NHTSA owner reports · September 18, 2026 snapshot.
Power Train complaints
875 reportsClear category filterMileage unknown · Jun 20, 2001
Engine And Engine CoolingPower Train
HAD MINOR COOLANT LEAK, TURNED OUT TO BE "FORD PROGRAM" ENGINE REPLACEMENT. JUST OVER 100 MILES LATER, TRANSMISSION FLUID ALL LEAKED OUT. DEALER CLAIMS UNRELATED TO ENGINE PROBLEM. NEVER HAD TRANSMISSION PROBLEM PRIOR TO ENGINE BEING REMOVED. TRANS WAS INSPECTED AS PART OF AAA SAFETY INSPECTION WHEN VAN WAS IN FOR ENGINE RE…
Read full complaint
HAD MINOR COOLANT LEAK, TURNED OUT TO BE "FORD PROGRAM" ENGINE REPLACEMENT. JUST OVER 100 MILES LATER, TRANSMISSION FLUID ALL LEAKED OUT. DEALER CLAIMS UNRELATED TO ENGINE PROBLEM. NEVER HAD TRANSMISSION PROBLEM PRIOR TO ENGINE BEING REMOVED. TRANS WAS INSPECTED AS PART OF AAA SAFETY INSPECTION WHEN VAN WAS IN FOR ENGINE REPLACEMENT. SOME SORT OF SEAL LEAK, VAN STILL IN SHOP--HAVING TRANS REBUILT. NO PROBLEM BEFORE ENGINE ISSUE, MAJOR PROBLEM 7 DAYS LATER. FORD SHOULD PAY FOR THE TRANS SINCE IT IS A KNOWN PROBLEM, AND IF THEY DID NOT HAVE TO RIP THE ENGINE OUT, TAKE OFF THAT TRANS AND PUT NEW ENGINE ON, I PROBABLY WOULD BE DRIVING THE WINDSTAR TODAY. WE HAVE HAD REGULAR SERVICE, SPENT OVER $90 TO HAVE TRANS CHECKED LAST YEAR SO THAT THE VEHICLE WOULD LAST US. FORD WAS E-MAILED WHEN WE GOT THE VAN BACK FROM THE ENGINE REPLACEMENT BECAUSE NOT EVERYTHING WAS WORKING PROPERLY. E-MAILED A FEW HOURS LATER WHEN THE TRANS FLUID POURED OUT AND OTHER THAN THE AUTOMATIC RESPONSE SAYING THEY REC'D MY E-MAIL, I HAVE HEARD NOT ONE WORD FROM THEM. NOT MUCH FOR CUSTOMER ASSISTANCE! THE TRANS AND ENGINE ARE RELATED, AND I DO NOT KNOW HOW FORD CAN SAY THEY ARE NOT. NO PROBLEM BEFORE THEY RECONFIGURED UNDER HOOD TO PUT DIFFERENT SHAPE/SIZE ENGINE IN, PROBLEM AFTER.
NHTSA ODI #747144
Mileage unknown · Jun 19, 2001
Engine And Engine CoolingFuel System, GasolinePower Train
WITHIN 97,000 MILES TRANSMISSION HAS MALFUNCTIONED, REVERSE POSITION IS INOPERABLE, CAUSE UNKNOWN . *AK CONSUMER ALSO STATES THAT LOW ONE GEAR IS INOPERABLE, CONSUMER ALSO EXPERIENCED HEAD GASKET FAILURE, AS WELL AS OVERHEATING IN THE FUEL TANK.*JB
NHTSA ODI #890660
Mileage unknown · Jun 14, 2001
Power Train
TORQUE CONVERTER WAS LEAKING TRANSMISSION FLUID ,AND SLIPPING BETWEEN FIRST AND SECOND GEARS. DEALERSHIP REPLACED TRANSMISSION AT CONSUMER'S EXPENSE. CONSUMER STATED THAT THERE WERE MULTIPLE TSB'S FOR THIS PROBLEM. ENGINE WAS REPLACED A YEAR AGO UNDER A SERVICE PROGRAM BY THE DEALER/MANUFACTURER. *AK
NHTSA ODI #890395
Mileage unknown · Jun 14, 2001
Power TrainService Brakes, Hydraulic
#1 ANIT-LOCK BRAKES WOULD ACTIVATE EVERY TIME THE BRAKES WERE APPLIED. #2 THE TRANSMISSION WOULD SLIP VERY BAD THAN ENGAGE VIOLENTLY FROM A STAND STILL , OR THE TRANSMISSION WOULD START OFF IN SECOND GEAR. ALSO THE TRANSMISSION WOULD SLIPP AND ENGAGE VIOLENTLY FORM A STAND STILL IN REVERSE. (SIDE NOTE MY NIEGHBOR HAS A 1996 FORD…
Read full complaint
#1 ANIT-LOCK BRAKES WOULD ACTIVATE EVERY TIME THE BRAKES WERE APPLIED. #2 THE TRANSMISSION WOULD SLIP VERY BAD THAN ENGAGE VIOLENTLY FROM A STAND STILL , OR THE TRANSMISSION WOULD START OFF IN SECOND GEAR. ALSO THE TRANSMISSION WOULD SLIPP AND ENGAGE VIOLENTLY FORM A STAND STILL IN REVERSE. (SIDE NOTE MY NIEGHBOR HAS A 1996 FORD WINDSTAR, HE ALSO HAS THE SAME PROBLEM TWICE. FIRST AT 30000 MILES, AND MOST RECENTLY AT 100000 MILES)
NHTSA ODI #746820
Mileage unknown · Jun 7, 2001
Power Train
THIS IS THE 2ND TRANSMISSION THAT I HAVE HAD GO BAD. THE FIRST ONE HAD TO BE COMPLETELY OVERHAULED AT 39,000 MILES AT A COST OF $1, 254.20. THE VAN NOW HAS 85,000 MILES ON IT AND THE TRANSMISSION HAS FAILED AGAIN. THIS TIME IT WILL COST $1,517.50 TO FIX IT. I HAVE CONTACTED FORD AND THEY INFORMED ME THAT BECAUSE THERE ARE NO…
Read full complaint
THIS IS THE 2ND TRANSMISSION THAT I HAVE HAD GO BAD. THE FIRST ONE HAD TO BE COMPLETELY OVERHAULED AT 39,000 MILES AT A COST OF $1, 254.20. THE VAN NOW HAS 85,000 MILES ON IT AND THE TRANSMISSION HAS FAILED AGAIN. THIS TIME IT WILL COST $1,517.50 TO FIX IT. I HAVE CONTACTED FORD AND THEY INFORMED ME THAT BECAUSE THERE ARE NO CURRENT PROGRAMS AVAILABLE TO COVER THIS PROBLEM, THERE IS NOTHING THEY CAN DO. I HAVE BEEN ADVISED BY THEM TO PAY FOR THE REPAIRS AGAIN AND "WAIT AND SEE" WHAT HAPPENS IN THE FUTURE WITH A POSSIBLE RECALL. I HAVE HAD NOTHING BUT PROBLEMS SINCE PURCHASING THIS VEHICLE IN 1996. I WAS ALSO INFORMED THAT THE HEAD GASKETS NEED TO BE REPLACED FOR THE THIRD TIME. THEY WERE REPLACED AT 53,000, 58,000 AND NOW 85,000. *AK
NHTSA ODI #746564
Mileage unknown · Jun 4, 2001
Power Train
FORWARD CLUTCH PISTON WAS CRACKED. THIS CAUSED TRANSMISSION TO SLIP IN & OUT OF GEAR. PART WAS MADE OF ALUMINUM. MANUFACTURER REPLACED METAL PART WITH ALUMINUM.*AK
NHTSA ODI #889728
Mileage unknown · May 30, 2001
Power Train
NO SUMMARY LISTED FOR ABOVE VEHICLE. *AK
NHTSA ODI #746167
Mileage unknown · May 30, 2001
Engine And Engine CoolingPower Train
WE HAVE REPLACED THE ENGINE, TRANSMISSION, HEAD GASKETS, AND MANY ADDITIONAL PARTS. I HAVE SPENT CLOSE TO $6,000 IN REPAIRS SINCE BUYING THIS VEHICLE. I JUST WANT FORD TO ADMIT THAT THE 95 WINDSTAR HAS PROBLEMS.
