DROVE NEW VEHICLE WITH 1475 # TRUCK CAMPER WITHOUT INCIDENT 12 YEARS. REPLACED 4 TIRES, DIFFERENT BRAND, SAME SPECS. L REAR FAILED 4/15/05 AFTER 14,034 MILES ON TIRE.R REAR FAILED ON BELOW DATE WITH 16,102 MILES ON THE TIRE.
1990 Ford F150
Owner reports · Recalls · Investigations
Limited comparison data
There is not enough comparable history to draw a useful model-year comparison.
About this comparison →How this year compares
Owner complaints by model year
Compare all F150 years →Counts vary with age, sales and reporting. They are not failure rates.
What owners reported most
All reported categories
Tap a category to read its complaints. One report may name several components.
When problems were reported
Mileage at the reported incident
Limited mileage data: 25 of 254 reports include usable mileage. There isn’t enough coverage to show a useful chart.
NHTSA’s mileage field refers to the reported incident, not necessarily the filing date. This shows report counts, not the likelihood of a failure.
What to inspect
Issues worth paying extra attention to based on owner reports.
- Fuel System, Gasoline. Review the 129 owner reports in this category and discuss these concerns during a pre-purchase inspection. Read reports →
- Electrical System. Review the 34 owner reports in this category and discuss these concerns during a pre-purchase inspection. Read reports →
- Engine And Engine Cooling. Review the 20 owner reports in this category and discuss these concerns during a pre-purchase inspection. Read reports →
NHTSA owner reports · September 18, 2026 snapshot.
Tires complaints
19 reportsWHILE DRIVING AT 55 MPH RIGHT REAR TIRE BLEW OUT AND EXPLODED, DAMAGING THE RIM. THE OCCURRED BECAUSE THE STEEL CORD BROKE AND THE TIRE DEVELOPED A KNOT. THIS WAS THIRD TIRE BLOWOUT DUE TO THE SAME FAILURE. *AK *NM
WHILE DRIVING 50 MPH ON THE HIGHWAY WITHOUT WARNING, THE RIGHT REAR TIRE EXPLODED INTO FLAMES. THE RIM OF THE WHEEL WAS SO HOT YOU COULD NOT TOUCH IT BY HAND. THE CONSUMER WAS ABLE TO PULL OVER TO THE SHOULDER TO CHANGE THE TIRE. THE TIRE WAS A FIRESTONE #ATX P2335R75/R15 PLEASE FILL IN THE DOT # AND FURTHER INFORMATION ON TH…
Read full complaint
WHILE DRIVING 50 MPH ON THE HIGHWAY WITHOUT WARNING, THE RIGHT REAR TIRE EXPLODED INTO FLAMES. THE RIM OF THE WHEEL WAS SO HOT YOU COULD NOT TOUCH IT BY HAND. THE CONSUMER WAS ABLE TO PULL OVER TO THE SHOULDER TO CHANGE THE TIRE. THE TIRE WAS A FIRESTONE #ATX P2335R75/R15 PLEASE FILL IN THE DOT # AND FURTHER INFORMATION ON THIS INCIDENT. THERE WERE NO INJURIES OR FATALITY TO REPORT. *PH
TOTAL TREAD SEPARATION - TIRE INFLATED TO PRECISELY RECOMMENDED PRESSURE 41PSI - DAMAGE TO VEHICLE - SWERVED INTO ONCOMING LANE- NO ACCIDENT. *AK
