More warning signs than most F-150 years

Owner complaints for the 2004 Ford F-150 are substantially higher than the model-year median of 676.

About this comparison →

When problems were reported

Mileage at the reported incident

1,749 reports with mileage · 280 unknown

NHTSA’s mileage field refers to the reported incident, not necessarily the filing date. This shows report counts, not the likelihood of a failure.

What to inspect

Issues worth paying extra attention to based on owner reports.

  • Visibility. Review the 841 owner reports in this category and discuss these concerns during a pre-purchase inspection. Read reports →
  • Power Train. Review the 232 owner reports in this category and discuss these concerns during a pre-purchase inspection. Read reports →
  • Engine And Engine Cooling. Review the 167 owner reports in this category and discuss these concerns during a pre-purchase inspection. Read reports →

NHTSA owner reports · September 18, 2026 snapshot.

75 crash reports40 fire reports58 injury reports

Power Train complaints

232 reports
Clear category filter
Mileage unknown · Dec 28, 2004
Power Train

2004 FORD F-150 HAS HAD A SEVERE VIBRATION IN THE STEERING WHEEL, GAS AND BRAKE PEDAL, FLOORBOARD, SEAT, ETC. AT ALL SPEEDS AND WORSE AFTER DRIVING FOR 20-30 MILES, THAT CAUSES ARMS AND LEGS TO TINGLE AND RIGHT LEG TO GO NUMB RESULTING IN HAVING TO USE LEFT FOOT TO BRAKE SINCE WEEK THREE OF OWNERSHIP. THIS VIBRATION IS ALSO CAU…

Read full complaint

2004 FORD F-150 HAS HAD A SEVERE VIBRATION IN THE STEERING WHEEL, GAS AND BRAKE PEDAL, FLOORBOARD, SEAT, ETC. AT ALL SPEEDS AND WORSE AFTER DRIVING FOR 20-30 MILES, THAT CAUSES ARMS AND LEGS TO TINGLE AND RIGHT LEG TO GO NUMB RESULTING IN HAVING TO USE LEFT FOOT TO BRAKE SINCE WEEK THREE OF OWNERSHIP. THIS VIBRATION IS ALSO CAUSING SEVERE BACK PAIN. THIS TRUCK ALSO HAS HAD A CLUNKING AND SQUEALING IN THE REAR END. THIS ISSUE IS HAPPENING IN THE MAJORITY OF 04 AND 05 F-150'S AND FORD DOES NOT KNOW HOW TO FIX IT. DSB HAS SAID THAT SINCE THERE IS A LIABILITY ISSUE, THEY CANNOT MAKE A RULING. SO, I AM STUCK WITH A $30,000 VEHICLE THAT I CANNOT PHYSICALLY STAND TO DRIVE!!! FORD NEEDS TO COME UP WITH A FIX OR RECALL THEM ALL!!! NOTE: HAVE HAD DAMPER INSTALLED, DRIVE SHAFT INDEXED TWICE AND CLUTCHES IN THE REAR END REPLACED TWICE. THE REAR END IS ALSO CLUNKING AND WHINING. *JB

NHTSA ODI #10104674

150 miles · Dec 21, 2004
Power Train

THE TRUCK HAS HAD MULTIPLE VIBRATION AT VARYING SPEEDS BUT MOSTLY AT HIGHWAY SPEEDS SINCE IT WAS BOUGHT. THE F150 HAS BEEN IN MANY TIMES WITH MANY PARTS REPLACED, VIBRATIONS SEEM TO BE WORSE NOW THAN BEFORE. I TRIED FACTORY BUYBACK WITH FORDS BOARD BUT THEY SEEM TO THINK IT IS FIXED, I HAVE ASK THEM TO DRIVE THE TRUCK AGAIN LIKE…

Read full complaint

THE TRUCK HAS HAD MULTIPLE VIBRATION AT VARYING SPEEDS BUT MOSTLY AT HIGHWAY SPEEDS SINCE IT WAS BOUGHT. THE F150 HAS BEEN IN MANY TIMES WITH MANY PARTS REPLACED, VIBRATIONS SEEM TO BE WORSE NOW THAN BEFORE. I TRIED FACTORY BUYBACK WITH FORDS BOARD BUT THEY SEEM TO THINK IT IS FIXED, I HAVE ASK THEM TO DRIVE THE TRUCK AGAIN LIKE THE DEALERSHIP DID TO VERIFY THE VIBRATIONS. THEY SEEM UNINTERESTED IN MY PROBLEM AND THEY HAVE NOT FIXED A [XXX] THING SINCE THE BOARD DECISION THAT IT IS FIXED BUT IT IS WORSE AND I TOLD THEM IT WAS WORSE PERSONALLY, THE TRUCK IS A PILE OF POOP AND FORD KNOWS IT BUT BECAUSE MANY OF THESE TRUCKS HAVE THE PROBLEMS THEY ARE NOT WILLING TO FIX THE PROBLEM. *AK INFORMATION REDACTED PURSUANT TO THE FREEDOM OF INFORMATION ACT (FOIA), 5 U.S.C. 552(B)(6). *TR

