← New search

2005 Ford F-150

Owner reports · Recalls · Investigations

Similar to other model years

Owner complaints for the 2005 Ford F-150 do not stand out strongly from the model-year median of 676.

About this comparison →

When problems were reported

Mileage at the reported incident

973 reports with mileage · 139 unknown

NHTSA’s mileage field refers to the reported incident, not necessarily the filing date. This shows report counts, not the likelihood of a failure.

What to inspect

Issues worth paying extra attention to based on owner reports.

  • Visibility. Review the 260 owner reports in this category and discuss these concerns during a pre-purchase inspection. Read reports →
  • Engine. Review the 117 owner reports in this category and discuss these concerns during a pre-purchase inspection. Read reports →
  • Power Train. Review the 112 owner reports in this category and discuss these concerns during a pre-purchase inspection. Read reports →

NHTSA owner reports · September 18, 2026 snapshot.

50 crash reports29 fire reports48 injury reports

Power Train complaints

112 reports
Clear category filter
53,900 miles · Mar 21, 2009
Engine And Engine CoolingPower Train

WHILE DRIVING, THE VACUUM SOLENOID FOR THE 4 WHEEL DRIVE TRIES TO ENGAGE THE 4 WHEEL DRIVE - EVEN AT HIGHWAY SPEEDS- RESULTING IN A HORRIBLE SOUND. THE SOUND WAS "LIKE I HAD RUN OVER A SHOPPING CART OR HIT SOMETHING IN THE ROAD AND WAS DRAGGING IT UNDER THE TRUCK". THIS HAPPENED 5 TIMES IN TWO DAYS IN LESS THAN 30 MILES OF TOT…

Read full complaint

WHILE DRIVING, THE VACUUM SOLENOID FOR THE 4 WHEEL DRIVE TRIES TO ENGAGE THE 4 WHEEL DRIVE - EVEN AT HIGHWAY SPEEDS- RESULTING IN A HORRIBLE SOUND. THE SOUND WAS "LIKE I HAD RUN OVER A SHOPPING CART OR HIT SOMETHING IN THE ROAD AND WAS DRAGGING IT UNDER THE TRUCK". THIS HAPPENED 5 TIMES IN TWO DAYS IN LESS THAN 30 MILES OF TOTAL DRIVING. THE NOISE IS SO LOUD AND ALARMING THAT IT MADE ME IMMEDIATELY APPLY THE BRAKES AND PULL TO THE SIDE OF THE ROAD BECAUSE I THOUGHT I HAD HIT SOMETHING/SOMEONE. AT FIRST I WONDERED IF MY MUFFLER OR DRIVE SHAFT OR SOME OTHER PART HAD FALLEN OFF OF THE TRUCK. THIS "FALSE ENGAGEMENT" OF THE 4 WHEEL DRIVE HAPPENS WITHOUT ANY WARNING IN ALL KIDS OF DRIVING CONDITIONS (SLOW, FAST, BREAKING OR ACCELERATING). A NEW, REDESIGNED (NOW HAS A COVER ON IT TO KEEP MOISTURE OUT- WHICH WAS CAUSING THE FAILURE) VACUUM SOLENOID WAS INSTALLED ON TRUCK - A $27.00 PART. DEALERSHIP KEPT OLD PART. TECH. AT DEALER TOLD ME THAT THIS PART WILL GO BAD AT SOME POINT AND NEED REPLACING ON ALL THE TRUCKS WITH THE PART. HE SAID "NOT IF BUT WHEN". FORD KNEW ABOUT THE PROBLEM - HENCE THE REDESIGNED PART. FORD HAS NOT NOTIFIED OWNERS OF THIS PART AND IT'S IMPENDING FAILURE. *TR

NHTSA ODI #10262623

50,000 miles · Jan 19, 2009
Electrical SystemPower TrainService Brakes, Hydraulic

I BOUGHT THIS TRUCK WITH 48,000 MILES ON IT. IT HAD A BAD SHAKE IN THE REAR AREA. ALSO A BAD BRAKE SHIMMY. TOOK TO FORD DEALERSHIP I BOUGHT IT. COULDN'T FIND ANYTHING WRONG. TOLD NORMAL! I WORKED IN THE SERVICE DEPT OF A FORD DEALERSHIP I KNOW NORMAL. 53,000 OR SO MILES BAD CLUNKING FROM TRANSFER AREA WOULDN'T GO INTO 4 WHEEL DR…

Read full complaint

I BOUGHT THIS TRUCK WITH 48,000 MILES ON IT. IT HAD A BAD SHAKE IN THE REAR AREA. ALSO A BAD BRAKE SHIMMY. TOOK TO FORD DEALERSHIP I BOUGHT IT. COULDN'T FIND ANYTHING WRONG. TOLD NORMAL! I WORKED IN THE SERVICE DEPT OF A FORD DEALERSHIP I KNOW NORMAL. 53,000 OR SO MILES BAD CLUNKING FROM TRANSFER AREA WOULDN'T GO INTO 4 WHEEL DRIVE 1/2 THE TIME TOOK TO FORD, TOLD NOTHING WRONG AGAIN. 72,000 MILES TRANSMISSION GOES OUT. TOLD NOTHING COULD BE DONE, OUT BY 2000 MILES. I WAS A SERVICE MANAGER FOR A FORD DEALERSHIP THEY COULD DO A SUPPLEMENT ON THE WARRANTY. I ASKED FOR 1/2 OF COST TOLD NO. EVEN AFTER DOCUMENTATION OF ALL THE SERVICES AND COMPLAINTS TOLD TO BAD SO SAD. THIS TRUCK HAS HAD TRANSMISSION TROUBLES, 4 WHEEL DRIVE TROUBLE, THE POWER WINDOW SWITCH FELL APART IN THE DOOR AND A BAD BRAKE SHIMMY EVEN AFTER I HAD A 4 WHEEL BRAKE JOB DONE, ITS STILL THERE. NO HELP FROM FORD AT ALL! *TR

NHTSA ODI #10255574

35,000 miles · Jan 14, 2009
Power Train

WHILE DRIVING ON HIGHWAY @ 60MPH, MY 4 WHEEL DRIVE ACTIVATED WITHOUT MY TOUCHING THE DASH CONTROL. THE FRONT AXLE MADE TERRIBLE GRINDING NOISES AND THE VEHICLE SLOWED DRAMATICALLY. DEALER TOLD ME IT WAS A VACUUM LINE AND FORD REPLACED UNDER WARRANTY. *TR

NHTSA ODI #10254983

46,475 miles · Dec 10, 2008
Engine And Engine CoolingPower Train

5.4L, SUPERCREW-- ENGINE WAS REPLACED BY FORD AT 38,000 MILES (AFTER COMPLAINT TO FORD CUST SVC) DUE TO INJECTOR FAILURE AND CYLINDER HYDRA-LOCK. NOW AT 46,000 MILES, COMPLETE TRANSMISSION FAILURE. ONLY USED FOR DAILY DRIVER, NO TOWING, NEVER OFF-ROAD. TRANSMISSION FAILED ON INITIAL START ON 60 DEGREE MORNING, NO PRE-FAILURE …

