← New search

1993 Ford F-250

Owner reports · Recalls · Investigations

Similar to other model years

Owner complaints for the 1993 Ford F-250 do not stand out strongly from the model-year median of 119.

About this comparison →

How this year compares

Owner complaints by model year

Other model years Selected year
Compare all F-250 years →

Counts vary with age, sales and reporting. They are not failure rates.

What owners reported most

All reported categories

Tap a category to read its complaints. One report may name several components.

When problems were reported

Mileage at the reported incident

Limited mileage data: 7 of 130 reports include usable mileage. There isn’t enough coverage to show a useful chart.

NHTSA’s mileage field refers to the reported incident, not necessarily the filing date. This shows report counts, not the likelihood of a failure.

What to inspect

Issues worth paying extra attention to based on owner reports.

  • Fuel System, Gasoline. Review the 36 owner reports in this category and discuss these concerns during a pre-purchase inspection. Read reports →
  • Engine And Engine Cooling. Review the 29 owner reports in this category and discuss these concerns during a pre-purchase inspection. Read reports →
  • Service Brakes, Hydraulic. Review the 24 owner reports in this category and discuss these concerns during a pre-purchase inspection. Read reports →

NHTSA owner reports · September 18, 2026 snapshot.

5 crash reports4 fire reports4 injury reports

What owners actually said

130 reports
Mileage unknown · Apr 27, 2001
Fuel System, GasolineInjury

CONSUMER WAS FUELING TRUCK WITH GAS WHEN IT SUDDENLY SHOT BACK OUT OF TANK AND WENT ALL OVER HIM; ARMS , STOMACH, ETC. REPORTED THIS TO GAS STATION WHERE HE WAS FILLING HIS TANK AT THE TIME. *AK RECALL 93V125, HOWEVER CONSUMER'S VEHICLE IS NOT INCLUDED, CONSUMER WAS INJURED BY THE GASOLINE BURNS. *SLC

NHTSA ODI #887000

Mileage unknown · Mar 26, 2001
Fuel System, Gasoline

CONSUMER IS HAVING PROBLEMS WITH FUEL TANK WHIC IS SIMILAR TO PROBLEMS MENTIONED IN RECALL 00V42400O. *AK ONE OF THE TANK HAD BEEN REPLACED. THE CONSUMER FEELS THE MANUFACTURER SHOULD BE RESPONSIBLE FOR ALL THE REPAIRS. *YH

NHTSA ODI #884089

Mileage unknown · Feb 11, 2001
Fuel System, Gasoline

EXISTING RECALL- FUEL DUMPED INTO REAR TANK CAUSING FUEL SPILL ALSO CREATING EXCESSIVE PRESSURE IN REAR TANK. *AK

NHTSA ODI #740730

Mileage unknown · Jan 18, 2001
Fuel System, Gasoline

DUAL FUEL TANKS. FUEL IS RUNNING FROM FRONT TANK TO REAR WHICH IS CAUSING IT TO OVERFLOW AND LEAK ONTO STREET, RESULTING IN FIRE HAZARD. DEALER REPLACED PUMP ASSEMBLY, AND OTHER RELATED PARTS, BUT DEFECT STILL OCCURS. *AK

NHTSA ODI #878441

Mileage unknown · Jan 11, 2001
Steering

STEERING BELT TENSIONER ASSEMBLY WORE OUT, CAUSING LOSS OF POWER TO BRAKES & STEERING. *AK

NHTSA ODI #739228

Mileage unknown · Dec 20, 2000
Fuel System, Gasoline

A PORTION OF UNUSED FUEL IS BEING SENT TO SECOND TANK, CAUSING FUEL LEAKAGE. A RECALL HAS BEEN ISSUED ON VEHICLE'S MAKE AND MODEL; HOWEVER, THIS VEHICLE WAS NOT INCLUDED DUE TO VIN. *AK *SLC

NHTSA ODI #876809

Mileage unknown · Dec 11, 2000
Fuel System, Gasoline

THERE IS A GAS LEAK WITHIN VEHICLE. AN OPEN INVESTIGATION FOR THIS PROBLEM, BUT CONSUMER'S RECALL WAS NOT PART OF IT. CONSUMER HAD SAME PROBLEM AS RECALL 93V125OO, FUEL TANK ASSEMBLY. *AK

NHTSA ODI #876301

Mileage unknown · Dec 3, 2000
Tires

IN THE WAY OF AN INTRODUCTION, AND TO HELP EXPLAIN THE TECHNICAL DETAIL IN THE FOLLOWING DESCRIPTION, I THINK IT IS WORTHWHILE TO EXPLAIN THAT I AM A RETIRED RESEARCH AND TEST ENGINEER WHO SPENT 22 YEARS OF MY PROFESSIONAL CAREER AS AN ENGINEER WORKING FOR PACCAR INC, THEY MANUFACTURE KENWORTH AND PETERBILT TRUCKS. THE VAST MAJ…

