AFTER HAVING RECALL 89V1141000 SERVICED, ONE WEEK LATER, PROBLEM CAME BACK WORSE THAN BEFORE. FUEL WAS STILL FLOWING FROM ONE TANK TO THE OTHER. DEALER WAS AWARE OF PROBLEM, BUT COULD NOT SOLVE IT. *AK
1990 Ford F150
Owner reports · Recalls · Investigations
Limited comparison data
There is not enough comparable history to draw a useful model-year comparison.
About this comparison →How this year compares
Owner complaints by model year
Compare all F150 years →Counts vary with age, sales and reporting. They are not failure rates.
What owners reported most
All reported categories
Tap a category to read its complaints. One report may name several components.
When problems were reported
Mileage at the reported incident
Limited mileage data: 25 of 254 reports include usable mileage. There isn’t enough coverage to show a useful chart.
NHTSA’s mileage field refers to the reported incident, not necessarily the filing date. This shows report counts, not the likelihood of a failure.
What to inspect
Issues worth paying extra attention to based on owner reports.
- Fuel System, Gasoline. Review the 129 owner reports in this category and discuss these concerns during a pre-purchase inspection. Read reports →
- Electrical System. Review the 34 owner reports in this category and discuss these concerns during a pre-purchase inspection. Read reports →
- Engine And Engine Cooling. Review the 20 owner reports in this category and discuss these concerns during a pre-purchase inspection. Read reports →
NHTSA owner reports · September 18, 2026 snapshot.
Fuel System, Gasoline complaints
129 reports2 RECALLS HAVE BEEN COMPLETED ON THIS FUEL TRANSFER PROBLEM AND DEALER ANSWER WAS THEY JUST PUT ON PARTS AND DIDN'T EXPECT IT TO FIX PROBLEM!*AK
FRONT GAS TANK PUMPS GAS TO REAR TANK, CAUSING IT TO OVERFLOW.*AK
CONSUMER HAD RECALL 93V125000 REPAIRS DONE IN AUGUST 2001, AND WITHIN IN 2 WEEKS FUEL STARTED LEAKING AGAIN. VEHICLE HAS DUAL TANKS. FIRST TIME FRONT TANK WAS DRAINED TO STOP OVERFLOW. SECOND TIME TAKEN TO SERVICE TECHNICIAN TO PUT ANOTHER FUEL REGULATOR TO CONTROL FUEL FLOW. CONSUMET WAS TAKEN VEHICLE INTO REPAIRS S…
Read full complaint
CONSUMER HAD RECALL 93V125000 REPAIRS DONE IN AUGUST 2001, AND WITHIN IN 2 WEEKS FUEL STARTED LEAKING AGAIN. VEHICLE HAS DUAL TANKS. FIRST TIME FRONT TANK WAS DRAINED TO STOP OVERFLOW. SECOND TIME TAKEN TO SERVICE TECHNICIAN TO PUT ANOTHER FUEL REGULATOR TO CONTROL FUEL FLOW. CONSUMET WAS TAKEN VEHICLE INTO REPAIRS SHOP FOR THID TIME, AND WAS NOT SURE IF THIS COULD BE RECTIFIED. *AK
WHEN FILLING BOTH GAS TANKS, FUEL BY PASSING TO ONE TANK CAUSES AN OVERFLOW CONDITION WHICH RESULTS IN FUEL LEAKAGE. ALSO, THERE IS A VERY STRONG GAS ODOR IN PASSENGER'S COMPARTMENT. DEALER HAS BEEN CONTACTED.*AK
