BRAKE PEDAL ON 2005 F150 FADES EVEN WITH BRAND NEW PADS INSTALLED. *TR
2005 Ford F-150
Owner reports · Recalls · Investigations
Similar to other model years
Owner complaints for the 2005 Ford F-150 do not stand out strongly from the model-year median of 676.
About this comparison →How this year compares
Owner complaints by model year
Compare all F-150 years →Counts vary with age, sales and reporting. They are not failure rates.
What owners reported most
All reported categories
Tap a category to read its complaints. One report may name several components.
When problems were reported
Mileage at the reported incident
973 reports with mileage · 139 unknown
NHTSA’s mileage field refers to the reported incident, not necessarily the filing date. This shows report counts, not the likelihood of a failure.
What to inspect
Issues worth paying extra attention to based on owner reports.
- Visibility. Review the 260 owner reports in this category and discuss these concerns during a pre-purchase inspection. Read reports →
- Engine. Review the 117 owner reports in this category and discuss these concerns during a pre-purchase inspection. Read reports →
- Power Train. Review the 112 owner reports in this category and discuss these concerns during a pre-purchase inspection. Read reports →
NHTSA owner reports · September 18, 2026 snapshot.
Service Brakes, Hydraulic complaints
90 reportsWAS DRIVING MY 2005 F-150 ELT ON 4 LANE DIVIDED HIGHWAY AT APPROX 65-70 MPH. WHEN APPLIED THE BRAKES FELT SLIGHT PULL TO THE RIGHT. BEGAN SMELLING STRONG ODOR ONCE ENTERED TOWN AND WAS SLOWED TO 35 MPH. DROVE ANOTHER 2-3 MILES TO HOME AND SMELL INTENSIFIED. ONCE EXITED THE TRUCK SAW SMOKE COMING FROM THE DRIVERSFRONT TIRE. FRONT…
Read full complaint
WAS DRIVING MY 2005 F-150 ELT ON 4 LANE DIVIDED HIGHWAY AT APPROX 65-70 MPH. WHEN APPLIED THE BRAKES FELT SLIGHT PULL TO THE RIGHT. BEGAN SMELLING STRONG ODOR ONCE ENTERED TOWN AND WAS SLOWED TO 35 MPH. DROVE ANOTHER 2-3 MILES TO HOME AND SMELL INTENSIFIED. ONCE EXITED THE TRUCK SAW SMOKE COMING FROM THE DRIVERSFRONT TIRE. FRONT WHEEL WAS ALSO EXTREMELY HOT, WAS UNABLE TO TOUCH IT.
TL*THE CONTACT OWNS A 2005 FORD F-150. THE CONTACT STATED THAT THE BRAKE PEDAL WAS TO CLOSE TO THE GAS PEDAL. THE CONTACT APPROACHED A RED LIGHT, ENGAGED THE BRAKE PEDAL AND ACCELERATOR PEDAL SIMULTANEOUSLY. THE VEHICLE LUNGED FORWARD JUST ENOUGH TO HIT THE VEHICLE IN FRONT OF HIM AT 10 MPH. THE CURRENT AND FAILURE MILEAGES WER…
Read full complaint
TL*THE CONTACT OWNS A 2005 FORD F-150. THE CONTACT STATED THAT THE BRAKE PEDAL WAS TO CLOSE TO THE GAS PEDAL. THE CONTACT APPROACHED A RED LIGHT, ENGAGED THE BRAKE PEDAL AND ACCELERATOR PEDAL SIMULTANEOUSLY. THE VEHICLE LUNGED FORWARD JUST ENOUGH TO HIT THE VEHICLE IN FRONT OF HIM AT 10 MPH. THE CURRENT AND FAILURE MILEAGES WERE 50,000. UPDATED 11/16/10. *LJ
THE FOLLOWING INCIDENT HAS BEEN FILED WITH THE FORD MOTOR COMPANY. I WANT TO BE CLEAR THAT THIS INCIDENT WAS NOT THE RESULT OF A FLOOR MAT OR DRIVER ERROR. AT NO TIME DID THE DRIVER HAVE HER FOOT ON THE ACCELERATOR NOR WAS THERE AN OBJECT ON, AROUND, UNDER, OR OVER THE ACCELERATOR. INCIDENT: ON 18 FEBRUARY 2010 AT APPROX…
Read full complaint
THE FOLLOWING INCIDENT HAS BEEN FILED WITH THE FORD MOTOR COMPANY. I WANT TO BE CLEAR THAT THIS INCIDENT WAS NOT THE RESULT OF A FLOOR MAT OR DRIVER ERROR. AT NO TIME DID THE DRIVER HAVE HER FOOT ON THE ACCELERATOR NOR WAS THERE AN OBJECT ON, AROUND, UNDER, OR OVER THE ACCELERATOR. INCIDENT: ON 18 FEBRUARY 2010 AT APPROXIMATELY 1230 PM MY WIFE, MOTHER IN-LAW, FATHER IN-LAW AND INFANT DAUGHTER WERE PROCEEDING NORTHBOUND ON WATER TOWER RD. LOCATED IN BENTONVILLE, AR. THERE WERE ZERO DISTRACTIONS INSIDE THE VEHICLE AND MY WIFE WAS FULLY ALERT WITH NO PHYSICAL IMPAIRMENTS. ROAD CONDITIONS WERE DRY AND WEATHER WAS SUNNY WITH GREAT VISIBILITY. AS THEY APPROACHED THE INTERSECTION OF WATER TOWER RD. AND BATTLEFIELD BLVD. AT APPROXIMATELY 5-10 MILES PER HOUR, MY WIFE BEGAN BREAKING. AFTER PLACING HER RIGHT FOOT ON THE BRAKE PEDAL, SHE IMMEDIATELY NOTICED/HEARD/FELT/EXPERIENCED INCREASED ACCELERATION AND DECREASED BREAKING POWER DURING HER ATTEMPTS TO STOP. SHE IMMEDIATELY INCREASED PRESSURE ON THE BRAKE PEDAL ENSURING HER RIGHT FOOT WAS NOT ON THE ACCELERATOR. THE ENGINE CONTINUED ITS EFFORTS TO INCREASE SPEED WHILE MY WIFE FOUGHT TO BRING THE VEHICLE TO A STOP. THEY PROCEEDED INTO AND THROUGH THE VACANT INTERSECTION AT APPROXIMATELY 5-10 MILES PER HOUR AND FORTUNATELY WITHOUT INCIDENT. MY WIFE'S EFFORTS TO STOP THE VEHICLE CONTINUED BEYOND THE INTERSECTION FOR AN APPROXIMATE 150 - 200 FEET. THE VEHICLE FINALLY CEASED ITS EFFORTS TO ACCELERATE AND CAME TO REST AT THAT POINT. AFTER REGAINING THEIR COMPOSURE, MY WIFE PUMPED THE BRAKES IN EFFORT TO DETERMINE THE MALFUNCTION. UNABLE TO DETERMINE THE PROBLEM AND FEELING COMFORTABLE TO DRIVE AGAIN, THEY PROCEEDED CAUTIOUSLY ONLY TO HAVE THIS HAPPEN ONCE MORE. THIS SECOND OCCURRENCE HAPPENED LESS THAN MILE FROM THE PREVIOUS LOCATION WITH MY WIFE BEING PREPARED FOR THE MALFUNCTION. DURING THIS OCCURRENCE SHE PUMPED THE BRAKES AND STOPPED THE INCREASED REVOLUTIONS OF THE ENGINE IMMEDIATELY. *TR
HAD TO REPLACE WHEEL BEARING, PADS AND ROTORS AT 33000 MILES. 5000 MILES LATER CALIPER FROZE LOCKING BRAKES. ANOTHER BRAKE JOB HAD TO BE DONE. *TR
LOSS OF BRAKES, BRAKING WHILE GOING DOWNHILL, LOSS OF BRAKES, ABS NOT WORKING THEN WORKING. *TR
TL* THE CONTACT OWNS A 2005 FORD F-150. THE BRAKES LOCK WHENEVER HE DRIVES THE VEHICLE. THE BRAKE PADS, ROTORS AND BRAKE LINE WERE REPLACED. THE REPAIRS DID NOT REMEDY THE FAILURE. THE DEALER NOR THE MANUFACTURER HAVE BEEN CONTACTED. THE FAILURE MILEAGE 36,000.