NHTSA ODI #10104225

1 miles · Dec 13, 2004
Power Train

2004 SCREW LARIAT - VIBRATION THROUGHOUT WHOLE VEHICLE AT SPEEDS BETWEEN 45-60MPH, ONLY IN O/D. I BELIEVE THIS IS RELATED TO THE CONTENTS OF TSB 04-25-07 AND TSB 04-25-08. *AK

NHTSA ODI #10102889

Mileage unknown · Dec 7, 2004
Power Train

TRANSMISSION TENDS TO POP AND SWITCH GEARS ON ITS OWN. REVERSE OCCASIONALLY SERVES LIKE THE NEUTRAL GEAR, PREVENTING VEHICLE FROM BACKING UP. VEHICLE TAKEN TO DEALER FOR TESTING , BUT RESULTS SHOW THAT EVERYTHING IS NORMAL. THIS TENDS TO BE A PROBLEM ONLY WHEN CONSUMER IS OPERATING VEHICLE ON OWN TIME.*AK

NHTSA ODI #10103220

3,000 miles · Dec 3, 2004
Power Train

2004 F-150 VIBRATION ISSUE. THIS IS A REAL AND SERIOUS ISSUE. I TOOK MY TRUCK IN FOR A DAIGNOSIS ON THE VIBRATION. THE DEALER SAID THEY NARROWED IT DOWN TO THE DRIVESHAFT. I WAITED 3 WEEKS FOR A REPLACEMENT DUE TO THE FACT THAT THE DRIVESHAFT WAS ON BACK ORDER. AFTER REPLACEMENT OF THE DRIVESHAFT, DEALER INFORMED ME THAT IT HAD …

Read full complaint

2004 F-150 VIBRATION ISSUE. THIS IS A REAL AND SERIOUS ISSUE. I TOOK MY TRUCK IN FOR A DAIGNOSIS ON THE VIBRATION. THE DEALER SAID THEY NARROWED IT DOWN TO THE DRIVESHAFT. I WAITED 3 WEEKS FOR A REPLACEMENT DUE TO THE FACT THAT THE DRIVESHAFT WAS ON BACK ORDER. AFTER REPLACEMENT OF THE DRIVESHAFT, DEALER INFORMED ME THAT IT HAD NOT CURED THE PROBLEM. I WAS TOLD THAT FORD WAS LOOKING FOR A FIX AND THEY WOULD GET BACK TO ME WHEN THEY FIGURE IT OUT. AFTER PICKING UP MY TRUCK FROM THE DEALER I TOOK IT ON THE FREEWAY TO TEST IT OUT, TOOK TO ABOUT 55 MPH AND APPLIED THE BRAKES,I FELT A SERIOUS VIBRATION FROM THE STEERING WHEEL. I CALLED THE DEALER BACK AND NOTIFIED THEM OF THE UNSAFE HANDLING OF THE TRUCK. I WAS TOLD THAT THE TRUCK WAS SAFE TO DRIVE. BUT NO GUARANTEES!!! I CARRY MY CHILDREN IN THIS VEHICLE. SOMETHING HAS TO BE DONE ABOUT THIS ISSUE. PEOPLE'S LIVES ARE AT STAKE. REMEMBER THE EXPLORER AND THE DEATHS DUE TO ROLLOVER!!! THNK YOU FOR YOUR TIME.*AK

NHTSA ODI #10102106

45 miles · Dec 3, 2004
Power Train

I PURCHASED A FORD F150 , THIER WAS A VIBRIATION IN STEERING ,CALLED SALE'S MAN AND INFORMED HIM OF PROBLEM .WE SET UP A SERVICE TO BALANCE TIRE'S,THIS SOLVED STEERING VIBRATION, BUT CAUSED VIBRATION IN REAREND .CALLED SERVICE TO HAVE MY TRUCK INSPECTED ,UPON INSPECTION AND TSB A VIBRATION DAMPNER WAS INSTALLED ALONG WITH REBU…

Read full complaint

I PURCHASED A FORD F150 , THIER WAS A VIBRIATION IN STEERING ,CALLED SALE'S MAN AND INFORMED HIM OF PROBLEM .WE SET UP A SERVICE TO BALANCE TIRE'S,THIS SOLVED STEERING VIBRATION, BUT CAUSED VIBRATION IN REAREND .CALLED SERVICE TO HAVE MY TRUCK INSPECTED ,UPON INSPECTION AND TSB A VIBRATION DAMPNER WAS INSTALLED ALONG WITH REBUILDING REAREND.AFTER RECEIVING MY TRUCK BACK ,STILL HAD VIBRATION BETWEEN 40 AND 50 MPH TOOK BACK TO SERVJCE THEY REPLACED REAREND,DRIVESHAFT ,CARRIERBARRING ,DROVE FINE FOR TWO DAY'S THEN VIBRATION WAS BACK . UPON VISIUALLY INSPECTING THE WORK , I NOTICED REAREND WAS SITTING ABOUT 1 INCH FARTHER TO THE RIGHT , I NOW AM GETTING READY TO TAKE BACK TO SERVICE TO HAVE WORK PERFORMED AGAIN.I HAVE 5,161 MILE'S ON MY TRUCK, REAREND WAS FIRST WORKED ON BEFORE 3000 MILE'S AND FIRST OIL CHANGE.VIBRATION PERSISTS.*AK

