RECALL 93V125000 PERFORMED IN 1994, VEHICLE HAS SAME PROBLEM AGAIN. *AK
1990 Ford F250
Owner reports · Recalls · Investigations
Limited comparison data
There is not enough comparable history to draw a useful model-year comparison.
About this comparison →How this year compares
Owner complaints by model year
Compare all F250 years →Counts vary with age, sales and reporting. They are not failure rates.
What owners reported most
All reported categories
Tap a category to read its complaints. One report may name several components.
When problems were reported
Mileage at the reported incident
Limited mileage data: 10 of 107 reports include usable mileage. There isn’t enough coverage to show a useful chart.
NHTSA’s mileage field refers to the reported incident, not necessarily the filing date. This shows report counts, not the likelihood of a failure.
What to inspect
Issues worth paying extra attention to based on owner reports.
- Fuel System, Gasoline. Review the 35 owner reports in this category and discuss these concerns during a pre-purchase inspection. Read reports →
- Service Brakes, Hydraulic. Review the 27 owner reports in this category and discuss these concerns during a pre-purchase inspection. Read reports →
- Electrical System. Review the 14 owner reports in this category and discuss these concerns during a pre-purchase inspection. Read reports →
NHTSA owner reports · September 18, 2026 snapshot.
What owners actually said
107 reportsTRANSMISSION FAILURE. *AK
EQUIPPED WITH TOWING PACKAGE AXLE SEAL FAILED, AND LEAKED OIL ONTO BRAKE LINE ,CAUSING FAILURE OF BRAKES. 2. LIGHT SWITCH SHORTED OUT, BURNING ALL WIRES, AND CAUSING FIRE HAZARD.*AK
HELLO, I PURCHASED THE ABOVE VEHICLE USED FROM A PRIVATE CITIZEN. THE PURCHASE DATE WAS JUNE 1991. AT THE TIME OF PURCHASE THE VEHICLE HAD AFTERMARKET WHEELS AND TIRES INSTALLED. THE ORIGIONAL WHEELS AND TIRES WERE PROVIDED TO ME WHICH I STILL HAVE BUT HAVE NOT BEEN USING. ALL FOUR TIRES HAVE A DEFECT IN THE SIDE WALL. THE DEFE…
Read full complaint
HELLO, I PURCHASED THE ABOVE VEHICLE USED FROM A PRIVATE CITIZEN. THE PURCHASE DATE WAS JUNE 1991. AT THE TIME OF PURCHASE THE VEHICLE HAD AFTERMARKET WHEELS AND TIRES INSTALLED. THE ORIGIONAL WHEELS AND TIRES WERE PROVIDED TO ME WHICH I STILL HAVE BUT HAVE NOT BEEN USING. ALL FOUR TIRES HAVE A DEFECT IN THE SIDE WALL. THE DEFECT IS BUBBLE WITH AN ELONGATED SPLIT APPROXIMATELY 1/2 TO 3/4 OF AN INCH LONG. WHEN I PURCHASED THE VEHICLE IT HAD APPROXIMTELY 17,000 MILES ON IT. THE ORIGIONAL OWNER TOLD ME THAT THE AFTERMARKET WHEELS AND TIRES WERE INSTALLED WHEN THE VEHICLE HAD APPROXIMATELY 15,000 MILES ON IT. (TIRESIZE: 235/85R16)( DOT NUMBER: TIRE SIZE: 235/85R16 )
I HAVE TRIED TO E-MAIL BRIDGE BUT THE E-MAIL KEEPS GETTING SENT BACK. BOTH REAR TIRES FAILED WITHIN 30 DAYS OF EACH OTHER. *AK (TIRESIZE: LT2358516)( DOT NUMBER: TIRE SIZE: LT2358516 )