2005 F150 4X2 REGULAR CAB. . PURCHASED NEW FROM AL PACKERD FORD, ROYAL PALM BEACH, FL. I HAVE NOTICED A VIBRATION/SHUDDER, FROM INTERMITTENTLY TO CONTINUOUSLY ON SHORT TRIPS. ON LONGER TRIPS I NOTICED A COUPLE TIMES AN ODOR OF SOMETHING BURNING. I BROUGHT IT TO ADVANTAGE FORD, 4000 SE FEDERAL HIGHWAY.PO BOX 2930, STUART, FL. 349…
Read full complaint
2005 F150 4X2 REGULAR CAB. . PURCHASED NEW FROM AL PACKERD FORD, ROYAL PALM BEACH, FL. I HAVE NOTICED A VIBRATION/SHUDDER, FROM INTERMITTENTLY TO CONTINUOUSLY ON SHORT TRIPS. ON LONGER TRIPS I NOTICED A COUPLE TIMES AN ODOR OF SOMETHING BURNING. I BROUGHT IT TO ADVANTAGE FORD, 4000 SE FEDERAL HIGHWAY.PO BOX 2930, STUART, FL. 34995, PHONE: 772-287-0955, TO HAVE IT INSPECTED AND THEY SAID I NEEDED A BRAKE CALIPER ON THE RIGHT PASSENGER SIDE. MILEAGE AT TIME OF INSPECTION: 62,701. MY CONCERN IS THAT THIS IS A SAFETY DEFECT AND A MANUFACTURER DEFECT AS WELL. *TR
TL*THE CONTACT OWNS A 2005 FORD F150. WHEN THE CONTACT DEPRESSED THE BRAKE PEDAL, THE FRONT END OF THE VEHICLE VIBRATED. HE REPLACED THE ROTORS, BRAKE PADS, AND FRONT DISCS AT LEAST TWICE, BUT THE FAILURE STILL PERSISTS. THE DEALER AND MANUFACTURER STATED THAT THERE WERE NO RECALLS ON THE VEHICLE REGARDING THE BRAKES. THE FA…
Read full complaint
TL*THE CONTACT OWNS A 2005 FORD F150. WHEN THE CONTACT DEPRESSED THE BRAKE PEDAL, THE FRONT END OF THE VEHICLE VIBRATED. HE REPLACED THE ROTORS, BRAKE PADS, AND FRONT DISCS AT LEAST TWICE, BUT THE FAILURE STILL PERSISTS. THE DEALER AND MANUFACTURER STATED THAT THERE WERE NO RECALLS ON THE VEHICLE REGARDING THE BRAKES. THE FAILURE MILEAGE WAS 29,300 AND CURRENT MILEAGE WAS 30,150.
2005 FORD F-150 SUPERCREW WITH BAD SHAKING/VIBRATION. CONSUMER STATES THAT THE DEALER REPLACED THE CALIPERS, BRAKE PADS, AND MACHINED THE ROTORS. CONSUMER FOUND OUT ABOUT TSB'S FOR THIS EXACT PROBLEM WITH THE MODEL AND MODEL YEAR TRUCK. *KB
Official recalls
311V107000 · Air Bags:frontal:driver Side:inflator Module
Feb 23, 2011
FORD IS RECALLING CERTAIN MODEL YEAR 2004-2006 F-150 PICK UP TRUCKS AS WELL AS CERTAIN MODEL YEAR 2006 LINCOLN MARK LT VEHICLES. IF THE CLOCKSPRING JUMPER WIRE COMES IN CONTACT WITH THE DRIVER SIDE FRONTAL AIR BAG LOWER HORN PLATE, THE WIRE INSULATION MAY BECOME CHAFED, CREATING A POTENTIAL FOR A SHORT CIRCUIT. IF THIS OCCURS THE AIR BAG WARNING LAMP MAY ILLUMINATE INDICATING THAT SERVICE IS REQUIRED.
Consequence & remedy
Consequence: THE DRIVER SIDE FRONTAL AIR BAG COULD INADVERTENTLY DEPLOY INCREASING THE RISK OF INJURY OR LOSS OF VEHICLE CONTROL IF OCCURRING WHILE IN MOTION.
Remedy: FORD WILL NOTIFY OWNERS AND INSTRUCT THEM TO TAKE THEIR VEHICLES TO A FORD OR LINCOLN/MERCURY DEALER TO HAVE A NEW CLOCKSPRING JUMPER WIRE INSTALLED THAT INCORPORATES A PROTECTIVE MESH COVER. REPAIRS WILL BE PERFORMED FREE OF CHARGE. THIS SAFETY RECALL BEGAN ON SOME VEHICLES IN MARCH 2011. THE RECALL CAMPAIGN ON THE EXPANDED POPULATION IS EXPECTED TO BEGIN ON OR ABOUT MAY 9, 2011. OWNERS MAY CONTACT THE FORD MOTOR COMPANY CUSTOMER RELATIONSHIP CENTER AT 1-866-436-7332.