RECEIVED RECALL 93E039000. CONTACTED DEALERSHIP, AND HAD FUEL TANK SWITCH REPAIRED. HOWEVER, REMEDY FAILED. CONTACTED DEALER, AND MECHANIC WANTED TO CHARGE CONSUMER FOR REPLACEMENT OF FUEL PUMPS ON BOTH TANKS.*AK CONSUMER STATES HE HAD ALREADY PAID FOR THE REPLACEMENT OF THE FUEL TANK AND SELECTOR SWITCH, HE FOUND OUT ABOU…
Read full complaint
RECEIVED RECALL 93E039000. CONTACTED DEALERSHIP, AND HAD FUEL TANK SWITCH REPAIRED. HOWEVER, REMEDY FAILED. CONTACTED DEALER, AND MECHANIC WANTED TO CHARGE CONSUMER FOR REPLACEMENT OF FUEL PUMPS ON BOTH TANKS.*AK CONSUMER STATES HE HAD ALREADY PAID FOR THE REPLACEMENT OF THE FUEL TANK AND SELECTOR SWITCH, HE FOUND OUT ABOUT THE RECALL AND TOOK THE VEHICLE TO THE DEALER, THEY REPLACED IT AGAIN AND CHARGED THE MANUFACTURER FOR PARTS EVEN THOUGH CONSUMER HAD ALREADY HAD THEM REPLACED, THE PROBLEM IS STILL OCCURRING AND DEALER STATED CONSUMER NEEDED TO REPLACE BOTH FUEL PUMPS AT 1150 DOLLARS, CONSUMER HAS HAD ALL REPAIRS EXCEPT THE REPLACEMENT OF THE FRONT FUEL TANK MADE BY A NAPA AUTHORIZED DEALER. *SLC
MY 1990 FORD F150 IS DOING THE SAME EXACT THING AS MENTIONED IN THIS NHTSA CAMPAIGN #93V125000 BUT FORD SAIS IT'S NOT ON THEIR RECALL LIST?*AK
A VERY DANGEROUS CONDITION WITH MY FORD F-150 INVOLVING THE FUEL LINE/GAS TANK SURFACED ON 4/27/01 IN MY ATTACHED GARAGE. AFTER THE VEHICLE WAS STOPPED IN THE GARAGE, SIGNIFICANT QUANTITIES OF GASOLINE WERE FOUND TO BE EXITING ONE OF THE TWO FUEL TANK CAPS ON TO THE FLOOR. TOMBALL FORD REPLACED THE COMPONENTS CAUSING THIS S…
Read full complaint
A VERY DANGEROUS CONDITION WITH MY FORD F-150 INVOLVING THE FUEL LINE/GAS TANK SURFACED ON 4/27/01 IN MY ATTACHED GARAGE. AFTER THE VEHICLE WAS STOPPED IN THE GARAGE, SIGNIFICANT QUANTITIES OF GASOLINE WERE FOUND TO BE EXITING ONE OF THE TWO FUEL TANK CAPS ON TO THE FLOOR. TOMBALL FORD REPLACED THE COMPONENTS CAUSING THIS SAFETY HAZARD IN JAN 1996 UNDER FORD RECALL 93S68. IT IS OBVIOUS THE RECALL DID NOT WORK.!! THESE FACTS HAVE BEEN VERIFIED BY CILLIS CAR CARE, 13650 SCHROEDER RD, HOUSTON, TX 77070. ACCORDING TO TOMBALL FORD, THEY SAY THEY ARE NOT OBLIGATED TO ONCE AGAIN REPAIR THE COMPONENTS OF THE FUEL SYSTEM ON THIS VEHICLE. I DEMAND THAT THE D.O.T. ACT ON THIS SITUATION IMMEDIATELY. MY TRUCK SHOULD BE REPAIRED CORRECTLY AT NO COST TO ME. FURTHER, FOR THE SAFETY OF THE PUBLIC, FORD SHOULD BE REQUIRED TO CONDUCT ANOTHER RECALL AND PERFORM RECALL 93S68 PROPERLY!!!!!*AK
VEHICLE T WAS DRIVING ROUGHLY, AND CONSUMER SMELLED GASOLINE HE HAS DUAL TANK. TRUCK WAS FIXED ON RECALL 01-JAN-96 . *AK
FUEL FROM REAR TANK IS TRANFERRING ALL FUEL INTO FRONT TANK UNTIL IT GETS FULL, THEN IT WILL LEAK OUT OF FUEL FILLER, CAUSING FIRE HAZARD.*AK
Official recalls
496V071000 · Electrical System:ignition
Apr 25, 1996
THE IGNITION SWITCH COULD EXPERIENCE AN INTERNAL SHORT CIRCUIT.