NHTSA ODI #746165
Mileage unknown · May 24, 2001
Power Train
DELAYED ACCELERATION AND JOLT WHEN COMING TO A STOP. CONSUMER FEARS TRANMISSION MAY FAIL WHILE DRIVING HIGHWAY WITH FAMILY. *AK
NHTSA ODI #889092
Mileage unknown · May 23, 2001
Power TrainVehicle Speed Control
APPEARS TO BE ANOTHER CASE OF EARLY TRANSMISSION FAILURE DUE TO DEFECTIVE COMPONENTS. DANGER AT TIME OF FAILURE WAS THAT FROM A STOP I PUT MY FOOT ON THE GAS TO MOVE FORWARD AND THE ENGINE JUST RACED. HAD I ANTICIPATED ACCELERATING TO AVOID ONCOMING TRAFFIC THERE WOULD HAVE BEEN TROUBLE.*AK
NHTSA ODI #745753
Official recalls
6Oct 13, 2009
FORD IS RECALLING MODEL YEARS 1995-2003 WINDSTAR, 2000-2003 EXCURSION DIESEL, 1993-1997 AND 1999-2003 F-250 SD THROUGH F-550 SD DIESEL, 1992-2003 E-150 THROUGH E-550, 1995-2002 EXPLORER, 1997 AND 2002 MERCURY MOUNTAINEER, 1995-1997 AND 2001-2003 RANGER, AND 1994 F53 VEHICLES EQUIPPED WITH THE TEXAS INSTRUMENTS SPEED CONTROL DEACTIVATION SWITCH (SCDS). THE SCDS MAY LEAK INTERNALLY AND THEN OVERHEAT, SMOKE, OR BURN.
Consequence & remedy
Consequence: A VEHICLE FIRE COULD OCCUR WITH OR WITHOUT THE ENGINE RUNNING.
Remedy: FORD WILL NOTIFY OWNERS THAT DEALERS WILL INSTALL A FUSED WIRING HARNESS IN LINE WITH THE SCDS. ON 1999-2003 WINDSTAR VEHICLES WITH A LEAKING SCDS, DEALERS WILL ALSO INSPECT THE ABS CONTROL MODULE CONNECTOR AND REPAIR AS NECESSARY. REPAIRS WILL BE COMPLETED FREE OF CHARGE. THE SAFETY RECALL BEGAN ON OCTOBER 27, 2009. OWNERS MAY CONTACT FORD AT 1-888-222-2751.
Apr 4, 2002
ON CERTAIN MINIVANS ORIGINALLY SOLD IN OR CURRENTLY REGISTERED IN THE STATES OF CONNECTICUT, DELAWARE, ILLINOIS, INDIANA, IOWA, MAINE, MARYLAND, MASSACHUSETTS, MICHIGAN, MINNESOTA, MISSOURI, NEW HAMPSHIRE, NEW JERSEY, NEW YORK, OHIO, PENNSYLVANIA, RHODE ISLAND, VERMONT, WEST VIRGINIA, WISCONSIN, AND THE DISTRICT OF COLUMBIA. DURING ASSEMBLY, SOME BRAKE LINES WERE INSTALLED IN A TWISTED POSITION, CAUSING CONTACT WITH THE DASH PANEL INSULATOR ABOVE THE CATALYTIC CONVERTER. THIS CONTACT COULD ABRADE THE BRAKE LINE CORROSION PROTECTION, CONSEQUENTLY, SALT OR WATER ABSORBED IN THE DASH PANEL INSULATOR WOULD PROMOTE CORROSION. THIS CORROSION COULD ULTIMATELY LEAD TO A LEAK IN THE BRAKE LINE.
Consequence & remedy
Consequence: LEAKAGE OF BRAKE FLUID WILL RESULT IN BRAKE LIGHT ACTIVATION. EXTENDED STOPPING DISTANCE COULD ALSO RESULT, INCREASING THE RISK OF A CRASH.
Remedy: DEALERS WILL INSPECT THE BRAKE LINE FOR CORROSION AND CLEARANCE CONDITIONS. A BRAKE LINE THAT IS NOT CORRODED WILL BE REPOSITIONED. A BRAKE LINE THAT IS CORRODED OR LEAKING WILL BE REPLACED WITH A NYLON COATED BRAKE LINE AND SECURED USING THREE RETAINING CLIPS TO ASSURE CLEARANCE FROM THE INSULATOR. OWNER NOTIFICATION BEGAN MAY 10, 2002. OWNERS WHO TAKE THEIR VEHICLES TO AN AUTHORIZED DEALER ON AN AGREED UPON SERVICE DATE AND DO NOT RECEIVE THE FREE REMEDY WITHIN A REASONABLE TIME SHOULD CONTACT FORD AT 1-866-436-7332.
