed Control:cruise Control

EA08-021 IS CLOSED WITH FORD'S ACTIONS IN RECALL 09V-399 RECALLING APPROXIMATELY 4.5 MILLION VEHICLES EQUIPPED WITH TEXAS INSTRUMENTS SPEED CONTROL DEACTIVATION SWITCHES (SCDS).WITH THIS RECALL FORD HAS NOW RECALLED ALL OF THE APPROXIMATE 16 MILLION FORD MODEL VEHICLES THAT WERE MANUFACTURED FROM MY 1992 THROUGH 2003 WITH A TEXAS INSTRUMENTS SCDS.NHTSA WILL CONTINUE TO MONITOR THE RECALLED VEHICLES TO ENSURE REMEDIES INSTALLED BY FORD TOMITIGATE THE POTENTIAL FOR SCDS RELATED FIRES ARE EFFECTIVE.THE AGENCY RESERVES THE RIGHT TO TAKE FURTHER ACTION IF WARRANTED BY THE CIRCUMSTANCES.SEE ATTACHED CLOSING REPORT FOR FURTHER DETAILS.

Additional source detail variants (7)

Electrical System

EA08-021 IS CLOSED WITH FORD'S ACTIONS IN RECALL 09V-399 RECALLING APPROXIMATELY 4.5 MILLION VEHICLES EQUIPPED WITH TEXAS INSTRUMENTS SPEED CONTROL DEACTIVATION SWITCHES (SCDS).WITH THIS RECALL FORD HAS NOW RECALLED ALL OF THE APPROXIMATE 16 MILLION FORD MODEL VEHICLES THAT WERE MANUFACTURED FROM MY 1992 THROUGH 2003 WITH A TEXAS INSTRUMENTS SCDS.NHTSA WILL CONTINUE TO MONITOR THE RECALLED VEHICLES TO ENSURE REMEDIES INSTALLED BY FORD TOMITIGATE THE POTENTIAL FOR SCDS RELATED FIRES ARE EFFECTIVE.THE AGENCY RESERVES THE RIGHT TO TAKE FURTHER ACTION IF WARRANTED BY THE CIRCUMSTANCES.SEE ATTACHED CLOSING REPORT FOR FURTHER DETAILS.

Electrical System:wiring

EA08-021 IS CLOSED WITH FORD'S ACTIONS IN RECALL 09V-399 RECALLING APPROXIMATELY 4.5 MILLION VEHICLES EQUIPPED WITH TEXAS INSTRUMENTS SPEED CONTROL DEACTIVATION SWITCHES (SCDS).WITH THIS RECALL FORD HAS NOW RECALLED ALL OF THE APPROXIMATE 16 MILLION FORD MODEL VEHICLES THAT WERE MANUFACTURED FROM MY 1992 THROUGH 2003 WITH A TEXAS INSTRUMENTS SCDS.NHTSA WILL CONTINUE TO MONITOR THE RECALLED VEHICLES TO ENSURE REMEDIES INSTALLED BY FORD TOMITIGATE THE POTENTIAL FOR SCDS RELATED FIRES ARE EFFECTIVE.THE AGENCY RESERVES THE RIGHT TO TAKE FURTHER ACTION IF WARRANTED BY THE CIRCUMSTANCES.SEE ATTACHED CLOSING REPORT FOR FURTHER DETAILS.

Service Brakes, Hydraulic:antilock/traction Control/electronic Limited Slip:control Unit/module

EA08-021 IS CLOSED WITH FORD'S ACTIONS IN RECALL 09V-399 RECALLING APPROXIMATELY 4.5 MILLION VEHICLES EQUIPPED WITH TEXAS INSTRUMENTS SPEED CONTROL DEACTIVATION SWITCHES (SCDS).WITH THIS RECALL FORD HAS NOW RECALLED ALL OF THE APPROXIMATE 16 MILLION FORD MODEL VEHICLES THAT WERE MANUFACTURED FROM MY 1992 THROUGH 2003 WITH A TEXAS INSTRUMENTS SCDS.NHTSA WILL CONTINUE TO MONITOR THE RECALLED VEHICLES TO ENSURE REMEDIES INSTALLED BY FORD TOMITIGATE THE POTENTIAL FOR SCDS RELATED FIRES ARE EFFECTIVE.THE AGENCY RESERVES THE RIGHT TO TAKE FURTHER ACTION IF WARRANTED BY THE CIRCUMSTANCES.SEE ATTACHED CLOSING REPORT FOR FURTHER DETAILS.