08V208000 · Service Brakes, Hydraulic:power Assist:vacuum:hoses, Lines/piping, And Fittings
May 7, 2008
FORD IS RECALLING 605,684 MY 2005-2006 F-150 AND LINCOLN MARK LT VEHICLES EQUIPPED WITH 5.4L 3-VALVE ENGINES. THE BRAKE BOOSTER VACUUM SUPPLY HOSE ATTACHED TO THE INTAKE MANIFOLD FITTING MAY SWELL OVER TIME AND LOSE RETENTION FORCE. THIS CONDITION COULD ALLOW THE HOSE TO BECOME DETACHED FROM THE FITTING DURING AN INTAKE MANIFOLD BACKFIRE. SHOULD THE HOSE DETACH FROM THE INTAKE MANIFOLD, SEVERAL BRAKE APPLICATIONS WITH POWER ASSIST WILL BE AVAILABLE BEFORE THE VACUUM RESERVE IS DEPLETED.
Consequence & remedy
Consequence: ONCE THE BRAKE BOOSTER VACUUM RESERVE IS DEPLETED, THE DRIVER WILL HAVE FOUNDATION BRAKE FUNCTION, BUT WITH INCREASED BRAKE PEDAL EFFORT. REDUCED VEHICLE BRAKING COULD LEAD TO A CRASH.
Remedy: DEALERS WILL REPLACE A RUBBER HOSE ON THE BRAKE BOOSTER VACUUM SUPPLY TUBE ASSEMBLY. THE RECALL BEGAN ON JUNE 27, 2008. OWNERS MAY CONTACT FORD AT 1-800-392-3673.
06V033000 · Interior Lighting
Feb 6, 2006
CERTAIN PICKUP TRUCKS FAIL TO COMPLY WITH EITHER THE REQUIREMENTS OF FEDERAL MOTOR VEHICLE SAFETY STANDARD (FMVSS) NO. 105, 'HYDRAULIC AND ELECTRIC BRAKE SYSTEMS' OR FMVSS NO. 135, 'PASSENGER CAR BRAKE SYSTEMS.' THESE VEHICLES WERE BUILT WITH A SOFTWARE ERROR IN THE INSTRUMENT CLUSTER.
Consequence & remedy
Consequence: THIS ERROR COULD PREVENT THE ANTILOCK BRAKE SYSTEM (ABS) WARNING LIGHT FROM ILLUMINATING IF THE ABS MODULE EVER BECAME INOPERATIVE.
Remedy: DEALERS WILL RECALIBRATE THE INSTRUMENT CLUSTER IN THESE VEHICLES. THE RECALL BEGAN ON FEBRUARY 27, 2006. OWNERS MAY CONTACT FORD AT 1-800-392-3673.
Model-level recall history does not show whether a particular VIN is affected or has received a repair. Check a VIN with NHTSA ↗
NHTSA investigations
3EA10001 · Inadvertent Airbag Deployment
Opened Jan 13, 2010 · Closed Apr 25, 2011
Status: closed (inferred from source dates) · Air Bags; Air Bags:frontal; Air Bags:frontal:driver Side:inflator Module; Air Bags:frontal:sensor/control MODULE-INACTIVE
ODI opened this investigation based on reports of inadvertent airbag deployment.Data provided by Ford indicated that the airbag clockspring jumper wire, which is situated inside the steering wheel assembly, was installed in a manner that would allow it to rub (abrade) against a sharp metal edge on the nearby horn plate.Because the horn plate is electrically grounded the abrasion of an airbag wire on the sharp edge could cause a short circuit condition.As a result the airbag light may illuminate and/or the airbag may inadvertently deploy.Inadvertent deployments are most likely to occur during the airbag system's self-diagnostic test that initiates when the ignition switch is turned on.Ford modified the vehicle design in late January 2006 adding a protective tape over the sharp metal edge of the horn plate.Ford made additional design changes on MY 2007 vehicles to the horn plate, the clockspring jumper, and the connector layouts to further address this issue.ODI identified 318 deployment incidents with 121 alleged injury reports from subject vehicles.All but one of the incident and injury reports occurred in vehicles built before the January 2006 modification.In addition, there was one incident and alleged injury reported in the MY 2006 Mark LT vehicles that share the same design. In letters dated February 21 and April 11, 2011, Ford announced a recall of all of the approximately 1.3 million MY 2004-2006 F-150 vehicles built prior to January 24, 2006, the date the initial vehicle modification was made.In addition, approximately 14,000 MY 2006 Mark LT vehicles built prior to January 24, 2006 will also be recalled.Vehicles built after that date, which contain the modification, are not within the recall scope.Accordingly the investigation is closed.
Additional source detail variants (4)
Air Bags
ODI opened this investigation based on reports of inadvertent airbag deployment.Data provided by Ford indicated that the airbag clockspring jumper wire, which is situated inside the steering wheel assembly, was installed in a manner that would allow it to rub (abrade) against a sharp metal edge on the nearby horn plate.Because the horn plate is electrically grounded the abrasion of an airbag wire on the sharp edge could cause a short circuit condition.As a result the airbag light may illuminate and/or the airbag may inadvertently deploy.Inadvertent deployments are most likely to occur during the airbag system's self-diagnostic test that initiates when the ignition switch is turned on.Ford modified the vehicle design in late January 2006 adding a protective tape over the sharp metal edge of the horn plate.Ford made additional design changes on MY 2007 vehicles to the horn plate, the clockspring jumper, and the connector layouts to further address this issue.ODI identified 318 deployment incidents with 121 alleged injury reports from subject vehicles.All but one of the incident and injury reports occurred in vehicles built before the January 2006 modification.In addition, there was one incident and alleged injury reported in the MY 2006 Mark LT vehicles that share the same design. In letters dated February 21 and April 11, 2011, Ford announced a recall of all of the approximately 1.3 million MY 2004-2006 F-150 vehicles built prior to January 24, 2006, the date the initial vehicle modification was made.In addition, approximately 14,000 MY 2006 Mark LT vehicles built prior to January 24, 2006 will also be recalled.Vehicles built after that date, which contain the modification, are not within the recall scope.Accordingly the investigation is closed.