Read full complaint

IN THE WAY OF AN INTRODUCTION, AND TO HELP EXPLAIN THE TECHNICAL DETAIL IN THE FOLLOWING DESCRIPTION, I THINK IT IS WORTHWHILE TO EXPLAIN THAT I AM A RETIRED RESEARCH AND TEST ENGINEER WHO SPENT 22 YEARS OF MY PROFESSIONAL CAREER AS AN ENGINEER WORKING FOR PACCAR INC, THEY MANUFACTURE KENWORTH AND PETERBILT TRUCKS. THE VAST MAJORITY OF MY TIME WITH PACCAR WAS SPENT TESTING AUTOMOTIVE PRODUCTS AT THEIR TRUCK R&D CENTER. ( DOT NUMBER: PJOR D6KV TIRE SIZE: LT235/85R1 )

NHTSA ODI #737244

Mileage unknown · Nov 9, 2000
Vehicle Speed Control

FIRST REPORTED DEFECT, CRUISE CONTROL. WHILE DRIVING ON 2 LANE AT CRUISE SPEED OF 40 MPH, ENTERED REDUCED SPEED ZONE, TAPPED BRAKES TO RELEASE CRUISE CONTROL AND SLOW TO 30 MPH, RELEASED BRAKE WHEN DESIRED SPEED WAS REACHED, VEHICLE SUDDENLY ACCELERATED, 2000 RPM ON TACH., RELEASED CRUISE WITH SWITCH ON STEERING WHEEL, FORD CUST…

Read full complaint

FIRST REPORTED DEFECT, CRUISE CONTROL. WHILE DRIVING ON 2 LANE AT CRUISE SPEED OF 40 MPH, ENTERED REDUCED SPEED ZONE, TAPPED BRAKES TO RELEASE CRUISE CONTROL AND SLOW TO 30 MPH, RELEASED BRAKE WHEN DESIRED SPEED WAS REACHED, VEHICLE SUDDENLY ACCELERATED, 2000 RPM ON TACH., RELEASED CRUISE WITH SWITCH ON STEERING WHEEL, FORD CUSTOMER SERVICE CONTACTED IN DETROIT, MI, STATED NO KNOWN RECALL, MY PROBLEM. SECOND ITEM NOTED, SINCE VEHICLE WAS PURCHASED, NEW, FRONT STEERING ASSEMBLY GREESE/DUST BOOTS HAVE SPLIT, DEALER REPLACED TWICE, ASKED TO DELAY THIRD REPLACEMENT UNTIL FORD COULD WORK OUT PROBLEM, WHEN RETURNED TO DEALER, UNDER NEW OWNERSHIP, TOLD TRUCK OUT OF WARRANTEE, PROBLEM WAS MINE, EVEN THOUGHT FORD FAILED TO EVER REPAIR. *AK

NHTSA ODI #736062

Mileage unknown · Oct 20, 2000
Fuel System, Gasoline

EA93020; FRONT TANK WAS FILLING UP REAR TANK WHICH COULD HAVE CAUSED FUEL TO SPILL OVER. BUT, CONSUMER WAS ABLE TO SWITCH OVER TO THE FRONT TANK BEFORE IT SPILLED. FORD CLAIMED FUEL PUMP IN THE REAR TANK WILL NEED TO BE REPLACED.*AK

NHTSA ODI #873514

Official recalls

6

08V051000 · Vehicle Speed Control:cruise Control

Feb 4, 2008

FORD IS RECALLING 225,000 MY 1992-2003 ECONOLINE, MY 1993-1995 TAURUS SHO, MY 1992-1998 CROWN VICTORIA, MY 1993 BRONCO, F-SERIES, MY 1995-1997 F-SERIES SUPER DUTY STRIPPED CHASSIS, MY 1992-1998 MERCURY GRAND MARQUIS, AND MY 1992-1995 LINCOLN TOWN CAR VEHICLES. THE AFFECTED VEHICLES WERE PREVIOUSLY REPAIRED USING A WIRING HARNESS THAT IS NOT COMPATIBLE WITH THE VEHICLE CIRCUIT POLARITY.

Consequence & remedy

Consequence: AS A RESULT, THE FUSE IS LOCATED IN THE OUTPUT CIRCUIT RATHER THAN IN THE INTENDED INPUT POWER FEED CIRCUIT, AND MAY NOT OFFER THE INTENDED PROTECTION IN THE EVENT OF AN ELECTRICAL SHORT TO GROUND.