Nov 2, 1999
VEHICLE DESCRIPTION: MINIVANS WHICH WERE ORIGINALLY SOLD OR CURRENTLY REGISTERED IN THE FOLLOWING HOT WEATHER STATES: ALABAMA, ARIZONA, ARKANSAS, CALIFORNIA (10 SOUTHERN COUNTIES), FLORIDA, GEORGIA, HAWAII, LOUISIANA, MISSISSIPPI, NEVADA (CLARK COUNTY ONLY), OKLAHOMA, SOUTH CAROLINA AND TEXAS, CAN DEVELOP CRACKS IN THE FUEL TANK IN THE FORWARD STRAP AREA OF THE STANDARD 20 GALLON TANK DUE TO A COMBINATION OF FACTORS THAT ARE PRESENT IN CERTAIN VERY HOT AREAS OF THE COUNTRY.
Consequence & remedy
Consequence: THESE CRACKS COULD RESULT IN FUEL LEAKAGE IF THEY PROPAGATE THROUGH THE WALL OF THE TANK.
Remedy: DEALERS WILL INSTALL A BRACE ASSEMBLY AT THE STRAP BOLT HOLE LOCATION AND REPLACE THE TANK STRAP WITH A REVISED, LONGER STRAP. DEALERS WILL ALSO INSPECT THE TANKS FOR LEAKS. IF A LEAK EXISTS AND IS THE RESULT OF A CRACK IN THE FUEL TANK, THE TANK WILL BE REPLACED IN ADDITION TO THE INSTALLATION OF A SPACER AND LONGER STRAP.
Oct 20, 1997
VEHICLE DESCRIPTION: PASSENGER VEHICLES AND MINI VANS. TEARING OF THE BOND BETWEEN THE INNER AND OUTER HOOD PANELS DURING MINOR FRONT END COLLISIONS CAN RESULT IN A GAP AT THE LEADING EDGE OF THE HOOD. AIR FORCED BETWEEN THE INNER AND OUTER PANELS CAN PRODUCE ENOUGH PRESSURE TO FORCE THE OUTER PANEL UPWARD.
Consequence & remedy
Consequence: THIS CONDITION CAN RESULT IN TOTAL SEPARATION OF THE OUTER HOOD PANEL.
Remedy: DEALERS WILL INSPECT THE HOOD AREA FOR ANY DAMAGE ALONG THE LEADING EDGE OF THE HOOD. IF THERE IS ANY EVIDENCE OF BOND SEPARATION, THE HOOD WILL BE REPLACED. IF THERE IS NO EVIDENCE OF BOND SEPARATION, ADDITIONAL ADHESIVE WILL BE APPLIED BETWEEN THE INNER AND OUTER HOOD PANELS.
Nov 4, 1994
THE WIRING HARNESS INSULATION CAN ABRADE ON A BRACE THAT RUNS FROM THE INSTRUMENT PANEL TO THE COWL.
Consequence & remedy
Consequence: THIS CONDITION CAN RESULT IN AN ELECTRICAL SHORT AND POSSIBLY A VEHICLE FIRE.
Remedy: DEALERS WILL INSTALL A SHIELD ON THE INSTRUMENT PANEL TO COWL BRACE, AND INSTALLATION OF A PIECE OF CONVOLUTE WRAP MATERIAL ON ONE OF THE ADJACENT HARNESSES.
Nov 4, 1994
THE ALTERNATOR OUTPUT WIRE WAS NOT CONNECTED TIGHTLY TO THE POWER DISTRIBUTION BOX.
Consequence & remedy
Consequence: THIS CAN RESULT IN OVERHEATING OF THE CONNECTION AND A POSSIBLE VEHICLE FIRE.
Remedy: DEALERS WILL INSPECT AND TIGHTEN THE CONNECTION. VEHICLES WITH VISIBLE DAMAGE TO THE PLASTIC POWER DISTRIBUTION BOX HOUSING WILL HAVE THE THE UNDERHOOD HARNESS, INCLUDING THE POWER DISTRIBUTION BOX, REPLACED.
Model-level recall history does not show whether a particular VIN is affected or has received a repair. Check a VIN with NHTSA ↗
NHTSA investigations
14EA08021 · Engine Compartment Fires
Opened Sep 17, 2008 · Closed Oct 14, 2009
Status: closed (inferred from source dates) · Electrical System; Electrical System:wiring; Service Brakes, Hydraulic; Service Brakes, Hydraulic:antilock/traction Control/electronic Limited Slip; Service Brakes, Hydraulic:antilock/traction Control/electronic Limited Slip:control Unit/module ; Vehicle Speed Control; Vehicle Speed Control:cruise Control
EA08-021 IS CLOSED WITH FORD'S ACTIONS IN RECALL 09V-399 RECALLING APPROXIMATELY 4.5 MILLION VEHICLES EQUIPPED WITH TEXAS INSTRUMENTS SPEED CONTROL DEACTIVATION SWITCHES (SCDS).WITH THIS RECALL FORD HAS NOW RECALLED ALL OF THE APPROXIMATE 16 MILLION FORD MODEL VEHICLES THAT WERE MANUFACTURED FROM MY 1992 THROUGH 2003 WITH A TEXAS INSTRUMENTS SCDS.NHTSA WILL CONTINUE TO MONITOR THE RECALLED VEHICLES TO ENSURE REMEDIES INSTALLED BY FORD TOMITIGATE THE POTENTIAL FOR SCDS RELATED FIRES ARE EFFECTIVE.THE AGENCY RESERVES THE RIGHT TO TAKE FURTHER ACTION IF WARRANTED BY THE CIRCUMSTANCES.SEE ATTACHED CLOSING REPORT FOR FURTHER DETAILS.
Additional source detail variants (7)
Electrical System
EA08-021 IS CLOSED WITH FORD'S ACTIONS IN RECALL 09V-399 RECALLING APPROXIMATELY 4.5 MILLION VEHICLES EQUIPPED WITH TEXAS INSTRUMENTS SPEED CONTROL DEACTIVATION SWITCHES (SCDS).WITH THIS RECALL FORD HAS NOW RECALLED ALL OF THE APPROXIMATE 16 MILLION FORD MODEL VEHICLES THAT WERE MANUFACTURED FROM MY 1992 THROUGH 2003 WITH A TEXAS INSTRUMENTS SCDS.NHTSA WILL CONTINUE TO MONITOR THE RECALLED VEHICLES TO ENSURE REMEDIES INSTALLED BY FORD TOMITIGATE THE POTENTIAL FOR SCDS RELATED FIRES ARE EFFECTIVE.THE AGENCY RESERVES THE RIGHT TO TAKE FURTHER ACTION IF WARRANTED BY THE CIRCUMSTANCES.SEE ATTACHED CLOSING REPORT FOR FURTHER DETAILS.