Read full complaint

5.4L, SUPERCREW-- ENGINE WAS REPLACED BY FORD AT 38,000 MILES (AFTER COMPLAINT TO FORD CUST SVC) DUE TO INJECTOR FAILURE AND CYLINDER HYDRA-LOCK. NOW AT 46,000 MILES, COMPLETE TRANSMISSION FAILURE. ONLY USED FOR DAILY DRIVER, NO TOWING, NEVER OFF-ROAD. TRANSMISSION FAILED ON INITIAL START ON 60 DEGREE MORNING, NO PRE-FAILURE INDICATORS. PAID $2800 FOR TRANSMISSION REBUILD. I HAVE NOTICED A FAIRLY LARGE NUMBER OF PROBLEMS REPORTED ON SUB-STANDARD FACTORY TRANSMISSION AND ENGINE PARTS ON FORD TRUCKS. *TR

NHTSA ODI #10251265

30,000 miles · May 5, 2008
Power Train

HAVING INTERMITTENT EXTREMELY VIOLENT SHAKING ISSUES WITH OUR '05 FORD F-150. IT ONLY HAPPENS NOW AND THEN, BUT WHEN IT DOES, YOU CANNOT EVEN STEER TO GET THE TRUCK OFF THE ROAD. IT HAS NO RELATION TO SPEED OR BRAKING. WENT TO THE DEALER, THEY SAID THEY FOUND THE PROBLEM AND REPLACED ONE OF THE ARMS, BUT IT HAPPENED AGAIN. I…

Read full complaint

HAVING INTERMITTENT EXTREMELY VIOLENT SHAKING ISSUES WITH OUR '05 FORD F-150. IT ONLY HAPPENS NOW AND THEN, BUT WHEN IT DOES, YOU CANNOT EVEN STEER TO GET THE TRUCK OFF THE ROAD. IT HAS NO RELATION TO SPEED OR BRAKING. WENT TO THE DEALER, THEY SAID THEY FOUND THE PROBLEM AND REPLACED ONE OF THE ARMS, BUT IT HAPPENED AGAIN. I NOTICED THERE ARE HUNDREDS OF SIMILAR COMPLAINTS WITH ALL YEARS AND NUMEROUS MAKES OF THE FORD TRUCK POSTED ONLINE UNDER "VIOLENT SHAKING". IT SEEMS THAT THIS IS A SERIOUS PROBLEM THAT FORD IS NOT LOOKING INTO, AND IT WILL CAUSE A DEATH, OR MANY IF IT IS NOT ADDRESSED. *TR

NHTSA ODI #10226683

30,000 miles · Apr 29, 2008
Power Train

TL*THE CONTACT OWNS A 2005 FORD F-150. WHILE DRIVING BETWEEN 65-70 MPH, THE ENTIRE VEHICLE VIBRATES. THE DEALER IS CURRENTLY INSPECTING THE VEHICLE. THE CONTACT STATED THAT THE VEHICLE IS UNSAFE TO DRIVE. HE BELIEVED THAT THE DRIVELINE WAS THE CAUSE OF THE FAILURE. THE FAILURE MILEAGE WAS 30,000.

NHTSA ODI #10226005

57,000 miles · Feb 20, 2008
Power Train

FORD F-150 SUPER CREW WITH 57,000 MILES WILL NOT ENGAGE IN OVERDRIVE. WHILE DRIVING, THE TRANSMISSION COMPLETELY SLIPPED OUT OF GEAR. AFTER PULLING OFF THE ROAD AND TESTING IT IN REVERSE AND DRIVE, I WAS ABLE TO RESUME BUT AS SOON AS THE TRANSMISSION REACHED OVERDRIVE IT DISENGAGED COMPLETELY. DEALER CLAIMS A PIN WAS BROKEN T…

Read full complaint

FORD F-150 SUPER CREW WITH 57,000 MILES WILL NOT ENGAGE IN OVERDRIVE. WHILE DRIVING, THE TRANSMISSION COMPLETELY SLIPPED OUT OF GEAR. AFTER PULLING OFF THE ROAD AND TESTING IT IN REVERSE AND DRIVE, I WAS ABLE TO RESUME BUT AS SOON AS THE TRANSMISSION REACHED OVERDRIVE IT DISENGAGED COMPLETELY. DEALER CLAIMS A PIN WAS BROKEN THAT LOCKS THE TRANSMISSION IN OVERDRIVE. *TR

NHTSA ODI #10218615

45,000 miles · Jan 28, 2008
Power TrainService Brakes, Hydraulic

BRAKE PROBLEMS SEVERAL TIMES NOW I HAVE HAD TO HAVE CALIPERS, ROTORS, ETC REPLACED. NOW MY REAR END SEEMS TO BE SLIPPING GOING AROUND CORNERS. *TR

NHTSA ODI #10216329

8 miles · Jan 11, 2008
Power Train

TL*THE CONTACT OWNS A 2005 FORD F150. SINCE THE VEHICLE WAS PURCHASED, THE TRANSMISSION EXPERIENCED IRREGULARITIES WHILE SHIFTING. THE VEHICLE WOULD SHIFT IN AND OUT OF GEAR. THE CONTACT HEARD A NOISE WHEN THE VEHICLE SHIFTED INTO OVERDRIVE. THE VEHICLE WAS TAKEN BACK TO THE DEALER AT 23,400 MILES AND THEY STATED THAT NOTHIN…

Read full complaint

TL*THE CONTACT OWNS A 2005 FORD F150. SINCE THE VEHICLE WAS PURCHASED, THE TRANSMISSION EXPERIENCED IRREGULARITIES WHILE SHIFTING. THE VEHICLE WOULD SHIFT IN AND OUT OF GEAR. THE CONTACT HEARD A NOISE WHEN THE VEHICLE SHIFTED INTO OVERDRIVE. THE VEHICLE WAS TAKEN BACK TO THE DEALER AT 23,400 MILES AND THEY STATED THAT NOTHING WAS WRONG WITH THE VEHICLE. ROCKS WERE REMOVED FROM THE EXHAUST SHIELD. THE TECHNICIAN TEST DROVE THE VEHICLE AND STATED THAT THE NOISE WAS NORMAL. WHILE DRIVING AT 55 MPH, THE VEHICLE BEGAN JERKING AND THE TRANSMISSION FAILED WITHOUT WARNING. THE DEALER STATED THAT SOMETHING BECAME LOOSE WITHIN THE TRANSMISSION AND IT NEEDED TO BE REPLACED. FORD STATED THAT THE CONTACT WOULD HAVE TO PAY OUT OF POCKET BECAUSE THE VEHICLE WAS NOT UNDER WARRANTY. THE PURCHASE DATE WAS UNKNOWN. THE CURRENT MILEAGE WAS 67,000 AND FAILURE MILEAGE WAS 8.