NHTSA ODI #10102102

14,000 miles · Dec 1, 2004
Power Train

I BOUGHT A 2004 F150 STX 4X4 IN LATE FEBRUARY OF 2004. THE TRUCK HAS A 4.6 LITER V-8, AUTOMATIC TRANSMISSION AND A 3.73 LIMITED SLIP REAREND. SINCE I HAVE HAD THE TRUCK THE REAREND HAS DEVELOPED A LOUD WHINING SOUND AND SLUNG THE REAREND LUBE OUT AND UNDER THE BED. IT WAS REPLACED AND HAVE HAD NOT FURTHER TROUBLE IN THAT AREA…

Read full complaint

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

NHTSA ODI #10100880

161 miles · Nov 28, 2004
Power Train

I RECENTLY PURCHASED A 2004 FORD F150 SUPERCAB PICKUP TRUCK, AS I LEFT THE DEALERSHIP AND STARTED HOME I NOTICED THAT THE BED WAS SHAKING TERRIBLY BETWEEN 55 AND 62 MPH. I CALLED THE DEALERSHIP BEFORE I WAS THREE MILES AWAY AND THEY TOLD ME TO BRING IT BACK THE NEXT DAY, I DID. THEY SAID THAT IT WAS FIXED, IT WASN'T. I LEFT A…

Read full complaint

I RECENTLY PURCHASED A 2004 FORD F150 SUPERCAB PICKUP TRUCK, AS I LEFT THE DEALERSHIP AND STARTED HOME I NOTICED THAT THE BED WAS SHAKING TERRIBLY BETWEEN 55 AND 62 MPH. I CALLED THE DEALERSHIP BEFORE I WAS THREE MILES AWAY AND THEY TOLD ME TO BRING IT BACK THE NEXT DAY, I DID. THEY SAID THAT IT WAS FIXED, IT WASN'T. I LEFT AGAIN (THE DAY AFTER I PURCHASED) AND IMMEDIATELY CALLED THE SERVICE DEPARTMENT AT JACKY JONES FORD IN SWEETWATER, TN., AND TOLD THEM THE PROBLEM WAS JUST AS BAD. THE SERVICE CLERK (JASON) TOLD ME THAT THERE WAS A PROBLEM WITH THIS MODEL TRUCK AND THAT FORD WAS IN THE PROCESS OF FIXING IT. THAT WAS A MONTH AGO. NOW I HAVE LEARNED THAT THERE ARE HUNDREDS, MAYBE THOUSANDS OF FORD F150'S WITH THIS PROBLEM AND THEY ARE NOT BEING FIXED. I CANNOT GET THE DEALER TO RESCHEDULE A TIME TO REPAIR MY TRUCK.*AK

NHTSA ODI #10100672

50 miles · Nov 20, 2004
Power Train

VEHICLE HAS A SHIMMY (VIBRATION) AT OR ABOVE 45 MPH, INCREASES WHEN LOADED AND FEELS UNSAFE TO DRIVE. *AK

NHTSA ODI #10100248

8,500 miles · Nov 16, 2004
Power Train

NOISE IN REAR END ABOUNT 60 TO 70 MILES A HOUR.WHINNING NOISE.*AK

NHTSA ODI #10100032

Official recalls

5

11V385000 · Fuel System, Gasoline:storage:tank Assembly:mounting

Jul 29, 2011

FORD IS RECALLING CERTAIN 1997 THROUGH 2003 MODEL YEAR FORD F-150, 2004 MODEL YEAR FORD F-150 HERITAGE, 1997 THROUGH 1999 MODEL YEAR F-250 LESS THAN 8,500 LBS. GROSS VEHICLE WEIGHT RATING (GVWR), AND 2002 AND 2003 LINCOLN BLACKWOOD VEHICLES MANUFACTURED FROM JUNE 20, 1995, THROUGH AUGUST 4, 2004, ORIGINALLY SOLD, OR CURRENTLY REGISTERED IN, CONNECTICUT, DELAWARE, ILLINOIS, INDIANA, IOWA, KENTUCKY, MAINE, MARYLAND, MASSACHUSETTS, MICHIGAN, MINNESOTA, MISSOURI, NEW HAMPSHIRE, NEW JERSEY, NEW YORK, OHIO, PENNSYLVANIA, RHODE ISLAND, VERMONT, WEST VIRGINIA, WISCONSIN, AND THE DISTRICT OF COLUMBIA. PROLONGED EXPOSURE TO ROAD DEICING CHEMICALS MAY CAUSE SEVERE CORROSION OF THE FUEL TANK STRAPS WHICH SECURE THE TANK TO THE VEHICLE.

Consequence & remedy

Consequence: AS A RESULT OF THE CORROSION, ONE OR BOTH STRAPS MAY FAIL ALLOWING THE FUEL LINES TO SEPARATE FROM THE TANK, OR IN SOME CASES, CAUSING THE TANK TO CONTACT THE GROUND. EITHER SCENARIO MAY RESULT IN A FUEL LEAK PRESENTING A FIRE HAZARD.