Remedy: DEALERS WILL INSTALL A NEW WIRING HARNESS, OR REPLACE THE MATING ELECTRICAL COMPONENT. THE RECALL BEGAN ON FEBRUARY 18, 2008. OWNERS MAY CONTACT FORD AT 1-800-392-3673.

07V336000 · Vehicle Speed Control

Aug 3, 2007

ON CERTAIN PICKUP TRUCKS, PASSENGER VEHICLES, SPORT UTILITY VEHICLES, AND MOTOR HOMES CHASSIS, THE SPEED CONTROL DEACTIVATION SWITCH MAY, UNDER CERTAIN CONDITIONS, LEAK INTERNALLY AND THEN OVERHEAT, SMOKE, OR BURN.

Consequence & remedy

Consequence: THIS COULD RESULT IN AN UNDERHOOD FIRE.

Remedy: DEALERS WILL INSTALL A FUSED WIRING HARNESS. OWNERS OF THE PASSENGER CARS INCLUDED IN THIS CAMPAIGN WILL BE INSTRUCTED TO RETURN THEIR VEHICLES TO THEIR DEALERS TO HAVE THE SPEED CONTROL DEACTIVATION SWITCH DISCONNECTED AS AN INTERIM REPAIR. AS SOON AS REPAIR PARTS ARE AVAILABLE (EXPECTED OCTOBER 2007), OWNERS WILL BE INSTRUCTED TO RETURN TO THE DEALERS FOR INSTALLATION OF A FUSED WIRING HARNESS. THE RECALL BEGAN ON AUGUST 13, 2007, AND MAILING COMPLETED BY SEPTEMBER 19, 2007. OWNERS MAY CONTACT FORD AT 1-888-222-2751.

00V424000 · Fuel System, Gasoline:storage:tank Assembly

Dec 29, 2000

VEHICLE DESCRIPTION: LIGHT DUTY TRUCKS AND CAB CHASSIS EQUIPPED WITH GASOLINE ENGINES AND DUAL FUEL TANKS. THE CARBON STEEL FUEL PRESSURE REGULATOR IN THE FUEL SYSTEM CAN WEAR OUT DURING THE LIFE OF THE VEHICLE. IF THE FUEL PRESSURE REGULATOR MALFUNCTIONS, IT CAN CAUSE HIGH FUEL SYSTEM PRESSURE, WHICH DAMAGES THE FUEL PUMP CHECK VALVE. THIS ALLOWS FUEL TO BE TRANSFERRED FROM ONE TANK TO THE OTHER, POSSIBLY OVERFILLING THE NON-OPERATING TANK, RESULTING IN FUEL OVERFLOW PAST THE FILLER CAP.

Consequence & remedy

Consequence: FUEL LEAKAGE IN THE PRESENCE OF AN IGNITION SOURCE COULD RESULT IN A VEHICLE FIRE.

Remedy: DEALERS WILL HAVE A STAINLESS STEEL FUEL PRESSURE REGULATOR INSTALLED. OWNER NOTIFICATION BEGAN JULY 9, 2001. OWNERS WHO TAKE THEIR VEHICLES TO AN AUTHORIZED DEALER ON AN AGREED UPON SERVICE DATE AND DO NOT RECEIVE THE FREE REMEDY WITHIN A REASONABLE TIME SHOULD CONTACT FORD AT 1-866-436-7332. (SEE PREVIOUS NHTSA RECALL 93V-125/FORD RECALL 93S68).

94V169001 · Parking Brake:conventional

Sep 7, 1994

THE PARKING BRAKE CONTROL SELF-ADJUST PAWL DOES NOT LINE UP PROPERLY WITH THE SELF-ADJUST RACHET CAUSING THE PAWL TO SLIP OVER ONE OR MORE TEETH IN THE RACHET.

Consequence & remedy

Consequence: WHEN THE ABOVE OCCURS, IT CAN RESULT IN PARKING BRAKE SYSTEM INEFFECTIVENESS. THE PARKING BRAKE WILL NOT HOLD THE VEHICLE, CAUSING THE VEHICLE TO ROLL FREELY, IF THE TRANSMISSION IS NOT LEFT IN GEAR.

Remedy: A WEDGE WILL BE INSTALLED WHICH WILL SERVE TO LOCK THE PARKING BRAKE SELF-ADJUST MECHANISM PAWL INTO ENGAGEMENT WITH THE RACHET. ALSO, OWNERS WILL BE ADVISED TO RELEASE AND REAPPLY THE PARKING BRAKE WHENEVER TOOTH SKIP OCCURS AND WILL BE REMINDED TO ALWAYS TURN OFF THE ENGINE AND LEAVE THE VEHICLE IN GEAR WHEN THE VEHICLE IS PARKED.