Service Brakes, Hydraulic:antilock/traction Control/electronic Limited Slip

EA08-021 IS CLOSED WITH FORD'S ACTIONS IN RECALL 09V-399 RECALLING APPROXIMATELY 4.5 MILLION VEHICLES EQUIPPED WITH TEXAS INSTRUMENTS SPEED CONTROL DEACTIVATION SWITCHES (SCDS).WITH THIS RECALL FORD HAS NOW RECALLED ALL OF THE APPROXIMATE 16 MILLION FORD MODEL VEHICLES THAT WERE MANUFACTURED FROM MY 1992 THROUGH 2003 WITH A TEXAS INSTRUMENTS SCDS.NHTSA WILL CONTINUE TO MONITOR THE RECALLED VEHICLES TO ENSURE REMEDIES INSTALLED BY FORD TOMITIGATE THE POTENTIAL FOR SCDS RELATED FIRES ARE EFFECTIVE.THE AGENCY RESERVES THE RIGHT TO TAKE FURTHER ACTION IF WARRANTED BY THE CIRCUMSTANCES.SEE ATTACHED CLOSING REPORT FOR FURTHER DETAILS.

Service Brakes, Hydraulic

EA08-021 IS CLOSED WITH FORD'S ACTIONS IN RECALL 09V-399 RECALLING APPROXIMATELY 4.5 MILLION VEHICLES EQUIPPED WITH TEXAS INSTRUMENTS SPEED CONTROL DEACTIVATION SWITCHES (SCDS).WITH THIS RECALL FORD HAS NOW RECALLED ALL OF THE APPROXIMATE 16 MILLION FORD MODEL VEHICLES THAT WERE MANUFACTURED FROM MY 1992 THROUGH 2003 WITH A TEXAS INSTRUMENTS SCDS.NHTSA WILL CONTINUE TO MONITOR THE RECALLED VEHICLES TO ENSURE REMEDIES INSTALLED BY FORD TOMITIGATE THE POTENTIAL FOR SCDS RELATED FIRES ARE EFFECTIVE.THE AGENCY RESERVES THE RIGHT TO TAKE FURTHER ACTION IF WARRANTED BY THE CIRCUMSTANCES.SEE ATTACHED CLOSING REPORT FOR FURTHER DETAILS.

Vehicle Speed Control:cruise Control

EA08-021 IS CLOSED WITH FORD'S ACTIONS IN RECALL 09V-399 RECALLING APPROXIMATELY 4.5 MILLION VEHICLES EQUIPPED WITH TEXAS INSTRUMENTS SPEED CONTROL DEACTIVATION SWITCHES (SCDS).WITH THIS RECALL FORD HAS NOW RECALLED ALL OF THE APPROXIMATE 16 MILLION FORD MODEL VEHICLES THAT WERE MANUFACTURED FROM MY 1992 THROUGH 2003 WITH A TEXAS INSTRUMENTS SCDS.NHTSA WILL CONTINUE TO MONITOR THE RECALLED VEHICLES TO ENSURE REMEDIES INSTALLED BY FORD TOMITIGATE THE POTENTIAL FOR SCDS RELATED FIRES ARE EFFECTIVE.THE AGENCY RESERVES THE RIGHT TO TAKE FURTHER ACTION IF WARRANTED BY THE CIRCUMSTANCES.SEE ATTACHED CLOSING REPORT FOR FURTHER DETAILS.

Vehicle Speed Control

EA08-021 IS CLOSED WITH FORD'S ACTIONS IN RECALL 09V-399 RECALLING APPROXIMATELY 4.5 MILLION VEHICLES EQUIPPED WITH TEXAS INSTRUMENTS SPEED CONTROL DEACTIVATION SWITCHES (SCDS).WITH THIS RECALL FORD HAS NOW RECALLED ALL OF THE APPROXIMATE 16 MILLION FORD MODEL VEHICLES THAT WERE MANUFACTURED FROM MY 1992 THROUGH 2003 WITH A TEXAS INSTRUMENTS SCDS.NHTSA WILL CONTINUE TO MONITOR THE RECALLED VEHICLES TO ENSURE REMEDIES INSTALLED BY FORD TOMITIGATE THE POTENTIAL FOR SCDS RELATED FIRES ARE EFFECTIVE.THE AGENCY RESERVES THE RIGHT TO TAKE FURTHER ACTION IF WARRANTED BY THE CIRCUMSTANCES.SEE ATTACHED CLOSING REPORT FOR FURTHER DETAILS.