NHTSA ODI #10214496

9,000 miles · May 14, 2007
Power Train

TL*THE CONTACT OWNS A 2005 FORD F-150. WHILE DRIVING 40 MPH HE STATED THAT THE GEAR SHIFT INDICATOR DISENGAGED WHEN HE CAME TO A STOP, WHICH CAUSED THE VEHICLE TO JERK HARD. THERE WAS ALSO AN INCREASE IN THE RPM, WHICH CAUSED THE VEHICLE GEAR SHIFT INDICTOR TO ENGAGE WITHOUT WARNING. THE CONTACT STATED THE TRANSMISSIONS SLI…

Read full complaint

TL*THE CONTACT OWNS A 2005 FORD F-150. WHILE DRIVING 40 MPH HE STATED THAT THE GEAR SHIFT INDICATOR DISENGAGED WHEN HE CAME TO A STOP, WHICH CAUSED THE VEHICLE TO JERK HARD. THERE WAS ALSO AN INCREASE IN THE RPM, WHICH CAUSED THE VEHICLE GEAR SHIFT INDICTOR TO ENGAGE WITHOUT WARNING. THE CONTACT STATED THE TRANSMISSIONS SLIPPED OUT OF GEAR WOULD NOT ACCELERATE. THE FAILURE MILEAGE WAS 9,000 AND THE CURRENT MILEAGE WAS 19,000.

NHTSA ODI #10190709

Official recalls

3

11V107000 · Air Bags:frontal:driver Side:inflator Module

Feb 23, 2011

FORD IS RECALLING CERTAIN MODEL YEAR 2004-2006 F-150 PICK UP TRUCKS AS WELL AS CERTAIN MODEL YEAR 2006 LINCOLN MARK LT VEHICLES. IF THE CLOCKSPRING JUMPER WIRE COMES IN CONTACT WITH THE DRIVER SIDE FRONTAL AIR BAG LOWER HORN PLATE, THE WIRE INSULATION MAY BECOME CHAFED, CREATING A POTENTIAL FOR A SHORT CIRCUIT. IF THIS OCCURS THE AIR BAG WARNING LAMP MAY ILLUMINATE INDICATING THAT SERVICE IS REQUIRED.

Consequence & remedy

Consequence: THE DRIVER SIDE FRONTAL AIR BAG COULD INADVERTENTLY DEPLOY INCREASING THE RISK OF INJURY OR LOSS OF VEHICLE CONTROL IF OCCURRING WHILE IN MOTION.

Remedy: FORD WILL NOTIFY OWNERS AND INSTRUCT THEM TO TAKE THEIR VEHICLES TO A FORD OR LINCOLN/MERCURY DEALER TO HAVE A NEW CLOCKSPRING JUMPER WIRE INSTALLED THAT INCORPORATES A PROTECTIVE MESH COVER. REPAIRS WILL BE PERFORMED FREE OF CHARGE. THIS SAFETY RECALL BEGAN ON SOME VEHICLES IN MARCH 2011. THE RECALL CAMPAIGN ON THE EXPANDED POPULATION IS EXPECTED TO BEGIN ON OR ABOUT MAY 9, 2011. OWNERS MAY CONTACT THE FORD MOTOR COMPANY CUSTOMER RELATIONSHIP CENTER AT 1-866-436-7332.

08V208000 · Service Brakes, Hydraulic:power Assist:vacuum:hoses, Lines/piping, And Fittings

May 7, 2008

FORD IS RECALLING 605,684 MY 2005-2006 F-150 AND LINCOLN MARK LT VEHICLES EQUIPPED WITH 5.4L 3-VALVE ENGINES. THE BRAKE BOOSTER VACUUM SUPPLY HOSE ATTACHED TO THE INTAKE MANIFOLD FITTING MAY SWELL OVER TIME AND LOSE RETENTION FORCE. THIS CONDITION COULD ALLOW THE HOSE TO BECOME DETACHED FROM THE FITTING DURING AN INTAKE MANIFOLD BACKFIRE. SHOULD THE HOSE DETACH FROM THE INTAKE MANIFOLD, SEVERAL BRAKE APPLICATIONS WITH POWER ASSIST WILL BE AVAILABLE BEFORE THE VACUUM RESERVE IS DEPLETED.

Consequence & remedy

Consequence: ONCE THE BRAKE BOOSTER VACUUM RESERVE IS DEPLETED, THE DRIVER WILL HAVE FOUNDATION BRAKE FUNCTION, BUT WITH INCREASED BRAKE PEDAL EFFORT. REDUCED VEHICLE BRAKING COULD LEAD TO A CRASH.

Remedy: DEALERS WILL REPLACE A RUBBER HOSE ON THE BRAKE BOOSTER VACUUM SUPPLY TUBE ASSEMBLY. THE RECALL BEGAN ON JUNE 27, 2008. OWNERS MAY CONTACT FORD AT 1-800-392-3673.

06V033000 · Interior Lighting

Feb 6, 2006

CERTAIN PICKUP TRUCKS FAIL TO COMPLY WITH EITHER THE REQUIREMENTS OF FEDERAL MOTOR VEHICLE SAFETY STANDARD (FMVSS) NO. 105, 'HYDRAULIC AND ELECTRIC BRAKE SYSTEMS' OR FMVSS NO. 135, 'PASSENGER CAR BRAKE SYSTEMS.' THESE VEHICLES WERE BUILT WITH A SOFTWARE ERROR IN THE INSTRUMENT CLUSTER.

Consequence & remedy

Consequence: THIS ERROR COULD PREVENT THE ANTILOCK BRAKE SYSTEM (ABS) WARNING LIGHT FROM ILLUMINATING IF THE ABS MODULE EVER BECAME INOPERATIVE.

Remedy: DEALERS WILL RECALIBRATE THE INSTRUMENT CLUSTER IN THESE VEHICLES. THE RECALL BEGAN ON FEBRUARY 27, 2006. OWNERS MAY CONTACT FORD AT 1-800-392-3673.

Model-level recall history does not show whether a particular VIN is affected or has received a repair. Check a VIN with NHTSA ↗

NHTSA investigations

3

EA10001 · Inadvertent Airbag Deployment

Opened Jan 13, 2010 · Closed Apr 25, 2011

Status: closed (inferred from source dates) · Air Bags; Air Bags:frontal; Air Bags:frontal:driver Side:inflator Module; Air Bags:frontal:sensor/control MODULE-INACTIVE

ODI opened this investigation based on reports of inadvertent airbag deployment.Data provided by Ford indicated that the airbag clockspring jumper wire, which is situated inside the steering wheel assembly, was installed in a manner that would allow it to rub (abrade) against a sharp metal edge on the nearby horn plate.Because the horn plate is electrically grounded the abrasion of an airbag wire on the sharp edge could cause a short circuit condition.As a result the airbag light may illuminate and/or the airbag may inadvertently deploy.Inadvertent deployments are most likely to occur during the airbag system's self-diagnostic test that initiates when the ignition switch is turned on.Ford modified the vehicle design in late January 2006 adding a protective tape over the sharp metal edge of the horn plate.Ford made additional design changes on MY 2007 vehicles to the horn plate, the clockspring jumper, and the connector layouts to further address this issue.ODI identified 318 deployment incidents with 121 alleged injury reports from subject vehicles.All but one of the incident and injury reports occurred in vehicles built before the January 2006 modification.In addition, there was one incident and alleged injury reported in the MY 2006 Mark LT vehicles that share the same design. In letters dated February 21 and April 11, 2011, Ford announced a recall of all of the approximately 1.3 million MY 2004-2006 F-150 vehicles built prior to January 24, 2006, the date the initial vehicle modification was made.In addition, approximately 14,000 MY 2006 Mark LT vehicles built prior to January 24, 2006 will also be recalled.Vehicles built after that date, which contain the modification, are not within the recall scope.Accordingly the investigation is closed.