94V018000 · Structure:body:bumpers

Jan 2, 1994

THE U-CLIP STYLE NUTS THAT RETAIN THE FRONT BUMPERS TO THE FRONT BUMPER INNER ARMS CAN FRACTURE.

Consequence & remedy

Consequence: IF ONE OF THE U-CLIP NUTS FRACTURES, THE BUMPER WILL LOOSEN AND RATTLE CAUSING FRACTURE OF THE REMAINING U-CLIP NUTS, RESULTING IN SEPARATION OF THE BUMPER FROM THE VEHICLE. IF THE BUMPER WERE TO DETACH FROM THE VEHICLE WHILE IT IS BEING DRIVEN, A VEHICLE COLLISION COULD RESULT.

Remedy: INSPECTION AND REPLACEMENT OF THE FOUR U-CLIP NUTS AND THE ASSOCIATED BOLTS.

93V125000 · Fuel System, Gasoline:storage:tank Assembly

Aug 2, 1993

A MALFUNCTIONING CHECK VALVE WITHIN THE FUEL PUMP ASSEMBLY CAUSES A PORTION OF THE UNUSED FUEL FROM ONE TANK TO BE RETURNED TO THE SECOND TANK. WHEN THIS OCCURS, THE CAPACITY OF THE SECOND TANK CAN BE EXCEEDED, CAUSING FUEL SPILLAGE.

Consequence & remedy

Consequence: SPILLED FUEL CAN RESULT IN A FIRE WHEN EXPOSED TO ASOURCE OF IGNITION.

Remedy: REPLACEMENT OF THE FUEL PRESSURE REGULATOR AND INSTALLATION OF REDUNDANT CHECK VALVES.

Model-level recall history does not show whether a particular VIN is affected or has received a repair. Check a VIN with NHTSA ↗

NHTSA investigations

3

EA99032 · Dual Fuel Tank Crossflow/leakage

Opened Nov 4, 1999 · Closed Dec 6, 2001

Status: closed (inferred from source dates) · Vehicle Speed Control:linkages

ON JULY 14, 1993 FORD FILED A DEFECT INFORMATION REPORT CONCERNING FUEL TANK CROSS FLOW LEAKAGE ON F-SERIES LIGHT TRUCKS AND CAB CHASSIS BUILT FROM JULY 22, 1989 THROUGH DECEMBER 17, 1992.THE REMEDY WAS TO REPLACE THE FUEL PRESSURE REGULATOR AND INSTALL A CHECK VALVE BETWEEN EACH FUEL SUPPLY LINE AND FUEL TANK (2) TO REPAIR THE SUPPLY SIDE FUEL CROSS FLOW PROBLEM (RECALL 93V-125).ODI OPENED RQ98-008 ON MAY 29, 1998 BECAUSE OF THE LARGE NUMBER OF ALLEGED REMEDY FAILURES AND REPORTS OF FUEL CROSS FLOW ON VEHICLES OUTSIDE OF THE RECALL POPULATION.BASED ONTHE INFORMATION RECEIVED FROM FORD ON AUGUST 11, SEPTEMBER 30, AND DECEMBER 15, 1998, AND THE INCREASING TREND OF REMEDY FAILURES AND OUT OF SCOPE CROSSFLOW REPORTS, ODI OPENED EA99-032 ON NOVEMBER 4, 1999.THE ATTACHED ENGINEERING ANALYSIS CLOSING REPORT FULLY DESCRIBES THE RESULTS OF THIS INVESTIGATION AND REASON FOR CLOSING.THE SUBJECT VEHICLES CAN EXPERIENCE FUEL TRANSFER FROM ONE TANK TO THE OTHER DUE TO MALFUNCTIONS IN THE FUEL SYSTEM.WHEN FUEL IS PUMPED OR RETURNED TO THE NON-OPERATING TANK (CROSS FLOW), THE CAPACITY OF THE NON-OPERATING TANK CAN BE EXCEEDED, CAUSING FUEL TO OVERFLOW PAST THE FILLER CAP, CREATING A FIRE POTENTIAL.