WAS DRIVING 75MPH WHEN RIGHT REAR TIRE WENT FLAT. MANAGED TO STOP VEHICLE AND CHECK TIRES. VALVE STEM HAD DRY ROTTED AND FELL OFF. WAS NO WHERE NEAR OR IN TIRE. THIS CAUSED AIR TO LEAK OUT, AND TIRE FLATTENED IN A MATTER OF SECONDS. AT 15000 MILES , FOURTH ALSO HAD CRACKS IN ITS VALVE STEM. SECOND AND THIRD TIRES VALVE STEM…
Read full complaint
WAS DRIVING 75MPH WHEN RIGHT REAR TIRE WENT FLAT. MANAGED TO STOP VEHICLE AND CHECK TIRES. VALVE STEM HAD DRY ROTTED AND FELL OFF. WAS NO WHERE NEAR OR IN TIRE. THIS CAUSED AIR TO LEAK OUT, AND TIRE FLATTENED IN A MATTER OF SECONDS. AT 15000 MILES , FOURTH ALSO HAD CRACKS IN ITS VALVE STEM. SECOND AND THIRD TIRES VALVE STEM WAS SPLITTING.*AK
TIRES ON MY F150 SHOW ABNORMAL WEAR ON THE OUTSIDE EDGES. FORD SAYS THIS IS DUE TO THE SUSPENSION. FORD DOES NOT HAVE A FIX. I CLAIM THAT THIS IS A SUSPENSION ISSUE, NOT A TIRE ISSUE. I HAVE SINCE BOUGHT A NEW CHECROLET TAHOE. COULD THIS ISSUE BE RELATED TO THE TIRE ISSUES ON CURRENT FORD SUV'S? I THINK THAT THE TIRES ARE NOT TH…
Read full complaint
TIRES ON MY F150 SHOW ABNORMAL WEAR ON THE OUTSIDE EDGES. FORD SAYS THIS IS DUE TO THE SUSPENSION. FORD DOES NOT HAVE A FIX. I CLAIM THAT THIS IS A SUSPENSION ISSUE, NOT A TIRE ISSUE. I HAVE SINCE BOUGHT A NEW CHECROLET TAHOE. COULD THIS ISSUE BE RELATED TO THE TIRE ISSUES ON CURRENT FORD SUV'S? I THINK THAT THE TIRES ARE NOT THE PROBLEM RATHER FORD SUPSPENSION IS THE PROBLEM THAT CAUSES ABNORMAL TIRE WEAR AND HEATING OF THE TIRES, ESP. IN TEXAS. THIS WEARS THE OUTER EDGES OF THE TIRES, EVENTUALLY CAUSING THE OUTER TREAD TO FAIL OR SEPERATE FROM THE TIRE. THIS IS A DEFINATE PROBLEM ON THE FORD F150 TRUCKS, AND I THINK IT APPLIES TO THE EXPLORER.*AK (TIRESIZE: P235R15)( DOT NUMBER: TIRE SIZE: P235R15 )
WHILE TRAVELING AT APPROXIMATELY 72 MPH WITH CRUISE CONTROL IN FORD F150 1990 RIGHT REAR TIRE EXPERIENCED COMPLETE TREAD SEPARATION, CAUSING DAMAGE TO TAILPIPE AND QUARTER PANEL OF VEHICLE. THIS TIRE WAS NOT ORIGINAL EQUIPMENT ON VEHICLE. FIRESTONE TIRE, FR480, SIZE: P235/75R15.*AK
30X9.50R15 IS THE SIZE OF THE BRIDGESTONE DAYTONA RADIAL TIRE THAT IS EQUIPPED ON THIS FORD, F150 1990. TIRES STILL LOOK NEAR BRAND NEW, AND TREAD HAS STARTED TO SEPARATE. BRIDGESTONE HAS BEEN CONTACTED.*AK DOT # IS VD666TA046. *SLC
HAVE HAD 4 OF 8 BFGOODRICH TIRES THAT I PURCHASED, EITHER BUBBLE OR DELAMINATE. LAST ONE TO DELAMINATE CAUSED EXTENSIVE DAMAGE TO VEHICLE (486.49 REPAIR BILL) I WILL FAX LETTER THAT I WROTE TO BFGOODRICH TO YOU.10-4 2000 5PM (DOT NUMBER: BE608L1012 TIRESIZE: 31X10.5R15)
TREAD SEPERATION AND ANOTHER FIXEN TO COME OFF (DOT NUMBER: VDHL1PA375 TIRESIZE: P235/75R15)
Official recalls
496V071000 · Electrical System:ignition
Apr 25, 1996
THE IGNITION SWITCH COULD EXPERIENCE AN INTERNAL SHORT CIRCUIT.