Air Bags:frontal:driver Side:inflator Module
ODI opened this investigation based on reports of inadvertent airbag deployment.Data provided by Ford indicated that the airbag clockspring jumper wire, which is situated inside the steering wheel assembly, was installed in a manner that would allow it to rub (abrade) against a sharp metal edge on the nearby horn plate.Because the horn plate is electrically grounded the abrasion of an airbag wire on the sharp edge could cause a short circuit condition.As a result the airbag light may illuminate and/or the airbag may inadvertently deploy.Inadvertent deployments are most likely to occur during the airbag system's self-diagnostic test that initiates when the ignition switch is turned on.Ford modified the vehicle design in late January 2006 adding a protective tape over the sharp metal edge of the horn plate.Ford made additional design changes on MY 2007 vehicles to the horn plate, the clockspring jumper, and the connector layouts to further address this issue.ODI identified 318 deployment incidents with 121 alleged injury reports from subject vehicles.All but one of the incident and injury reports occurred in vehicles built before the January 2006 modification.In addition, there was one incident and alleged injury reported in the MY 2006 Mark LT vehicles that share the same design. In letters dated February 21 and April 11, 2011, Ford announced a recall of all of the approximately 1.3 million MY 2004-2006 F-150 vehicles built prior to January 24, 2006, the date the initial vehicle modification was made.In addition, approximately 14,000 MY 2006 Mark LT vehicles built prior to January 24, 2006 will also be recalled.Vehicles built after that date, which contain the modification, are not within the recall scope.Accordingly the investigation is closed.
Air Bags:frontal
ODI opened this investigation based on reports of inadvertent airbag deployment.Data provided by Ford indicated that the airbag clockspring jumper wire, which is situated inside the steering wheel assembly, was installed in a manner that would allow it to rub (abrade) against a sharp metal edge on the nearby horn plate.Because the horn plate is electrically grounded the abrasion of an airbag wire on the sharp edge could cause a short circuit condition.As a result the airbag light may illuminate and/or the airbag may inadvertently deploy.Inadvertent deployments are most likely to occur during the airbag system's self-diagnostic test that initiates when the ignition switch is turned on.Ford modified the vehicle design in late January 2006 adding a protective tape over the sharp metal edge of the horn plate.Ford made additional design changes on MY 2007 vehicles to the horn plate, the clockspring jumper, and the connector layouts to further address this issue.ODI identified 318 deployment incidents with 121 alleged injury reports from subject vehicles.All but one of the incident and injury reports occurred in vehicles built before the January 2006 modification.In addition, there was one incident and alleged injury reported in the MY 2006 Mark LT vehicles that share the same design. In letters dated February 21 and April 11, 2011, Ford announced a recall of all of the approximately 1.3 million MY 2004-2006 F-150 vehicles built prior to January 24, 2006, the date the initial vehicle modification was made.In addition, approximately 14,000 MY 2006 Mark LT vehicles built prior to January 24, 2006 will also be recalled.Vehicles built after that date, which contain the modification, are not within the recall scope.Accordingly the investigation is closed.
Air Bags:frontal:sensor/control MODULE-INACTIVE
ODI opened this investigation based on reports of inadvertent airbag deployment.Data provided by Ford indicated that the airbag clockspring jumper wire, which is situated inside the steering wheel assembly, was installed in a manner that would allow it to rub (abrade) against a sharp metal edge on the nearby horn plate.Because the horn plate is electrically grounded the abrasion of an airbag wire on the sharp edge could cause a short circuit condition.As a result the airbag light may illuminate and/or the airbag may inadvertently deploy.Inadvertent deployments are most likely to occur during the airbag system's self-diagnostic test that initiates when the ignition switch is turned on.Ford modified the vehicle design in late January 2006 adding a protective tape over the sharp metal edge of the horn plate.Ford made additional design changes on MY 2007 vehicles to the horn plate, the clockspring jumper, and the connector layouts to further address this issue.ODI identified 318 deployment incidents with 121 alleged injury reports from subject vehicles.All but one of the incident and injury reports occurred in vehicles built before the January 2006 modification.In addition, there was one incident and alleged injury reported in the MY 2006 Mark LT vehicles that share the same design. In letters dated February 21 and April 11, 2011, Ford announced a recall of all of the approximately 1.3 million MY 2004-2006 F-150 vehicles built prior to January 24, 2006, the date the initial vehicle modification was made.In addition, approximately 14,000 MY 2006 Mark LT vehicles built prior to January 24, 2006 will also be recalled.Vehicles built after that date, which contain the modification, are not within the recall scope.Accordingly the investigation is closed.
PE09046 · Inadvertent Airbag Deployment
Opened Sep 24, 2009 · Closed Jan 19, 2010
Status: closed (inferred from source dates) · Air Bags; Air Bags:frontal; Air Bags:frontal:driver Side:inflator Module; Air Bags:frontal:sensor/control MODULE-INACTIVE
FORD REPORTS THAT THE INADVERTENT AIRBAG DEPLOYMENTS ARE MOST LIKELY CAUSED BY THE AIRBAG HORN MOUNTING PLATE'S SHARP METAL EDGE THAT EVENTUALLY CAN CHAFE/CUT THE AIRBAG CLOCKSPRING JUMPER WIRE LEADING TO A SHORT-TO-GROUND CONDITION.ONE HUNDRED EIGHTY TWO (182) OF THE 230 REPORTS WERE FOR AIRBAG DEPLOYMENTS RESULTING IN 56 INJURIES WITH REMAINING 48 REPORTS FOR AN AIRBAG LIGHT ILLUMINATION CONDITION.INJURIES INCLUDE ABRASION, CONTUSION AND CUTS TO THE ARM/HAND/FACE AND/OR UPPER BODY REGIONS.ONE OWNER REPORTED A BROKEN TOOTH AND TWO OWNERS REPORTED BEING KNOCKED UNCONSCIOUS AS A RESULT OF THE AIRBAG DEPLOYMENT.IN ADDITION, MY2004 AND MY2006 F-150 VEHICLES ALSO CONTAIN THE SAME DESIGN THAT RESULTED IN AN ADDITIONAL 89 REPORTS WITH 37 AIRBAG DEPLOYMENTS AND NINE INJURIES. FORD MADE AN INTERIM DESIGN CHANGE TO THE HORN MOUNTING PLATE IN JANUARY 2006 AND THEN MAJOR CHANGES TO THE HORN MOUNTING PLATE, AIRBAG MODULE AND CLOCKSPRING JUMPER WIRE DESIGNS IN JUNE 2006 FOR THE MY2007 VEHICLES.THIS PRELIMINARY EVALUATION IS UPGRADED TO AN ENGINEERING ANALYSIS (EA10-001) TO INCLUDE MY2004-2006 F-150 VEHICLES AND TO FURTHER EVALUATE THE CONDITION.