CONTINUING STALLING OF THE ENGINE SINCE SHORTLY AFTER I PURCHASED THE VEHICLE. THE TRUCK HAD ONLY 27000 MILES ON IT WHEN I PURCHASED IT. I THOUGHT IT NEEDED A TUNE UP. HOWEVER, A COMPLETE TUNE UP WHICH I HAD AT APPROXIMATELY 50,000 MILES DID NOT FIX THE OCCASIONAL STALLING. I WAS TOLD AFTER A DIAGNOSTIC SYSTEMS CHECK THAT…
Read full complaint
CONTINUING STALLING OF THE ENGINE SINCE SHORTLY AFTER I PURCHASED THE VEHICLE. THE TRUCK HAD ONLY 27000 MILES ON IT WHEN I PURCHASED IT. I THOUGHT IT NEEDED A TUNE UP. HOWEVER, A COMPLETE TUNE UP WHICH I HAD AT APPROXIMATELY 50,000 MILES DID NOT FIX THE OCCASIONAL STALLING. I WAS TOLD AFTER A DIAGNOSTIC SYSTEMS CHECK THAT IT WAS THE EGR VALVE AND I HAD THAT REPLACED. IT DID NOT SOLVE THE PROBLEM. NOW, WITH THE HEAT OF THE SUMMER THE PROBLEM IS GETTING WORSE WITH IT STALLING WHENEVER I SLOW DOWN FOR CURVES, HIGHWAY EXITS, ETC. WHEN I HAVE ASKED A LOCAL FORD DEALER PARTS PERSON ABOUT THE STALLING PROBLEM THEY HAVE STILL POINTED TO THE EGR VALVE. BUT AFTER HEARING YESTERDAY'S NEWS REPORT ABOUT THE TFI MODULE AND COMPARING MY STALLING PROBLEMS TO WHAT I HAVE LEARNED, I WOULD SAY THAT IT IS THE TFI MODULE. THIS STALLING COULD DEFINITELY CAUSE AN ACCIDENT. TO REPLACE THE MODULE THE DEALER COST WOULD BE $99.87 FOR THE PART, PLUS LABOR. I REALIZE THAT AFTER 3 YEARS OF OWNING THIS VEHICLE I NOW HAVE 82,000 MILES ON IT BUT THIS HAS BEEN AN ON GOING PROBLEM AND IT IS NOT SAFE. IF FORD HAS KNOWN ABOUT THIS FOR THIS LONG OF A TIME IT SHOULD REPAIR THIS PROBLEM OR REPAY ME FOR HAVING IT FIXED.
AT LOW SPEEDS OR IDLING IN TRAFFIC VEHICLE WILL SHUTDOWN AND DIE INTERMITTENTLY. CONSUMER MUST RESTART VEHICLE. DEALER CANNOT DETERMINE CAUSE.*AK
WHILE TRYING TO START VEHICLE, AND AFTER SEVERAL TRIES, VEHICLE WOULD NOT START. DEALER HAS BEEN CONTACTED *AK
A MALFUNCTIONING CHECK VALVE WITHIN THE FUEL PUMP IS CAUSING A PORTION OF UNUSED FUEL TO GO TO ONE TANK, RESULTING IN A FUEL LEAKAGE. ALSO, RECEIVED NHTSA RECALL 93V125000/ DEALER RECALL 93S68 IN REFERENCE TO THE SAME PROBLEM. DEALER REFUSED TO CORRECT THE PROBLEM. OWNER PAID FOR REPAIRS. *AK *ML
TRUCK VIBRATING AT LOW SPEED. TRANSMISSION HAD TO BE REPLACED. THIS IS THE SECOND TIME THE TRANSMISSION HAD TO BE REPLACED. I NEED TO KNOW WHAT KIND OF WARRANTY RIGHTS I HAVE, BECAUSE I FEEL THAT I SHOULD NOT HAVE TO KEEP REPLACING THE TRAMISSION. PLEASE LET ME KNOW WHAT YOU FIND OUT. THANKS. *AK
Official recalls
696V071000 · Electrical System:ignition
Apr 25, 1996
THE IGNITION SWITCH COULD EXPERIENCE AN INTERNAL SHORT CIRCUIT.
Consequence & remedy
Consequence: THIS CONDITION COULD CAUSE OVERHEATING, SMOKE, AND POSSIBLY FIRE IN THE STEERING COLUMN AREA OF THE VEHICLE.
Remedy: DEALERS WILL REPLACE THE IGNITION SWITCH.
94V040000 · Fuel System, Gasoline:delivery:hoses, Lines/piping, And Fittings
Feb 23, 1994
THE STEEL FUEL RETURN TUBES THAT CONNECT THE FRAME FUEL RETURN LINES WITH THE ENGINE FUEL RAIL CAN CONTACT THE PINCH WELD FLANGE CONNECTING THE DASH PANEL TO THE FLOOR PAN. CONTINUED CONTACT LEADS TO ABRASION OF THE STEEL FUEL RETURN TUBE AND EVENTUALLY RESULTS IN A FUEL LEAK.