Electrical System:wiring
EA08-021 IS CLOSED WITH FORD'S ACTIONS IN RECALL 09V-399 RECALLING APPROXIMATELY 4.5 MILLION VEHICLES EQUIPPED WITH TEXAS INSTRUMENTS SPEED CONTROL DEACTIVATION SWITCHES (SCDS).WITH THIS RECALL FORD HAS NOW RECALLED ALL OF THE APPROXIMATE 16 MILLION FORD MODEL VEHICLES THAT WERE MANUFACTURED FROM MY 1992 THROUGH 2003 WITH A TEXAS INSTRUMENTS SCDS.NHTSA WILL CONTINUE TO MONITOR THE RECALLED VEHICLES TO ENSURE REMEDIES INSTALLED BY FORD TOMITIGATE THE POTENTIAL FOR SCDS RELATED FIRES ARE EFFECTIVE.THE AGENCY RESERVES THE RIGHT TO TAKE FURTHER ACTION IF WARRANTED BY THE CIRCUMSTANCES.SEE ATTACHED CLOSING REPORT FOR FURTHER DETAILS.
Service Brakes, Hydraulic:antilock/traction Control/electronic Limited Slip:control Unit/module
EA08-021 IS CLOSED WITH FORD'S ACTIONS IN RECALL 09V-399 RECALLING APPROXIMATELY 4.5 MILLION VEHICLES EQUIPPED WITH TEXAS INSTRUMENTS SPEED CONTROL DEACTIVATION SWITCHES (SCDS).WITH THIS RECALL FORD HAS NOW RECALLED ALL OF THE APPROXIMATE 16 MILLION FORD MODEL VEHICLES THAT WERE MANUFACTURED FROM MY 1992 THROUGH 2003 WITH A TEXAS INSTRUMENTS SCDS.NHTSA WILL CONTINUE TO MONITOR THE RECALLED VEHICLES TO ENSURE REMEDIES INSTALLED BY FORD TOMITIGATE THE POTENTIAL FOR SCDS RELATED FIRES ARE EFFECTIVE.THE AGENCY RESERVES THE RIGHT TO TAKE FURTHER ACTION IF WARRANTED BY THE CIRCUMSTANCES.SEE ATTACHED CLOSING REPORT FOR FURTHER DETAILS.
Service Brakes, Hydraulic:antilock/traction Control/electronic Limited Slip
EA08-021 IS CLOSED WITH FORD'S ACTIONS IN RECALL 09V-399 RECALLING APPROXIMATELY 4.5 MILLION VEHICLES EQUIPPED WITH TEXAS INSTRUMENTS SPEED CONTROL DEACTIVATION SWITCHES (SCDS).WITH THIS RECALL FORD HAS NOW RECALLED ALL OF THE APPROXIMATE 16 MILLION FORD MODEL VEHICLES THAT WERE MANUFACTURED FROM MY 1992 THROUGH 2003 WITH A TEXAS INSTRUMENTS SCDS.NHTSA WILL CONTINUE TO MONITOR THE RECALLED VEHICLES TO ENSURE REMEDIES INSTALLED BY FORD TOMITIGATE THE POTENTIAL FOR SCDS RELATED FIRES ARE EFFECTIVE.THE AGENCY RESERVES THE RIGHT TO TAKE FURTHER ACTION IF WARRANTED BY THE CIRCUMSTANCES.SEE ATTACHED CLOSING REPORT FOR FURTHER DETAILS.
Service Brakes, Hydraulic
EA08-021 IS CLOSED WITH FORD'S ACTIONS IN RECALL 09V-399 RECALLING APPROXIMATELY 4.5 MILLION VEHICLES EQUIPPED WITH TEXAS INSTRUMENTS SPEED CONTROL DEACTIVATION SWITCHES (SCDS).WITH THIS RECALL FORD HAS NOW RECALLED ALL OF THE APPROXIMATE 16 MILLION FORD MODEL VEHICLES THAT WERE MANUFACTURED FROM MY 1992 THROUGH 2003 WITH A TEXAS INSTRUMENTS SCDS.NHTSA WILL CONTINUE TO MONITOR THE RECALLED VEHICLES TO ENSURE REMEDIES INSTALLED BY FORD TOMITIGATE THE POTENTIAL FOR SCDS RELATED FIRES ARE EFFECTIVE.THE AGENCY RESERVES THE RIGHT TO TAKE FURTHER ACTION IF WARRANTED BY THE CIRCUMSTANCES.SEE ATTACHED CLOSING REPORT FOR FURTHER DETAILS.
Vehicle Speed Control:cruise Control
EA08-021 IS CLOSED WITH FORD'S ACTIONS IN RECALL 09V-399 RECALLING APPROXIMATELY 4.5 MILLION VEHICLES EQUIPPED WITH TEXAS INSTRUMENTS SPEED CONTROL DEACTIVATION SWITCHES (SCDS).WITH THIS RECALL FORD HAS NOW RECALLED ALL OF THE APPROXIMATE 16 MILLION FORD MODEL VEHICLES THAT WERE MANUFACTURED FROM MY 1992 THROUGH 2003 WITH A TEXAS INSTRUMENTS SCDS.NHTSA WILL CONTINUE TO MONITOR THE RECALLED VEHICLES TO ENSURE REMEDIES INSTALLED BY FORD TOMITIGATE THE POTENTIAL FOR SCDS RELATED FIRES ARE EFFECTIVE.THE AGENCY RESERVES THE RIGHT TO TAKE FURTHER ACTION IF WARRANTED BY THE CIRCUMSTANCES.SEE ATTACHED CLOSING REPORT FOR FURTHER DETAILS.
