What owners actually said
254 reportsMileage unknown · May 8, 2007
Fuel System, Gasoline
TL*THE CONTACT OWNS A 1990 FORD F150. THE CONTACT STATED THAT THERE IS AN OVERFLOW OF GAS IN THE REAR TANK FROM THE FRONT TANK. WHEN THIS OCCURS, THE SECOND TANK REACHES ITS MAXIMUM CAPACITY AND CAUSES FUEL SPILLAGE. THIS FAILURE HAS OCCURRED APPROXIMATELY FIVE TIMES. THE DEALER HAS NOT INSPECTED THE VEHICLE TO DETERMINE THE…
Read full complaint
TL*THE CONTACT OWNS A 1990 FORD F150. THE CONTACT STATED THAT THERE IS AN OVERFLOW OF GAS IN THE REAR TANK FROM THE FRONT TANK. WHEN THIS OCCURS, THE SECOND TANK REACHES ITS MAXIMUM CAPACITY AND CAUSES FUEL SPILLAGE. THIS FAILURE HAS OCCURRED APPROXIMATELY FIVE TIMES. THE DEALER HAS NOT INSPECTED THE VEHICLE TO DETERMINE THE CAUSE OF FAILURE. THERE WAS A RECALL # 93V125000 (FUEL SYSTEM, GASOLINE:STORAGE:TANK ASSEMBLY) FOR THIS FAILURE IN 1990. THE CONTACT STATED THAT HIS VEHICLE WAS SERVICED FOR THIS RECALL IN 1993. THE CURRENT MILEAGE IS 145,000 AND THE FAILURE MILEAGE WAS UNKNOWN.
NHTSA ODI #10190175
120,000 miles · Apr 10, 2007
Fuel System, Gasoline
TL*THE CONTACT OWNS A 1990 FORD F150. THE CONTACT STATED THAT THERE WAS SAFETY RECALL # 01I008000, WHICH HAD BEEN EXTENDED 12 YEARS. HOWEVER, THE DEALER AND MANUFACTURER STATED THAT NO RECALL EXISTED. ALL THE CONTACT KNEW WAS THAT THE VEHICLE WAS LEAKING FLUID. THE CURRENT AND FAILURE MILEAGE WERE 120,000. *AK
NHTSA ODI #10187456
53,227 miles · Jan 29, 2007
Steering
THE PIN THAT POSITIONS THE TILT STEERING WHEEL BROKE ALLOWING THE STEERING WHEEL TO FLOP UP AND DOWN. THIS OCCURRED WHILE DRIVING. *NM
NHTSA ODI #10181013
189,000 miles · Apr 11, 2006
Fuel System, Gasoline
THE FUEL STARTED TO RUN OUT OF THE FRONT FUEL TANK. I LOST MOST OF THE FUEL OUT OF THE REAR TANK THAT SPILLED ON THE ROAD. I THINK THAT THIS IS A FIRE WAITING TO HAPPEN. NOW I DO NOT USE THE REAR TANK TO STOP THE PROBLEM. I HAVE NOT FIXED THE PROBLEM BECAUSE FORD HAS HAD THIS PROBLEM WITH MANY OF THERE TRUCKS AND THEY SHOULD FI…
Read full complaint
THE FUEL STARTED TO RUN OUT OF THE FRONT FUEL TANK. I LOST MOST OF THE FUEL OUT OF THE REAR TANK THAT SPILLED ON THE ROAD. I THINK THAT THIS IS A FIRE WAITING TO HAPPEN. NOW I DO NOT USE THE REAR TANK TO STOP THE PROBLEM. I HAVE NOT FIXED THE PROBLEM BECAUSE FORD HAS HAD THIS PROBLEM WITH MANY OF THERE TRUCKS AND THEY SHOULD FIX A FUEL PROBLEM. THAT HAS HAPPENED IN MANY OF THERE TRUCKS NO MATTER OF THE MILEAGE OR AGE. *JB
NHTSA ODI #10155113
Mileage unknown · Feb 27, 2006
Fuel System, Gasoline
GASOLINE BACK UP AND FLOWING OUT BACK TANK, FROM GAS CAP. *JB
NHTSA ODI #10151285
126,000 miles · Oct 6, 2005
Fuel System, Gasoline
DT: THE CONTACT STATED THAT WHEN FILLING UP THE REAR FUEL TANK IT WOULD PUMP THE GAS INTO THE FRONT TANK. THE GAS OVERFLOWS OUT ONTO THE SIDE OF THE VEHICLE ONCE THE CONSUMER WOULD START TO DRIVE. THE CONTACT NOTICED THIS ON 9-2-05. HE CONTACTED FORD AND THEY SAID THAT THE RECALL O1I008000 HAD EXPIRED. *AK *MR
NHTSA ODI #10135892
15,000 miles · Aug 1, 2005
Fuel System, GasolineFire
EVENTS LEADING UP TO EXPLOSION AND FIRE. *JB
NHTSA ODI #10130773
Mileage unknown · Jul 19, 2005
Tires
DROVE NEW VEHICLE WITH 1475 # TRUCK CAMPER WITHOUT INCIDENT 12 YEARS. REPLACED 4 TIRES, DIFFERENT BRAND, SAME SPECS. L REAR FAILED 4/15/05 AFTER 14,034 MILES ON TIRE.R REAR FAILED ON BELOW DATE WITH 16,102 MILES ON THE TIRE.