Remedy: FORD WILL NOTIFY OWNERS AND INSTRUCT THEM TO TAKE THEIR VEHICLES TO A FORD OR LINCOLN DEALER TO HAVE THE FUEL TANK STRAPS REPLACED WITH STRAPS THAT HAVE INCREASED CORROSION PROTECTION. EARLY IN THIS CAMPAIGN, IF REPLACEMENT STRAPS ARE NOT AVAILABLE, DEALERS MAY INSTALL A CABLE SUPPORT UNDER THE STRAP AS AN INTERIM REPAIR OR A STEEL REINFORCEMENT OVER THE EXISTING STRAP AS A PERMANENT REPAIR. ANY REPAIRS WILL BE PERFORMED FREE OF CHARGE. THE SAFETY RECALL BEGAN ON SEPTEMBER 16, 2011. OWNERS MAY CONTACT FORD MOTOR COMPANY CUSTOMER RELATIONSHIP CENTER AT 1-866-436-7332. FORD'S RECALL CAMPAIGN NUMBER IS 11S21

11V107000 · Air Bags:frontal:driver Side:inflator Module

Feb 23, 2011

FORD IS RECALLING CERTAIN MODEL YEAR 2004-2006 F-150 PICK UP TRUCKS AS WELL AS CERTAIN MODEL YEAR 2006 LINCOLN MARK LT VEHICLES. IF THE CLOCKSPRING JUMPER WIRE COMES IN CONTACT WITH THE DRIVER SIDE FRONTAL AIR BAG LOWER HORN PLATE, THE WIRE INSULATION MAY BECOME CHAFED, CREATING A POTENTIAL FOR A SHORT CIRCUIT. IF THIS OCCURS THE AIR BAG WARNING LAMP MAY ILLUMINATE INDICATING THAT SERVICE IS REQUIRED.

Consequence & remedy

Consequence: THE DRIVER SIDE FRONTAL AIR BAG COULD INADVERTENTLY DEPLOY INCREASING THE RISK OF INJURY OR LOSS OF VEHICLE CONTROL IF OCCURRING WHILE IN MOTION.

Remedy: FORD WILL NOTIFY OWNERS AND INSTRUCT THEM TO TAKE THEIR VEHICLES TO A FORD OR LINCOLN/MERCURY DEALER TO HAVE A NEW CLOCKSPRING JUMPER WIRE INSTALLED THAT INCORPORATES A PROTECTIVE MESH COVER. REPAIRS WILL BE PERFORMED FREE OF CHARGE. THIS SAFETY RECALL BEGAN ON SOME VEHICLES IN MARCH 2011. THE RECALL CAMPAIGN ON THE EXPANDED POPULATION IS EXPECTED TO BEGIN ON OR ABOUT MAY 9, 2011. OWNERS MAY CONTACT THE FORD MOTOR COMPANY CUSTOMER RELATIONSHIP CENTER AT 1-866-436-7332.

07V336000 · Vehicle Speed Control

Aug 3, 2007

ON CERTAIN PICKUP TRUCKS, PASSENGER VEHICLES, SPORT UTILITY VEHICLES, AND MOTOR HOMES CHASSIS, THE SPEED CONTROL DEACTIVATION SWITCH MAY, UNDER CERTAIN CONDITIONS, LEAK INTERNALLY AND THEN OVERHEAT, SMOKE, OR BURN.

Consequence & remedy

Consequence: THIS COULD RESULT IN AN UNDERHOOD FIRE.

Remedy: DEALERS WILL INSTALL A FUSED WIRING HARNESS. OWNERS OF THE PASSENGER CARS INCLUDED IN THIS CAMPAIGN WILL BE INSTRUCTED TO RETURN THEIR VEHICLES TO THEIR DEALERS TO HAVE THE SPEED CONTROL DEACTIVATION SWITCH DISCONNECTED AS AN INTERIM REPAIR. AS SOON AS REPAIR PARTS ARE AVAILABLE (EXPECTED OCTOBER 2007), OWNERS WILL BE INSTRUCTED TO RETURN TO THE DEALERS FOR INSTALLATION OF A FUSED WIRING HARNESS. THE RECALL BEGAN ON AUGUST 13, 2007, AND MAILING COMPLETED BY SEPTEMBER 19, 2007. OWNERS MAY CONTACT FORD AT 1-888-222-2751.

04V443000 · Fuel System, Gasoline:storage:tank Assembly:mounting

Sep 13, 2004

ON CERTAIN TRUCKS EQUIPPED WITH 4.2L, 4.6L AND 5.4L GASOLINE ENGINES, THE FUEL TANK MAY HAVE A DEPRESSION AT THE SEAM BETWEEN THE TOP AND BOTTOM HALVES OF THE TANK. IF A DEPRESSION IS LARGE ENOUGH, FUEL MAY PERMEATE THE FUEL TANK WALL RESULTING IN A FUEL ODOR, ILLUMINATION, OF THE "SERVICE ENGINE SOON" INDICATOR LIGHT, OR A FUEL LEAK.

Consequence & remedy

Consequence: FUEL LEAKAGE, IN THE PRESENCE OF AN IGNITION SOURCE, COULD RESULT IN A FIRE.