PE08035 · Engine Compartment Fires

Opened May 13, 2008 · Closed Sep 17, 2008

Status: closed (inferred from source dates) · Electrical System; Electrical System:wiring; Vehicle Speed Control

ODI HAS RECEIVED 134 CONSUMER COMPLAINTS, 285 MANUFACTURER COMPLAINTS, AND 137 MANUFACTURER WARRANTY CLAIMS ALLEGING INCIDENTS OF ENGINE COMPARTMENT FIRE IN MODEL YEAR (MY) 1995 THRU 2003 FORD WINDSTAR VEHICLES.TWO OF THE ODI COMPLAINTS ALLEGE THE FIRES CAUSED STRUCTURAL DAMAGE TO THE COMPLAINANT'S HOME.OF THE 134 ODI COMPLAINTS, 36 ALLEGE THE FIRE OCCURRED WHILE THE VEHICLE WAS PARKED, 72 ALLEGE THE FIRE OCCURRED WHILE THE VEHICLE WAS RUNNING AND 26 OF THE COMPLAINTS DO NOT SPECIFY IF THE VEHICLE WAS RUNNING OR NOT.FURTHER REVIEW OF THE ODI COMPLAINTS SHOWS THAT 72 ALLEGE THAT THE SPEED CONTROL DEACTIVATION SWITCH (SCDS) CAUSED THE FIRE AND 10 ALLEGE THAT THE SCDS LEAKED BRAKE FLUID ON TO THE ABS MODULE RESULTING IN THE FIRE.THERE WERE 52 THAT DID NOT IDENTIFY A CAUSE OR THAT IDENTIFIED MISCELLANEOUS OTHER CAUSES.ODI HAS ALSO RECEIVED 89 COMPLAINTS ( NOT COUNTED IN THIS RESUME) ALLEGING THAT THE SCDS DEVELOPED A BRAKE FLUID LEAK.THIRTEEN OF THESE COMPLAINTS SAY THAT THE LEAK AT THE SCDS RESULTED IN BRAKED FLUID REACHING THE ABS MODULE.THIS PE HAS BEEN UPGRADED TO AN ENGINEERING ANALYSIS (EA) TO FURTHER EVALUATE THE CAUSE OF THE FIRES AND ASSESS THE SCOPE, FREQUENCY, AND SAFETY CONSEQUENCES OF THE ALLEGED DEFECT.

Additional source detail variants (3)

Electrical System

ODI HAS RECEIVED 134 CONSUMER COMPLAINTS, 285 MANUFACTURER COMPLAINTS, AND 137 MANUFACTURER WARRANTY CLAIMS ALLEGING INCIDENTS OF ENGINE COMPARTMENT FIRE IN MODEL YEAR (MY) 1995 THRU 2003 FORD WINDSTAR VEHICLES.TWO OF THE ODI COMPLAINTS ALLEGE THE FIRES CAUSED STRUCTURAL DAMAGE TO THE COMPLAINANT'S HOME.OF THE 134 ODI COMPLAINTS, 36 ALLEGE THE FIRE OCCURRED WHILE THE VEHICLE WAS PARKED, 72 ALLEGE THE FIRE OCCURRED WHILE THE VEHICLE WAS RUNNING AND 26 OF THE COMPLAINTS DO NOT SPECIFY IF THE VEHICLE WAS RUNNING OR NOT.FURTHER REVIEW OF THE ODI COMPLAINTS SHOWS THAT 72 ALLEGE THAT THE SPEED CONTROL DEACTIVATION SWITCH (SCDS) CAUSED THE FIRE AND 10 ALLEGE THAT THE SCDS LEAKED BRAKE FLUID ON TO THE ABS MODULE RESULTING IN THE FIRE.THERE WERE 52 THAT DID NOT IDENTIFY A CAUSE OR THAT IDENTIFIED MISCELLANEOUS OTHER CAUSES.ODI HAS ALSO RECEIVED 89 COMPLAINTS ( NOT COUNTED IN THIS RESUME) ALLEGING THAT THE SCDS DEVELOPED A BRAKE FLUID LEAK.THIRTEEN OF THESE COMPLAINTS SAY THAT THE LEAK AT THE SCDS RESULTED IN BRAKED FLUID REACHING THE ABS MODULE.THIS PE HAS BEEN UPGRADED TO AN ENGINEERING ANALYSIS (EA) TO FURTHER EVALUATE THE CAUSE OF THE FIRES AND ASSESS THE SCOPE, FREQUENCY, AND SAFETY CONSEQUENCES OF THE ALLEGED DEFECT.