NHTSA ODI #10129376
149,993 miles · Jun 6, 2005
Fuel System, Gasoline
I HAVE A 1990 FORD F150 TRUCK. ON 3 DIFFERENT OCCASIONS FUEL FROM THE BACK TANK HAS FLOWED OVER INTO THE FRONT TANK. ON ALL THREE OCCASIONS, I HAVE GONE TO MY TRUCK TO FIND GASOLINE ALL OVER THE GROUND. I STILL HAD TO PUT A BUCKET UNDER THE TANKS FILLERS TO ALLOW THE EXCESS GAS IN THE FRONT TANK TO FLOW DOWN.ON TWO OCCASIONS I H…
Read full complaint
I HAVE A 1990 FORD F150 TRUCK. ON 3 DIFFERENT OCCASIONS FUEL FROM THE BACK TANK HAS FLOWED OVER INTO THE FRONT TANK. ON ALL THREE OCCASIONS, I HAVE GONE TO MY TRUCK TO FIND GASOLINE ALL OVER THE GROUND. I STILL HAD TO PUT A BUCKET UNDER THE TANKS FILLERS TO ALLOW THE EXCESS GAS IN THE FRONT TANK TO FLOW DOWN.ON TWO OCCASIONS I HAD THE TRUCK PARKED IN THE GARAGE. THE GAS THAT FLOWED OUT COVERED ALMOST MY ENTIRE GARAGE FLOOR. ON THE THIRD OCCASION, ENOUGH GAS HAD FLOWED FROM THE TANK TO REACH MY LAWN. IF SOMEONE HAD COME TO MY HOME SMOKING, OR SOME OTHER IGNITION SOURCE WAS TO HAVE COME IN CONTACT WITH IT, MY HOUSE WOULD HAVE BURNED TO THE GROUND. I NOW HAVE TO PARK THE TRUCK OUTSIDE FOR FEAR OF IT CAUSING MY HOUSE TO BURN.
NHTSA ODI #10124401
60,000 miles · Mar 16, 2005
Fuel System, GasolineInjury
I OWN A 1990 FORD F-150 WITH RECALL # 93S68. THIS IS A CROSS DUAL TANK FUEL CONDITION WHERE THE FRONT TANK OVERLOADS WITH UNUSED FUEL . FRONT TANK IS IN-OPERABLE AND ONLY REAR TANK BEING USED. FRONT TANK CONTINUES TO SPILL FUEL WHEN PARKED AND AFTER 6 YRS OF REPEATED ATTEMPTS IN CONTACT WITH FORD I STILL CAN GET NO RELIEF. I HAV…
Read full complaint
I OWN A 1990 FORD F-150 WITH RECALL # 93S68. THIS IS A CROSS DUAL TANK FUEL CONDITION WHERE THE FRONT TANK OVERLOADS WITH UNUSED FUEL . FRONT TANK IS IN-OPERABLE AND ONLY REAR TANK BEING USED. FRONT TANK CONTINUES TO SPILL FUEL WHEN PARKED AND AFTER 6 YRS OF REPEATED ATTEMPTS IN CONTACT WITH FORD I STILL CAN GET NO RELIEF. I HAVE HAD 2 93S68 RECALLS AND STILL THE TANK LEAKS DANGEROUS GASOLINE EVERYWHERE IT IS PARKED. WHAT AMAZES ME IS HOW FORD HAS BURIED THIS RECALL CONSIDERING WHAT A HAZARD LEAKING FUEL PRESENTS. HAVING OWNED THE TRUCK FOR 10 YRS AND SINCE IT IS IN OTHERWISE PERFECT CONDITION , I AM HOPING AN AGENCY SUCH AS YOURS WOULD HELP ME TO FORCE FORD TO HONOR THIS RECALL UNTIL I AM SATISFIED. PLEASE CONTACT ME AT ANY TIME AT THE 2 PH3'S PROVIDED . THIS IS THE SECOND TIME I HAVE TRIED TO ENLIST THE ASSIST OF NHTSA . *AK
NHTSA ODI #10114173
NHTSA investigations
10EA99032 · Dual Fuel Tank Crossflow/leakage
Opened Nov 4, 1999 · Closed Dec 6, 2001