Remedy: DEALERS WILL REPLACE THE FUEL TANK. THE RECALL BEGAN SEPTEMBER 17, 2004. OWNERS SHOULD CONTACT FORD AT 1-800-392-3673.

04V200000 · Fuel System, Gasoline:storage:tank Assembly

Apr 26, 2004

CERTAIN PICKUP TRUCKS MAY HAVE A FUEL TANK WITH LOCALIZED DEPRESSIONS IN THE FUEL TANK WALL AT THE SEAM BETWEEN TOP AND BOTTOM HALVES OF THE TANK. IF A DEPRESSION IS LARGE ENOUGH, FUEL MAY PERMEATE THE FUEL TANK WALL RESULTING IN A FUEL ODOR, OR THE "SERVICE ENGINE SOON" INDICATOR LIGHT IN THE INSTRUMENT CLUSTER MAY ILLUMINATE.

Consequence & remedy

Consequence: IF LEFT UNCORRECTED, A FUEL LEAK COULD EVENTUALLY DEVELOP.

Remedy: DEALERS WILL REPLACE THE FUEL TANK ON THESE VEHICLES. OWNER NOTIFICATION BEGAN ON MAY 6, 2004. OWNERS SHOULD CONTACT FORD AT 1-800-248-0186.

Model-level recall history does not show whether a particular VIN is affected or has received a repair. Check a VIN with NHTSA ↗

NHTSA investigations

4

EA11006 · Fuel Tank Strap Failure Due To Corrosion

Opened May 4, 2011 · Closed Aug 19, 2011

Status: closed (inferred from source dates) · Fuel System, Gasoline:storage:tank Assembly; Fuel System, Gasoline:storage:tank Assembly:mounting; Fuel System, Other:storage:tank Assembly; Fuel System, Other:storage:tank Assembly:mounting

One or both of the steel straps holding up the fuel tank and attaching it to the truck frame can corrode and fail (break or separate).If one strap fails, the tank may tilt and drop and possibly contact the road surface.If both straps break, the entire tank may drop to the road.If either failure occurs while the vehicle is being driven, contact with the road can abrade the tank and create a hole from which gasoline can spill.When the tank drops, it remains attached to the vehicle only by the fuel filler hose and/or supply lines, or in rare instances, by the skid plate, if present.In some cases the weight of the tank sufficiently strained the hoses and fittings and caused separation and subsequent fuel leaks from those connections.The fire hazard created by leaking gasoline is increased by the possible presence of sparks created by the metal tank being dragged along the road.Corrosion of the straps appears to be caused by prolonged exposure to road deicers, frequently road salt, used to treat snow or ice covered roads.States in which large quantities of deicers are applied to roads during the winter season (salt belt states) account for the predominant portion of strap failures.Vehicles in these salt belt states are prone to experience corrosion related failures more frequently and earlier in a vehicle?s life cycle.Ford reports approximately 97 percent of reports it received relating to strap failure involve vehicles that were operated in these high corrosion areas, and 95 percent of the reports to NHTSA involved such vehicles.Approximately one-third of F-150 U.S. production was sold in salt belt states.ODI has included in the above counts reports it has received from consumers and reports it has received from Ford in which either the complaint involved confirmed strap corrosion or ODI's assessment of available information suggests corrosion caused the reported problem.Among the incidents reported to NHTSA, 441 involved one or both straps failing due to corrosion, 353 involved the fuel tank dropping and/or dragging on the ground, and 180 involved fuel leakage.ODI has received four reports of strap failure in which the leaking fuel ignited but self-extinguished, and one incident in which fire destroyed the vehicle and injured its driver.Ford reported the same injury incident and three other unique fire incidents, including two in which the leaking fuel ignited and fire destroyed the vehicle.There were no injuries associated with the three unique Ford incidents.Ford has agreed to conduct a recall to repair the subject vehicles.The recall will cover vehicles that were originally sold or are currently registered in salt belt states (regardless of vehicle age).The vehiclesincluded in the recall are those subject vehicles that are, or have ever been, registered in Connecticut, Delaware, Iowa, Illinois, Indiana, Kentucky, Maine, Maryland, Massachusetts, Michigan, Minnesota, Missouri, New Hampshire, New Jersey, New York, Ohio, Pennsylvania, Rhode Island, Vermont, West Virginia, Wisconsin, or the District of Columbia.Ford's recall action appears to adequately address the problem at this time.The above vehicle population (1,340,349) includes subject vehicles originally delivered or sold in salt belt states.ODI does not know the current or historical locations of all subject vehicles.According to Ford approximately 73% of the recall population is currently registered (a 27% attrition rate).Ford is also recalling certain MY 1997-1999 F-250 vehicles (under 8,500 GVWR), and MY2002-2003 Lincoln Blackwood vehicles for the same condition, resulting in an estimated 1.1 million total vehicles

Additional source detail variants (4)

