TL* THE CONTACT OWNS A 2006 FORD F-150. THE CONTACT STATED THAT THE VEHICLE WAS TAKEN TO AN INDEPENDENT MECHANIC FOR ROUTINE MAINTENANCE. WHILE AT THE INDEPENDENT MECHANIC, THE CONTACT WAS NOTIFIED THAT SEVEN OF THE EIGHT SPARK PLUGS IN THE VEHICLE WERE FRACTURED AND NEEDED TO BE REPLACED. THE CONTACT STATED THAT ONE OF THE FRAC…
Read full complaint
TL* THE CONTACT OWNS A 2006 FORD F-150. THE CONTACT STATED THAT THE VEHICLE WAS TAKEN TO AN INDEPENDENT MECHANIC FOR ROUTINE MAINTENANCE. WHILE AT THE INDEPENDENT MECHANIC, THE CONTACT WAS NOTIFIED THAT SEVEN OF THE EIGHT SPARK PLUGS IN THE VEHICLE WERE FRACTURED AND NEEDED TO BE REPLACED. THE CONTACT STATED THAT ONE OF THE FRACTURED SPARK PLUGS REMAINED IN THE CYLINDER HEAD. THE MECHANIC STATED THAT THE CYLINDER HEAD HAD TO BE REMOVED FROM THE ENGINE TO REMOVE THE FRACTURED SPARK PLUG. THE VEHICLE WAS NOT REPAIRED. THE MANUFACTURER WAS NOTIFIED OF THE FAILURE; HOWEVER, THE CONTACT WAS NOT OFFERED A REMEDY FOR THE FAILURE. THE FAILURE MILEAGE WAS 84,000.
NHTSA ODI #10733630
83,000 miles · Mar 11, 2015
EngineFuel/propulsion SystemService Brakes
2006 F-150 LOST ALL POWER FUNCTION WHILE TRAVELING DOWN THE INTERSTATE. I LOST POWER STEERING AND BRAKES. THE CAUSE IS A CORROSIVE FUEL PUMP CONTROL MODULE. AFTER TAKING WITH MY LOCAL FORD DEALER I WAS MADE AWARE THAT THIS IS MAJOR SAFETY ISSUE AND ONE THAT FMC REFUSES TO RECOGNIZE. THIS INCIDENT COULD HAVE RESULTED IN A MAJOR A…
Read full complaint
2006 F-150 LOST ALL POWER FUNCTION WHILE TRAVELING DOWN THE INTERSTATE. I LOST POWER STEERING AND BRAKES. THE CAUSE IS A CORROSIVE FUEL PUMP CONTROL MODULE. AFTER TAKING WITH MY LOCAL FORD DEALER I WAS MADE AWARE THAT THIS IS MAJOR SAFETY ISSUE AND ONE THAT FMC REFUSES TO RECOGNIZE. THIS INCIDENT COULD HAVE RESULTED IN A MAJOR ACCIDENT. I WAS LUCKY ENOUGH TO BE ABLE TO SIGNAL TO THE CARS AROUND ME THAT I WAS HAVING TROUBLE - HOWEVER I WAS STILL ALMOST REAR ENDED TWICE BEFORE BEING ABLE TO PULL OFF TO THE SIDE OF THE ROAD. *TR
NHTSA ODI #10693652
95,000 miles · Dec 28, 2014
Engine
THE ENGINE BEGAN TO TICK ON TOP. LATER IT BEGAN TO TICK ON THE BOTTOM. THE ENGINE LIGHT CAME ON AND I HAD IT CHECKED. THE CODE SAID IT WAS A CAM SENSOR. AS IT TURNED OUT THE ENGINE WAS NOT GETTING THE PROPER AMOUNT OF OIL DUE TO A CLOGGED A OIL PORT RESTRICTION. END RESULT HAD TO REPLACE THE ENGINE. WHILE AT THE SERVICE C…
Read full complaint
THE ENGINE BEGAN TO TICK ON TOP. LATER IT BEGAN TO TICK ON THE BOTTOM. THE ENGINE LIGHT CAME ON AND I HAD IT CHECKED. THE CODE SAID IT WAS A CAM SENSOR. AS IT TURNED OUT THE ENGINE WAS NOT GETTING THE PROPER AMOUNT OF OIL DUE TO A CLOGGED A OIL PORT RESTRICTION. END RESULT HAD TO REPLACE THE ENGINE. WHILE AT THE SERVICE CENTER ANOTHER TRUCK CAME IN WITH THE SAME PROBLEM WITH SIMILAR MILEAGE. NOW MY SON WHO HAS A 2005 FORD F150 IS EXPERIENCING THE SAME ISSUES WITH HIS TRUCK WITH 96000 MILES THAT'S THREE THAT I KNOW OF. *TR
NHTSA ODI #10668537
90,000 miles · Nov 10, 2014
Engine
WHILE DRIVING THE FORD 2006 F150 IT JUST STARTED RUNNING SLUGGISH AND STOPPED. I WAS ABLE TO GET OFF THE SIDE OF THE ROAD. *TR
NHTSA ODI #10653874
Mileage unknown · Sep 22, 2014
Engine
ENGINE HAD BLOWN A PLUG OUT ABOUT 300 MILES AGO ON THE NUMBER 3 WAS REPAIRED WITH REPAIR KIT NEW PLUG AND COIL WAS PUT ON. WAS TRAVELING STARTED UP HILL ENGINE BEGAN TO MISS DROVE 20 MILES TO DESTINATION HAD TRUCK TESTED AT ADVANCE AUTO PARTS READOUT STATED MISFIRE ON CYLINDER 1 AND 3 AND BAD COIL ON 3. REPLACED COIL 3 AGAIN TOO…
Read full complaint