Consequence & remedy
Consequence: THIS CONDITION COULD CAUSE OVERHEATING, SMOKE, AND POSSIBLY FIRE IN THE STEERING COLUMN AREA OF THE VEHICLE.
Remedy: DEALERS WILL REPLACE THE IGNITION SWITCH.
93V125000 · Fuel System, Gasoline:storage:tank Assembly
Aug 2, 1993
A MALFUNCTIONING CHECK VALVE WITHIN THE FUEL PUMP ASSEMBLY CAUSES A PORTION OF THE UNUSED FUEL FROM ONE TANK TO BE RETURNED TO THE SECOND TANK. WHEN THIS OCCURS, THE CAPACITY OF THE SECOND TANK CAN BE EXCEEDED, CAUSING FUEL SPILLAGE.
Consequence & remedy
Consequence: SPILLED FUEL CAN RESULT IN A FIRE WHEN EXPOSED TO ASOURCE OF IGNITION.
Remedy: REPLACEMENT OF THE FUEL PRESSURE REGULATOR AND INSTALLATION OF REDUNDANT CHECK VALVES.
90V101000 · Power Train:automatic Transmission:gear Position Indication (prndl)
Jun 1, 1990
UNDER CERTAIN CONDITIONS, THE SNAP RING THAT LOCATES THE PARK GEAR ON THE OUTPUT SHAFT OF THE TRANSMISSION MAY FRACTURE.
Consequence & remedy
Consequence: WHEN THE GEAR IS PLACED IN PARK, THE PARK GEAR WOULD NOTENGAGE, ALLOWING THE TRUCK TO ROLL FREELY IF THE PARKING BRAKE IS NOT PROPERLYSET. THIS COULD RESULT IN AN ACCIDENT.
Remedy: INSTALL IMPROVED SNAP RING AND REVISED TRANSMISSION EXTENSION HOUSING.
89V141000 · Fuel System, Gasoline:storage:auxillary Tank:selector Devices
Aug 15, 1989
INCORRECTLY INSTALLED FUEL LINE CONNECTORS HAVE FUEL SUPPLY AND RETURN LINES CROSSED.
Consequence & remedy
Consequence: FUEL COULD BE TRANSFERRED FROM ONE TANK TO THE OTHER,POSSIBLY RESULTING IN FUEL OVERFLOW AND SPILLAGE, IN PRESENCE OF AN IGNITIONSOURCE, A FIRE COULD OCCUR.
Remedy: REPLACE FUEL LINE ASSEMBLY.
Model-level recall history does not show whether a particular VIN is affected or has received a repair. Check a VIN with NHTSA ↗
NHTSA investigations
10EA99032 · Dual Fuel Tank Crossflow/leakage
Opened Nov 4, 1999 · Closed Dec 6, 2001
Status: closed (inferred from source dates) · Vehicle Speed Control:linkages
ON JULY 14, 1993 FORD FILED A DEFECT INFORMATION REPORT CONCERNING FUEL TANK CROSS FLOW LEAKAGE ON F-SERIES LIGHT TRUCKS AND CAB CHASSIS BUILT FROM JULY 22, 1989 THROUGH DECEMBER 17, 1992.THE REMEDY WAS TO REPLACE THE FUEL PRESSURE REGULATOR AND INSTALL A CHECK VALVE BETWEEN EACH FUEL SUPPLY LINE AND FUEL TANK (2) TO REPAIR THE SUPPLY SIDE FUEL CROSS FLOW PROBLEM (RECALL 93V-125).ODI OPENED RQ98-008 ON MAY 29, 1998 BECAUSE OF THE LARGE NUMBER OF ALLEGED REMEDY FAILURES AND REPORTS OF FUEL CROSS FLOW ON VEHICLES OUTSIDE OF THE RECALL POPULATION.BASED ONTHE INFORMATION RECEIVED FROM FORD ON AUGUST 11, SEPTEMBER 30, AND DECEMBER 15, 1998, AND THE INCREASING TREND OF REMEDY FAILURES AND OUT OF SCOPE CROSSFLOW REPORTS, ODI OPENED EA99-032 ON NOVEMBER 4, 1999.THE ATTACHED ENGINEERING ANALYSIS CLOSING REPORT FULLY DESCRIBES THE RESULTS OF THIS INVESTIGATION AND REASON FOR CLOSING.THE SUBJECT VEHICLES CAN EXPERIENCE FUEL TRANSFER FROM ONE TANK TO THE OTHER DUE TO MALFUNCTIONS IN THE FUEL SYSTEM.WHEN FUEL IS PUMPED OR RETURNED TO THE NON-OPERATING TANK (CROSS FLOW), THE CAPACITY OF THE NON-OPERATING TANK CAN BE EXCEEDED, CAUSING FUEL TO OVERFLOW PAST THE FILLER CAP, CREATING A FIRE POTENTIAL.