Vehicle Speed Control
EA08-021 IS CLOSED WITH FORD'S ACTIONS IN RECALL 09V-399 RECALLING APPROXIMATELY 4.5 MILLION VEHICLES EQUIPPED WITH TEXAS INSTRUMENTS SPEED CONTROL DEACTIVATION SWITCHES (SCDS).WITH THIS RECALL FORD HAS NOW RECALLED ALL OF THE APPROXIMATE 16 MILLION FORD MODEL VEHICLES THAT WERE MANUFACTURED FROM MY 1992 THROUGH 2003 WITH A TEXAS INSTRUMENTS SCDS.NHTSA WILL CONTINUE TO MONITOR THE RECALLED VEHICLES TO ENSURE REMEDIES INSTALLED BY FORD TOMITIGATE THE POTENTIAL FOR SCDS RELATED FIRES ARE EFFECTIVE.THE AGENCY RESERVES THE RIGHT TO TAKE FURTHER ACTION IF WARRANTED BY THE CIRCUMSTANCES.SEE ATTACHED CLOSING REPORT FOR FURTHER DETAILS.
PE08035 · Engine Compartment Fires
Opened May 13, 2008 · Closed Sep 17, 2008
Status: closed (inferred from source dates) · Electrical System; Electrical System:wiring; Vehicle Speed Control
ODI HAS RECEIVED 134 CONSUMER COMPLAINTS, 285 MANUFACTURER COMPLAINTS, AND 137 MANUFACTURER WARRANTY CLAIMS ALLEGING INCIDENTS OF ENGINE COMPARTMENT FIRE IN MODEL YEAR (MY) 1995 THRU 2003 FORD WINDSTAR VEHICLES.TWO OF THE ODI COMPLAINTS ALLEGE THE FIRES CAUSED STRUCTURAL DAMAGE TO THE COMPLAINANT'S HOME.OF THE 134 ODI COMPLAINTS, 36 ALLEGE THE FIRE OCCURRED WHILE THE VEHICLE WAS PARKED, 72 ALLEGE THE FIRE OCCURRED WHILE THE VEHICLE WAS RUNNING AND 26 OF THE COMPLAINTS DO NOT SPECIFY IF THE VEHICLE WAS RUNNING OR NOT.FURTHER REVIEW OF THE ODI COMPLAINTS SHOWS THAT 72 ALLEGE THAT THE SPEED CONTROL DEACTIVATION SWITCH (SCDS) CAUSED THE FIRE AND 10 ALLEGE THAT THE SCDS LEAKED BRAKE FLUID ON TO THE ABS MODULE RESULTING IN THE FIRE.THERE WERE 52 THAT DID NOT IDENTIFY A CAUSE OR THAT IDENTIFIED MISCELLANEOUS OTHER CAUSES.ODI HAS ALSO RECEIVED 89 COMPLAINTS ( NOT COUNTED IN THIS RESUME) ALLEGING THAT THE SCDS DEVELOPED A BRAKE FLUID LEAK.THIRTEEN OF THESE COMPLAINTS SAY THAT THE LEAK AT THE SCDS RESULTED IN BRAKED FLUID REACHING THE ABS MODULE.THIS PE HAS BEEN UPGRADED TO AN ENGINEERING ANALYSIS (EA) TO FURTHER EVALUATE THE CAUSE OF THE FIRES AND ASSESS THE SCOPE, FREQUENCY, AND SAFETY CONSEQUENCES OF THE ALLEGED DEFECT.
Additional source detail variants (3)
Electrical System
ODI HAS RECEIVED 134 CONSUMER COMPLAINTS, 285 MANUFACTURER COMPLAINTS, AND 137 MANUFACTURER WARRANTY CLAIMS ALLEGING INCIDENTS OF ENGINE COMPARTMENT FIRE IN MODEL YEAR (MY) 1995 THRU 2003 FORD WINDSTAR VEHICLES.TWO OF THE ODI COMPLAINTS ALLEGE THE FIRES CAUSED STRUCTURAL DAMAGE TO THE COMPLAINANT'S HOME.OF THE 134 ODI COMPLAINTS, 36 ALLEGE THE FIRE OCCURRED WHILE THE VEHICLE WAS PARKED, 72 ALLEGE THE FIRE OCCURRED WHILE THE VEHICLE WAS RUNNING AND 26 OF THE COMPLAINTS DO NOT SPECIFY IF THE VEHICLE WAS RUNNING OR NOT.FURTHER REVIEW OF THE ODI COMPLAINTS SHOWS THAT 72 ALLEGE THAT THE SPEED CONTROL DEACTIVATION SWITCH (SCDS) CAUSED THE FIRE AND 10 ALLEGE THAT THE SCDS LEAKED BRAKE FLUID ON TO THE ABS MODULE RESULTING IN THE FIRE.THERE WERE 52 THAT DID NOT IDENTIFY A CAUSE OR THAT IDENTIFIED MISCELLANEOUS OTHER CAUSES.ODI HAS ALSO RECEIVED 89 COMPLAINTS ( NOT COUNTED IN THIS RESUME) ALLEGING THAT THE SCDS DEVELOPED A BRAKE FLUID LEAK.THIRTEEN OF THESE COMPLAINTS SAY THAT THE LEAK AT THE SCDS RESULTED IN BRAKED FLUID REACHING THE ABS MODULE.THIS PE HAS BEEN UPGRADED TO AN ENGINEERING ANALYSIS (EA) TO FURTHER EVALUATE THE CAUSE OF THE FIRES AND ASSESS THE SCOPE, FREQUENCY, AND SAFETY CONSEQUENCES OF THE ALLEGED DEFECT.
Electrical System:wiring
ODI HAS RECEIVED 134 CONSUMER COMPLAINTS, 285 MANUFACTURER COMPLAINTS, AND 137 MANUFACTURER WARRANTY CLAIMS ALLEGING INCIDENTS OF ENGINE COMPARTMENT FIRE IN MODEL YEAR (MY) 1995 THRU 2003 FORD WINDSTAR VEHICLES.TWO OF THE ODI COMPLAINTS ALLEGE THE FIRES CAUSED STRUCTURAL DAMAGE TO THE COMPLAINANT'S HOME.OF THE 134 ODI COMPLAINTS, 36 ALLEGE THE FIRE OCCURRED WHILE THE VEHICLE WAS PARKED, 72 ALLEGE THE FIRE OCCURRED WHILE THE VEHICLE WAS RUNNING AND 26 OF THE COMPLAINTS DO NOT SPECIFY IF THE VEHICLE WAS RUNNING OR NOT.FURTHER REVIEW OF THE ODI COMPLAINTS SHOWS THAT 72 ALLEGE THAT THE SPEED CONTROL DEACTIVATION SWITCH (SCDS) CAUSED THE FIRE AND 10 ALLEGE THAT THE SCDS LEAKED BRAKE FLUID ON TO THE ABS MODULE RESULTING IN THE FIRE.THERE WERE 52 THAT DID NOT IDENTIFY A CAUSE OR THAT IDENTIFIED MISCELLANEOUS OTHER CAUSES.ODI HAS ALSO RECEIVED 89 COMPLAINTS ( NOT COUNTED IN THIS RESUME) ALLEGING THAT THE SCDS DEVELOPED A BRAKE FLUID LEAK.THIRTEEN OF THESE COMPLAINTS SAY THAT THE LEAK AT THE SCDS RESULTED IN BRAKED FLUID REACHING THE ABS MODULE.THIS PE HAS BEEN UPGRADED TO AN ENGINEERING ANALYSIS (EA) TO FURTHER EVALUATE THE CAUSE OF THE FIRES AND ASSESS THE SCOPE, FREQUENCY, AND SAFETY CONSEQUENCES OF THE ALLEGED DEFECT.