Consequence & remedy
Consequence: ABRASION OF THE STEEL TUBE WALL THAT EVENTUALLY CAUSES A FUEL LEAK MAY RESULT IN A FIRE, IF A SOURCE OF IGNITION IS PRESENT.
Remedy: FORD DEALERS WILL REPLACE THE FUEL RETURN TUBES WITH FLEXIBLE STAINLESS STEEL BRAIDED/TEFLON TUBES. DEALERS WILL ALSO INSPECT THE FUEL SUPPLY TUBES.
93V125000 · Fuel System, Gasoline:storage:tank Assembly
Aug 2, 1993
A MALFUNCTIONING CHECK VALVE WITHIN THE FUEL PUMP ASSEMBLY CAUSES A PORTION OF THE UNUSED FUEL FROM ONE TANK TO BE RETURNED TO THE SECOND TANK. WHEN THIS OCCURS, THE CAPACITY OF THE SECOND TANK CAN BE EXCEEDED, CAUSING FUEL SPILLAGE.
Consequence & remedy
Consequence: SPILLED FUEL CAN RESULT IN A FIRE WHEN EXPOSED TO ASOURCE OF IGNITION.
Remedy: REPLACEMENT OF THE FUEL PRESSURE REGULATOR AND INSTALLATION OF REDUNDANT CHECK VALVES.
92V026000 · Service Brakes, Hydraulic:foundation Components:drum:shoes/linings
Mar 3, 1992
A REVISED BRAKE LINING NOISE INSULATOR RESULTED IN A DECREASE IN THE THERMAL INSULATION BETWEEN THE BRAKE LINING AND THE FRONT BRAKE CALIPER PISTON. THIS CAUSED GREATER HEAT TRANSFER TO THE CALIPER PISTONS WITH THE POTENTIAL TO OVERHEAT THE BRAKE FLUID AND DIMINISH BRAKE EFFECTIVENESS DURING SEVERE BRAKING CONDITIONS.
Consequence & remedy
Consequence: INCREASED STOPPING DISTANCES AND INABLILITY TO HOLDVEHICLES ON A STEEP GRADE RESULTS IN INCREASED RISK OF ACCIDENT IN THE EVENT OFA SUDDEN STOP OR WHEN CONSTANT BRAKING IS NEEDED TO MANEUVER THROUGH AREAS WITHSTEEP GRADES.
Remedy: ADD SNAP-IN INSULATORS THAT ATTACH TO EACH OF THE FRONT BRAKE CALIPER PISTONS. IN ADDITION, VEHICLES WITH 7.5 L ENGINES WILL HAVE INSULATION ADDED TO THE ENGINE COMPARTMENT BRAKE LINES.
90V101000 · Power Train:automatic Transmission:gear Position Indication (prndl)
Jun 1, 1990
UNDER CERTAIN CONDITIONS, THE SNAP RING THAT LOCATES THE PARK GEAR ON THE OUTPUT SHAFT OF THE TRANSMISSION MAY FRACTURE.
Consequence & remedy
Consequence: WHEN THE GEAR IS PLACED IN PARK, THE PARK GEAR WOULD NOTENGAGE, ALLOWING THE TRUCK TO ROLL FREELY IF THE PARKING BRAKE IS NOT PROPERLYSET. THIS COULD RESULT IN AN ACCIDENT.
Remedy: INSTALL IMPROVED SNAP RING AND REVISED TRANSMISSION EXTENSION HOUSING.
89V141000 · Fuel System, Gasoline:storage:auxillary Tank:selector Devices
Aug 15, 1989
INCORRECTLY INSTALLED FUEL LINE CONNECTORS HAVE FUEL SUPPLY AND RETURN LINES CROSSED.
Consequence & remedy
Consequence: FUEL COULD BE TRANSFERRED FROM ONE TANK TO THE OTHER,POSSIBLY RESULTING IN FUEL OVERFLOW AND SPILLAGE, IN PRESENCE OF AN IGNITIONSOURCE, A FIRE COULD OCCUR.
Remedy: REPLACE FUEL LINE ASSEMBLY.