Additional source detail variants (4)

Air Bags

ODI opened this investigation based on reports of inadvertent airbag deployment.Data provided by Ford indicated that the airbag clockspring jumper wire, which is situated inside the steering wheel assembly, was installed in a manner that would allow it to rub (abrade) against a sharp metal edge on the nearby horn plate.Because the horn plate is electrically grounded the abrasion of an airbag wire on the sharp edge could cause a short circuit condition.As a result the airbag light may illuminate and/or the airbag may inadvertently deploy.Inadvertent deployments are most likely to occur during the airbag system's self-diagnostic test that initiates when the ignition switch is turned on.Ford modified the vehicle design in late January 2006 adding a protective tape over the sharp metal edge of the horn plate.Ford made additional design changes on MY 2007 vehicles to the horn plate, the clockspring jumper, and the connector layouts to further address this issue.ODI identified 318 deployment incidents with 121 alleged injury reports from subject vehicles.All but one of the incident and injury reports occurred in vehicles built before the January 2006 modification.In addition, there was one incident and alleged injury reported in the MY 2006 Mark LT vehicles that share the same design. In letters dated February 21 and April 11, 2011, Ford announced a recall of all of the approximately 1.3 million MY 2004-2006 F-150 vehicles built prior to January 24, 2006, the date the initial vehicle modification was made.In addition, approximately 14,000 MY 2006 Mark LT vehicles built prior to January 24, 2006 will also be recalled.Vehicles built after that date, which contain the modification, are not within the recall scope.Accordingly the investigation is closed.

Air Bags:frontal:driver Side:inflator Module

ODI opened this investigation based on reports of inadvertent airbag deployment.Data provided by Ford indicated that the airbag clockspring jumper wire, which is situated inside the steering wheel assembly, was installed in a manner that would allow it to rub (abrade) against a sharp metal edge on the nearby horn plate.Because the horn plate is electrically grounded the abrasion of an airbag wire on the sharp edge could cause a short circuit condition.As a result the airbag light may illuminate and/or the airbag may inadvertently deploy.Inadvertent deployments are most likely to occur during the airbag system's self-diagnostic test that initiates when the ignition switch is turned on.Ford modified the vehicle design in late January 2006 adding a protective tape over the sharp metal edge of the horn plate.Ford made additional design changes on MY 2007 vehicles to the horn plate, the clockspring jumper, and the connector layouts to further address this issue.ODI identified 318 deployment incidents with 121 alleged injury reports from subject vehicles.All but one of the incident and injury reports occurred in vehicles built before the January 2006 modification.In addition, there was one incident and alleged injury reported in the MY 2006 Mark LT vehicles that share the same design. In letters dated February 21 and April 11, 2011, Ford announced a recall of all of the approximately 1.3 million MY 2004-2006 F-150 vehicles built prior to January 24, 2006, the date the initial vehicle modification was made.In addition, approximately 14,000 MY 2006 Mark LT vehicles built prior to January 24, 2006 will also be recalled.Vehicles built after that date, which contain the modification, are not within the recall scope.Accordingly the investigation is closed.

Air Bags:frontal

ODI opened this investigation based on reports of inadvertent airbag deployment.Data provided by Ford indicated that the airbag clockspring jumper wire, which is situated inside the steering wheel assembly, was installed in a manner that would allow it to rub (abrade) against a sharp metal edge on the nearby horn plate.Because the horn plate is electrically grounded the abrasion of an airbag wire on the sharp edge could cause a short circuit condition.As a result the airbag light may illuminate and/or the airbag may inadvertently deploy.Inadvertent deployments are most likely to occur during the airbag system's self-diagnostic test that initiates when the ignition switch is turned on.Ford modified the vehicle design in late January 2006 adding a protective tape over the sharp metal edge of the horn plate.Ford made additional design changes on MY 2007 vehicles to the horn plate, the clockspring jumper, and the connector layouts to further address this issue.ODI identified 318 deployment incidents with 121 alleged injury reports from subject vehicles.All but one of the incident and injury reports occurred in vehicles built before the January 2006 modification.In addition, there was one incident and alleged injury reported in the MY 2006 Mark LT vehicles that share the same design. In letters dated February 21 and April 11, 2011, Ford announced a recall of all of the approximately 1.3 million MY 2004-2006 F-150 vehicles built prior to January 24, 2006, the date the initial vehicle modification was made.In addition, approximately 14,000 MY 2006 Mark LT vehicles built prior to January 24, 2006 will also be recalled.Vehicles built after that date, which contain the modification, are not within the recall scope.Accordingly the investigation is closed.

Air Bags:frontal:sensor/control MODULE-INACTIVE

ODI opened this investigation based on reports of inadvertent airbag deployment.Data provided by Ford indicated that the airbag clockspring jumper wire, which is situated inside the steering wheel assembly, was installed in a manner that would allow it to rub (abrade) against a sharp metal edge on the nearby horn plate.Because the horn plate is electrically grounded the abrasion of an airbag wire on the sharp edge could cause a short circuit condition.As a result the airbag light may illuminate and/or the airbag may inadvertently deploy.Inadvertent deployments are most likely to occur during the airbag system's self-diagnostic test that initiates when the ignition switch is turned on.Ford modified the vehicle design in late January 2006 adding a protective tape over the sharp metal edge of the horn plate.Ford made additional design changes on MY 2007 vehicles to the horn plate, the clockspring jumper, and the connector layouts to further address this issue.ODI identified 318 deployment incidents with 121 alleged injury reports from subject vehicles.All but one of the incident and injury reports occurred in vehicles built before the January 2006 modification.In addition, there was one incident and alleged injury reported in the MY 2006 Mark LT vehicles that share the same design. In letters dated February 21 and April 11, 2011, Ford announced a recall of all of the approximately 1.3 million MY 2004-2006 F-150 vehicles built prior to January 24, 2006, the date the initial vehicle modification was made.In addition, approximately 14,000 MY 2006 Mark LT vehicles built prior to January 24, 2006 will also be recalled.Vehicles built after that date, which contain the modification, are not within the recall scope.Accordingly the investigation is closed.