ENGINE HAD BLOWN A PLUG OUT ABOUT 300 MILES AGO ON THE NUMBER 3 WAS REPAIRED WITH REPAIR KIT NEW PLUG AND COIL WAS PUT ON. WAS TRAVELING STARTED UP HILL ENGINE BEGAN TO MISS DROVE 20 MILES TO DESTINATION HAD TRUCK TESTED AT ADVANCE AUTO PARTS READOUT STATED MISFIRE ON CYLINDER 1 AND 3 AND BAD COIL ON 3. REPLACED COIL 3 AGAIN TOOK TO MECHANIC HIS COMPUTER READ OUT WAS NUMBER 8 COIL WAS BAD REPLACED IT ENGINE CONTINUED TO MISS TOOK IT TO THE MECHANIC HE CHANGED ALL THE PLUGS THE 2ND PLUG ON DRIVERS SIDE WAS LOOSE AND READY TO BLOW OUT AND HE TOOK THE NUMBER 3 PLUG OUT THAT HAD BEEN REPLACED PRIOR THE WHOLE BOTTOM OF PLUG WAS MELTED COULD HAVE RESULTED IN A FIRE LOOKED DOWN IN ENGINE WITH CAMERA THE PISTON WAS DESTROYED. THIS PROBLEM IS FROM THE FACTORY INSTALLED PLUG BLOWING OUT AND FRAGMENTS GOING INTO ENGINE. NOW I HAVE TO REPLACE MY ENGINE 2500 OUT OF MY POCKET D/T POOR HEAD DESIGN FORD IS WELL AWARE OF THIS PROBLEM AND REFUSES ANY ASSISTANCE FORD ACTUALLY HAS EXCLUDED BLOWN PLUG REPAIR FROM THEIR WARRANTY. WHEN YOU PURCHASE A NEW VEHICLE YOU EXPECT TO GET MORE THAN 106000 MILES. *TR
NHTSA ODI #10637941
78,000 miles · Sep 17, 2014
Engine
VEHICLE STARTED MISSING AND BUCKING. BROUGHT INTO MECHANIC AND WAS TOLD THIS IS A VERY COMMON PROBLEM WITH TRITON 5.4L ENGINE. NEEDS SPARK PLUG CHANGE AND CHANCES ARE THEY WILL BREAK OFF IN ENGINE WHILE CHANGING (WHICH 5 OUT OF 8 DID). TOTAL COST A SHAMEFUL $800 (ESTIMATE WAS BETWEEN $600-$1200). MECHANIC PULLED OUT MANY PRI…
Read full complaint
VEHICLE STARTED MISSING AND BUCKING. BROUGHT INTO MECHANIC AND WAS TOLD THIS IS A VERY COMMON PROBLEM WITH TRITON 5.4L ENGINE. NEEDS SPARK PLUG CHANGE AND CHANCES ARE THEY WILL BREAK OFF IN ENGINE WHILE CHANGING (WHICH 5 OUT OF 8 DID). TOTAL COST A SHAMEFUL $800 (ESTIMATE WAS BETWEEN $600-$1200). MECHANIC PULLED OUT MANY PRIOR INVOICES FROM OWNERS WITH THE EXACT SAME ISSUE. THE SPARK PLUGS IN THESE ENGINES SHOULD BE RECALLED. *TR
NHTSA ODI #10637048
3,200 miles · Sep 1, 2014
Electrical SystemEngineUnknown Or Other
WENT TO STOP FOR TRAFFIC LIGHT APPLIED THE BRAKES AND VEHICLE TOOK OFF///////SLAMMED ON BRAKES TO TRY TO STOP AND SLAMMED IN PARK .CAME WITH IN INCHES OF CRASHING INTO CAR IN FRONT OF ME. TODAY IS SEPT.1ST HAVE NOT DRIVEN TRUCK AGAIN////// CALL FORD CORP. THEY WILL NOT PAY TO CHECK OUT TRUCK. AT 3100 MILES HAD TO REPLACE TIRES. …
Read full complaint
WENT TO STOP FOR TRAFFIC LIGHT APPLIED THE BRAKES AND VEHICLE TOOK OFF///////SLAMMED ON BRAKES TO TRY TO STOP AND SLAMMED IN PARK .CAME WITH IN INCHES OF CRASHING INTO CAR IN FRONT OF ME. TODAY IS SEPT.1ST HAVE NOT DRIVEN TRUCK AGAIN////// CALL FORD CORP. THEY WILL NOT PAY TO CHECK OUT TRUCK. AT 3100 MILES HAD TO REPLACE TIRES. ORIG. HAD DRY ROT,,,,,, *TR
NHTSA ODI #10629943
104,000 miles · Aug 17, 2014
Engine
ENGINE STARTED MAKING A LOUD NOISE UPON INSPECTION OF ENGINE FOUND THAT THE BACK SPARK PLUG ON PASSENGER SIDE HAD BLOWN OUT FROM HEAD AND OF COURSE STRIPPED THE TREADS FROM THE HEAD THE SPARK PLUGS ARE THE ONES THAT CAME FROM FACTORY THEY HAVE NEVER BEEN REMOVED OR REPLACED VEHICLE WAS PURCHASED NEW AFTER REVIEWING INFORMATION O…
Read full complaint
ENGINE STARTED MAKING A LOUD NOISE UPON INSPECTION OF ENGINE FOUND THAT THE BACK SPARK PLUG ON PASSENGER SIDE HAD BLOWN OUT FROM HEAD AND OF COURSE STRIPPED THE TREADS FROM THE HEAD THE SPARK PLUGS ARE THE ONES THAT CAME FROM FACTORY THEY HAVE NEVER BEEN REMOVED OR REPLACED VEHICLE WAS PURCHASED NEW AFTER REVIEWING INFORMATION ON THE INTERNET THIS SEEMS TO BE A MAJOR PROBLEM WITH FORDS 4.6 AND 5.4 ENGINE AS WELL AS RESULTING IN FIRES AND CONSIDERING FORD MAKES A REPAIR KIT. IF THIS HAS EFFECTED THIS MANY VEHICLE SHOULDN'T FORD FOOT THE BILL. *TR
NHTSA ODI #10625815
50,000 miles · Aug 4, 2014
Engine
TL* THE CONTACT OWNS A 2006 FORD F-150. THE CONTACT STATED THAT WHILE DRIVING UPHILL, THERE WAS A ENGINE MISFIRE. THE VEHICLE WAS TAKEN TO A DEALER WHERE THE VEHICLE WAS REPAIRED. THE FAILURE RECURRED. THE MANUFACTURER WAS NOT MADE AWARE OF THE FAILURE. THE FAILURE MILEAGE WAS 50,000.