Model-level recall history does not show whether a particular VIN is affected or has received a repair. Check a VIN with NHTSA ↗
NHTSA investigations
11EA99032 · Dual Fuel Tank Crossflow/leakage
Opened Nov 4, 1999 · Closed Dec 6, 2001
Status: closed (inferred from source dates) · Vehicle Speed Control:linkages
ON JULY 14, 1993 FORD FILED A DEFECT INFORMATION REPORT CONCERNING FUEL TANK CROSS FLOW LEAKAGE ON F-SERIES LIGHT TRUCKS AND CAB CHASSIS BUILT FROM JULY 22, 1989 THROUGH DECEMBER 17, 1992.THE REMEDY WAS TO REPLACE THE FUEL PRESSURE REGULATOR AND INSTALL A CHECK VALVE BETWEEN EACH FUEL SUPPLY LINE AND FUEL TANK (2) TO REPAIR THE SUPPLY SIDE FUEL CROSS FLOW PROBLEM (RECALL 93V-125).ODI OPENED RQ98-008 ON MAY 29, 1998 BECAUSE OF THE LARGE NUMBER OF ALLEGED REMEDY FAILURES AND REPORTS OF FUEL CROSS FLOW ON VEHICLES OUTSIDE OF THE RECALL POPULATION.BASED ONTHE INFORMATION RECEIVED FROM FORD ON AUGUST 11, SEPTEMBER 30, AND DECEMBER 15, 1998, AND THE INCREASING TREND OF REMEDY FAILURES AND OUT OF SCOPE CROSSFLOW REPORTS, ODI OPENED EA99-032 ON NOVEMBER 4, 1999.THE ATTACHED ENGINEERING ANALYSIS CLOSING REPORT FULLY DESCRIBES THE RESULTS OF THIS INVESTIGATION AND REASON FOR CLOSING.THE SUBJECT VEHICLES CAN EXPERIENCE FUEL TRANSFER FROM ONE TANK TO THE OTHER DUE TO MALFUNCTIONS IN THE FUEL SYSTEM.WHEN FUEL IS PUMPED OR RETURNED TO THE NON-OPERATING TANK (CROSS FLOW), THE CAPACITY OF THE NON-OPERATING TANK CAN BE EXCEEDED, CAUSING FUEL TO OVERFLOW PAST THE FILLER CAP, CREATING A FIRE POTENTIAL.
Additional source detail variants (2)
Vehicle Speed Control:linkages
ON JULY 14, 1993 FORD FILED A DEFECT INFORMATION REPORT CONCERNING FUEL TANK CROSS FLOW LEAKAGE ON F-SERIES LIGHT TRUCKS AND CAB CHASSIS BUILT FROM JULY 22, 1989 THROUGH DECEMBER 17, 1992.THE REMEDY WAS TO REPLACE THE FUEL PRESSURE REGULATOR AND INSTALL A CHECK VALVE BETWEEN EACH FUEL SUPPLY LINE AND FUEL TANK (2) TO REPAIR THE SUPPLY SIDE FUEL CROSS FLOW PROBLEM (RECALL 93V-125).ODI OPENED RQ98-008 ON MAY 29, 1998 BECAUSE OF THE LARGE NUMBER OF ALLEGED REMEDY FAILURES AND REPORTS OF FUEL CROSS FLOW ON VEHICLES OUTSIDE OF THE RECALL POPULATION.BASED ONTHE INFORMATION RECEIVED FROM FORD ON AUGUST 11, SEPTEMBER 30, AND DECEMBER 15, 1998, AND THE INCREASING TREND OF REMEDY FAILURES AND OUT OF SCOPE CROSSFLOW REPORTS, ODI OPENED EA99-032 ON NOVEMBER 4, 1999.THE ATTACHED ENGINEERING ANALYSIS CLOSING REPORT FULLY DESCRIBES THE RESULTS OF THIS INVESTIGATION AND REASON FOR CLOSING.THE SUBJECT VEHICLES CAN EXPERIENCE FUEL TRANSFER FROM ONE TANK TO THE OTHER DUE TO MALFUNCTIONS IN THE FUEL SYSTEM.WHEN FUEL IS PUMPED OR RETURNED TO THE NON-OPERATING TANK (CROSS FLOW), THE CAPACITY OF THE NON-OPERATING TANK CAN BE EXCEEDED, CAUSING FUEL TO OVERFLOW PAST THE FILLER CAP, CREATING A FIRE POTENTIAL.