Electrical System:wiring

ODI HAS RECEIVED 134 CONSUMER COMPLAINTS, 285 MANUFACTURER COMPLAINTS, AND 137 MANUFACTURER WARRANTY CLAIMS ALLEGING INCIDENTS OF ENGINE COMPARTMENT FIRE IN MODEL YEAR (MY) 1995 THRU 2003 FORD WINDSTAR VEHICLES.TWO OF THE ODI COMPLAINTS ALLEGE THE FIRES CAUSED STRUCTURAL DAMAGE TO THE COMPLAINANT'S HOME.OF THE 134 ODI COMPLAINTS, 36 ALLEGE THE FIRE OCCURRED WHILE THE VEHICLE WAS PARKED, 72 ALLEGE THE FIRE OCCURRED WHILE THE VEHICLE WAS RUNNING AND 26 OF THE COMPLAINTS DO NOT SPECIFY IF THE VEHICLE WAS RUNNING OR NOT.FURTHER REVIEW OF THE ODI COMPLAINTS SHOWS THAT 72 ALLEGE THAT THE SPEED CONTROL DEACTIVATION SWITCH (SCDS) CAUSED THE FIRE AND 10 ALLEGE THAT THE SCDS LEAKED BRAKE FLUID ON TO THE ABS MODULE RESULTING IN THE FIRE.THERE WERE 52 THAT DID NOT IDENTIFY A CAUSE OR THAT IDENTIFIED MISCELLANEOUS OTHER CAUSES.ODI HAS ALSO RECEIVED 89 COMPLAINTS ( NOT COUNTED IN THIS RESUME) ALLEGING THAT THE SCDS DEVELOPED A BRAKE FLUID LEAK.THIRTEEN OF THESE COMPLAINTS SAY THAT THE LEAK AT THE SCDS RESULTED IN BRAKED FLUID REACHING THE ABS MODULE.THIS PE HAS BEEN UPGRADED TO AN ENGINEERING ANALYSIS (EA) TO FURTHER EVALUATE THE CAUSE OF THE FIRES AND ASSESS THE SCOPE, FREQUENCY, AND SAFETY CONSEQUENCES OF THE ALLEGED DEFECT.

Vehicle Speed Control

ODI HAS RECEIVED 134 CONSUMER COMPLAINTS, 285 MANUFACTURER COMPLAINTS, AND 137 MANUFACTURER WARRANTY CLAIMS ALLEGING INCIDENTS OF ENGINE COMPARTMENT FIRE IN MODEL YEAR (MY) 1995 THRU 2003 FORD WINDSTAR VEHICLES.TWO OF THE ODI COMPLAINTS ALLEGE THE FIRES CAUSED STRUCTURAL DAMAGE TO THE COMPLAINANT'S HOME.OF THE 134 ODI COMPLAINTS, 36 ALLEGE THE FIRE OCCURRED WHILE THE VEHICLE WAS PARKED, 72 ALLEGE THE FIRE OCCURRED WHILE THE VEHICLE WAS RUNNING AND 26 OF THE COMPLAINTS DO NOT SPECIFY IF THE VEHICLE WAS RUNNING OR NOT.FURTHER REVIEW OF THE ODI COMPLAINTS SHOWS THAT 72 ALLEGE THAT THE SPEED CONTROL DEACTIVATION SWITCH (SCDS) CAUSED THE FIRE AND 10 ALLEGE THAT THE SCDS LEAKED BRAKE FLUID ON TO THE ABS MODULE RESULTING IN THE FIRE.THERE WERE 52 THAT DID NOT IDENTIFY A CAUSE OR THAT IDENTIFIED MISCELLANEOUS OTHER CAUSES.ODI HAS ALSO RECEIVED 89 COMPLAINTS ( NOT COUNTED IN THIS RESUME) ALLEGING THAT THE SCDS DEVELOPED A BRAKE FLUID LEAK.THIRTEEN OF THESE COMPLAINTS SAY THAT THE LEAK AT THE SCDS RESULTED IN BRAKED FLUID REACHING THE ABS MODULE.THIS PE HAS BEEN UPGRADED TO AN ENGINEERING ANALYSIS (EA) TO FURTHER EVALUATE THE CAUSE OF THE FIRES AND ASSESS THE SCOPE, FREQUENCY, AND SAFETY CONSEQUENCES OF THE ALLEGED DEFECT.