NHTSA ODI #10618695
62,000 miles · Jul 5, 2014
Engine
FORD HAS AN ONGOING PROBLEM WITH THE 2006-2008 F150. THEY HAVE FAULTY SPARKPLUG THAT WHEN THEY NEED CHANGEDIRECTIONS SNAP. THIS RESULTS IN THEM HAVING TO RETAP THE MOTOR AND PUT DIFFERENT SPARK PLUGS IN WHICH THEY CHARGE $400/SPARK PLUG THAT SNAPS. THE PART THAT SNAPS FALLS INTO THE MOTOR THAT'S WHICH IT IS SO EXPENSIVE. FORD …
Read full complaint
FORD HAS AN ONGOING PROBLEM WITH THE 2006-2008 F150. THEY HAVE FAULTY SPARKPLUG THAT WHEN THEY NEED CHANGEDIRECTIONS SNAP. THIS RESULTS IN THEM HAVING TO RETAP THE MOTOR AND PUT DIFFERENT SPARK PLUGS IN WHICH THEY CHARGE $400/SPARK PLUG THAT SNAPS. THE PART THAT SNAPS FALLS INTO THE MOTOR THAT'S WHICH IT IS SO EXPENSIVE. FORD HAS KNOWN ABOUT THE PROBLEM FOR YEARS BECAUSE THEY MADE SURE TO GET NEW SPARK PLUGS AS SOON AS THERE WERE ISSUES. NUMEROUS PEOPLE INCLUDING MYSELF HAVE CALLED FORD AND COMPLAINED BUT THEY NEVER DO ANYTHING ABOUT IT. I HOPE THAT YOU WILL. *TR
FORD IS RECALLING CERTAIN MODEL YEAR 2004-2006 F-150 PICK UP TRUCKS AS WELL AS CERTAIN MODEL YEAR 2006 LINCOLN MARK LT VEHICLES. IF THE CLOCKSPRING JUMPER WIRE COMES IN CONTACT WITH THE DRIVER SIDE FRONTAL AIR BAG LOWER HORN PLATE, THE WIRE INSULATION MAY BECOME CHAFED, CREATING A POTENTIAL FOR A SHORT CIRCUIT. IF THIS OCCURS THE AIR BAG WARNING LAMP MAY ILLUMINATE INDICATING THAT SERVICE IS REQUIRED.
Consequence & remedy
Consequence: THE DRIVER SIDE FRONTAL AIR BAG COULD INADVERTENTLY DEPLOY INCREASING THE RISK OF INJURY OR LOSS OF VEHICLE CONTROL IF OCCURRING WHILE IN MOTION.
Remedy: FORD WILL NOTIFY OWNERS AND INSTRUCT THEM TO TAKE THEIR VEHICLES TO A FORD OR LINCOLN/MERCURY DEALER TO HAVE A NEW CLOCKSPRING JUMPER WIRE INSTALLED THAT INCORPORATES A PROTECTIVE MESH COVER. REPAIRS WILL BE PERFORMED FREE OF CHARGE. THIS SAFETY RECALL BEGAN ON SOME VEHICLES IN MARCH 2011. THE RECALL CAMPAIGN ON THE EXPANDED POPULATION IS EXPECTED TO BEGIN ON OR ABOUT MAY 9, 2011. OWNERS MAY CONTACT THE FORD MOTOR COMPANY CUSTOMER RELATIONSHIP CENTER AT 1-866-436-7332.
FORD IS RECALLING 605,684 MY 2005-2006 F-150 AND LINCOLN MARK LT VEHICLES EQUIPPED WITH 5.4L 3-VALVE ENGINES. THE BRAKE BOOSTER VACUUM SUPPLY HOSE ATTACHED TO THE INTAKE MANIFOLD FITTING MAY SWELL OVER TIME AND LOSE RETENTION FORCE. THIS CONDITION COULD ALLOW THE HOSE TO BECOME DETACHED FROM THE FITTING DURING AN INTAKE MANIFOLD BACKFIRE. SHOULD THE HOSE DETACH FROM THE INTAKE MANIFOLD, SEVERAL BRAKE APPLICATIONS WITH POWER ASSIST WILL BE AVAILABLE BEFORE THE VACUUM RESERVE IS DEPLETED.
Consequence & remedy
Consequence: ONCE THE BRAKE BOOSTER VACUUM RESERVE IS DEPLETED, THE DRIVER WILL HAVE FOUNDATION BRAKE FUNCTION, BUT WITH INCREASED BRAKE PEDAL EFFORT. REDUCED VEHICLE BRAKING COULD LEAD TO A CRASH.
Remedy: DEALERS WILL REPLACE A RUBBER HOSE ON THE BRAKE BOOSTER VACUUM SUPPLY TUBE ASSEMBLY. THE RECALL BEGAN ON JUNE 27, 2008. OWNERS MAY CONTACT FORD AT 1-800-392-3673.
CERTAIN PICKUP TRUCKS FAIL TO COMPLY WITH EITHER THE REQUIREMENTS OF FEDERAL MOTOR VEHICLE SAFETY STANDARD (FMVSS) NO. 105, 'HYDRAULIC AND ELECTRIC BRAKE SYSTEMS' OR FMVSS NO. 135, 'PASSENGER CAR BRAKE SYSTEMS.' THESE VEHICLES WERE BUILT WITH A SOFTWARE ERROR IN THE INSTRUMENT CLUSTER.