Vehicle Speed Control:linkages
ON JULY 14, 1993 FORD FILED A DEFECT INFORMATION REPORT CONCERNING FUEL TANK CROSS FLOW LEAKAGE ON F-SERIES LIGHT TRUCKS AND CAB CHASSIS BUILT FROM JULY 22, 1989 THROUGH DECEMBER 17, 1992.THE REMEDY WAS TO REPLACE THE FUEL PRESSURE REGULATOR AND INSTALL A CHECK VALVE BETWEEN EACH FUEL SUPPLY LINE AND FUEL TANK (2) TO REPAIR THE SUPPLY SIDE FUEL CROSS FLOW PROBLEM (RECALL 93V-125).ODI OPENED RQ98-008 ON MAY 29, 1998 BECAUSE OF THE LARGE NUMBER OF ALLEGED REMEDY FAILURES AND REPORTS OF FUEL CROSS FLOW ON VEHICLES OUTSIDE OF THE RECALL POPULATION.BASED ONTHE INFORMATION RECEIVED FROM FORD ON AUGUST 11, SEPTEMBER 30, AND DECEMBER 15, 1998, AND THE INCREASING TREND OF REMEDY FAILURES AND OUT OF SCOPE CROSSFLOW REPORTS, ODI OPENED EA99-032 ON NOVEMBER 4, 1999.THE ATTACHED ENGINEERING ANALYSIS CLOSING REPORT FULLY DESCRIBES THE RESULTS OF THIS INVESTIGATION AND REASON FOR CLOSING.THE SUBJECT VEHICLES CAN EXPERIENCE FUEL TRANSFER FROM ONE TANK TO THE OTHER DUE TO MALFUNCTIONS IN THE FUEL SYSTEM.WHEN FUEL IS PUMPED OR RETURNED TO THE NON-OPERATING TANK (CROSS FLOW), THE CAPACITY OF THE NON-OPERATING TANK CAN BE EXCEEDED, CAUSING FUEL TO OVERFLOW PAST THE FILLER CAP, CREATING A FIRE POTENTIAL.
RQ98008 · Ford F-SERIES Dual Fuel Tank Leakage
Opened May 29, 1998 · Closed Nov 4, 1999
Status: closed (inferred from source dates) · Fuel System, Gasoline:storage:tank Assembly
THESE VEHICLES CAN EXPERIENCE FUEL TRANSFER FROM ONE TANK TO THE OTHER DUE TO A MALFUNCTIONING FUEL PUMP.FROM THE INFORMATION GATHERED TO DATE, IT APPEARS THAT THERE CAN BE MULTIPLE CAUSES AND/OR A COMBINATION OF CAUSES FOR FUEL CROSS FLOW AND THAT THE RECALL REMEDY MAY BE INADEQUATE.FURTHER INVESTIGATION IS NEEDED.THIS INVESTIGATION IS UPGRADED TO EA99-032.CLICK ON DOCUMENT SEARCH BUTTON FOR ADDITIONAL INFORMATION.
EA93026 · Fuel Line Routing
Opened Oct 29, 1993 · Closed Feb 28, 1994
Status: closed (inferred from source dates) · Vehicle Speed Control:linkages
There is no summary currently available
EA93014 · Alternator Belt Failure
Opened Jun 4, 1993 · Closed Jul 29, 1994
Status: closed (inferred from source dates) · Electrical System
There is no summary currently available
EA93001 · Fuel Expulsion
Opened Jan 7, 1993 · Closed Aug 20, 1993
Status: closed (inferred from source dates) · Vehicle Speed Control:linkages
There is no summary currently available
PE92077 · Fuel Expulsion
Opened Sep 9, 1992 · Closed Jan 7, 1993
Status: closed (inferred from source dates) · Vehicle Speed Control:linkages
There is no summary currently available
EA91044 · Loss Of Brake Effectivenes
Opened Oct 30, 1991 · Closed Oct 30, 1992
Status: closed (inferred from source dates) · Service Brakes, Hydraulic
===
EA91031 · Fuel Expulsion
Opened Jun 26, 1991 · Closed Nov 1, 1991
Status: closed (inferred from source dates) · Vehicle Speed Control:linkages
There is no summary currently available
PE91090 · Spare Tire Fires
Opened Jun 20, 1991 · Closed Oct 25, 1991
Status: closed (inferred from source dates) · Equipment
There is no summary currently available
PE91077 · Loss Of Brake Effectivenes
Opened May 23, 1991 · Closed Oct 31, 1991
Status: closed (inferred from source dates) · Service Brakes, Hydraulic
There is no summary currently available
PE91064 · Transmission Fluid Fires
Opened Apr 9, 1991 · Closed Jul 5, 1991
Status: closed (inferred from source dates) · Power Train
There is no summary currently available
Illustration