Consequence & remedy
Consequence: THIS CONDITION COULD CAUSE OVERHEATING, SMOKE, AND POSSIBLY FIRE IN THE STEERING COLUMN AREA OF THE VEHICLE.
Remedy: DEALERS WILL REPLACE THE IGNITION SWITCH.
93V125000 · Fuel System, Gasoline:storage:tank Assembly
Aug 2, 1993
A MALFUNCTIONING CHECK VALVE WITHIN THE FUEL PUMP ASSEMBLY CAUSES A PORTION OF THE UNUSED FUEL FROM ONE TANK TO BE RETURNED TO THE SECOND TANK. WHEN THIS OCCURS, THE CAPACITY OF THE SECOND TANK CAN BE EXCEEDED, CAUSING FUEL SPILLAGE.
Consequence & remedy
Consequence: SPILLED FUEL CAN RESULT IN A FIRE WHEN EXPOSED TO ASOURCE OF IGNITION.
Remedy: REPLACEMENT OF THE FUEL PRESSURE REGULATOR AND INSTALLATION OF REDUNDANT CHECK VALVES.
90V101000 · Power Train:automatic Transmission:gear Position Indication (prndl)
Jun 1, 1990
UNDER CERTAIN CONDITIONS, THE SNAP RING THAT LOCATES THE PARK GEAR ON THE OUTPUT SHAFT OF THE TRANSMISSION MAY FRACTURE.
Consequence & remedy
Consequence: WHEN THE GEAR IS PLACED IN PARK, THE PARK GEAR WOULD NOTENGAGE, ALLOWING THE TRUCK TO ROLL FREELY IF THE PARKING BRAKE IS NOT PROPERLYSET. THIS COULD RESULT IN AN ACCIDENT.
Remedy: INSTALL IMPROVED SNAP RING AND REVISED TRANSMISSION EXTENSION HOUSING.
89V141000 · Fuel System, Gasoline:storage:auxillary Tank:selector Devices
Aug 15, 1989
INCORRECTLY INSTALLED FUEL LINE CONNECTORS HAVE FUEL SUPPLY AND RETURN LINES CROSSED.
Consequence & remedy
Consequence: FUEL COULD BE TRANSFERRED FROM ONE TANK TO THE OTHER,POSSIBLY RESULTING IN FUEL OVERFLOW AND SPILLAGE, IN PRESENCE OF AN IGNITIONSOURCE, A FIRE COULD OCCUR.
Remedy: REPLACE FUEL LINE ASSEMBLY.