PE09046 · Inadvertent Airbag Deployment

Opened Sep 24, 2009 · Closed Jan 19, 2010

Status: closed (inferred from source dates) · Air Bags; Air Bags:frontal; Air Bags:frontal:driver Side:inflator Module; Air Bags:frontal:sensor/control MODULE-INACTIVE

FORD REPORTS THAT THE INADVERTENT AIRBAG DEPLOYMENTS ARE MOST LIKELY CAUSED BY THE AIRBAG HORN MOUNTING PLATE'S SHARP METAL EDGE THAT EVENTUALLY CAN CHAFE/CUT THE AIRBAG CLOCKSPRING JUMPER WIRE LEADING TO A SHORT-TO-GROUND CONDITION.ONE HUNDRED EIGHTY TWO (182) OF THE 230 REPORTS WERE FOR AIRBAG DEPLOYMENTS RESULTING IN 56 INJURIES WITH REMAINING 48 REPORTS FOR AN AIRBAG LIGHT ILLUMINATION CONDITION.INJURIES INCLUDE ABRASION, CONTUSION AND CUTS TO THE ARM/HAND/FACE AND/OR UPPER BODY REGIONS.ONE OWNER REPORTED A BROKEN TOOTH AND TWO OWNERS REPORTED BEING KNOCKED UNCONSCIOUS AS A RESULT OF THE AIRBAG DEPLOYMENT.IN ADDITION, MY2004 AND MY2006 F-150 VEHICLES ALSO CONTAIN THE SAME DESIGN THAT RESULTED IN AN ADDITIONAL 89 REPORTS WITH 37 AIRBAG DEPLOYMENTS AND NINE INJURIES. FORD MADE AN INTERIM DESIGN CHANGE TO THE HORN MOUNTING PLATE IN JANUARY 2006 AND THEN MAJOR CHANGES TO THE HORN MOUNTING PLATE, AIRBAG MODULE AND CLOCKSPRING JUMPER WIRE DESIGNS IN JUNE 2006 FOR THE MY2007 VEHICLES.THIS PRELIMINARY EVALUATION IS UPGRADED TO AN ENGINEERING ANALYSIS (EA10-001) TO INCLUDE MY2004-2006 F-150 VEHICLES AND TO FURTHER EVALUATE THE CONDITION.

Additional source detail variants (4)

Air Bags

FORD REPORTS THAT THE INADVERTENT AIRBAG DEPLOYMENTS ARE MOST LIKELY CAUSED BY THE AIRBAG HORN MOUNTING PLATE'S SHARP METAL EDGE THAT EVENTUALLY CAN CHAFE/CUT THE AIRBAG CLOCKSPRING JUMPER WIRE LEADING TO A SHORT-TO-GROUND CONDITION.ONE HUNDRED EIGHTY TWO (182) OF THE 230 REPORTS WERE FOR AIRBAG DEPLOYMENTS RESULTING IN 56 INJURIES WITH REMAINING 48 REPORTS FOR AN AIRBAG LIGHT ILLUMINATION CONDITION.INJURIES INCLUDE ABRASION, CONTUSION AND CUTS TO THE ARM/HAND/FACE AND/OR UPPER BODY REGIONS.ONE OWNER REPORTED A BROKEN TOOTH AND TWO OWNERS REPORTED BEING KNOCKED UNCONSCIOUS AS A RESULT OF THE AIRBAG DEPLOYMENT.IN ADDITION, MY2004 AND MY2006 F-150 VEHICLES ALSO CONTAIN THE SAME DESIGN THAT RESULTED IN AN ADDITIONAL 89 REPORTS WITH 37 AIRBAG DEPLOYMENTS AND NINE INJURIES. FORD MADE AN INTERIM DESIGN CHANGE TO THE HORN MOUNTING PLATE IN JANUARY 2006 AND THEN MAJOR CHANGES TO THE HORN MOUNTING PLATE, AIRBAG MODULE AND CLOCKSPRING JUMPER WIRE DESIGNS IN JUNE 2006 FOR THE MY2007 VEHICLES.THIS PRELIMINARY EVALUATION IS UPGRADED TO AN ENGINEERING ANALYSIS (EA10-001) TO INCLUDE MY2004-2006 F-150 VEHICLES AND TO FURTHER EVALUATE THE CONDITION.

Air Bags:frontal:driver Side:inflator Module

FORD REPORTS THAT THE INADVERTENT AIRBAG DEPLOYMENTS ARE MOST LIKELY CAUSED BY THE AIRBAG HORN MOUNTING PLATE'S SHARP METAL EDGE THAT EVENTUALLY CAN CHAFE/CUT THE AIRBAG CLOCKSPRING JUMPER WIRE LEADING TO A SHORT-TO-GROUND CONDITION.ONE HUNDRED EIGHTY TWO (182) OF THE 230 REPORTS WERE FOR AIRBAG DEPLOYMENTS RESULTING IN 56 INJURIES WITH REMAINING 48 REPORTS FOR AN AIRBAG LIGHT ILLUMINATION CONDITION.INJURIES INCLUDE ABRASION, CONTUSION AND CUTS TO THE ARM/HAND/FACE AND/OR UPPER BODY REGIONS.ONE OWNER REPORTED A BROKEN TOOTH AND TWO OWNERS REPORTED BEING KNOCKED UNCONSCIOUS AS A RESULT OF THE AIRBAG DEPLOYMENT.IN ADDITION, MY2004 AND MY2006 F-150 VEHICLES ALSO CONTAIN THE SAME DESIGN THAT RESULTED IN AN ADDITIONAL 89 REPORTS WITH 37 AIRBAG DEPLOYMENTS AND NINE INJURIES. FORD MADE AN INTERIM DESIGN CHANGE TO THE HORN MOUNTING PLATE IN JANUARY 2006 AND THEN MAJOR CHANGES TO THE HORN MOUNTING PLATE, AIRBAG MODULE AND CLOCKSPRING JUMPER WIRE DESIGNS IN JUNE 2006 FOR THE MY2007 VEHICLES.THIS PRELIMINARY EVALUATION IS UPGRADED TO AN ENGINEERING ANALYSIS (EA10-001) TO INCLUDE MY2004-2006 F-150 VEHICLES AND TO FURTHER EVALUATE THE CONDITION.

Air Bags:frontal

FORD REPORTS THAT THE INADVERTENT AIRBAG DEPLOYMENTS ARE MOST LIKELY CAUSED BY THE AIRBAG HORN MOUNTING PLATE'S SHARP METAL EDGE THAT EVENTUALLY CAN CHAFE/CUT THE AIRBAG CLOCKSPRING JUMPER WIRE LEADING TO A SHORT-TO-GROUND CONDITION.ONE HUNDRED EIGHTY TWO (182) OF THE 230 REPORTS WERE FOR AIRBAG DEPLOYMENTS RESULTING IN 56 INJURIES WITH REMAINING 48 REPORTS FOR AN AIRBAG LIGHT ILLUMINATION CONDITION.INJURIES INCLUDE ABRASION, CONTUSION AND CUTS TO THE ARM/HAND/FACE AND/OR UPPER BODY REGIONS.ONE OWNER REPORTED A BROKEN TOOTH AND TWO OWNERS REPORTED BEING KNOCKED UNCONSCIOUS AS A RESULT OF THE AIRBAG DEPLOYMENT.IN ADDITION, MY2004 AND MY2006 F-150 VEHICLES ALSO CONTAIN THE SAME DESIGN THAT RESULTED IN AN ADDITIONAL 89 REPORTS WITH 37 AIRBAG DEPLOYMENTS AND NINE INJURIES. FORD MADE AN INTERIM DESIGN CHANGE TO THE HORN MOUNTING PLATE IN JANUARY 2006 AND THEN MAJOR CHANGES TO THE HORN MOUNTING PLATE, AIRBAG MODULE AND CLOCKSPRING JUMPER WIRE DESIGNS IN JUNE 2006 FOR THE MY2007 VEHICLES.THIS PRELIMINARY EVALUATION IS UPGRADED TO AN ENGINEERING ANALYSIS (EA10-001) TO INCLUDE MY2004-2006 F-150 VEHICLES AND TO FURTHER EVALUATE THE CONDITION.