RQ04003 · Hydraulic Brake Line Failure

Opened May 27, 2004 · Closed Oct 7, 2004

Status: closed (inferred from source dates) · Service Brakes, Hydraulic; Service Brakes, Hydraulic:fluid; Service Brakes, Hydraulic:foundation Components:hoses, Lines/piping, And Fittings

ON APRIL 4, 2002, FORD MOTOR COMPANY NOTIFIED ODI OF A DEFECT CONDITION THAT COULD RESULT IN EXTENDED STOPPING DISTANCES IN APPROXIMATELY 250 THOUSAND MODEL YEAR (MY) 1995 AND 1996 WINDSTAR MINIVANS SOLD OR REGISTERED IN SALT BELT STATES (RECALL 02V-101).ACCORDING TO FORD, IMPROPER BRAKE LINE ROUTING IN VEHICLES MANUFACTURED AT THE OAKVILLE ASSEMBLY PLANT FROM JANUARY 14, 1994 THROUGH MAY 21, 1996 RESULTED IN SOME VEHICLES WITH MIS-POSITIONED BRAKE LINES THAT COULD CONTACT A DASH PANEL INSULATOR.SUCH CONTACT COULD ABRADE THE BRAKE LINE PROTECTION COATING AND RESULT IN CORROSIVE FAILURE OF THE BRAKE LINES. ODI OPENED RQ04-003 TO INVESTIGATE COMPLAINTS OF BRAKE LINE FAILURE IN WINDSTAR VEHICLES THAT WERE:(1) LOCATED OUTSIDE THE RECALL REGION; OR (2) BUILT AFTER THE RECALL RANGE.REGARDING THE LATTER GROUP, FORD CHANGED THE ASSEMBLY PROCESS AFTER MAY 21, 1996 TO ELIMINATE THE MIS-BUILD PROBLEM.THE FAILURE RATES IN THE MY 1996 WINDSTAR VEHICLES BUILT AFTER THE PROCESS CHANGE ARE RELATIVELY LOW IN BOTH THE SALT-BELT STATES. WITH RESPECT TO THE MY 1995 AND 1996 VEHICLES BUILT DURING THE PERIOD OF CONCERN THAT WERE NOT SOLD OR REGISTERED IN SALT BELT STATES, THE FAILURE RATE IS ALSO LOW.THE RELATED BRAKE LINE WARRANTY CLAIM RATE FOR THOSE VEHICLES IS ALSO LOW. ACCORDINGLY, A SAFETY-RELATED DEFECT TREND HAS NOT BEEN IDENTIFIED IN THE MY 1995-96 WINDSTAR VEHICLES THAT WERE NOT INCLUDED IN RECALL 02V-101.FURTHER USE OF AGENCY RESOURCES DOES NOT APPEAR TO BE WARRANTED.THE CLOSING OF THIS INVESTIGATION DOES NOT CONSTITUTE A FINDING BY NHTSA THAT NO SAFETY-RELATED DEFECT EXISTS.THE AGENCY RESERVES THE RIGHT TO TAKE FURTHER ACTION IF WARRANTED BY THE CIRCUMSTANCES.