Additional source detail variants (4)
Air Bags
FORD REPORTS THAT THE INADVERTENT AIRBAG DEPLOYMENTS ARE MOST LIKELY CAUSED BY THE AIRBAG HORN MOUNTING PLATE'S SHARP METAL EDGE THAT EVENTUALLY CAN CHAFE/CUT THE AIRBAG CLOCKSPRING JUMPER WIRE LEADING TO A SHORT-TO-GROUND CONDITION.ONE HUNDRED EIGHTY TWO (182) OF THE 230 REPORTS WERE FOR AIRBAG DEPLOYMENTS RESULTING IN 56 INJURIES WITH REMAINING 48 REPORTS FOR AN AIRBAG LIGHT ILLUMINATION CONDITION.INJURIES INCLUDE ABRASION, CONTUSION AND CUTS TO THE ARM/HAND/FACE AND/OR UPPER BODY REGIONS.ONE OWNER REPORTED A BROKEN TOOTH AND TWO OWNERS REPORTED BEING KNOCKED UNCONSCIOUS AS A RESULT OF THE AIRBAG DEPLOYMENT.IN ADDITION, MY2004 AND MY2006 F-150 VEHICLES ALSO CONTAIN THE SAME DESIGN THAT RESULTED IN AN ADDITIONAL 89 REPORTS WITH 37 AIRBAG DEPLOYMENTS AND NINE INJURIES. FORD MADE AN INTERIM DESIGN CHANGE TO THE HORN MOUNTING PLATE IN JANUARY 2006 AND THEN MAJOR CHANGES TO THE HORN MOUNTING PLATE, AIRBAG MODULE AND CLOCKSPRING JUMPER WIRE DESIGNS IN JUNE 2006 FOR THE MY2007 VEHICLES.THIS PRELIMINARY EVALUATION IS UPGRADED TO AN ENGINEERING ANALYSIS (EA10-001) TO INCLUDE MY2004-2006 F-150 VEHICLES AND TO FURTHER EVALUATE THE CONDITION.
Air Bags:frontal:driver Side:inflator Module
FORD REPORTS THAT THE INADVERTENT AIRBAG DEPLOYMENTS ARE MOST LIKELY CAUSED BY THE AIRBAG HORN MOUNTING PLATE'S SHARP METAL EDGE THAT EVENTUALLY CAN CHAFE/CUT THE AIRBAG CLOCKSPRING JUMPER WIRE LEADING TO A SHORT-TO-GROUND CONDITION.ONE HUNDRED EIGHTY TWO (182) OF THE 230 REPORTS WERE FOR AIRBAG DEPLOYMENTS RESULTING IN 56 INJURIES WITH REMAINING 48 REPORTS FOR AN AIRBAG LIGHT ILLUMINATION CONDITION.INJURIES INCLUDE ABRASION, CONTUSION AND CUTS TO THE ARM/HAND/FACE AND/OR UPPER BODY REGIONS.ONE OWNER REPORTED A BROKEN TOOTH AND TWO OWNERS REPORTED BEING KNOCKED UNCONSCIOUS AS A RESULT OF THE AIRBAG DEPLOYMENT.IN ADDITION, MY2004 AND MY2006 F-150 VEHICLES ALSO CONTAIN THE SAME DESIGN THAT RESULTED IN AN ADDITIONAL 89 REPORTS WITH 37 AIRBAG DEPLOYMENTS AND NINE INJURIES. FORD MADE AN INTERIM DESIGN CHANGE TO THE HORN MOUNTING PLATE IN JANUARY 2006 AND THEN MAJOR CHANGES TO THE HORN MOUNTING PLATE, AIRBAG MODULE AND CLOCKSPRING JUMPER WIRE DESIGNS IN JUNE 2006 FOR THE MY2007 VEHICLES.THIS PRELIMINARY EVALUATION IS UPGRADED TO AN ENGINEERING ANALYSIS (EA10-001) TO INCLUDE MY2004-2006 F-150 VEHICLES AND TO FURTHER EVALUATE THE CONDITION.
Air Bags:frontal
FORD REPORTS THAT THE INADVERTENT AIRBAG DEPLOYMENTS ARE MOST LIKELY CAUSED BY THE AIRBAG HORN MOUNTING PLATE'S SHARP METAL EDGE THAT EVENTUALLY CAN CHAFE/CUT THE AIRBAG CLOCKSPRING JUMPER WIRE LEADING TO A SHORT-TO-GROUND CONDITION.ONE HUNDRED EIGHTY TWO (182) OF THE 230 REPORTS WERE FOR AIRBAG DEPLOYMENTS RESULTING IN 56 INJURIES WITH REMAINING 48 REPORTS FOR AN AIRBAG LIGHT ILLUMINATION CONDITION.INJURIES INCLUDE ABRASION, CONTUSION AND CUTS TO THE ARM/HAND/FACE AND/OR UPPER BODY REGIONS.ONE OWNER REPORTED A BROKEN TOOTH AND TWO OWNERS REPORTED BEING KNOCKED UNCONSCIOUS AS A RESULT OF THE AIRBAG DEPLOYMENT.IN ADDITION, MY2004 AND MY2006 F-150 VEHICLES ALSO CONTAIN THE SAME DESIGN THAT RESULTED IN AN ADDITIONAL 89 REPORTS WITH 37 AIRBAG DEPLOYMENTS AND NINE INJURIES. FORD MADE AN INTERIM DESIGN CHANGE TO THE HORN MOUNTING PLATE IN JANUARY 2006 AND THEN MAJOR CHANGES TO THE HORN MOUNTING PLATE, AIRBAG MODULE AND CLOCKSPRING JUMPER WIRE DESIGNS IN JUNE 2006 FOR THE MY2007 VEHICLES.THIS PRELIMINARY EVALUATION IS UPGRADED TO AN ENGINEERING ANALYSIS (EA10-001) TO INCLUDE MY2004-2006 F-150 VEHICLES AND TO FURTHER EVALUATE THE CONDITION.
Air Bags:frontal:sensor/control MODULE-INACTIVE
FORD REPORTS THAT THE INADVERTENT AIRBAG DEPLOYMENTS ARE MOST LIKELY CAUSED BY THE AIRBAG HORN MOUNTING PLATE'S SHARP METAL EDGE THAT EVENTUALLY CAN CHAFE/CUT THE AIRBAG CLOCKSPRING JUMPER WIRE LEADING TO A SHORT-TO-GROUND CONDITION.ONE HUNDRED EIGHTY TWO (182) OF THE 230 REPORTS WERE FOR AIRBAG DEPLOYMENTS RESULTING IN 56 INJURIES WITH REMAINING 48 REPORTS FOR AN AIRBAG LIGHT ILLUMINATION CONDITION.INJURIES INCLUDE ABRASION, CONTUSION AND CUTS TO THE ARM/HAND/FACE AND/OR UPPER BODY REGIONS.ONE OWNER REPORTED A BROKEN TOOTH AND TWO OWNERS REPORTED BEING KNOCKED UNCONSCIOUS AS A RESULT OF THE AIRBAG DEPLOYMENT.IN ADDITION, MY2004 AND MY2006 F-150 VEHICLES ALSO CONTAIN THE SAME DESIGN THAT RESULTED IN AN ADDITIONAL 89 REPORTS WITH 37 AIRBAG DEPLOYMENTS AND NINE INJURIES. FORD MADE AN INTERIM DESIGN CHANGE TO THE HORN MOUNTING PLATE IN JANUARY 2006 AND THEN MAJOR CHANGES TO THE HORN MOUNTING PLATE, AIRBAG MODULE AND CLOCKSPRING JUMPER WIRE DESIGNS IN JUNE 2006 FOR THE MY2007 VEHICLES.THIS PRELIMINARY EVALUATION IS UPGRADED TO AN ENGINEERING ANALYSIS (EA10-001) TO INCLUDE MY2004-2006 F-150 VEHICLES AND TO FURTHER EVALUATE THE CONDITION.