Additional source detail variants (2)
Vehicle Speed Control:linkages
ON JULY 14, 1993 FORD FILED A DEFECT INFORMATION REPORT CONCERNING FUEL TANK CROSS FLOW LEAKAGE ON F-SERIES LIGHT TRUCKS AND CAB CHASSIS BUILT FROM JULY 22, 1989 THROUGH DECEMBER 17, 1992.THE REMEDY WAS TO REPLACE THE FUEL PRESSURE REGULATOR AND INSTALL A CHECK VALVE BETWEEN EACH FUEL SUPPLY LINE AND FUEL TANK (2) TO REPAIR THE SUPPLY SIDE FUEL CROSS FLOW PROBLEM (RECALL 93V-125).ODI OPENED RQ98-008 ON MAY 29, 1998 BECAUSE OF THE LARGE NUMBER OF ALLEGED REMEDY FAILURES AND REPORTS OF FUEL CROSS FLOW ON VEHICLES OUTSIDE OF THE RECALL POPULATION.BASED ONTHE INFORMATION RECEIVED FROM FORD ON AUGUST 11, SEPTEMBER 30, AND DECEMBER 15, 1998, AND THE INCREASING TREND OF REMEDY FAILURES AND OUT OF SCOPE CROSSFLOW REPORTS, ODI OPENED EA99-032 ON NOVEMBER 4, 1999.THE ATTACHED ENGINEERING ANALYSIS CLOSING REPORT FULLY DESCRIBES THE RESULTS OF THIS INVESTIGATION AND REASON FOR CLOSING.THE SUBJECT VEHICLES CAN EXPERIENCE FUEL TRANSFER FROM ONE TANK TO THE OTHER DUE TO MALFUNCTIONS IN THE FUEL SYSTEM.WHEN FUEL IS PUMPED OR RETURNED TO THE NON-OPERATING TANK (CROSS FLOW), THE CAPACITY OF THE NON-OPERATING TANK CAN BE EXCEEDED, CAUSING FUEL TO OVERFLOW PAST THE FILLER CAP, CREATING A FIRE POTENTIAL.