Air Bags:frontal:sensor/control MODULE-INACTIVE

FORD REPORTS THAT THE INADVERTENT AIRBAG DEPLOYMENTS ARE MOST LIKELY CAUSED BY THE AIRBAG HORN MOUNTING PLATE'S SHARP METAL EDGE THAT EVENTUALLY CAN CHAFE/CUT THE AIRBAG CLOCKSPRING JUMPER WIRE LEADING TO A SHORT-TO-GROUND CONDITION.ONE HUNDRED EIGHTY TWO (182) OF THE 230 REPORTS WERE FOR AIRBAG DEPLOYMENTS RESULTING IN 56 INJURIES WITH REMAINING 48 REPORTS FOR AN AIRBAG LIGHT ILLUMINATION CONDITION.INJURIES INCLUDE ABRASION, CONTUSION AND CUTS TO THE ARM/HAND/FACE AND/OR UPPER BODY REGIONS.ONE OWNER REPORTED A BROKEN TOOTH AND TWO OWNERS REPORTED BEING KNOCKED UNCONSCIOUS AS A RESULT OF THE AIRBAG DEPLOYMENT.IN ADDITION, MY2004 AND MY2006 F-150 VEHICLES ALSO CONTAIN THE SAME DESIGN THAT RESULTED IN AN ADDITIONAL 89 REPORTS WITH 37 AIRBAG DEPLOYMENTS AND NINE INJURIES. FORD MADE AN INTERIM DESIGN CHANGE TO THE HORN MOUNTING PLATE IN JANUARY 2006 AND THEN MAJOR CHANGES TO THE HORN MOUNTING PLATE, AIRBAG MODULE AND CLOCKSPRING JUMPER WIRE DESIGNS IN JUNE 2006 FOR THE MY2007 VEHICLES.THIS PRELIMINARY EVALUATION IS UPGRADED TO AN ENGINEERING ANALYSIS (EA10-001) TO INCLUDE MY2004-2006 F-150 VEHICLES AND TO FURTHER EVALUATE THE CONDITION.

PE08001 · Loss Of Brake POWER-ASSIST

Opened Jan 8, 2008 · Closed May 9, 2008

Status: closed (inferred from source dates) · Service Brakes, Hydraulic:power Assist; Service Brakes, Hydraulic:power Assist:vacuum; Service Brakes, Hydraulic:power Assist:vacuum:hoses, Lines/piping, And Fittings

BY LETTER DATED MAY 5, 2008, FORD MOTOR COMPANY (FORD) NOTIFIED THE AGENCY THAT IT WILL CONDUCT A SAFETY RECALL (NHTSA RECALL NUMBER 08V-208) TO ADDRESS A MANUFACTURING DEFECT IN APPROXIMATELY 605,684 MODEL YEAR (MY) 2005 AND 2006 FORD F-150 AND LINCOLN MARK LT VEHICLES ORIGINALLY EQUIPPED WITH THE 5.4L DISPLACEMENT, 3-VALVE PER CYLINDER, V-8 ENGINE.THE RECALLED VEHICLES WERE BUILT FROM JULY 18, 2004 THROUGH MAY 31, 2006 AT THE DEARBORN TRUCK PLANT; FROM MAY 4, 2004 THROUGH MAY 31, 2006 AT THE KANSAS CITY ASSEMBLY PLANT; AND FROM APRIL 19, 2004 THROUGH MAY 31, 2006 AT THE NORFOLK TRUCK PLANT.THE VEHICLES WERE MANUFACTURED WITH THE SAME DEFECTIVE BRAKE BOOSTER VACUUM SUPPLY HOSE ASSEMBLY UNIQUE TO THE 5.4L V-8 ENGINE.FORD F-150 VEHICLES EQUIPPED WITH OPTIONALLY AVAILABLE 4.2L V6 AND 4.6L V-8 ENGINES ARE NOT INCLUDED IN THIS RECALL ACTION BECAUSE THEY UTILIZE A DIFFERENT, ONE-PIECE BRAKE BOOSTER VACUUM SUPPLY HOSE ASSEMBLY THAT DOES NOT EXHIBIT AN APPARENT DEFECT TREND. THE RECALLED VEHICLES UTILIZE A TWO-PIECE BRAKE BOOSTER VACUUM SUPPLY HOSE ASSEMBLY COMPRISED OF A STANDPIPE ASSEMBLY AND VACUUM HOSE.THE STANDPIPE ASSEMBLY ATTACHES TO A FITTING ON THE ENGINE AIR INTAKE MANIFOLD UTILIZING A FLEXIBLE RUBBER HOSE AND PLASTIC ELBOW.THE VACUUM HOSE ATTACHES TO THE OPPOSITE END OF THE STANDPIPE ASSEMBLY AND CONNECTS TO A CHECK VALVE FITTING AT THE BRAKE BOOSTER ASSEMBLY.ACCORDING TO FORD, THE PORTION OF THE BRAKE BOOSTER VACUUM SUPPLY HOSE ASSEMBLY ATTACHED TO THE INTAKE MANIFOLD MAY SWELL OVER TIME AND LOSE RETENTION FORCE, WHICH MAY ALLOW THE HOSE TO BECOME DETACHED FROM THE INTAKE MANIFOLD.SHOULD THE BRAKE BOOSTER VACUUM SUPPLY HOSE ASSEMBLY BE DISRUPTED, APPLICATION OF THE BRAKE PEDAL MAY DEPLETE THE VACUUM RESERVE AND CONSEQUENTLY RESULT IN LOSS OF BRAKE POWER-ASSIST. TO CORRECT THE SAFETY DEFECT, FORD WILL INSTALL AN IMPROVED DESIGN BRAKE BOOSTER VACUUM SUPPLY HOSE ASSEMBLY THAT UTILIZES A HOSE CLAMP AT THE INTAKE MANIFOLD ATTACHMENT. THIS REMEDY WILL BE PROVIDED FREE OF CHARGE FOR ALL RECALLED VEHICLES.LATER PRODUCTION FORD F-150 AND LINCOLN MARK LT VEHICLES BUILT AFTER MAY 2006 WERE MANUFACTURED WITH A HOSE CLAMP AT THE BRAKE BOOSTER VACUUM SUPPLY HOSE/INTAKE MANIFOLD ATTACHMENT AND ARE NOT AFFECTED. TO DATE, THE OFFICE OF DEFECTS INVESTIGATION (ODI) IS AWARE OF 324 NON-DUPLICATIVE COMPLAINTS AND 14 NON-INJURY CRASHES RELATED TO THE ALLEGED DEFECT IN THE SUBJECT VEHICLES.IN ADDITION, ODI IS AWARE OF 4,465 SUBJECT VEHICLES THAT EXPERIENCED ONE OR MORE WARRANTY CLAIMS TO REPAIR OR REPLACE THE SUBJECT BRAKE BOOSTER VACUUM SUPPLY HOSE ASSEMBLY. THE ACTION TAKEN BY FORD IS SUFFICIENT TO RESOLVE THE ISSUES RAISED BY THIS INVESTIGATION.ACCORDINGLY, THIS INVESTIGATION IS CLOSED.