Consequence & remedy
Consequence: THIS ERROR COULD PREVENT THE ANTILOCK BRAKE SYSTEM (ABS) WARNING LIGHT FROM ILLUMINATING IF THE ABS MODULE EVER BECAME INOPERATIVE.
Remedy: DEALERS WILL RECALIBRATE THE INSTRUMENT CLUSTER IN THESE VEHICLES. THE RECALL BEGAN ON FEBRUARY 27, 2006. OWNERS MAY CONTACT FORD AT 1-800-392-3673.
ON CERTAIN TRUCKS, PASSENGER CARS AND SPORT UTILITY VEHICLES, THE WINDSHIELD WIPER MOTOR MAY HAVE BEEN PRODUCED WITHOUT GREASE BEING APPLIED TO THE OUTPUT SHAFT GEAR.
Consequence & remedy
Consequence: AFTER A PERIOD OF CONTINUOUS USE ON THE HIGH SPEED SETTING, LACK OF GREASE ON THE OUTPUT SHAFT GEAR MAY CAUSE THE GEAR TO DISTORT OR FRACTURE DURING OPERATION RESULTING IN A LOSS OF WIPER FUNCTION. INOPERATIVE WIPERS UNDER INCLEMENT WEATHER CONDITIONS COULD CAUSE A CRASH DUE TO IMPAIRED VISIBILITY.
Remedy: DEALERS WILL INSPECT THE WIPER MOTOR FOR THE PRESENCE OF GREASE AND GREASE THE WIPER MOTOR GEARS IF NECESSARY. THE RECALL BEGAN ON NOVEMBER 22, 2005. OWNERS MAY CONTACT FORD AT 1-800-392-3673 OR LINCOLN/MERCURY AT 1-800-521-4140.
Model-level recall history does not show whether a particular VIN is affected or has received a repair. Check a VIN with NHTSA ↗
NHTSA investigations
2
EA10001 · Inadvertent Airbag Deployment
Opened Jan 13, 2010 · Closed Apr 25, 2011
Status: closed (inferred from source dates) · Air Bags; Air Bags:frontal; Air Bags:frontal:driver Side:inflator Module; Air Bags:frontal:sensor/control MODULE-INACTIVE
ODI opened this investigation based on reports of inadvertent airbag deployment.Data provided by Ford indicated that the airbag clockspring jumper wire, which is situated inside the steering wheel assembly, was installed in a manner that would allow it to rub (abrade) against a sharp metal edge on the nearby horn plate.Because the horn plate is electrically grounded the abrasion of an airbag wire on the sharp edge could cause a short circuit condition.As a result the airbag light may illuminate and/or the airbag may inadvertently deploy.Inadvertent deployments are most likely to occur during the airbag system's self-diagnostic test that initiates when the ignition switch is turned on.Ford modified the vehicle design in late January 2006 adding a protective tape over the sharp metal edge of the horn plate.Ford made additional design changes on MY 2007 vehicles to the horn plate, the clockspring jumper, and the connector layouts to further address this issue.ODI identified 318 deployment incidents with 121 alleged injury reports from subject vehicles.All but one of the incident and injury reports occurred in vehicles built before the January 2006 modification.In addition, there was one incident and alleged injury reported in the MY 2006 Mark LT vehicles that share the same design. In letters dated February 21 and April 11, 2011, Ford announced a recall of all of the approximately 1.3 million MY 2004-2006 F-150 vehicles built prior to January 24, 2006, the date the initial vehicle modification was made.In addition, approximately 14,000 MY 2006 Mark LT vehicles built prior to January 24, 2006 will also be recalled.Vehicles built after that date, which contain the modification, are not within the recall scope.Accordingly the investigation is closed.
Additional source detail variants (4)
Air Bags
ODI opened this investigation based on reports of inadvertent airbag deployment.Data provided by Ford indicated that the airbag clockspring jumper wire, which is situated inside the steering wheel assembly, was installed in a manner that would allow it to rub (abrade) against a sharp metal edge on the nearby horn plate.Because the horn plate is electrically grounded the abrasion of an airbag wire on the sharp edge could cause a short circuit condition.As a result the airbag light may illuminate and/or the airbag may inadvertently deploy.Inadvertent deployments are most likely to occur during the airbag system's self-diagnostic test that initiates when the ignition switch is turned on.Ford modified the vehicle design in late January 2006 adding a protective tape over the sharp metal edge of the horn plate.Ford made additional design changes on MY 2007 vehicles to the horn plate, the clockspring jumper, and the connector layouts to further address this issue.ODI identified 318 deployment incidents with 121 alleged injury reports from subject vehicles.All but one of the incident and injury reports occurred in vehicles built before the January 2006 modification.In addition, there was one incident and alleged injury reported in the MY 2006 Mark LT vehicles that share the same design. In letters dated February 21 and April 11, 2011, Ford announced a recall of all of the approximately 1.3 million MY 2004-2006 F-150 vehicles built prior to January 24, 2006, the date the initial vehicle modification was made.In addition, approximately 14,000 MY 2006 Mark LT vehicles built prior to January 24, 2006 will also be recalled.Vehicles built after that date, which contain the modification, are not within the recall scope.Accordingly the investigation is closed.