Additional source detail variants (3)

Service Brakes, Hydraulic:fluid

ON APRIL 4, 2002, FORD MOTOR COMPANY NOTIFIED ODI OF A DEFECT CONDITION THAT COULD RESULT IN EXTENDED STOPPING DISTANCES IN APPROXIMATELY 250 THOUSAND MODEL YEAR (MY) 1995 AND 1996 WINDSTAR MINIVANS SOLD OR REGISTERED IN SALT BELT STATES (RECALL 02V-101).ACCORDING TO FORD, IMPROPER BRAKE LINE ROUTING IN VEHICLES MANUFACTURED AT THE OAKVILLE ASSEMBLY PLANT FROM JANUARY 14, 1994 THROUGH MAY 21, 1996 RESULTED IN SOME VEHICLES WITH MIS-POSITIONED BRAKE LINES THAT COULD CONTACT A DASH PANEL INSULATOR.SUCH CONTACT COULD ABRADE THE BRAKE LINE PROTECTION COATING AND RESULT IN CORROSIVE FAILURE OF THE BRAKE LINES. ODI OPENED RQ04-003 TO INVESTIGATE COMPLAINTS OF BRAKE LINE FAILURE IN WINDSTAR VEHICLES THAT WERE:(1) LOCATED OUTSIDE THE RECALL REGION; OR (2) BUILT AFTER THE RECALL RANGE.REGARDING THE LATTER GROUP, FORD CHANGED THE ASSEMBLY PROCESS AFTER MAY 21, 1996 TO ELIMINATE THE MIS-BUILD PROBLEM.THE FAILURE RATES IN THE MY 1996 WINDSTAR VEHICLES BUILT AFTER THE PROCESS CHANGE ARE RELATIVELY LOW IN BOTH THE SALT-BELT STATES. WITH RESPECT TO THE MY 1995 AND 1996 VEHICLES BUILT DURING THE PERIOD OF CONCERN THAT WERE NOT SOLD OR REGISTERED IN SALT BELT STATES, THE FAILURE RATE IS ALSO LOW.THE RELATED BRAKE LINE WARRANTY CLAIM RATE FOR THOSE VEHICLES IS ALSO LOW. ACCORDINGLY, A SAFETY-RELATED DEFECT TREND HAS NOT BEEN IDENTIFIED IN THE MY 1995-96 WINDSTAR VEHICLES THAT WERE NOT INCLUDED IN RECALL 02V-101.FURTHER USE OF AGENCY RESOURCES DOES NOT APPEAR TO BE WARRANTED.THE CLOSING OF THIS INVESTIGATION DOES NOT CONSTITUTE A FINDING BY NHTSA THAT NO SAFETY-RELATED DEFECT EXISTS.THE AGENCY RESERVES THE RIGHT TO TAKE FURTHER ACTION IF WARRANTED BY THE CIRCUMSTANCES.

Service Brakes, Hydraulic

ON APRIL 4, 2002, FORD MOTOR COMPANY NOTIFIED ODI OF A DEFECT CONDITION THAT COULD RESULT IN EXTENDED STOPPING DISTANCES IN APPROXIMATELY 250 THOUSAND MODEL YEAR (MY) 1995 AND 1996 WINDSTAR MINIVANS SOLD OR REGISTERED IN SALT BELT STATES (RECALL 02V-101).ACCORDING TO FORD, IMPROPER BRAKE LINE ROUTING IN VEHICLES MANUFACTURED AT THE OAKVILLE ASSEMBLY PLANT FROM JANUARY 14, 1994 THROUGH MAY 21, 1996 RESULTED IN SOME VEHICLES WITH MIS-POSITIONED BRAKE LINES THAT COULD CONTACT A DASH PANEL INSULATOR.SUCH CONTACT COULD ABRADE THE BRAKE LINE PROTECTION COATING AND RESULT IN CORROSIVE FAILURE OF THE BRAKE LINES. ODI OPENED RQ04-003 TO INVESTIGATE COMPLAINTS OF BRAKE LINE FAILURE IN WINDSTAR VEHICLES THAT WERE:(1) LOCATED OUTSIDE THE RECALL REGION; OR (2) BUILT AFTER THE RECALL RANGE.REGARDING THE LATTER GROUP, FORD CHANGED THE ASSEMBLY PROCESS AFTER MAY 21, 1996 TO ELIMINATE THE MIS-BUILD PROBLEM.THE FAILURE RATES IN THE MY 1996 WINDSTAR VEHICLES BUILT AFTER THE PROCESS CHANGE ARE RELATIVELY LOW IN BOTH THE SALT-BELT STATES. WITH RESPECT TO THE MY 1995 AND 1996 VEHICLES BUILT DURING THE PERIOD OF CONCERN THAT WERE NOT SOLD OR REGISTERED IN SALT BELT STATES, THE FAILURE RATE IS ALSO LOW.THE RELATED BRAKE LINE WARRANTY CLAIM RATE FOR THOSE VEHICLES IS ALSO LOW. ACCORDINGLY, A SAFETY-RELATED DEFECT TREND HAS NOT BEEN IDENTIFIED IN THE MY 1995-96 WINDSTAR VEHICLES THAT WERE NOT INCLUDED IN RECALL 02V-101.FURTHER USE OF AGENCY RESOURCES DOES NOT APPEAR TO BE WARRANTED.THE CLOSING OF THIS INVESTIGATION DOES NOT CONSTITUTE A FINDING BY NHTSA THAT NO SAFETY-RELATED DEFECT EXISTS.THE AGENCY RESERVES THE RIGHT TO TAKE FURTHER ACTION IF WARRANTED BY THE CIRCUMSTANCES.