Vehicle Speed Control
ODI HAS RECEIVED 134 CONSUMER COMPLAINTS, 285 MANUFACTURER COMPLAINTS, AND 137 MANUFACTURER WARRANTY CLAIMS ALLEGING INCIDENTS OF ENGINE COMPARTMENT FIRE IN MODEL YEAR (MY) 1995 THRU 2003 FORD WINDSTAR VEHICLES.TWO OF THE ODI COMPLAINTS ALLEGE THE FIRES CAUSED STRUCTURAL DAMAGE TO THE COMPLAINANT'S HOME.OF THE 134 ODI COMPLAINTS, 36 ALLEGE THE FIRE OCCURRED WHILE THE VEHICLE WAS PARKED, 72 ALLEGE THE FIRE OCCURRED WHILE THE VEHICLE WAS RUNNING AND 26 OF THE COMPLAINTS DO NOT SPECIFY IF THE VEHICLE WAS RUNNING OR NOT.FURTHER REVIEW OF THE ODI COMPLAINTS SHOWS THAT 72 ALLEGE THAT THE SPEED CONTROL DEACTIVATION SWITCH (SCDS) CAUSED THE FIRE AND 10 ALLEGE THAT THE SCDS LEAKED BRAKE FLUID ON TO THE ABS MODULE RESULTING IN THE FIRE.THERE WERE 52 THAT DID NOT IDENTIFY A CAUSE OR THAT IDENTIFIED MISCELLANEOUS OTHER CAUSES.ODI HAS ALSO RECEIVED 89 COMPLAINTS ( NOT COUNTED IN THIS RESUME) ALLEGING THAT THE SCDS DEVELOPED A BRAKE FLUID LEAK.THIRTEEN OF THESE COMPLAINTS SAY THAT THE LEAK AT THE SCDS RESULTED IN BRAKED FLUID REACHING THE ABS MODULE.THIS PE HAS BEEN UPGRADED TO AN ENGINEERING ANALYSIS (EA) TO FURTHER EVALUATE THE CAUSE OF THE FIRES AND ASSESS THE SCOPE, FREQUENCY, AND SAFETY CONSEQUENCES OF THE ALLEGED DEFECT.
RQ04003 · Hydraulic Brake Line Failure
Opened May 27, 2004 · Closed Oct 7, 2004
Status: closed (inferred from source dates) · Service Brakes, Hydraulic; Service Brakes, Hydraulic:fluid; Service Brakes, Hydraulic:foundation Components:hoses, Lines/piping, And Fittings
ON APRIL 4, 2002, FORD MOTOR COMPANY NOTIFIED ODI OF A DEFECT CONDITION THAT COULD RESULT IN EXTENDED STOPPING DISTANCES IN APPROXIMATELY 250 THOUSAND MODEL YEAR (MY) 1995 AND 1996 WINDSTAR MINIVANS SOLD OR REGISTERED IN SALT BELT STATES (RECALL 02V-101).ACCORDING TO FORD, IMPROPER BRAKE LINE ROUTING IN VEHICLES MANUFACTURED AT THE OAKVILLE ASSEMBLY PLANT FROM JANUARY 14, 1994 THROUGH MAY 21, 1996 RESULTED IN SOME VEHICLES WITH MIS-POSITIONED BRAKE LINES THAT COULD CONTACT A DASH PANEL INSULATOR.SUCH CONTACT COULD ABRADE THE BRAKE LINE PROTECTION COATING AND RESULT IN CORROSIVE FAILURE OF THE BRAKE LINES. ODI OPENED RQ04-003 TO INVESTIGATE COMPLAINTS OF BRAKE LINE FAILURE IN WINDSTAR VEHICLES THAT WERE:(1) LOCATED OUTSIDE THE RECALL REGION; OR (2) BUILT AFTER THE RECALL RANGE.REGARDING THE LATTER GROUP, FORD CHANGED THE ASSEMBLY PROCESS AFTER MAY 21, 1996 TO ELIMINATE THE MIS-BUILD PROBLEM.THE FAILURE RATES IN THE MY 1996 WINDSTAR VEHICLES BUILT AFTER THE PROCESS CHANGE ARE RELATIVELY LOW IN BOTH THE SALT-BELT STATES. WITH RESPECT TO THE MY 1995 AND 1996 VEHICLES BUILT DURING THE PERIOD OF CONCERN THAT WERE NOT SOLD OR REGISTERED IN SALT BELT STATES, THE FAILURE RATE IS ALSO LOW.THE RELATED BRAKE LINE WARRANTY CLAIM RATE FOR THOSE VEHICLES IS ALSO LOW. ACCORDINGLY, A SAFETY-RELATED DEFECT TREND HAS NOT BEEN IDENTIFIED IN THE MY 1995-96 WINDSTAR VEHICLES THAT WERE NOT INCLUDED IN RECALL 02V-101.FURTHER USE OF AGENCY RESOURCES DOES NOT APPEAR TO BE WARRANTED.THE CLOSING OF THIS INVESTIGATION DOES NOT CONSTITUTE A FINDING BY NHTSA THAT NO SAFETY-RELATED DEFECT EXISTS.THE AGENCY RESERVES THE RIGHT TO TAKE FURTHER ACTION IF WARRANTED BY THE CIRCUMSTANCES.