Air Bags:frontal:driver Side:inflator Module
ODI opened this investigation based on reports of inadvertent airbag deployment.Data provided by Ford indicated that the airbag clockspring jumper wire, which is situated inside the steering wheel assembly, was installed in a manner that would allow it to rub (abrade) against a sharp metal edge on the nearby horn plate.Because the horn plate is electrically grounded the abrasion of an airbag wire on the sharp edge could cause a short circuit condition.As a result the airbag light may illuminate and/or the airbag may inadvertently deploy.Inadvertent deployments are most likely to occur during the airbag system's self-diagnostic test that initiates when the ignition switch is turned on.Ford modified the vehicle design in late January 2006 adding a protective tape over the sharp metal edge of the horn plate.Ford made additional design changes on MY 2007 vehicles to the horn plate, the clockspring jumper, and the connector layouts to further address this issue.ODI identified 318 deployment incidents with 121 alleged injury reports from subject vehicles.All but one of the incident and injury reports occurred in vehicles built before the January 2006 modification.In addition, there was one incident and alleged injury reported in the MY 2006 Mark LT vehicles that share the same design. In letters dated February 21 and April 11, 2011, Ford announced a recall of all of the approximately 1.3 million MY 2004-2006 F-150 vehicles built prior to January 24, 2006, the date the initial vehicle modification was made.In addition, approximately 14,000 MY 2006 Mark LT vehicles built prior to January 24, 2006 will also be recalled.Vehicles built after that date, which contain the modification, are not within the recall scope.Accordingly the investigation is closed.
Air Bags:frontal
ODI opened this investigation based on reports of inadvertent airbag deployment.Data provided by Ford indicated that the airbag clockspring jumper wire, which is situated inside the steering wheel assembly, was installed in a manner that would allow it to rub (abrade) against a sharp metal edge on the nearby horn plate.Because the horn plate is electrically grounded the abrasion of an airbag wire on the sharp edge could cause a short circuit condition.As a result the airbag light may illuminate and/or the airbag may inadvertently deploy.Inadvertent deployments are most likely to occur during the airbag system's self-diagnostic test that initiates when the ignition switch is turned on.Ford modified the vehicle design in late January 2006 adding a protective tape over the sharp metal edge of the horn plate.Ford made additional design changes on MY 2007 vehicles to the horn plate, the clockspring jumper, and the connector layouts to further address this issue.ODI identified 318 deployment incidents with 121 alleged injury reports from subject vehicles.All but one of the incident and injury reports occurred in vehicles built before the January 2006 modification.In addition, there was one incident and alleged injury reported in the MY 2006 Mark LT vehicles that share the same design. In letters dated February 21 and April 11, 2011, Ford announced a recall of all of the approximately 1.3 million MY 2004-2006 F-150 vehicles built prior to January 24, 2006, the date the initial vehicle modification was made.In addition, approximately 14,000 MY 2006 Mark LT vehicles built prior to January 24, 2006 will also be recalled.Vehicles built after that date, which contain the modification, are not within the recall scope.Accordingly the investigation is closed.
Air Bags:frontal:sensor/control MODULE-INACTIVE
ODI opened this investigation based on reports of inadvertent airbag deployment.Data provided by Ford indicated that the airbag clockspring jumper wire, which is situated inside the steering wheel assembly, was installed in a manner that would allow it to rub (abrade) against a sharp metal edge on the nearby horn plate.Because the horn plate is electrically grounded the abrasion of an airbag wire on the sharp edge could cause a short circuit condition.As a result the airbag light may illuminate and/or the airbag may inadvertently deploy.Inadvertent deployments are most likely to occur during the airbag system's self-diagnostic test that initiates when the ignition switch is turned on.Ford modified the vehicle design in late January 2006 adding a protective tape over the sharp metal edge of the horn plate.Ford made additional design changes on MY 2007 vehicles to the horn plate, the clockspring jumper, and the connector layouts to further address this issue.ODI identified 318 deployment incidents