Service Brakes, Hydraulic:foundation Components:hoses, Lines/piping, And Fittings

ON APRIL 4, 2002, FORD MOTOR COMPANY NOTIFIED ODI OF A DEFECT CONDITION THAT COULD RESULT IN EXTENDED STOPPING DISTANCES IN APPROXIMATELY 250 THOUSAND MODEL YEAR (MY) 1995 AND 1996 WINDSTAR MINIVANS SOLD OR REGISTERED IN SALT BELT STATES (RECALL 02V-101).ACCORDING TO FORD, IMPROPER BRAKE LINE ROUTING IN VEHICLES MANUFACTURED AT THE OAKVILLE ASSEMBLY PLANT FROM JANUARY 14, 1994 THROUGH MAY 21, 1996 RESULTED IN SOME VEHICLES WITH MIS-POSITIONED BRAKE LINES THAT COULD CONTACT A DASH PANEL INSULATOR.SUCH CONTACT COULD ABRADE THE BRAKE LINE PROTECTION COATING AND RESULT IN CORROSIVE FAILURE OF THE BRAKE LINES. ODI OPENED RQ04-003 TO INVESTIGATE COMPLAINTS OF BRAKE LINE FAILURE IN WINDSTAR VEHICLES THAT WERE:(1) LOCATED OUTSIDE THE RECALL REGION; OR (2) BUILT AFTER THE RECALL RANGE.REGARDING THE LATTER GROUP, FORD CHANGED THE ASSEMBLY PROCESS AFTER MAY 21, 1996 TO ELIMINATE THE MIS-BUILD PROBLEM.THE FAILURE RATES IN THE MY 1996 WINDSTAR VEHICLES BUILT AFTER THE PROCESS CHANGE ARE RELATIVELY LOW IN BOTH THE SALT-BELT STATES. WITH RESPECT TO THE MY 1995 AND 1996 VEHICLES BUILT DURING THE PERIOD OF CONCERN THAT WERE NOT SOLD OR REGISTERED IN SALT BELT STATES, THE FAILURE RATE IS ALSO LOW.THE RELATED BRAKE LINE WARRANTY CLAIM RATE FOR THOSE VEHICLES IS ALSO LOW. ACCORDINGLY, A SAFETY-RELATED DEFECT TREND HAS NOT BEEN IDENTIFIED IN THE MY 1995-96 WINDSTAR VEHICLES THAT WERE NOT INCLUDED IN RECALL 02V-101.FURTHER USE OF AGENCY RESOURCES DOES NOT APPEAR TO BE WARRANTED.THE CLOSING OF THIS INVESTIGATION DOES NOT CONSTITUTE A FINDING BY NHTSA THAT NO SAFETY-RELATED DEFECT EXISTS.THE AGENCY RESERVES THE RIGHT TO TAKE FURTHER ACTION IF WARRANTED BY THE CIRCUMSTANCES.

RQ02011 · Fuel Tank Fatigue Cracking

Opened Aug 29, 2002 · Closed Mar 14, 2003

Status: closed (inferred from source dates) · Fuel System, Gasoline:storage:tank Assembly

SEE ATTACHED REPORT.