Additional source detail variants (3)

Service Brakes, Hydraulic:power Assist

BY LETTER DATED MAY 5, 2008, FORD MOTOR COMPANY (FORD) NOTIFIED THE AGENCY THAT IT WILL CONDUCT A SAFETY RECALL (NHTSA RECALL NUMBER 08V-208) TO ADDRESS A MANUFACTURING DEFECT IN APPROXIMATELY 605,684 MODEL YEAR (MY) 2005 AND 2006 FORD F-150 AND LINCOLN MARK LT VEHICLES ORIGINALLY EQUIPPED WITH THE 5.4L DISPLACEMENT, 3-VALVE PER CYLINDER, V-8 ENGINE.THE RECALLED VEHICLES WERE BUILT FROM JULY 18, 2004 THROUGH MAY 31, 2006 AT THE DEARBORN TRUCK PLANT; FROM MAY 4, 2004 THROUGH MAY 31, 2006 AT THE KANSAS CITY ASSEMBLY PLANT; AND FROM APRIL 19, 2004 THROUGH MAY 31, 2006 AT THE NORFOLK TRUCK PLANT.THE VEHICLES WERE MANUFACTURED WITH THE SAME DEFECTIVE BRAKE BOOSTER VACUUM SUPPLY HOSE ASSEMBLY UNIQUE TO THE 5.4L V-8 ENGINE.FORD F-150 VEHICLES EQUIPPED WITH OPTIONALLY AVAILABLE 4.2L V6 AND 4.6L V-8 ENGINES ARE NOT INCLUDED IN THIS RECALL ACTION BECAUSE THEY UTILIZE A DIFFERENT, ONE-PIECE BRAKE BOOSTER VACUUM SUPPLY HOSE ASSEMBLY THAT DOES NOT EXHIBIT AN APPARENT DEFECT TREND. THE RECALLED VEHICLES UTILIZE A TWO-PIECE BRAKE BOOSTER VACUUM SUPPLY HOSE ASSEMBLY COMPRISED OF A STANDPIPE ASSEMBLY AND VACUUM HOSE.THE STANDPIPE ASSEMBLY ATTACHES TO A FITTING ON THE ENGINE AIR INTAKE MANIFOLD UTILIZING A FLEXIBLE RUBBER HOSE AND PLASTIC ELBOW.THE VACUUM HOSE ATTACHES TO THE OPPOSITE END OF THE STANDPIPE ASSEMBLY AND CONNECTS TO A CHECK VALVE FITTING AT THE BRAKE BOOSTER ASSEMBLY.ACCORDING TO FORD, THE PORTION OF THE BRAKE BOOSTER VACUUM SUPPLY HOSE ASSEMBLY ATTACHED TO THE INTAKE MANIFOLD MAY SWELL OVER TIME AND LOSE RETENTION FORCE, WHICH MAY ALLOW THE HOSE TO BECOME DETACHED FROM THE INTAKE MANIFOLD.SHOULD THE BRAKE BOOSTER VACUUM SUPPLY HOSE ASSEMBLY BE DISRUPTED, APPLICATION OF THE BRAKE PEDAL MAY DEPLETE THE VACUUM RESERVE AND CONSEQUENTLY RESULT IN LOSS OF BRAKE POWER-ASSIST. TO CORRECT THE SAFETY DEFECT, FORD WILL INSTALL AN IMPROVED DESIGN BRAKE BOOSTER VACUUM SUPPLY HOSE ASSEMBLY THAT UTILIZES A HOSE CLAMP AT THE INTAKE MANIFOLD ATTACHMENT. THIS REMEDY WILL BE PROVIDED FREE OF CHARGE FOR ALL RECALLED VEHICLES.LATER PRODUCTION FORD F-150 AND LINCOLN MARK LT VEHICLES BUILT AFTER MAY 2006 WERE MANUFACTURED WITH A HOSE CLAMP AT THE BRAKE BOOSTER VACUUM SUPPLY HOSE/INTAKE MANIFOLD ATTACHMENT AND ARE NOT AFFECTED. TO DATE, THE OFFICE OF DEFECTS INVESTIGATION (ODI) IS AWARE OF 324 NON-DUPLICATIVE COMPLAINTS AND 14 NON-INJURY CRASHES RELATED TO THE ALLEGED DEFECT IN THE SUBJECT VEHICLES.IN ADDITION, ODI IS AWARE OF 4,465 SUBJECT VEHICLES THAT EXPERIENCED ONE OR MORE WARRANTY CLAIMS TO REPAIR OR REPLACE THE SUBJECT BRAKE BOOSTER VACUUM SUPPLY HOSE ASSEMBLY. THE ACTION TAKEN BY FORD IS SUFFICIENT TO RESOLVE THE ISSUES RAISED BY THIS INVESTIGATION.ACCORDINGLY, THIS INVESTIGATION IS CLOSED.

Service Brakes, Hydraulic:power Assist:vacuum

BY LETTER DATED MAY 5, 2008, FORD MOTOR COMPANY (FORD) NOTIFIED THE AGENCY THAT IT WILL CONDUCT A SAFETY RECALL (NHTSA RECALL NUMBER 08V-208) TO ADDRESS A MANUFACTURING DEFECT IN APPROXIMATELY 605,684 MODEL YEAR (MY) 2005 AND 2006 FORD F-150 AND LINCOLN MARK LT VEHICLES ORIGINALLY EQUIPPED WITH THE 5.4L DISPLACEMENT, 3-VALVE PER CYLINDER, V-8 ENGINE.THE RECALLED VEHICLES WERE BUILT FROM JULY 18, 2004 THROUGH MAY 31, 2006 AT THE DEARBORN TRUCK PLANT; FROM MAY 4, 2004 THROUGH MAY 31, 2006 AT THE KANSAS CITY ASSEMBLY PLANT; AND FROM APRIL 19, 2004 THROUGH MAY 31, 2006 AT THE NORFOLK TRUCK PLANT.THE VEHICLES WERE MANUFACTURED WITH THE SAME DEFECTIVE BRAKE BOOSTER VACUUM SUPPLY HOSE ASSEMBLY UNIQUE TO THE 5.4L V-8 ENGINE.FORD F-150 VEHICLES EQUIPPED WITH OPTIONALLY AVAILABLE 4.2L V6 AND 4.6L V-8 ENGINES ARE NOT INCLUDED IN THIS RECALL ACTION BECAUSE THEY UTILIZE A DIFFERENT, ONE-PIECE BRAKE BOOSTER VACUUM SUPPLY HOSE ASSEMBLY THAT DOES NOT EXHIBIT AN APPARENT DEFECT TREND. THE RECALLED VEHICLES UTILIZE A TWO-PIECE BRAKE BOOSTER VACUUM SUPPLY HOSE ASSEMBLY COMPRISED OF A STANDPIPE ASSEMBLY AND VACUUM HOSE.THE STANDPIPE ASSEMBLY ATTACHES TO A FITTING ON THE ENGINE AIR INTAKE MANIFOLD UTILIZING A FLEXIBLE RUBBER HOSE AND PLASTIC ELBOW.THE VACUUM HOSE ATTACHES TO THE OPPOSITE END OF THE STANDPIPE ASSEMBLY AND CONNECTS TO A CHECK VALVE FITTING AT THE BRAKE BOOSTER ASSEMBLY.ACCORDING TO FORD, THE PORTION OF THE BRAKE BOOSTER VACUUM SUPPLY HOSE ASSEMBLY ATTACHED TO THE INTAKE MANIFOLD MAY SWELL OVER TIME AND LOSE RETENTION FORCE, WHICH MAY ALLOW THE HOSE TO BECOME DETACHED FROM THE INTAKE MANIFOLD.SHOULD THE BRAKE BOOSTER VACUUM SUPPLY HOSE ASSEMBLY BE DISRUPTED, APPLICATION OF THE BRAKE PEDAL MAY DEPLETE THE VACUUM RESERVE AND CONSEQUENTLY RESULT IN LOSS OF BRAKE POWER-ASSIST. TO CORRECT THE SAFETY DEFECT, FORD WILL INSTALL AN IMPROVED DESIGN BRAKE BOOSTER VACUUM SUPPLY HOSE ASSEMBLY THAT UTILIZES A HOSE CLAMP AT THE INTAKE MANIFOLD ATTACHMENT. THIS REMEDY WILL BE PROVIDED FREE OF CHARGE FOR ALL RECALLED VEHICLES.LATER PRODUCTION FORD F-150 AND LINCOLN MARK LT VEHICLES BUILT AFTER MAY 2006 WERE MANUFACTURED WITH A HOSE CLAMP AT THE BRAKE BOOSTER VACUUM SUPPLY HOSE/INTAKE MANIFOLD ATTACHMENT AND ARE NOT AFFECTED. TO DATE, THE OFFICE OF DEFECTS INVESTIGATION (ODI) IS AWARE OF 324 NON-DUPLICATIVE COMPLAINTS AND 14 NON-INJURY CRASHES RELATED TO THE ALLEGED DEFECT IN THE SUBJECT VEHICLES.IN ADDITION, ODI IS AWARE OF 4,465 SUBJECT VEHICLES THAT EXPERIENCED ONE OR MORE WARRANTY CLAIMS TO REPAIR OR REPLACE THE SUBJECT BRAKE BOOSTER VACUUM SUPPLY HOSE ASSEMBLY. THE ACTION TAKEN BY FORD IS SUFFICIENT TO RESOLVE THE ISSUES RAISED BY THIS INVESTIGATION.ACCORDINGLY, THIS INVESTIGATION IS CLOSED.