with 121 alleged injury reports from subject vehicles.All but one of the incident and injury reports occurred in vehicles built before the January 2006 modification.In addition, there was one incident and alleged injury reported in the MY 2006 Mark LT vehicles that share the same design. In letters dated February 21 and April 11, 2011, Ford announced a recall of all of the approximately 1.3 million MY 2004-2006 F-150 vehicles built prior to January 24, 2006, the date the initial vehicle modification was made.In addition, approximately 14,000 MY 2006 Mark LT vehicles built prior to January 24, 2006 will also be recalled.Vehicles built after that date, which contain the modification, are not within the recall scope.Accordingly the investigation is closed.
PE08001 · Loss Of Brake POWER-ASSIST
Opened Jan 8, 2008 · Closed May 9, 2008
Status: closed (inferred from source dates) · Service Brakes, Hydraulic:power Assist; Service Brakes, Hydraulic:power Assist:vacuum; Service Brakes, Hydraulic:power Assist:vacuum:hoses, Lines/piping, And Fittings
BY LETTER DATED MAY 5, 2008, FORD MOTOR COMPANY (FORD) NOTIFIED THE AGENCY THAT IT WILL CONDUCT A SAFETY RECALL (NHTSA RECALL NUMBER 08V-208) TO ADDRESS A MANUFACTURING DEFECT IN APPROXIMATELY 605,684 MODEL YEAR (MY) 2005 AND 2006 FORD F-150 AND LINCOLN MARK LT VEHICLES ORIGINALLY EQUIPPED WITH THE 5.4L DISPLACEMENT, 3-VALVE PER CYLINDER, V-8 ENGINE.THE RECALLED VEHICLES WERE BUILT FROM JULY 18, 2004 THROUGH MAY 31, 2006 AT THE DEARBORN TRUCK PLANT; FROM MAY 4, 2004 THROUGH MAY 31, 2006 AT THE KANSAS CITY ASSEMBLY PLANT; AND FROM APRIL 19, 2004 THROUGH MAY 31, 2006 AT THE NORFOLK TRUCK PLANT.THE VEHICLES WERE MANUFACTURED WITH THE SAME DEFECTIVE BRAKE BOOSTER VACUUM SUPPLY HOSE ASSEMBLY UNIQUE TO THE 5.4L V-8 ENGINE.FORD F-150 VEHICLES EQUIPPED WITH OPTIONALLY AVAILABLE 4.2L V6 AND 4.6L V-8 ENGINES ARE NOT INCLUDED IN THIS RECALL ACTION BECAUSE THEY UTILIZE A DIFFERENT, ONE-PIECE BRAKE BOOSTER VACUUM SUPPLY HOSE ASSEMBLY THAT DOES NOT EXHIBIT AN APPARENT DEFECT TREND. THE RECALLED VEHICLES UTILIZE A TWO-PIECE BRAKE BOOSTER VACUUM SUPPLY HOSE ASSEMBLY COMPRISED OF A STANDPIPE ASSEMBLY AND VACUUM HOSE.THE STANDPIPE ASSEMBLY ATTACHES TO A FITTING ON THE ENGINE AIR INTAKE MANIFOLD UTILIZING A FLEXIBLE RUBBER HOSE AND PLASTIC ELBOW.THE VACUUM HOSE ATTACHES TO THE OPPOSITE END OF THE STANDPIPE ASSEMBLY AND CONNECTS TO A CHECK VALVE FITTING AT THE BRAKE BOOSTER ASSEMBLY.ACCORDING TO FORD, THE PORTION OF THE BRAKE BOOSTER VACUUM SUPPLY HOSE ASSEMBLY ATTACHED TO THE INTAKE MANIFOLD MAY SWELL OVER TIME AND LOSE RETENTION FORCE, WHICH MAY ALLOW THE HOSE TO BECOME DETACHED FROM THE INTAKE MANIFOLD.SHOULD THE BRAKE BOOSTER VACUUM SUPPLY HOSE ASSEMBLY BE DISRUPTED, APPLICATION OF THE BRAKE PEDAL MAY DEPLETE THE VACUUM RESERVE AND CONSEQUENTLY RESULT IN LOSS OF BRAKE POWER-ASSIST. TO CORRECT THE SAFETY DEFECT, FORD WILL INSTALL AN IMPROVED DESIGN BRAKE BOOSTER VACUUM SUPPLY HOSE ASSEMBLY THAT UTILIZES A HOSE CLAMP AT THE INTAKE MANIFOLD ATTACHMENT. THIS REMEDY WILL BE PROVIDED FREE OF CHARGE FOR ALL RECALLED VEHICLES.LATER PRODUCTION FORD F-150 AND LINCOLN MARK LT VEHICLES BUILT AFTER MAY 2006 WERE MANUFACTURED WITH A HOSE CLAMP AT THE BRAKE BOOSTER VACUUM SUPPLY HOSE/INTAKE MANIFOLD ATTACHMENT AND ARE NOT AFFECTED. TO DATE, THE OFFICE OF DEFECTS INVESTIGATION (ODI) IS AWARE OF 324 NON-DUPLICATIVE COMPLAINTS AND 14 NON-INJURY CRASHES RELATED TO THE ALLEGED DEFECT IN THE SUBJECT VEHICLES.IN ADDITION, ODI IS AWARE OF 4,465 SUBJECT VEHICLES THAT EXPERIENCED ONE OR MORE WARRANTY CLAIMS TO REPAIR OR REPLACE THE SUBJECT BRAKE BOOSTER VACUUM SUPPLY HOSE ASSEMBLY. THE ACTION TAKEN BY FORD IS SUFFICIENT TO RESOLVE THE ISSUES RAISED BY THIS INVESTIGATION.ACCORDINGLY, THIS INVESTIGATION IS CLOSED.
Additional source detail variants (3)
Service Brakes, Hydraulic:power Assist
BY LETTER DATED MAY 5, 2008, FORD MOTOR COMPANY (FORD) NOTIFIED THE AGENCY THAT IT WILL CONDUCT A SAFETY RECALL (NHTSA RECALL NUMBER 08V-208) TO ADDRESS A MANUFACTURING DEFECT IN APPROXIMATELY 605,684 MODEL YEAR (MY) 2005 AND 2006 FORD F-150 AND LINCOLN MARK LT VEHICLES ORIGINALLY EQUIPPED WITH THE 5.4L DISPLACEMENT, 3-VALVE PER CYLINDER, V-8 ENGINE.THE RECALLED VEHICLES WERE BUILT FROM JULY 18, 2004 THROUGH MAY 31, 2006 AT THE DEARBORN TRUCK PLANT; FROM MAY 4, 2004 THROUGH MAY 31, 2006 AT THE KANSAS CITY ASSEMBLY PLANT; AND FROM APRIL 19, 2004 THROUGH MAY 31, 2006 AT THE NORFOLK TRUCK PLANT.THE VEHICLES WERE MANUFACTURED WITH THE SAME DEFECTIVE BRAKE BOOSTER VACUUM SUPPLY HOSE ASSEMBLY UNIQUE TO THE 5.4L V-8 ENGINE.FORD F-150 VEHICLES EQUIPPED WITH OPTIONALLY AVAILABLE 4.2L V6 AND 4.6L V-8 ENGINES ARE NOT