PE08001 · Loss Of Brake POWER-ASSIST
Opened Jan 8, 2008 · Closed May 9, 2008
Status: closed (inferred from source dates) · Service Brakes, Hydraulic:power Assist; Service Brakes, Hydraulic:power Assist:vacuum; Service Brakes, Hydraulic:power Assist:vacuum:hoses, Lines/piping, And Fittings
BY LETTER DATED MAY 5, 2008, FORD MOTOR COMPANY (FORD) NOTIFIED THE AGENCY THAT IT WILL CONDUCT A SAFETY RECALL (NHTSA RECALL NUMBER 08V-208) TO ADDRESS A MANUFACTURING DEFECT IN APPROXIMATELY 605,684 MODEL YEAR (MY) 2005 AND 2006 FORD F-150 AND LINCOLN MARK LT VEHICLES ORIGINALLY EQUIPPED WITH THE 5.4L DISPLACEMENT, 3-VALVE PER CYLINDER, V-8 ENGINE.THE RECALLED VEHICLES WERE BUILT FROM JULY 18, 2004 THROUGH MAY 31, 2006 AT THE DEARBORN TRUCK PLANT; FROM MAY 4, 2004 THROUGH MAY 31, 2006 AT THE KANSAS CITY ASSEMBLY PLANT; AND FROM APRIL 19, 2004 THROUGH MAY 31, 2006 AT THE NORFOLK TRUCK PLANT.THE VEHICLES WERE MANUFACTURED WITH THE SAME DEFECTIVE BRAKE BOOSTER VACUUM SUPPLY HOSE ASSEMBLY UNIQUE TO THE 5.4L V-8 ENGINE.FORD F-150 VEHICLES EQUIPPED WITH OPTIONALLY AVAILABLE 4.2L V6 AND 4.6L V-8 ENGINES ARE NOT INCLUDED IN THIS RECALL ACTION BECAUSE THEY UTILIZE A DIFFERENT, ONE-PIECE BRAKE BOOSTER VACUUM SUPPLY HOSE ASSEMBLY THAT DOES NOT EXHIBIT AN APPARENT DEFECT TREND. THE RECALLED VEHICLES UTILIZE A TWO-PIECE BRAKE BOOSTER VACUUM SUPPLY HOSE ASSEMBLY COMPRISED OF A STANDPIPE ASSEMBLY AND VACUUM HOSE.THE STANDPIPE ASSEMBLY ATTACHES TO A FITTING ON THE ENGINE AIR INTAKE MANIFOLD UTILIZING A FLEXIBLE RUBBER HOSE AND PLASTIC ELBOW.THE VACUUM HOSE ATTACHES TO THE OPPOSITE END OF THE STANDPIPE ASSEMBLY AND CONNECTS TO A CHECK VALVE FITTING AT THE BRAKE BOOSTER ASSEMBLY.ACCORDING TO FORD, THE PORTION OF THE BRAKE BOOSTER VACUUM SUPPLY HOSE ASSEMBLY ATTACHED TO THE INTAKE MANIFOLD MAY SWELL OVER TIME AND LOSE RETENTION FORCE, WHICH MAY ALLOW THE HOSE TO BECOME DETACHED FROM THE INTAKE MANIFOLD.SHOULD THE BRAKE BOOSTER VACUUM SUPPLY HOSE ASSEMBLY BE DISRUPTED, APPLICATION OF THE BRAKE PEDAL MAY DEPLETE THE VACUUM RESERVE AND CONSEQUENTLY RESULT IN LOSS OF BRAKE POWER-ASSIST. TO CORRECT THE SAFETY DEFECT, FORD WILL INSTALL AN IMPROVED DESIGN BRAKE BOOSTER VACUUM SUPPLY HOSE ASSEMBLY THAT UTILIZES A HOSE CLAMP AT THE INTAKE MANIFOLD ATTACHMENT. THIS REMEDY WILL BE PROVIDED FREE OF CHARGE FOR ALL RECALLED VEHICLES.LATER PRODUCTION FORD F-150 AND LINCOLN MARK LT VEHICLES BUILT AFTER MAY 2006 WERE MANUFACTURED WITH A HOSE CLAMP AT THE BRAKE BOOSTER VACUUM SUPPLY HOSE/INTAKE MANIFOLD ATTACHMENT AND ARE NOT AFFECTED. TO DATE, THE OFFICE OF DEFECTS INVESTIGATION (ODI) IS AWARE OF 324 NON-DUPLICATIVE COMPLAINTS AND 14 NON-INJURY CRASHES RELATED TO THE ALLEGED DEFECT IN THE SUBJECT VEHICLES.IN ADDITION, ODI IS AWARE OF 4,465 SUBJECT VEHICLES THAT EXPERIENCED ONE OR MORE WARRANTY CLAIMS TO REPAIR OR REPLACE THE SUBJECT BRAKE BOOSTER VACUUM SUPPLY HOSE ASSEMBLY. THE ACTION TAKEN BY FORD IS SUFFICIENT TO RESOLVE THE ISSUES RAISED BY THIS INVESTIGATION.ACCORDINGLY, THIS INVESTIGATION IS CLOSED.