Additional source detail variants (3)
Service Brakes, Hydraulic:fluid
ON APRIL 4, 2002, FORD MOTOR COMPANY NOTIFIED ODI OF A DEFECT CONDITION THAT COULD RESULT IN EXTENDED STOPPING DISTANCES IN APPROXIMATELY 250 THOUSAND MODEL YEAR (MY) 1995 AND 1996 WINDSTAR MINIVANS SOLD OR REGISTERED IN SALT BELT STATES (RECALL 02V-101).ACCORDING TO FORD, IMPROPER BRAKE LINE ROUTING IN VEHICLES MANUFACTURED AT THE OAKVILLE ASSEMBLY PLANT FROM JANUARY 14, 1994 THROUGH MAY 21, 1996 RESULTED IN SOME VEHICLES WITH MIS-POSITIONED BRAKE LINES THAT COULD CONTACT A DASH PANEL INSULATOR.SUCH CONTACT COULD ABRADE THE BRAKE LINE PROTECTION COATING AND RESULT IN CORROSIVE FAILURE OF THE BRAKE LINES. ODI OPENED RQ04-003 TO INVESTIGATE COMPLAINTS OF BRAKE LINE FAILURE IN WINDSTAR VEHICLES THAT WERE:(1) LOCATED OUTSIDE THE RECALL REGION; OR (2) BUILT AFTER THE RECALL RANGE.REGARDING THE LATTER GROUP, FORD CHANGED THE ASSEMBLY PROCESS AFTER MAY 21, 1996 TO ELIMINATE THE MIS-BUILD PROBLEM.THE FAILURE RATES IN THE MY 1996 WINDSTAR VEHICLES BUILT AFTER THE PROCESS CHANGE ARE RELATIVELY LOW IN BOTH THE SALT-BELT STATES. WITH RESPECT TO THE MY 1995 AND 1996 VEHICLES BUILT DURING THE PERIOD OF CONCERN THAT WERE NOT SOLD OR REGISTERED IN SALT BELT STATES, THE FAILURE RATE IS ALSO LOW.THE RELATED BRAKE LINE WARRANTY CLAIM RATE FOR THOSE VEHICLES IS ALSO LOW. ACCORDINGLY, A SAFETY-RELATED DEFECT TREND HAS NOT BEEN IDENTIFIED IN THE MY 1995-96 WINDSTAR VEHICLES THAT WERE NOT INCLUDED IN RECALL 02V-101.FURTHER USE OF AGENCY RESOURCES DOES NOT APPEAR TO BE WARRANTED.THE CLOSING OF THIS INVESTIGATION DOES NOT CONSTITUTE A FINDING BY NHTSA THAT NO SAFETY-RELATED DEFECT EXISTS.THE AGENCY RESERVES THE RIGHT TO TAKE FURTHER ACTION IF WARRANTED BY THE CIRCUMSTANCES.
Service Brakes, Hydraulic
ON APRIL 4, 2002, FORD MOTOR COMPANY NOTIFIED ODI OF A DEFECT CONDITION THAT COULD RESULT IN EXTENDED STOPPING DISTANCES IN APPROXIMATELY 250 THOUSAND MODEL YEAR (MY) 1995 AND 1996 WINDSTAR MINIVANS SOLD OR REGISTERED IN SALT BELT STATES (RECALL 02V-101).ACCORDING TO FORD, IMPROPER BRAKE LINE ROUTING IN VEHICLES MANUFACTURED AT THE OAKVILLE ASSEMBLY PLANT FROM JANUARY 14, 1994 THROUGH MAY 21, 1996 RESULTED IN SOME VEHICLES WITH MIS-POSITIONED BRAKE LINES THAT COULD CONTACT A DASH PANEL INSULATOR.SUCH CONTACT COULD ABRADE THE BRAKE LINE PROTECTION COATING AND RESULT IN CORROSIVE FAILURE OF THE BRAKE LINES. ODI OPENED RQ04-003 TO INVESTIGATE COMPLAINTS OF BRAKE LINE FAILURE IN WINDSTAR VEHICLES THAT WERE:(1) LOCATED OUTSIDE THE RECALL REGION; OR (2) BUILT AFTER THE RECALL RANGE.REGARDING THE LATTER GROUP, FORD CHANGED THE ASSEMBLY PROCESS AFTER MAY 21, 1996 TO ELIMINATE THE MIS-BUILD PROBLEM.THE FAILURE RATES IN THE MY 1996 WINDSTAR VEHICLES BUILT AFTER THE PROCESS CHANGE ARE RELATIVELY LOW IN BOTH THE SALT-BELT STATES. WITH RESPECT TO THE MY 1995 AND 1996 VEHICLES BUILT DURING THE PERIOD OF CONCERN THAT WERE NOT SOLD OR REGISTERED IN SALT BELT STATES, THE FAILURE RATE IS ALSO LOW.THE RELATED BRAKE LINE WARRANTY CLAIM RATE FOR THOSE VEHICLES IS ALSO LOW. ACCORDINGLY, A SAFETY-RELATED DEFECT TREND HAS NOT BEEN IDENTIFIED IN THE MY 1995-96 WINDSTAR VEHICLES THAT WERE NOT INCLUDED IN RECALL 02V-101.FURTHER USE OF AGENCY RESOURCES DOES NOT APPEAR TO BE WARRANTED.THE CLOSING OF THIS INVESTIGATION DOES NOT CONSTITUTE A FINDING BY NHTSA THAT NO SAFETY-RELATED DEFECT EXISTS.THE AGENCY RESERVES THE RIGHT TO TAKE FURTHER ACTION IF WARRANTED BY THE CIRCUMSTANCES.