INCLUDED IN THIS RECALL ACTION BECAUSE THEY UTILIZE A DIFFERENT, ONE-PIECE BRAKE BOOSTER VACUUM SUPPLY HOSE ASSEMBLY THAT DOES NOT EXHIBIT AN APPARENT DEFECT TREND. THE RECALLED VEHICLES UTILIZE A TWO-PIECE BRAKE BOOSTER VACUUM SUPPLY HOSE ASSEMBLY COMPRISED OF A STANDPIPE ASSEMBLY AND VACUUM HOSE.THE STANDPIPE ASSEMBLY ATTACHES TO A FITTING ON THE ENGINE AIR INTAKE MANIFOLD UTILIZING A FLEXIBLE RUBBER HOSE AND PLASTIC ELBOW.THE VACUUM HOSE ATTACHES TO THE OPPOSITE END OF THE STANDPIPE ASSEMBLY AND CONNECTS TO A CHECK VALVE FITTING AT THE BRAKE BOOSTER ASSEMBLY.ACCORDING TO FORD, THE PORTION OF THE BRAKE BOOSTER VACUUM SUPPLY HOSE ASSEMBLY ATTACHED TO THE INTAKE MANIFOLD MAY SWELL OVER TIME AND LOSE RETENTION FORCE, WHICH MAY ALLOW THE HOSE TO BECOME DETACHED FROM THE INTAKE MANIFOLD.SHOULD THE BRAKE BOOSTER VACUUM SUPPLY HOSE ASSEMBLY BE DISRUPTED, APPLICATION OF THE BRAKE PEDAL MAY DEPLETE THE VACUUM RESERVE AND CONSEQUENTLY RESULT IN LOSS OF BRAKE POWER-ASSIST. TO CORRECT THE SAFETY DEFECT, FORD WILL INSTALL AN IMPROVED DESIGN BRAKE BOOSTER VACUUM SUPPLY HOSE ASSEMBLY THAT UTILIZES A HOSE CLAMP AT THE INTAKE MANIFOLD ATTACHMENT. THIS REMEDY WILL BE PROVIDED FREE OF CHARGE FOR ALL RECALLED VEHICLES.LATER PRODUCTION FORD F-150 AND LINCOLN MARK LT VEHICLES BUILT AFTER MAY 2006 WERE MANUFACTURED WITH A HOSE CLAMP AT THE BRAKE BOOSTER VACUUM SUPPLY HOSE/INTAKE MANIFOLD ATTACHMENT AND ARE NOT AFFECTED. TO DATE, THE OFFICE OF DEFECTS INVESTIGATION (ODI) IS AWARE OF 324 NON-DUPLICATIVE COMPLAINTS AND 14 NON-INJURY CRASHES RELATED TO THE ALLEGED DEFECT IN THE SUBJECT VEHICLES.IN ADDITION, ODI IS AWARE OF 4,465 SUBJECT VEHICLES THAT EXPERIENCED ONE OR MORE WARRANTY CLAIMS TO REPAIR OR REPLACE THE SUBJECT BRAKE BOOSTER VACUUM SUPPLY HOSE ASSEMBLY. THE ACTION TAKEN BY FORD IS SUFFICIENT TO RESOLVE THE ISSUES RAISED BY THIS INVESTIGATION.ACCORDINGLY, THIS INVESTIGATION IS CLOSED.
Service Brakes, Hydraulic:power Assist:vacuum
BY LETTER DATED MAY 5, 2008, FORD MOTOR COMPANY (FORD) NOTIFIED THE AGENCY THAT IT WILL CONDUCT A SAFETY RECALL (NHTSA RECALL NUMBER 08V-208) TO ADDRESS A MANUFACTURING DEFECT IN APPROXIMATELY 605,684 MODEL YEAR (MY) 2005 AND 2006 FORD F-150 AND LINCOLN MARK LT VEHICLES ORIGINALLY EQUIPPED WITH THE 5.4L DISPLACEMENT, 3-VALVE PER CYLINDER, V-8 ENGINE.THE RECALLED VEHICLES WERE BUILT FROM JULY 18, 2004 THROUGH MAY 31, 2006 AT THE DEARBORN TRUCK PLANT; FROM MAY 4, 2004 THROUGH MAY 31, 2006 AT THE KANSAS CITY ASSEMBLY PLANT; AND FROM APRIL 19, 2004 THROUGH MAY 31, 2006 AT THE NORFOLK TRUCK PLANT.THE VEHICLES WERE MANUFACTURED WITH THE SAME DEFECTIVE BRAKE BOOSTER VACUUM SUPPLY HOSE ASSEMBLY UNIQUE TO THE 5.4L V-8 ENGINE.FORD F-150 VEHICLES EQUIPPED WITH OPTIONALLY AVAILABLE 4.2L V6 AND 4.6L V-8 ENGINES ARE NOT INCLUDED IN THIS RECALL ACTION BECAUSE THEY UTILIZE A DIFFERENT, ONE-PIECE BRAKE BOOSTER VACUUM SUPPLY HOSE ASSEMBLY THAT DOES NOT EXHIBIT AN APPARENT DEFECT TREND. THE RECALLED VEHICLES UTILIZE A TWO-PIECE BRAKE BOOSTER VACUUM SUPPLY HOSE ASSEMBLY COMPRISED OF A STANDPIPE ASSEMBLY AND VACUUM HOSE.THE STANDPIPE ASSEMBLY ATTACHES TO A FITTING ON THE ENGINE AIR INTAKE MANIFOLD UTILIZING A FLEXIBLE RUBBER HOSE AND PLASTIC ELBOW.THE VACUUM HOSE ATTACHES TO THE OPPOSITE END OF THE STANDPIPE ASSEMBLY AND CONNECTS TO A CHECK VALVE FITTING AT THE BRAKE BOOSTER ASSEMBLY.ACCORDING TO FORD, THE PORTION OF THE BRAKE BOOSTER VACUUM SUPPLY HOSE ASSEMBLY ATTACHED TO THE INTAKE MANIFOLD MAY SWELL OVER TIME AND LOSE RETENTION FORCE, WHICH MAY ALLOW THE HOSE TO BECOME DETACHED FROM THE INTAKE MANIFOLD.SHOULD THE BRAKE BOOSTER VACUUM SUPPLY HOSE ASSEMBLY BE DISRUPTED, APPLICATION OF THE BRAKE PEDAL MAY DEPLETE THE VACUUM RESERVE AND CONSEQUENTLY RESULT IN LOSS OF BRAKE POWER-ASSIST. TO CORRECT THE SAFETY DEFECT, FORD WILL INSTALL AN IMPROVED DESIGN BRAKE BOOSTER VACUUM SUPPLY HOSE ASSEMBLY THAT UTILIZES A HOSE CLAMP AT THE INTAKE MANIFOLD ATTACHMENT. THIS REMEDY WILL BE PROVIDED FREE OF CHARGE FOR ALL RECALLED VEHICLES.LATER PRODUCTION FORD F-150 AND LINCOLN MARK LT VEHICLES BUILT AFTER MAY 2006 WERE MANUFACTURED WITH A HOSE CLAMP AT THE BRAKE BOOSTER VACUUM SUPPLY HOSE/INTAKE MANIFOLD ATTACHMENT AND ARE NOT AFFECTED. TO DATE, THE OFFICE OF DEFECTS INVESTIGATION (ODI) IS AWARE OF 324 NON-DUPLICATIVE COMPLAINTS AND 14 NON-INJURY CRASHES RELATED TO THE ALLEGED DEFECT IN THE SUBJECT VEHICLES.IN ADDITION, ODI IS AWARE OF 4,465 SUBJECT VEHICLES THAT EXPERIENCED ONE OR MORE WARRANTY CLAIMS TO REPAIR OR REPLACE THE SUBJECT BRAKE BOOSTER VACUUM SUPPLY HOSE ASSEMBLY. THE ACTION TAKEN BY FORD IS SUFFICIENT TO RESOLVE THE ISSUES RAISED BY THIS INVESTIGATION.ACCORDINGLY, THIS INVESTIGATION IS CLOSED.