Status: closed (inferred from source dates) · Vehicle Speed Control:linkages
ON JULY 14, 1993 FORD FILED A DEFECT INFORMATION REPORT CONCERNING FUEL TANK CROSS FLOW LEAKAGE ON F-SERIES LIGHT TRUCKS AND CAB CHASSIS BUILT FROM JULY 22, 1989 THROUGH DECEMBER 17, 1992.THE REMEDY WAS TO REPLACE THE FUEL PRESSURE REGULATOR AND INSTALL A CHECK VALVE BETWEEN EACH FUEL SUPPLY LINE AND FUEL TANK (2) TO REPAIR THE SUPPLY SIDE FUEL CROSS FLOW PROBLEM (RECALL 93V-125).ODI OPENED RQ98-008 ON MAY 29, 1998 BECAUSE OF THE LARGE NUMBER OF ALLEGED REMEDY FAILURES AND REPORTS OF FUEL CROSS FLOW ON VEHICLES OUTSIDE OF THE RECALL POPULATION.BASED ONTHE INFORMATION RECEIVED FROM FORD ON AUGUST 11, SEPTEMBER 30, AND DECEMBER 15, 1998, AND THE INCREASING TREND OF REMEDY FAILURES AND OUT OF SCOPE CROSSFLOW REPORTS, ODI OPENED EA99-032 ON NOVEMBER 4, 1999.THE ATTACHED ENGINEERING ANALYSIS CLOSING REPORT FULLY DESCRIBES THE RESULTS OF THIS INVESTIGATION AND REASON FOR CLOSING.THE SUBJECT VEHICLES CAN EXPERIENCE FUEL TRANSFER FROM ONE TANK TO THE OTHER DUE TO MALFUNCTIONS IN THE FUEL SYSTEM.WHEN FUEL IS PUMPED OR RETURNED TO THE NON-OPERATING TANK (CROSS FLOW), THE CAPACITY OF THE NON-OPERATING TANK CAN BE EXCEEDED, CAUSING FUEL TO OVERFLOW PAST THE FILLER CAP, CREATING A FIRE POTENTIAL.
Additional source detail variants (2)
Vehicle Speed Control:linkages
ON JULY 14, 1993 FORD FILED A DEFECT INFORMATION REPORT CONCERNING FUEL TANK CROSS FLOW LEAKAGE ON F-SERIES LIGHT TRUCKS AND CAB CHASSIS BUILT FROM JULY 22, 1989 THROUGH DECEMBER 17, 1992.THE REMEDY WAS TO REPLACE THE FUEL PRESSURE REGULATOR AND INSTALL A CHECK VALVE BETWEEN EACH FUEL SUPPLY LINE AND FUEL TANK (2) TO REPAIR THE SUPPLY SIDE FUEL CROSS FLOW PROBLEM (RECALL 93V-125).ODI OPENED RQ98-008 ON MAY 29, 1998 BECAUSE OF THE LARGE NUMBER OF ALLEGED REMEDY FAILURES AND REPORTS OF FUEL CROSS FLOW ON VEHICLES OUTSIDE OF THE RECALL POPULATION.BASED ONTHE INFORMATION RECEIVED FROM FORD ON AUGUST 11, SEPTEMBER 30, AND DECEMBER 15, 1998, AND THE INCREASING TREND OF REMEDY FAILURES AND OUT OF SCOPE CROSSFLOW REPORTS, ODI OPENED EA99-032 ON NOVEMBER 4, 1999.THE ATTACHED ENGINEERING ANALYSIS CLOSING REPORT FULLY DESCRIBES THE RESULTS OF THIS INVESTIGATION AND REASON FOR CLOSING.THE SUBJECT VEHICLES CAN EXPERIENCE FUEL TRANSFER FROM ONE TANK TO THE OTHER DUE TO MALFUNCTIONS IN THE FUEL SYSTEM.WHEN FUEL IS PUMPED OR RETURNED TO THE NON-OPERATING TANK (CROSS FLOW), THE CAPACITY OF THE NON-OPERATING TANK CAN BE EXCEEDED, CAUSING FUEL TO OVERFLOW PAST THE FILLER CAP, CREATING A FIRE POTENTIAL.