EA00027 · Suspension Coil Spring Breakage

Opened Dec 8, 2000 · Closed Jul 31, 2001

Status: closed (inferred from source dates) · Suspension

There is no summary currently available

Additional source detail variants (2)

Suspension

There is no summary currently available

Suspension

There is no summary currently available

PE00024 · Suspension Coil Spring Breakage

Opened Jun 23, 2000 · Closed Dec 8, 2000

Status: closed (inferred from source dates) · Suspension

There is no summary currently available

EA99020 · Fuel Tank Cracks

Opened Jul 26, 1999 · Closed Dec 16, 1999

Status: closed (inferred from source dates) · Fuel System, Gasoline

There is no summary currently available

PE99025 · Fuel Tank Cracks

Opened Apr 15, 1999 · Closed Jul 26, 1999

Status: closed (inferred from source dates) · Fuel System, Gasoline

There is no summary currently available

PE98056 · Rear Axle Trailing Arm

Opened Oct 28, 1998 · Closed Feb 24, 1999

Status: closed (inferred from source dates) · Service Brakes, Hydraulic

There is no summary currently available

DP98004 · Automatic Transmission Failure

Opened May 18, 1998 · Closed Jul 2, 1998

Status: closed (inferred from source dates) · Power Train

There is no summary currently available

EA97018 · Outer Hood Panel Detachment

Opened Sep 30, 1997 · Closed Oct 22, 1997

Status: closed (inferred from source dates) · Structure

There is no summary currently available

PE97011 · Outer Hood Panel Detachment

Opened Mar 13, 1997 · Closed Sep 30, 1997

Status: closed (inferred from source dates) · Structure

THE OFFICE OF DEFECTS INVESTIGATION HAS RECEIVED 6 REPORTS INDICATING THE OUTER HOOD PANEL SEPARATED FROM THE VEHICLES AS THEY WERE BEING DRIVEN.FORD HAS PROVIDE 39 ADDITIONAL REPORTS THAT ARE CONSISTENT WITH ODI REPORTS.FORD INDICATES THAT THE LIKELY CAUSE IS PRIOR COLLISION DAMAGE.THIS INVESTIGATION IS BEING UPGRADED TO FURTHER STUDY THIS ISSUE.

EA96026 · Brake Pedal Fade/extended Stop Distance

Opened Oct 31, 1996 · Closed Feb 18, 2000

Status: closed (inferred from source dates) · Service Brakes, Hydraulic

There is no summary currently available

PE96042 · Brake Pedal Fade/extended Stopping

Opened Jun 13, 1996 · Closed Oct 31, 1996

Status: closed (inferred from source dates) · Service Brakes, Hydraulic

ODI HAS RECEIVED SIXTY-EIGHT (68) CONSUMER REPORTS OF ALLEGED FAILURES OR MALFUNCTIONS IN THE BRAKE SYSTEM ON CERTAIN 1995 AND 1996 FORD WINDSTARS, WHICH RESULTED IN BRAKE PEDAL FADE AND IN EXTENDED STOPPING DISTANCES DURING BRAKINGTHESE ALLEGED FAILURES OR MALFUNCTIONS ARE REPORTED TO HAVE CAUSED TWELVE (12) ACCIDENTS THAT RESULTED FROM VEHICLE LOSS OF BRAKING.THE CONPLAINANTS REPORT THAT THE LOSS OF BRAKING OCCURRED DURINGBRAKING SITUATIONS ON DRY ROADS AS WELL AS ON WET OR SLIPPERY ROADS.IN RESPONSE TO ODI'S INFORMATION REQUES (IR) CONCERNING THE LONG STOPPING DISTANCE COMPLAINTS ON THE 1995 WINDSTAR, FORD REPORTED RECEIVING 259 REPORT (FIELD REPORTS, OWNER COMPLAINTS, AND SUBROGATION CLAIMS) OF LONG STOPPING DISTANCE ON THE 1995 FORD WINDSTAR, ALONG WITH 64 REPORTS OF ACCIDENTS.IN ADDITION, FORD REPORTED RECEIVING SOME 64,000 WARRANTY CLAIMS THAT COULD RELATE TO THE ALLEGED DEFECT OF LONG STOPPING DISTANCE PERFORMANCE ON THE SUBJECT VEHICLES.SINCE APRELIMINARY EVALUATION WAS OPENED, ODI HAS RECEIVED ADDITIONAL COMPLAINTS OF THE ALLEGED FAILURE ON THE 1996 MODELS, WHICH WERE NOT INCLUDED INITIALLY IN THIS INVESTIGATION.ODI BELIEVES THAT AN ENGINEERING ANALYSIS ON THE 1995 AND 1996 FORD WINDSTAR VEHICES IN WARRANTED TO DETERMINE THE SCOPE OF THE PROBLEM.