Model-level recall history does not show whether a particular VIN is affected or has received a repair. Check a VIN with NHTSA ↗
NHTSA investigations
10EA99032 · Dual Fuel Tank Crossflow/leakage
Opened Nov 4, 1999 · Closed Dec 6, 2001
Status: closed (inferred from source dates) · Vehicle Speed Control:linkages
ON JULY 14, 1993 FORD FILED A DEFECT INFORMATION REPORT CONCERNING FUEL TANK CROSS FLOW LEAKAGE ON F-SERIES LIGHT TRUCKS AND CAB CHASSIS BUILT FROM JULY 22, 1989 THROUGH DECEMBER 17, 1992.THE REMEDY WAS TO REPLACE THE FUEL PRESSURE REGULATOR AND INSTALL A CHECK VALVE BETWEEN EACH FUEL SUPPLY LINE AND FUEL TANK (2) TO REPAIR THE SUPPLY SIDE FUEL CROSS FLOW PROBLEM (RECALL 93V-125).ODI OPENED RQ98-008 ON MAY 29, 1998 BECAUSE OF THE LARGE NUMBER OF ALLEGED REMEDY FAILURES AND REPORTS OF FUEL CROSS FLOW ON VEHICLES OUTSIDE OF THE RECALL POPULATION.BASED ONTHE INFORMATION RECEIVED FROM FORD ON AUGUST 11, SEPTEMBER 30, AND DECEMBER 15, 1998, AND THE INCREASING TREND OF REMEDY FAILURES AND OUT OF SCOPE CROSSFLOW REPORTS, ODI OPENED EA99-032 ON NOVEMBER 4, 1999.THE ATTACHED ENGINEERING ANALYSIS CLOSING REPORT FULLY DESCRIBES THE RESULTS OF THIS INVESTIGATION AND REASON FOR CLOSING.THE SUBJECT VEHICLES CAN EXPERIENCE FUEL TRANSFER FROM ONE TANK TO THE OTHER DUE TO MALFUNCTIONS IN THE FUEL SYSTEM.WHEN FUEL IS PUMPED OR RETURNED TO THE NON-OPERATING TANK (CROSS FLOW), THE CAPACITY OF THE NON-OPERATING TANK CAN BE EXCEEDED, CAUSING FUEL TO OVERFLOW PAST THE FILLER CAP, CREATING A FIRE POTENTIAL.
Additional source detail variants (2)
Vehicle Speed Control:linkages
ON JULY 14, 1993 FORD FILED A DEFECT INFORMATION REPORT CONCERNING FUEL TANK CROSS FLOW LEAKAGE ON F-SERIES LIGHT TRUCKS AND CAB CHASSIS BUILT FROM JULY 22, 1989 THROUGH DECEMBER 17, 1992.THE REMEDY WAS TO REPLACE THE FUEL PRESSURE REGULATOR AND INSTALL A CHECK VALVE BETWEEN EACH FUEL SUPPLY LINE AND FUEL TANK (2) TO REPAIR THE SUPPLY SIDE FUEL CROSS FLOW PROBLEM (RECALL 93V-125).ODI OPENED RQ98-008 ON MAY 29, 1998 BECAUSE OF THE LARGE NUMBER OF ALLEGED REMEDY FAILURES AND REPORTS OF FUEL CROSS FLOW ON VEHICLES OUTSIDE OF THE RECALL POPULATION.BASED ONTHE INFORMATION RECEIVED FROM FORD ON AUGUST 11, SEPTEMBER 30, AND DECEMBER 15, 1998, AND THE INCREASING TREND OF REMEDY FAILURES AND OUT OF SCOPE CROSSFLOW REPORTS, ODI OPENED EA99-032 ON NOVEMBER 4, 1999.THE ATTACHED ENGINEERING ANALYSIS CLOSING REPORT FULLY DESCRIBES THE RESULTS OF THIS INVESTIGATION AND REASON FOR CLOSING.THE SUBJECT VEHICLES CAN EXPERIENCE FUEL TRANSFER FROM ONE TANK TO THE OTHER DUE TO MALFUNCTIONS IN THE FUEL SYSTEM.WHEN FUEL IS PUMPED OR RETURNED TO THE NON-OPERATING TANK (CROSS FLOW), THE CAPACITY OF THE NON-OPERATING TANK CAN BE EXCEEDED, CAUSING FUEL TO OVERFLOW PAST THE FILLER CAP, CREATING A FIRE POTENTIAL.