Additional source detail variants (3)
Service Brakes, Hydraulic:power Assist
BY LETTER DATED MAY 5, 2008, FORD MOTOR COMPANY (FORD) NOTIFIED THE AGENCY THAT IT WILL CONDUCT A SAFETY RECALL (NHTSA RECALL NUMBER 08V-208) TO ADDRESS A MANUFACTURING DEFECT IN APPROXIMATELY 605,684 MODEL YEAR (MY) 2005 AND 2006 FORD F-150 AND LINCOLN MARK LT VEHICLES ORIGINALLY EQUIPPED WITH THE 5.4L DISPLACEMENT, 3-VALVE PER CYLINDER, V-8 ENGINE.THE RECALLED VEHICLES WERE BUILT FROM JULY 18, 2004 THROUGH MAY 31, 2006 AT THE DEARBORN TRUCK PLANT; FROM MAY 4, 2004 THROUGH MAY 31, 2006 AT THE KANSAS CITY ASSEMBLY PLANT; AND FROM APRIL 19, 2004 THROUGH MAY 31, 2006 AT THE NORFOLK TRUCK PLANT.THE VEHICLES WERE MANUFACTURED WITH THE SAME DEFECTIVE BRAKE BOOSTER VACUUM SUPPLY HOSE ASSEMBLY UNIQUE TO THE 5.4L V-8 ENGINE.FORD F-150 VEHICLES EQUIPPED WITH OPTIONALLY AVAILABLE 4.2L V6 AND 4.6L V-8 ENGINES ARE NOT INCLUDED IN THIS RECALL ACTION BECAUSE THEY UTILIZE A DIFFERENT, ONE-PIECE BRAKE BOOSTER VACUUM SUPPLY HOSE ASSEMBLY THAT DOES NOT EXHIBIT AN APPARENT DEFECT TREND. THE RECALLED VEHICLES UTILIZE A TWO-PIECE BRAKE BOOSTER VACUUM SUPPLY HOSE ASSEMBLY COMPRISED OF A STANDPIPE ASSEMBLY AND VACUUM HOSE.THE STANDPIPE ASSEMBLY ATTACHES TO A FITTING ON THE ENGINE AIR INTAKE MANIFOLD UTILIZING A FLEXIBLE RUBBER HOSE AND PLASTIC ELBOW.THE VACUUM HOSE ATTACHES TO THE OPPOSITE END OF THE STANDPIPE ASSEMBLY AND CONNECTS TO A CHECK VALVE FITTING AT THE BRAKE BOOSTER ASSEMBLY.ACCORDING TO FORD, THE PORTION OF THE BRAKE BOOSTER VACUUM SUPPLY HOSE ASSEMBLY ATTACHED TO THE INTAKE MANIFOLD MAY SWELL OVER TIME AND LOSE RETENTION FORCE, WHICH MAY ALLOW THE HOSE TO BECOME DETACHED FROM THE INTAKE MANIFOLD.SHOULD THE BRAKE BOOSTER VACUUM SUPPLY HOSE ASSEMBLY BE DISRUPTED, APPLICATION OF THE BRAKE PEDAL MAY DEPLETE THE VACUUM RESERVE AND CONSEQUENTLY RESULT IN LOSS OF BRAKE POWER-ASSIST. TO CORRECT THE SAFETY DEFECT, FORD WILL INSTALL AN IMPROVED DESIGN BRAKE BOOSTER VACUUM SUPPLY HOSE ASSEMBLY THAT UTILIZES A HOSE CLAMP AT THE INTAKE MANIFOLD ATTACHMENT. THIS REMEDY WILL BE PROVIDED FREE OF CHARGE FOR ALL RECALLED VEHICLES.LATER PRODUCTION FORD F-150 AND LINCOLN MARK LT VEHICLES BUILT AFTER MAY 2006 WERE MANUFACTURED WITH A HOSE CLAMP AT THE BRAKE BOOSTER VACUUM SUPPLY HOSE/INTAKE MANIFOLD ATTACHMENT AND ARE NOT AFFECTED. TO DATE, THE OFFICE OF DEFECTS INVESTIGATION (ODI) IS AWARE OF 324 NON-DUPLICATIVE COMPLAINTS AND 14 NON-INJURY CRASHES RELATED TO THE ALLEGED DEFECT IN THE SUBJECT VEHICLES.IN ADDITION, ODI IS AWARE OF 4,465 SUBJECT VEHICLES THAT EXPERIENCED ONE OR MORE WARRANTY CLAIMS TO REPAIR OR REPLACE THE SUBJECT BRAKE BOOSTER VACUUM SUPPLY HOSE ASSEMBLY. THE ACTION TAKEN BY FORD IS SUFFICIENT TO RESOLVE THE ISSUES RAISED BY THIS INVESTIGATION.ACCORDINGLY, THIS INVESTIGATION IS CLOSED.
Service Brakes, Hydraulic:power Assist:vacuum
BY LETTER DATED MAY 5, 2008, FORD MOTOR COMPANY (FORD) NOTIFIED THE AGENCY THAT IT WILL CONDUCT A SAFETY RECALL (NHTSA RECALL NUMBER 08V-208) TO ADDRESS A MANUFACTURING DEFECT IN APPROXIMATELY 605,684 MODEL YEAR (MY) 2005 AND 2006 FORD F-150 AND LINCOLN MARK LT VEHICLES ORIGINALLY EQUIPPED WITH THE 5.4L DISPLACEMENT, 3-VALVE PER CYLINDER, V-8 ENGINE.THE RECALLED VEHICLES WERE BUILT FROM JULY 18, 2004 THROUGH MAY 31, 2006 AT THE DEARBORN TRUCK PLANT; FROM MAY 4, 2004 THROUGH MAY 31, 2006 AT THE KANSAS CITY ASSEMBLY PLANT; AND FROM APRIL 19, 2004 THROUGH MAY 31, 2006 AT THE NORFOLK TRUCK PLANT.THE VEHICLES WERE MANUFACTURED WITH THE SAME DEFECTIVE BRAKE BOOSTER VACUUM SUPPLY HOSE ASSEMBLY UNIQUE TO THE 5.4L V-8 ENGINE.FORD F-150 VEHICLES EQUIPPED WITH OPTIONALLY AVAILABLE 4.2L V6 AND 4.6L V-8 ENGINES ARE NOT INCLUDED IN THIS RECALL ACTION BECAUSE THEY UTILIZE A DIFFERENT, ONE-PIECE BRAKE BOOSTER VACUUM SUPPLY HOSE ASSEMBLY THAT DOES NOT EXHIBIT AN APPARENT DEFECT TREND. THE RECALLED VEHICLES UTILIZE A TWO-PIECE BRAKE BOOSTER VACUUM SUPPLY HOSE ASSEMBLY COMPRISED OF A STANDPIPE ASSEMBLY AND VACUUM HOSE.THE STANDPIPE ASSEMBLY ATTACHES TO A FITTING ON THE ENGINE AIR INTAKE MANIFOLD UTILIZING A FLEXIBLE RUBBER HOSE AND PLASTIC ELBOW.THE VACUUM HOSE ATTACHES TO THE OPPOSITE END OF THE STANDPIPE ASSEMBLY AND CONNECTS TO A CHECK VALVE FITTING AT THE BRAKE BOOSTER ASSEMBLY.ACCORDING TO FORD, THE PORTION OF THE BRAKE BOOSTER VACUUM SUPPLY HOSE ASSEMBLY ATTACHED TO THE INTAKE MANIFOLD MAY SWELL OVER TIME AND LOSE RETENTION FORCE, WHICH MAY ALLOW THE HOSE TO BECOME DETACHED FROM THE INTAKE MANIFOLD.SHOULD THE BRAKE BOOSTER VACUUM SUPPLY HOSE ASSEMBLY BE DISRUPTED, APPLICATION OF THE BRAKE PEDAL MAY DEPLETE THE VACUUM RESERVE AND CONSEQUENTLY RESULT IN LOSS OF BRAKE POWER-ASSIST. TO CORRECT THE SAFETY DEFECT, FORD WILL INSTALL AN IMPROVED DESIGN BRAKE BOOSTER VACUUM SUPPLY HOSE ASSEMBLY THAT UTILIZES A HOSE CLAMP AT THE INTAKE MANIFOLD ATTACHMENT. THIS REMEDY WILL BE PROVIDED FREE OF CHARGE FOR ALL RECALLED VEHICLES.LATER PRODUCTION FORD F-150 AND LINCOLN MARK LT VEHICLES BUILT AFTER MAY 2006 WERE MANUFACTURED WITH A HOSE CLAMP AT THE BRAKE BOOSTER VACUUM SUPPLY HOSE/INTAKE MANIFOLD ATTACHMENT AND ARE NOT AFFECTED. TO DATE, THE OFFICE OF DEFECTS INVESTIGATION (ODI) IS AWARE OF 324 NON-DUPLICATIVE COMPLAINTS AND 14 NON-INJURY CRASHES RELATED TO THE ALLEGED DEFECT IN THE SUBJECT VEHICLES.IN ADDITION, ODI IS AWARE OF 4,465 SUBJECT VEHICLES THAT EXPERIENCED ONE OR MORE WARRANTY CLAIMS TO REPAIR OR REPLACE THE SUBJECT BRAKE BOOSTER VACUUM SUPPLY HOSE ASSEMBLY. THE ACTION TAKEN BY FORD IS SUFFICIENT TO RESOLVE THE ISSUES RAISED BY THIS INVESTIGATION.ACCORDINGLY, THIS INVESTIGATION IS CLOSED.