Service Brakes, Hydraulic:foundation Components:hoses, Lines/piping, And Fittings
ON APRIL 4, 2002, FORD MOTOR COMPANY NOTIFIED ODI OF A DEFECT CONDITION THAT COULD RESULT IN EXTENDED STOPPING DISTANCES IN APPROXIMATELY 250 THOUSAND MODEL YEAR (MY) 1995 AND 1996 WINDSTAR MINIVANS SOLD OR REGISTERED IN SALT BELT STATES (RECALL 02V-101).ACCORDING TO FORD, IMPROPER BRAKE LINE ROUTING IN VEHICLES MANUFACTURED AT THE OAKVILLE ASSEMBLY PLANT FROM JANUARY 14, 1994 THROUGH MAY 21, 1996 RESULTED IN SOME VEHICLES WITH MIS-POSITIONED BRAKE LINES THAT COULD CONTACT A DASH PANEL INSULATOR.SUCH CONTACT COULD ABRADE THE BRAKE LINE PROTECTION COATING AND RESULT IN CORROSIVE FAILURE OF THE BRAKE LINES. ODI OPENED RQ04-003 TO INVESTIGATE COMPLAINTS OF BRAKE LINE FAILURE IN WINDSTAR VEHICLES THAT WERE:(1) LOCATED OUTSIDE THE RECALL REGION; OR (2) BUILT AFTER THE RECALL RANGE.REGARDING THE LATTER GROUP, FORD CHANGED THE ASSEMBLY PROCESS AFTER MAY 21, 1996 TO ELIMINATE THE MIS-BUILD PROBLEM.THE FAILURE RATES IN THE MY 1996 WINDSTAR VEHICLES BUILT AFTER THE PROCESS CHANGE ARE RELATIVELY LOW IN BOTH THE SALT-BELT STATES. WITH RESPECT TO THE MY 1995 AND 1996 VEHICLES BUILT DURING THE PERIOD OF CONCERN THAT WERE NOT SOLD OR REGISTERED IN SALT BELT STATES, THE FAILURE RATE IS ALSO LOW.THE RELATED BRAKE LINE WARRANTY CLAIM RATE FOR THOSE VEHICLES IS ALSO LOW. ACCORDINGLY, A SAFETY-RELATED DEFECT TREND HAS NOT BEEN IDENTIFIED IN THE MY 1995-96 WINDSTAR VEHICLES THAT WERE NOT INCLUDED IN RECALL 02V-101.FURTHER USE OF AGENCY RESOURCES DOES NOT APPEAR TO BE WARRANTED.THE CLOSING OF THIS INVESTIGATION DOES NOT CONSTITUTE A FINDING BY NHTSA THAT NO SAFETY-RELATED DEFECT EXISTS.THE AGENCY RESERVES THE RIGHT TO TAKE FURTHER ACTION IF WARRANTED BY THE CIRCUMSTANCES.
RQ02011 · Fuel Tank Fatigue Cracking
Opened Aug 29, 2002 · Closed Mar 14, 2003
Status: closed (inferred from source dates) · Fuel System, Gasoline:storage:tank Assembly
SEE ATTACHED REPORT.
EA00027 · Suspension Coil Spring Breakage
Opened Dec 8, 2000 · Closed Jul 31, 2001
Status: closed (inferred from source dates) · Suspension
There is no summary currently available
Additional source detail variants (2)
Suspension
There is no summary currently available
Suspension
There is no summary currently available
PE00024 · Suspension Coil Spring Breakage
Opened Jun 23, 2000 · Closed Dec 8, 2000
Status: closed (inferred from source dates) · Suspension
There is no summary currently available
EA99020 · Fuel Tank Cracks
Opened Jul 26, 1999 · Closed Dec 16, 1999
Status: closed (inferred from source dates) · Fuel System, Gasoline
There is no summary currently available
PE99025 · Fuel Tank Cracks
Opened Apr 15, 1999 · Closed Jul 26, 1999
Status: closed (inferred from source dates) · Fuel System, Gasoline
There is no summary currently available
PE98056 · Rear Axle Trailing Arm
Opened Oct 28, 1998 · Closed Feb 24, 1999
Status: closed (inferred from source dates) · Service Brakes, Hydraulic
There is no summary currently available
DP98004 · Automatic Transmission Failure
Opened May 18, 1998 · Closed Jul 2, 1998
Status: closed (inferred from source dates) · Power Train
There is no summary currently available
EA97018 · Outer Hood Panel Detachment
Opened Sep 30, 1997 · Closed Oct 22, 1997
Status: closed (inferred from source dates) · Structure
There is no summary currently available
PE97011 · Outer Hood Panel Detachment
Opened Mar 13, 1997 · Closed Sep 30, 1997
Status: closed (inferred from source dates) · Structure
THE OFFICE OF DEFECTS INVESTIGATION HAS RECEIVED 6 REPORTS INDICATING THE OUTER HOOD PANEL SEPARATED FROM THE VEHICLES AS THEY WERE BEING DRIVEN.FORD HAS PROVIDE 39 ADDITIONAL REPORTS THAT ARE CONSISTENT WITH ODI REPORTS.FORD INDICATES THAT THE LIKELY CAUSE IS PRIOR COLLISION DAMAGE.THIS INVESTIGATION IS BEING UPGRADED TO FURTHER STUDY THIS ISSUE.
EA96026 · Brake Pedal Fade/extended Stop Distance
Opened Oct 31, 1996 · Closed Feb 18, 2000
Status: closed (inferred from source dates) · Service Brakes, Hydraulic
There is no summary currently available
PE96042 · Brake Pedal Fade/extended Stopping
Opened Jun 13, 1996 · Closed Oct 31, 1996
Status: closed (inferred from source dates) · Service Brakes, Hydraulic
ODI HAS RECEIVED SIXTY-EIGHT (68) CONSUMER REPORTS OF ALLEGED FAILURES OR MALFUNCTIONS IN THE BRAKE SYSTEM ON CERTAIN 1995 AND 1996 FORD WINDSTARS, WHICH RESULTED IN BRAKE PEDAL FADE AND IN EXTENDED STOPPING DISTANCES DURING BRAKINGTHESE ALLEGED FAILURES OR MALFUNCTIONS ARE REPORTED TO HAVE CAUSED TWELVE (12) ACCIDENTS THAT RESULTED FROM VEHICLE LOSS OF BRAKING.THE CONPLAINANTS REPORT THAT THE LOSS OF BRAKING OCCURRED DURINGBRAKING SITUATIONS ON DRY ROADS AS WELL AS ON WET OR SLIPPERY ROADS.IN RESPONSE TO ODI'S INFORMATION REQUES (IR) CONCERNING THE LONG STOPPING DISTANCE COMPLAINTS ON THE 1995 WINDSTAR, FORD REPORTED RECEIVING 259 REPORT (FIELD REPORTS, OWNER COMPLAINTS, AND SUBROGATION CLAIMS) OF LONG STOPPING DISTANCE ON THE 1995 FORD WINDSTAR, ALONG WITH 64 REPORTS OF ACCIDENTS.IN ADDITION, FORD REPORTED RECEIVING SOME 64,000 WARRANTY CLAIMS THAT COULD RELATE TO THE ALLEGED DEFECT OF LONG STOPPING DISTANCE PERFORMANCE ON THE SUBJECT VEHICLES.SINCE APRELIMINARY EVALUATION WAS OPENED, ODI HAS RECEIVED ADDITIONAL COMPLAINTS OF THE ALLEGED FAILURE ON THE 1996 MODELS, WHICH WERE NOT INCLUDED INITIALLY IN THIS INVESTIGATION.ODI BELIEVES THAT AN ENGINEERING ANALYSIS ON THE 1995 AND 1996 FORD WINDSTAR VEHICES IN WARRANTED TO DETERMINE THE SCOPE OF THE PROBLEM.