Vehicle Speed Control:linkages
ON JULY 14, 1993 FORD FILED A DEFECT INFORMATION REPORT CONCERNING FUEL TANK CROSS FLOW LEAKAGE ON F-SERIES LIGHT TRUCKS AND CAB CHASSIS BUILT FROM JULY 22, 1989 THROUGH DECEMBER 17, 1992.THE REMEDY WAS TO REPLACE THE FUEL PRESSURE REGULATOR AND INSTALL A CHECK VALVE BETWEEN EACH FUEL SUPPLY LINE AND FUEL TANK (2) TO REPAIR THE SUPPLY SIDE FUEL CROSS FLOW PROBLEM (RECALL 93V-125).ODI OPENED RQ98-008 ON MAY 29, 1998 BECAUSE OF THE LARGE NUMBER OF ALLEGED REMEDY FAILURES AND REPORTS OF FUEL CROSS FLOW ON VEHICLES OUTSIDE OF THE RECALL POPULATION.BASED ONTHE INFORMATION RECEIVED FROM FORD ON AUGUST 11, SEPTEMBER 30, AND DECEMBER 15, 1998, AND THE INCREASING TREND OF REMEDY FAILURES AND OUT OF SCOPE CROSSFLOW REPORTS, ODI OPENED EA99-032 ON NOVEMBER 4, 1999.THE ATTACHED ENGINEERING ANALYSIS CLOSING REPORT FULLY DESCRIBES THE RESULTS OF THIS INVESTIGATION AND REASON FOR CLOSING.THE SUBJECT VEHICLES CAN EXPERIENCE FUEL TRANSFER FROM ONE TANK TO THE OTHER DUE TO MALFUNCTIONS IN THE FUEL SYSTEM.WHEN FUEL IS PUMPED OR RETURNED TO THE NON-OPERATING TANK (CROSS FLOW), THE CAPACITY OF THE NON-OPERATING TANK CAN BE EXCEEDED, CAUSING FUEL TO OVERFLOW PAST THE FILLER CAP, CREATING A FIRE POTENTIAL.
RQ98008 · Ford F-SERIES Dual Fuel Tank Leakage
Opened May 29, 1998 · Closed Nov 4, 1999
Status: closed (inferred from source dates) · Fuel System, Gasoline:storage:tank Assembly
THESE VEHICLES CAN EXPERIENCE FUEL TRANSFER FROM ONE TANK TO THE OTHER DUE TO A MALFUNCTIONING FUEL PUMP.FROM THE INFORMATION GATHERED TO DATE, IT APPEARS THAT THERE CAN BE MULTIPLE CAUSES AND/OR A COMBINATION OF CAUSES FOR FUEL CROSS FLOW AND THAT THE RECALL REMEDY MAY BE INADEQUATE.FURTHER INVESTIGATION IS NEEDED.THIS INVESTIGATION IS UPGRADED TO EA99-032.CLICK ON DOCUMENT SEARCH BUTTON FOR ADDITIONAL INFORMATION.
EA93001 · Fuel Expulsion
Opened Jan 7, 1993 · Closed Aug 20, 1993
Status: closed (inferred from source dates) · Vehicle Speed Control:linkages
There is no summary currently available
PE92077 · Fuel Expulsion
Opened Sep 9, 1992 · Closed Jan 7, 1993
Status: closed (inferred from source dates) · Vehicle Speed Control:linkages
There is no summary currently available
EA92029 · Front Seat Back Failure
Opened Aug 27, 1992 · Closed Oct 29, 1993
Status: closed (inferred from source dates) · Seats
There is no summary currently available
EA91044 · Loss Of Brake Effectivenes
Opened Oct 30, 1991 · Closed Oct 30, 1992
Status: closed (inferred from source dates) · Service Brakes, Hydraulic
===
EA91031 · Fuel Expulsion
Opened Jun 26, 1991 · Closed Nov 1, 1991
Status: closed (inferred from source dates) · Vehicle Speed Control:linkages
There is no summary currently available
PE91077 · Loss Of Brake Effectivenes
Opened May 23, 1991 · Closed Oct 31, 1991
Status: closed (inferred from source dates) · Service Brakes, Hydraulic
There is no summary currently available
PE91064 · Transmission Fluid Fires
Opened Apr 9, 1991 · Closed Jul 5, 1991
Status: closed (inferred from source dates) · Power Train
There is no summary currently available
PE91017 · Ford Truck Inconsistent Vehicle Control.
Opened Nov 27, 1990 · Closed Apr 17, 1991
Status: closed (inferred from source dates) · Service Brakes, Hydraulic
SEE CLOSE RESUME
Illustration