Service Brakes, Hydraulic:power Assist:vacuum:hoses, Lines/piping, And Fittings
BY LETTER DATED MAY 5, 2008, FORD MOTOR COMPANY (FORD) NOTIFIED THE AGENCY THAT IT WILL CONDUCT A SAFETY RECALL (NHTSA RECALL NUMBER 08V-208) TO ADDRESS A MANUFACTURING DEFECT IN APPROXIMATELY 605,684 MODEL YEAR (MY) 2005 AND 2006 FORD F-150 AND LINCOLN MARK LT VEHICLES ORIGINALLY EQUIPPED WITH THE 5.4L DISPLACEMENT, 3-VALVE PER CYLINDER, V-8 ENGINE.THE RECALLED VEHICLES WERE BUILT FROM JULY 18, 2004 THROUGH MAY 31, 2006 AT THE DEARBORN TRUCK PLANT; FROM MAY 4, 2004 THROUGH MAY 31, 2006 AT THE KANSAS CITY ASSEMBLY PLANT; AND FROM APRIL 19, 2004 THROUGH MAY 31, 2006 AT THE NORFOLK TRUCK PLANT.THE VEHICLES WERE MANUFACTURED WITH THE SAME DEFECTIVE BRAKE BOOSTER VACUUM SUPPLY HOSE ASSEMBLY UNIQUE TO THE 5.4L V-8 ENGINE.FORD F-150 VEHICLES EQUIPPED WITH OPTIONALLY AVAILABLE 4.2L V6 AND 4.6L V-8 ENGINES ARE NOT INCLUDED IN THIS RECALL ACTION BECAUSE THEY UTILIZE A DIFFERENT, ONE-PIECE BRAKE BOOSTER VACUUM SUPPLY HOSE ASSEMBLY THAT DOES NOT EXHIBIT AN APPARENT DEFECT TREND. THE RECALLED VEHICLES UTILIZE A TWO-PIECE BRAKE BOOSTER VACUUM SUPPLY HOSE ASSEMBLY COMPRISED OF A STANDPIPE ASSEMBLY AND VACUUM HOSE.THE STANDPIPE ASSEMBLY ATTACHES TO A FITTING ON THE ENGINE AIR INTAKE MANIFOLD UTILIZING A FLEXIBLE RUBBER HOSE AND PLASTIC ELBOW.THE VACUUM HOSE ATTACHES TO THE OPPOSITE END OF THE STANDPIPE ASSEMBLY AND CONNECTS TO A CHECK VALVE FITTING AT THE BRAKE BOOSTER ASSEMBLY.ACCORDING TO FORD, THE PORTION OF THE BRAKE BOOSTER VACUUM SUPPLY HOSE ASSEMBLY ATTACHED TO THE INTAKE MANIFOLD MAY SWELL OVER TIME AND LOSE RETENTION FORCE, WHICH MAY ALLOW THE HOSE TO BECOME DETACHED FROM THE INTAKE MANIFOLD.SHOULD THE BRAKE BOOSTER VACUUM SUPPLY HOSE ASSEMBLY BE DISRUPTED, APPLICATION OF THE BRAKE PEDAL MAY DEPLETE THE VACUUM RESERVE AND CONSEQUENTLY RESULT IN LOSS OF BRAKE POWER-ASSIST. TO CORRECT THE SAFETY DEFECT, FORD WILL INSTALL AN IMPROVED DESIGN BRAKE BOOSTER VACUUM SUPPLY HOSE ASSEMBLY THAT UTILIZES A HOSE CLAMP AT THE INTAKE MANIFOLD ATTACHMENT. THIS REMEDY WILL BE PROVIDED FREE OF CHARGE FOR ALL RECALLED VEHICLES.LATER PRODUCTION FORD F-150 AND LINCOLN MARK LT VEHICLES BUILT AFTER MAY 2006 WERE MANUFACTURED WITH A HOSE CLAMP AT THE BRAKE BOOSTER VACUUM SUPPLY HOSE/INTAKE MANIFOLD ATTACHMENT AND ARE NOT AFFECTED. TO DATE, THE OFFICE OF DEFECTS INVESTIGATION (ODI) IS AWARE OF 324 NON-DUPLICATIVE COMPLAINTS AND 14 NON-INJURY CRASHES RELATED TO THE ALLEGED DEFECT IN THE SUBJECT VEHICLES.IN ADDITION, ODI IS AWARE OF 4,465 SUBJECT VEHICLES THAT EXPERIENCED ONE OR MORE WARRANTY CLAIMS TO REPAIR OR REPLACE THE SUBJECT BRAKE BOOSTER VACUUM SUPPLY HOSE ASSEMBLY. THE ACTION TAKEN BY FORD IS SUFFICIENT TO RESOLVE THE ISSUES RAISED BY THIS INVESTIGATION.ACCORDINGLY, THIS INVESTIGATION IS CLOSED.
Illustration