Fuel System, Gasoline:storage:tank Assembly

One or both of the steel straps holding up the fuel tank and attaching it to the truck frame can corrode and fail (break or separate).If one strap fails, the tank may tilt and drop and possibly contact the road surface.If both straps break, the entire tank may drop to the road.If either failure occurs while the vehicle is being driven, contact with the road can abrade the tank and create a hole from which gasoline can spill.When the tank drops, it remains attached to the vehicle only by the fuel filler hose and/or supply lines, or in rare instances, by the skid plate, if present.In some cases the weight of the tank sufficiently strained the hoses and fittings and caused separation and subsequent fuel leaks from those connections.The fire hazard created by leaking gasoline is increased by the possible presence of sparks created by the metal tank being dragged along the road.Corrosion of the straps appears to be caused by prolonged exposure to road deicers, frequently road salt, used to treat snow or ice covered roads.States in which large quantities of deicers are applied to roads during the winter season (salt belt states) account for the predominant portion of strap failures.Vehicles in these salt belt states are prone to experience corrosion related failures more frequently and earlier in a vehicle?s life cycle.Ford reports approximately 97 percent of reports it received relating to strap failure involve vehicles that were operated in these high corrosion areas, and 95 percent of the reports to NHTSA involved such vehicles.Approximately one-third of F-150 U.S. production was sold in salt belt states.ODI has included in the above counts reports it has received from consumers and reports it has received from Ford in which either the complaint involved confirmed strap corrosion or ODI's assessment of available information suggests corrosion caused the reported problem.Among the incidents reported to NHTSA, 441 involved one or both straps failing due to corrosion, 353 involved the fuel tank dropping and/or dragging on the ground, and 180 involved fuel leakage.ODI has received four reports of strap failure in which the leaking fuel ignited but self-extinguished, and one incident in which fire destroyed the vehicle and injured its driver.Ford reported the same injury incident and three other unique fire incidents, including two in which the leaking fuel ignited and fire destroyed the vehicle.There were no injuries associated with the three unique Ford incidents.Ford has agreed to conduct a recall to repair the subject vehicles.The recall will cover vehicles that were originally sold or are currently registered in salt belt states (regardless of vehicle age).The vehiclesincluded in the recall are those subject vehicles that are, or have ever been, registered in Connecticut, Delaware, Iowa, Illinois, Indiana, Kentucky, Maine, Maryland, Massachusetts, Michigan, Minnesota, Missouri, New Hampshire, New Jersey, New York, Ohio, Pennsylvania, Rhode Island, Vermont, West Virginia, Wisconsin, or the District of Columbia.Ford's recall action appears to adequately address the problem at this time.The above vehicle population (1,340,349) includes subject vehicles originally delivered or sold in salt belt states.ODI does not know the current or historical locations of all subject vehicles.According to Ford approximately 73% of the recall population is currently registered (a 27% attrition rate).Ford is also recalling certain MY 1997-1999 F-250 vehicles (under 8,500 GVWR), and MY2002-2003 Lincoln Blackwood vehicles for the same condition, resulting in an estimated 1.1 million total vehicles

Fuel System, Gasoline:storage:tank Assembly:mounting

One or both of the steel straps holding up the fuel tank and attaching it to the truck frame can corrode and fail (break or separate).If one strap fails, the tank may tilt and drop and possibly contact the road surface.If both straps break, the entire tank may drop to the road.If either failure occurs while the vehicle is being driven, contact with the road can abrade the tank and create a hole from which gasoline can spill.When the tank drops, it remains attached to the vehicle only by the fuel filler hose and/or supply lines, or in rare instances, by the skid plate, if present.In some cases the weight of the tank sufficiently strained the hoses and fittings and caused separation and subsequent fuel leaks from those connections.The fire hazard created by leaking gasoline is increased by the possible presence of sparks created by the metal tank being dragged along the road.Corrosion of the straps appears to be caused by prolonged exposure to road deicers, frequently road salt, used to treat snow or ice covered roads.States in which large quantities of deicers are applied to roads during the winter season (salt belt states) account for the predominant portion of strap failures.Vehicles in these salt belt states are prone to experience corrosion related failures more frequently and earlier in a vehicle?s life cycle.Ford reports approximately 97 percent of reports it received relating to strap failure involve vehicles that were operated in these high corrosion areas, and 95 percent of the reports to NHTSA involved such vehicles.Approximately one-third of F-150 U.S. production was sold in salt belt states.ODI has included in the above counts reports it has received from consumers and reports it has received from Ford in which either the complaint involved confirmed strap corrosion or ODI's assessment of available information suggests corrosion caused the reported problem.Among the incidents reported to NHTSA, 441 involved one or both straps failing due to corrosion, 353 involved the fuel tank dropping and/or dragging on the ground, and 180 involved fuel leakage.ODI has received four reports of strap failure in which the leaking fuel ignited but self-extinguished, and one incident in which fire destroyed the vehicle and injured its driver.Ford reported the same injury incident and three other unique fire incidents, including two in which the leaking fuel ignited and fire destroyed the vehicle.There were no injuries associated with the three unique Ford incidents.Ford has agreed to conduct a recall to repair the subject vehicles.The recall will cover vehicles that were originally sold or are currently registered in salt belt states (regardless of vehicle age).The vehiclesincluded in the recall are those subject vehicles that are, or have ever been, registered in Connecticut, Delaware, Iowa, Illinois, Indiana, Kentucky, Maine, Maryland, Massachusetts, Michigan, Minnesota, Missouri, New Hampshire, New Jersey, New York, Ohio, Pennsylvania, Rhode Island, Vermont, West Virginia, Wisconsin, or the District of Columbia.Ford's recall action appears to adequately address the problem at this time.The above vehicle population (1,340,349) includes subject vehicles originally delivered or sold in salt belt states.ODI does not know the current or historical locations of all subject vehicles.According to Ford approximately 73% of the recall population is currently registered (a 27% attrition rate).Ford is also recalling certain MY 1997-1999 F-250 vehicles (under 8,500 GVWR), and MY2002-2003 Lincoln Blackwood vehicles for the same condition, resulting in an estimated 1.1 million total vehicles