Service Brakes, Hydraulic:power Assist:vacuum:hoses, Lines/piping, And Fittings
BY LETTER DATED MAY 5, 2008, FORD MOTOR COMPANY (FORD) NOTIFIED THE AGENCY THAT IT WILL CONDUCT A SAFETY RECALL (NHTSA RECALL NUMBER 08V-208) TO ADDRESS A MANUFACTURING DEFECT IN APPROXIMATELY 605,684 MODEL YEAR (MY) 2005 AND 2006 FORD F-150 AND LINCOLN MARK LT VEHICLES ORIGINALLY EQUIPPED WITH THE 5.4L DISPLACEMENT, 3-VALVE PER CYLINDER, V-8 ENGINE.THE RECALLED VEHICLES WERE BUILT FROM JULY 18, 2004 THROUGH MAY 31, 2006 AT THE DEARBORN TRUCK PLANT; FROM MAY 4, 2004 THROUGH MAY 31, 2006 AT THE KANSAS CITY ASSEMBLY PLANT; AND FROM APRIL 19, 2004 THROUGH MAY 31, 2006 AT THE NORFOLK TRUCK PLANT.THE VEHICLES WERE MANUFACTURED WITH THE SAME DEFECTIVE BRAKE BOOSTER VACUUM SUPPLY HOSE ASSEMBLY UNIQUE TO THE 5.4L V-8 ENGINE.FORD F-150 VEHICLES EQUIPPED WITH OPTIONALLY AVAILABLE 4.2L V6 AND 4.6L V-8 ENGINES ARE NOT INCLUDED IN THIS RECALL ACTION BECAUSE THEY UTILIZE A DIFFERENT, ONE-PIECE BRAKE BOOSTER VACUUM SUPPLY HOSE ASSEMBLY THAT DOES NOT EXHIBIT AN APPARENT DEFECT TREND. THE RECALLED VEHICLES UTILIZE A TWO-PIECE BRAKE BOOSTER VACUUM SUPPLY HOSE ASSEMBLY COMPRISED OF A STANDPIPE ASSEMBLY AND VACUUM HOSE.THE STANDPIPE ASSEMBLY ATTACHES TO A FITTING ON THE ENGINE AIR INTAKE MANIFOLD UTILIZING A FLEXIBLE RUBBER HOSE AND PLASTIC ELBOW.THE VACUUM HOSE ATTACHES TO THE OPPOSITE END OF THE STANDPIPE ASSEMBLY AND CONNECTS TO A CHECK VALVE FITTING AT THE BRAKE BOOSTER ASSEMBLY.ACCORDING TO FORD, THE PORTION OF THE BRAKE BOOSTER VACUUM SUPPLY HOSE ASSEMBLY ATTACHED TO THE INTAKE MANIFOLD MAY SWELL OVER TIME AND LOSE RETENTION FORCE, WHICH MAY ALLOW THE HOSE TO BECOME DETACHED FROM THE INTAKE MANIFOLD.SHOULD THE BRAKE BOOSTER VACUUM SUPPLY HOSE ASSEMBLY BE DISRUPTED, APPLICATION OF THE BRAKE PEDAL MAY DEPLETE THE VACUUM RESERVE AND CONSEQUENTLY RESULT IN LOSS OF BRAKE POWER-ASSIST. TO CORRECT THE SAFETY DEFECT, FORD WILL INSTALL AN IMPROVED DESIGN BRAKE BOOSTER VACUUM SUPPLY HOSE ASSEMBLY THAT UTILIZES A HOSE CLAMP AT THE INTAKE MANIFOLD ATTACHMENT. THIS REMEDY WILL BE PROVIDED FREE OF CHARGE FOR ALL RECALLED VEHICLES.LATER PRODUCTION FORD F-150 AND LINCOLN MARK LT VEHICLES BUILT AFTER MAY 2006 WERE MANUFACTURED WITH A HOSE CLAMP AT THE BRAKE BOOSTER VACUUM SUPPLY HOSE/INTAKE MANIFOLD ATTACHMENT AND ARE NOT AFFECTED. TO DATE, THE OFFICE OF DEFECTS INVESTIGATION (ODI) IS AWARE OF 324 NON-DUPLICATIVE COMPLAINTS AND 14 NON-INJURY CRASHES RELATED TO THE ALLEGED DEFECT IN THE SUBJECT VEHICLES.IN ADDITION, ODI IS AWARE OF 4,465 SUBJECT VEHICLES THAT EXPERIENCED ONE OR MORE WARRANTY CLAIMS TO REPAIR OR REPLACE THE SUBJECT BRAKE BOOSTER VACUUM SUPPLY HOSE ASSEMBLY. THE ACTION TAKEN BY FORD IS SUFFICIENT TO RESOLVE THE ISSUES RAISED BY THIS INVESTIGATION.ACCORDINGLY, THIS INVESTIGATION IS CLOSED.
2006 Ford F-150 Problems, Complaints & Recalls | Skip That Year