Vehicle Speed Control:linkages
ON JULY 14, 1993 FORD FILED A DEFECT INFORMATION REPORT CONCERNING FUEL TANK CROSS FLOW LEAKAGE ON F-SERIES LIGHT TRUCKS AND CAB CHASSIS BUILT FROM JULY 22, 1989 THROUGH DECEMBER 17, 1992.THE REMEDY WAS TO REPLACE THE FUEL PRESSURE REGULATOR AND INSTALL A CHECK VALVE BETWEEN EACH FUEL SUPPLY LINE AND FUEL TANK (2) TO REPAIR THE SUPPLY SIDE FUEL CROSS FLOW PROBLEM (RECALL 93V-125).ODI OPENED RQ98-008 ON MAY 29, 1998 BECAUSE OF THE LARGE NUMBER OF ALLEGED REMEDY FAILURES AND REPORTS OF FUEL CROSS FLOW ON VEHICLES OUTSIDE OF THE RECALL POPULATION.BASED ONTHE INFORMATION RECEIVED FROM FORD ON AUGUST 11, SEPTEMBER 30, AND DECEMBER 15, 1998, AND THE INCREASING TREND OF REMEDY FAILURES AND OUT OF SCOPE CROSSFLOW REPORTS, ODI OPENED EA99-032 ON NOVEMBER 4, 1999.THE ATTACHED ENGINEERING ANALYSIS CLOSING REPORT FULLY DESCRIBES THE RESULTS OF THIS INVESTIGATION AND REASON FOR CLOSING.THE SUBJECT VEHICLES CAN EXPERIENCE FUEL TRANSFER FROM ONE TANK TO THE OTHER DUE TO MALFUNCTIONS IN THE FUEL SYSTEM.WHEN FUEL IS PUMPED OR RETURNED TO THE NON-OPERATING TANK (CROSS FLOW), THE CAPACITY OF THE NON-OPERATING TANK CAN BE EXCEEDED, CAUSING FUEL TO OVERFLOW PAST THE FILLER CAP, CREATING A FIRE POTENTIAL.
RQ98008 · Ford F-SERIES Dual Fuel Tank Leakage
Opened May 29, 1998 · Closed Nov 4, 1999
Status: closed (inferred from source dates) · Fuel System, Gasoline:storage:tank Assembly
THESE VEHICLES CAN EXPERIENCE FUEL TRANSFER FROM ONE TANK TO THE OTHER DUE TO A MALFUNCTIONING FUEL PUMP.FROM THE INFORMATION GATHERED TO DATE, IT APPEARS THAT THERE CAN BE MULTIPLE CAUSES AND/OR A COMBINATION OF CAUSES FOR FUEL CROSS FLOW AND THAT THE RECALL REMEDY MAY BE INADEQUATE.FURTHER INVESTIGATION IS NEEDED.THIS INVESTIGATION IS UPGRADED TO EA99-032.CLICK ON DOCUMENT SEARCH BUTTON FOR ADDITIONAL INFORMATION.
EA93001 · Fuel Expulsion
Opened Jan 7, 1993 · Closed Aug 20, 1993
Status: closed (inferred from source dates) · Vehicle Speed Control:linkages
There is no summary currently available
PE92077 · Fuel Expulsion
Opened Sep 9, 1992 · Closed Jan 7, 1993
Status: closed (inferred from source dates) · Vehicle Speed Control:linkages
There is no summary currently available
EA92029 · Front Seat Back Failure
Opened Aug 27, 1992 · Closed Oct 29, 1993
Status: closed (inferred from source dates) · Seats
There is no summary currently available
EA91044 · Loss Of Brake Effectivenes
Opened Oct 30, 1991 · Closed Oct 30, 1992
Status: closed (inferred from source dates) · Service Brakes, Hydraulic
===
EA91031 · Fuel Expulsion
Opened Jun 26, 1991 · Closed Nov 1, 1991
Status: closed (inferred from source dates) · Vehicle Speed Control:linkages
There is no summary currently available
PE91077 · Loss Of Brake Effectivenes
Opened May 23, 1991 · Closed Oct 31, 1991
Status: closed (inferred from source dates) · Service Brakes, Hydraulic
There is no summary currently available
PE91064 · Transmission Fluid Fires
Opened Apr 9, 1991 · Closed Jul 5, 1991
Status: closed (inferred from source dates) · Power Train
There is no summary currently available
PE91017 · Ford Truck Inconsistent Vehicle Control.
Opened Nov 27, 1990 · Closed Apr 17, 1991
Status: closed (inferred from source dates) · Service Brakes, Hydraulic
SEE CLOSE RESUME
Illustration