Fuel System, Other:storage:tank Assembly

One or both of the steel straps holding up the fuel tank and attaching it to the truck frame can corrode and fail (break or separate).If one strap fails, the tank may tilt and drop and possibly contact the road surface.If both straps break, the entire tank may drop to the road.If either failure occurs while the vehicle is being driven, contact with the road can abrade the tank and create a hole from which gasoline can spill.When the tank drops, it remains attached to the vehicle only by the fuel filler hose and/or supply lines, or in rare instances, by the skid plate, if present.In some cases the weight of the tank sufficiently strained the hoses and fittings and caused separation and subsequent fuel leaks from those connections.The fire hazard created by leaking gasoline is increased by the possible presence of sparks created by the metal tank being dragged along the road.Corrosion of the straps appears to be caused by prolonged exposure to road deicers, frequently road salt, used to treat snow or ice covered roads.States in which large quantities of deicers are applied to roads during the winter season (salt belt states) account for the predominant portion of strap failures.Vehicles in these salt belt states are prone to experience corrosion related failures more frequently and earlier in a vehicle?s life cycle.Ford reports approximately 97 percent of reports it received relating to strap failure involve vehicles that were operated in these high corrosion areas, and 95 percent of the reports to NHTSA involved such vehicles.Approximately one-third of F-150 U.S. production was sold in salt belt states.ODI has included in the above counts reports it has received from consumers and reports it has received from Ford in which either the complaint involved confirmed strap corrosion or ODI's assessment of available information suggests corrosion caused the reported problem.Among the incidents reported to NHTSA, 441 involved one or both straps failing due to corrosion, 353 involved the fuel tank dropping and/or dragging on the ground, and 180 involved fuel leakage.ODI has received four reports of strap failure in which the leaking fuel ignited but self-extinguished, and one incident in which fire destroyed the vehicle and injured its driver.Ford reported the same injury incident and three other unique fire incidents, including two in which the leaking fuel ignited and fire destroyed the vehicle.There were no injuries associated with the three unique Ford incidents.Ford has agreed to conduct a recall to repair the subject vehicles.The recall will cover vehicles that were originally sold or are currently registered in salt belt states (regardless of vehicle age).The vehiclesincluded in the recall are those subject vehicles that are, or have ever been, registered in Connecticut, Delaware, Iowa, Illinois, Indiana, Kentucky, Maine, Maryland, Massachusetts, Michigan, Minnesota, Missouri, New Hampshire, New Jersey, New York, Ohio, Pennsylvania, Rhode Island, Vermont, West Virginia, Wisconsin, or the District of Columbia.Ford's recall action appears to adequately address the problem at this time.The above vehicle population (1,340,349) includes subject vehicles originally delivered or sold in salt belt states.ODI does not know the current or historical locations of all subject vehicles.According to Ford approximately 73% of the recall population is currently registered (a 27% attrition rate).Ford is also recalling certain MY 1997-1999 F-250 vehicles (under 8,500 GVWR), and MY2002-2003 Lincoln Blackwood vehicles for the same condition, resulting in an estimated 1.1 million total vehicles