Additional source detail variants (2)

Vehicle Speed Control:linkages

ON JULY 14, 1993 FORD FILED A DEFECT INFORMATION REPORT CONCERNING FUEL TANK CROSS FLOW LEAKAGE ON F-SERIES LIGHT TRUCKS AND CAB CHASSIS BUILT FROM JULY 22, 1989 THROUGH DECEMBER 17, 1992.THE REMEDY WAS TO REPLACE THE FUEL PRESSURE REGULATOR AND INSTALL A CHECK VALVE BETWEEN EACH FUEL SUPPLY LINE AND FUEL TANK (2) TO REPAIR THE SUPPLY SIDE FUEL CROSS FLOW PROBLEM (RECALL 93V-125).ODI OPENED RQ98-008 ON MAY 29, 1998 BECAUSE OF THE LARGE NUMBER OF ALLEGED REMEDY FAILURES AND REPORTS OF FUEL CROSS FLOW ON VEHICLES OUTSIDE OF THE RECALL POPULATION.BASED ONTHE INFORMATION RECEIVED FROM FORD ON AUGUST 11, SEPTEMBER 30, AND DECEMBER 15, 1998, AND THE INCREASING TREND OF REMEDY FAILURES AND OUT OF SCOPE CROSSFLOW REPORTS, ODI OPENED EA99-032 ON NOVEMBER 4, 1999.THE ATTACHED ENGINEERING ANALYSIS CLOSING REPORT FULLY DESCRIBES THE RESULTS OF THIS INVESTIGATION AND REASON FOR CLOSING.THE SUBJECT VEHICLES CAN EXPERIENCE FUEL TRANSFER FROM ONE TANK TO THE OTHER DUE TO MALFUNCTIONS IN THE FUEL SYSTEM.WHEN FUEL IS PUMPED OR RETURNED TO THE NON-OPERATING TANK (CROSS FLOW), THE CAPACITY OF THE NON-OPERATING TANK CAN BE EXCEEDED, CAUSING FUEL TO OVERFLOW PAST THE FILLER CAP, CREATING A FIRE POTENTIAL.

Vehicle Speed Control:linkages

ON JULY 14, 1993 FORD FILED A DEFECT INFORMATION REPORT CONCERNING FUEL TANK CROSS FLOW LEAKAGE ON F-SERIES LIGHT TRUCKS AND CAB CHASSIS BUILT FROM JULY 22, 1989 THROUGH DECEMBER 17, 1992.THE REMEDY WAS TO REPLACE THE FUEL PRESSURE REGULATOR AND INSTALL A CHECK VALVE BETWEEN EACH FUEL SUPPLY LINE AND FUEL TANK (2) TO REPAIR THE SUPPLY SIDE FUEL CROSS FLOW PROBLEM (RECALL 93V-125).ODI OPENED RQ98-008 ON MAY 29, 1998 BECAUSE OF THE LARGE NUMBER OF ALLEGED REMEDY FAILURES AND REPORTS OF FUEL CROSS FLOW ON VEHICLES OUTSIDE OF THE RECALL POPULATION.BASED ONTHE INFORMATION RECEIVED FROM FORD ON AUGUST 11, SEPTEMBER 30, AND DECEMBER 15, 1998, AND THE INCREASING TREND OF REMEDY FAILURES AND OUT OF SCOPE CROSSFLOW REPORTS, ODI OPENED EA99-032 ON NOVEMBER 4, 1999.THE ATTACHED ENGINEERING ANALYSIS CLOSING REPORT FULLY DESCRIBES THE RESULTS OF THIS INVESTIGATION AND REASON FOR CLOSING.THE SUBJECT VEHICLES CAN EXPERIENCE FUEL TRANSFER FROM ONE TANK TO THE OTHER DUE TO MALFUNCTIONS IN THE FUEL SYSTEM.WHEN FUEL IS PUMPED OR RETURNED TO THE NON-OPERATING TANK (CROSS FLOW), THE CAPACITY OF THE NON-OPERATING TANK CAN BE EXCEEDED, CAUSING FUEL TO OVERFLOW PAST THE FILLER CAP, CREATING A FIRE POTENTIAL.

EA95012 · Failure Of Serpentine Belt

Opened Mar 31, 1995 · Closed May 28, 1996

Status: closed (inferred from source dates) · Power Train

AN ENGINEERING ANALYSIS CLOSING REPORT IS INCLUDED.

Additional source detail variants (2)

Power Train

AN ENGINEERING ANALYSIS CLOSING REPORT IS INCLUDED.

Power Train

AN ENGINEERING ANALYSIS CLOSING REPORT IS INCLUDED.

EA93020 · Parking Brake Failure

Opened Jul 28, 1993 · Closed Sep 23, 1994

Status: closed (inferred from source dates) · Service Brakes, Hydraulic

There is no summary currently available

Additional source detail variants (2)

Service Brakes, Hydraulic

There is no summary currently available

Service Brakes, Hydraulic

There is no summary currently available