Service Brakes, Hydraulic:power Assist:vacuum:hoses, Lines/piping, And Fittings

BY LETTER DATED MAY 5, 2008, FORD MOTOR COMPANY (FORD) NOTIFIED THE AGENCY THAT IT WILL CONDUCT A SAFETY RECALL (NHTSA RECALL NUMBER 08V-208) TO ADDRESS A MANUFACTURING DEFECT IN APPROXIMATELY 605,684 MODEL YEAR (MY) 2005 AND 2006 FORD F-150 AND LINCOLN MARK LT VEHICLES ORIGINALLY EQUIPPED WITH THE 5.4L DISPLACEMENT, 3-VALVE PER CYLINDER, V-8 ENGINE.THE RECALLED VEHICLES WERE BUILT FROM JULY 18, 2004 THROUGH MAY 31, 2006 AT THE DEARBORN TRUCK PLANT; FROM MAY 4, 2004 THROUGH MAY 31, 2006 AT THE KANSAS CITY ASSEMBLY PLANT; AND FROM APRIL 19, 2004 THROUGH MAY 31, 2006 AT THE NORFOLK TRUCK PLANT.THE VEHICLES WERE MANUFACTURED WITH THE SAME DEFECTIVE BRAKE BOOSTER VACUUM SUPPLY HOSE ASSEMBLY UNIQUE TO THE 5.4L V-8 ENGINE.FORD F-150 VEHICLES EQUIPPED WITH OPTIONALLY AVAILABLE 4.2L V6 AND 4.6L V-8 ENGINES ARE NOT INCLUDED IN THIS RECALL ACTION BECAUSE THEY UTILIZE A DIFFERENT, ONE-PIECE BRAKE BOOSTER VACUUM SUPPLY HOSE ASSEMBLY THAT DOES NOT EXHIBIT AN APPARENT DEFECT TREND. THE RECALLED VEHICLES UTILIZE A TWO-PIECE BRAKE BOOSTER VACUUM SUPPLY HOSE ASSEMBLY COMPRISED OF A STANDPIPE ASSEMBLY AND VACUUM HOSE.THE STANDPIPE ASSEMBLY ATTACHES TO A FITTING ON THE ENGINE AIR INTAKE MANIFOLD UTILIZING A FLEXIBLE RUBBER HOSE AND PLASTIC ELBOW.THE VACUUM HOSE ATTACHES TO THE OPPOSITE END OF THE STANDPIPE ASSEMBLY AND CONNECTS TO A CHECK VALVE FITTING AT THE BRAKE BOOSTER ASSEMBLY.ACCORDING TO FORD, THE PORTION OF THE BRAKE BOOSTER VACUUM SUPPLY HOSE ASSEMBLY ATTACHED TO THE INTAKE MANIFOLD MAY SWELL OVER TIME AND LOSE RETENTION FORCE, WHICH MAY ALLOW THE HOSE TO BECOME DETACHED FROM THE INTAKE MANIFOLD.SHOULD THE BRAKE BOOSTER VACUUM SUPPLY HOSE ASSEMBLY BE DISRUPTED, APPLICATION OF THE BRAKE PEDAL MAY DEPLETE THE VACUUM RESERVE AND CONSEQUENTLY RESULT IN LOSS OF BRAKE POWER-ASSIST. TO CORRECT THE SAFETY DEFECT, FORD WILL INSTALL AN IMPROVED DESIGN BRAKE BOOSTER VACUUM SUPPLY HOSE ASSEMBLY THAT UTILIZES A HOSE CLAMP AT THE INTAKE MANIFOLD ATTACHMENT. THIS REMEDY WILL BE PROVIDED FREE OF CHARGE FOR ALL RECALLED VEHICLES.LATER PRODUCTION FORD F-150 AND LINCOLN MARK LT VEHICLES BUILT AFTER MAY 2006 WERE MANUFACTURED WITH A HOSE CLAMP AT THE BRAKE BOOSTER VACUUM SUPPLY HOSE/INTAKE MANIFOLD ATTACHMENT AND ARE NOT AFFECTED. TO DATE, THE OFFICE OF DEFECTS INVESTIGATION (ODI) IS AWARE OF 324 NON-DUPLICATIVE COMPLAINTS AND 14 NON-INJURY CRASHES RELATED TO THE ALLEGED DEFECT IN THE SUBJECT VEHICLES.IN ADDITION, ODI IS AWARE OF 4,465 SUBJECT VEHICLES THAT EXPERIENCED ONE OR MORE WARRANTY CLAIMS TO REPAIR OR REPLACE THE SUBJECT BRAKE BOOSTER VACUUM SUPPLY HOSE ASSEMBLY. THE ACTION TAKEN BY FORD IS SUFFICIENT TO RESOLVE THE ISSUES RAISED BY THIS INVESTIGATION.ACCORDINGLY, THIS INVESTIGATION IS CLOSED.