Vehicle Speed Control:linkages
ON JULY 14, 1993 FORD FILED A DEFECT INFORMATION REPORT CONCERNING FUEL TANK CROSS FLOW LEAKAGE ON F-SERIES LIGHT TRUCKS AND CAB CHASSIS BUILT FROM JULY 22, 1989 THROUGH DECEMBER 17, 1992.THE REMEDY WAS TO REPLACE THE FUEL PRESSURE REGULATOR AND INSTALL A CHECK VALVE BETWEEN EACH FUEL SUPPLY LINE AND FUEL TANK (2) TO REPAIR THE SUPPLY SIDE FUEL CROSS FLOW PROBLEM (RECALL 93V-125).ODI OPENED RQ98-008 ON MAY 29, 1998 BECAUSE OF THE LARGE NUMBER OF ALLEGED REMEDY FAILURES AND REPORTS OF FUEL CROSS FLOW ON VEHICLES OUTSIDE OF THE RECALL POPULATION.BASED ONTHE INFORMATION RECEIVED FROM FORD ON AUGUST 11, SEPTEMBER 30, AND DECEMBER 15, 1998, AND THE INCREASING TREND OF REMEDY FAILURES AND OUT OF SCOPE CROSSFLOW REPORTS, ODI OPENED EA99-032 ON NOVEMBER 4, 1999.THE ATTACHED ENGINEERING ANALYSIS CLOSING REPORT FULLY DESCRIBES THE RESULTS OF THIS INVESTIGATION AND REASON FOR CLOSING.THE SUBJECT VEHICLES CAN EXPERIENCE FUEL TRANSFER FROM ONE TANK TO THE OTHER DUE TO MALFUNCTIONS IN THE FUEL SYSTEM.WHEN FUEL IS PUMPED OR RETURNED TO THE NON-OPERATING TANK (CROSS FLOW), THE CAPACITY OF THE NON-OPERATING TANK CAN BE EXCEEDED, CAUSING FUEL TO OVERFLOW PAST THE FILLER CAP, CREATING A FIRE POTENTIAL.
RQ98008 · Ford F-SERIES Dual Fuel Tank Leakage
Opened May 29, 1998 · Closed Nov 4, 1999
Status: closed (inferred from source dates) · Fuel System, Gasoline:storage:tank Assembly
THESE VEHICLES CAN EXPERIENCE FUEL TRANSFER FROM ONE TANK TO THE OTHER DUE TO A MALFUNCTIONING FUEL PUMP.FROM THE INFORMATION GATHERED TO DATE, IT APPEARS THAT THERE CAN BE MULTIPLE CAUSES AND/OR A COMBINATION OF CAUSES FOR FUEL CROSS FLOW AND THAT THE RECALL REMEDY MAY BE INADEQUATE.FURTHER INVESTIGATION IS NEEDED.THIS INVESTIGATION IS UPGRADED TO EA99-032.CLICK ON DOCUMENT SEARCH BUTTON FOR ADDITIONAL INFORMATION.
EA93001 · Fuel Expulsion
Opened Jan 7, 1993 · Closed Aug 20, 1993
Status: closed (inferred from source dates) · Vehicle Speed Control:linkages
There is no summary currently available
PE92077 · Fuel Expulsion
Opened Sep 9, 1992 · Closed Jan 7, 1993
Status: closed (inferred from source dates) · Vehicle Speed Control:linkages
There is no summary currently available
EA92029 · Front Seat Back Failure
Opened Aug 27, 1992 · Closed Oct 29, 1993
Status: closed (inferred from source dates) · Seats
There is no summary currently available
EA91044 · Loss Of Brake Effectivenes
Opened Oct 30, 1991 · Closed Oct 30, 1992
Status: closed (inferred from source dates) · Service Brakes, Hydraulic
===
EA91031 · Fuel Expulsion
Opened Jun 26, 1991 · Closed Nov 1, 1991
Status: closed (inferred from source dates) · Vehicle Speed Control:linkages
There is no summary currently available
PE91077 · Loss Of Brake Effectivenes
Opened May 23, 1991 · Closed Oct 31, 1991
Status: closed (inferred from source dates) · Service Brakes, Hydraulic
There is no summary currently available
PE91064 · Transmission Fluid Fires
Opened Apr 9, 1991 · Closed Jul 5, 1991
Status: closed (inferred from source dates) · Power Train
There is no summary currently available
PE91017 · Ford Truck Inconsistent Vehicle Control.
Opened Nov 27, 1990 · Closed Apr 17, 1991
Status: closed (inferred from source dates) · Service Brakes, Hydraulic
SEE CLOSE RESUME