Fuel System, Other:storage:tank Assembly:mounting

One or both of the steel straps holding up the fuel tank and attaching it to the truck frame can corrode and fail (break or separate).If one strap fails, the tank may tilt and drop and possibly contact the road surface.If both straps break, the entire tank may drop to the road.If either failure occurs while the vehicle is being driven, contact with the road can abrade the tank and create a hole from which gasoline can spill.When the tank drops, it remains attached to the vehicle only by the fuel filler hose and/or supply lines, or in rare instances, by the skid plate, if present.In some cases the weight of the tank sufficiently strained the hoses and fittings and caused separation and subsequent fuel leaks from those connections.The fire hazard created by leaking gasoline is increased by the possible presence of sparks created by the metal tank being dragged along the road.Corrosion of the straps appears to be caused by prolonged exposure to road deicers, frequently road salt, used to treat snow or ice covered roads.States in which large quantities of deicers are applied to roads during the winter season (salt belt states) account for the predominant portion of strap failures.Vehicles in these salt belt states are prone to experience corrosion related failures more frequently and earlier in a vehicle?s life cycle.Ford reports approximately 97 percent of reports it received relating to strap failure involve vehicles that were operated in these high corrosion areas, and 95 percent of the reports to NHTSA involved such vehicles.Approximately one-third of F-150 U.S. production was sold in salt belt states.ODI has included in the above counts reports it has received from consumers and reports it has received from Ford in which either the complaint involved confirmed strap corrosion or ODI's assessment of available information suggests corrosion caused the reported problem.Among the incidents reported to NHTSA, 441 involved one or both straps failing due to corrosion, 353 involved the fuel tank dropping and/or dragging on the ground, and 180 involved fuel leakage.ODI has received four reports of strap failure in which the leaking fuel ignited but self-extinguished, and one incident in which fire destroyed the vehicle and injured its driver.Ford reported the same injury incident and three other unique fire incidents, including two in which the leaking fuel ignited and fire destroyed the vehicle.There were no injuries associated with the three unique Ford incidents.Ford has agreed to conduct a recall to repair the subject vehicles.The recall will cover vehicles that were originally sold or are currently registered in salt belt states (regardless of vehicle age).The vehiclesincluded in the recall are those subject vehicles that are, or have ever been, registered in Connecticut, Delaware, Iowa, Illinois, Indiana, Kentucky, Maine, Maryland, Massachusetts, Michigan, Minnesota, Missouri, New Hampshire, New Jersey, New York, Ohio, Pennsylvania, Rhode Island, Vermont, West Virginia, Wisconsin, or the District of Columbia.Ford's recall action appears to adequately address the problem at this time.The above vehicle population (1,340,349) includes subject vehicles originally delivered or sold in salt belt states.ODI does not know the current or historical locations of all subject vehicles.According to Ford approximately 73% of the recall population is currently registered (a 27% attrition rate).Ford is also recalling certain MY 1997-1999 F-250 vehicles (under 8,500 GVWR), and MY2002-2003 Lincoln Blackwood vehicles for the same condition, resulting in an estimated 1.1 million total vehicles

EA10001 · Inadvertent Airbag Deployment

Opened Jan 13, 2010 · Closed Apr 25, 2011

Status: closed (inferred from source dates) · Air Bags; Air Bags:frontal; Air Bags:frontal:driver Side:inflator Module; Air Bags:frontal:sensor/control MODULE-INACTIVE

ODI opened this investigation based on reports of inadvertent airbag deployment.Data provided by Ford indicated that the airbag clockspring jumper wire, which is situated inside the steering wheel assembly, was installed in a manner that would allow it to rub (abrade) against a sharp metal edge on the nearby horn plate.Because the horn plate is electrically grounded the abrasion of an airbag wire on the sharp edge could cause a short circuit condition.As a result the airbag light may illuminate and/or the airbag may inadvertently deploy.Inadvertent deployments are most likely to occur during the airbag system's self-diagnostic test that initiates when the ignition switch is turned on.Ford modified the vehicle design in late January 2006 adding a protective tape over the sharp metal edge of the horn plate.Ford made additional design changes on MY 2007 vehicles to the horn plate, the clockspring jumper, and the connector layouts to further address this issue.ODI identified 318 deployment incidents with 121 alleged injury reports from subject vehicles.All but one of the incident and injury reports occurred in vehicles built before the January 2006 modification.In addition, there was one incident and alleged injury reported in the MY 2006 Mark LT vehicles that share the same design. In letters dated February 21 and April 11, 2011, Ford announced a recall of all of the approximately 1.3 million MY 2004-2006 F-150 vehicles built prior to January 24, 2006, the date the initial vehicle modification was made.In addition, approximately 14,000 MY 2006 Mark LT vehicles built prior to January 24, 2006 will also be recalled.Vehicles built after that date, which contain the modification, are not within the recall scope.Accordingly the investigation is closed.

Additional source detail variants (4)

Air Bags

ODI opened this investigation based on reports of inadvertent airbag deployment.Data provided by Ford indicated that the airbag clockspring jumper wire, which is situated inside the steering wheel assembly, was installed in a manner that would allow it to rub (abrade) against a sharp metal edge on the nearby horn plate.Because the horn plate is electrically grounded the abrasion of an airbag wire on the sharp edge could cause a short circuit condition.As a result the airbag light may illuminate and/or the airbag may inadvertently deploy.Inadvertent deployments are most likely to occur during the airbag system's self-diagnostic test that initiates when the ignition switch is turned on.Ford modified the vehicle design in late January 2006 adding a protective tape over the sharp metal edge of the horn plate.Ford made additional design changes on MY 2007 vehicles to the horn plate, the clockspring jumper, and the connector layouts to further address this issue.ODI identified 318 deployment incidents with 121 alleged injury reports from subject vehicles.All but one of the incident and injury reports occurred in vehicles built before the January 2006 modification.In addition, there was one incident and alleged injury reported in the MY 2006 Mark LT vehicles that share the same design. In letters dated February 21 and April 11, 2011, Ford announced a recall of all of the approximately 1.3 million MY 2004-2006 F-150 vehicles built prior to January 24, 2006, the date the initial vehicle modification was made.In addition, approximately 14,000 MY 2006 Mark LT vehicles built prior to January 24, 2006 will also be recalled.Vehicles built after that date, which contain the modification, are not within the recall scope.Accordingly the investigation is closed.

Air Bags:frontal:driver Side:inflator Module

ODI opened this investigation based on reports of inadvertent airbag deployment.Data provided by Ford indicated that the airbag clockspring jumper wire, which is situated inside the steering wheel assembly, was installed in a manner that would allow it to rub (abrade) against a sharp metal edge on the nearby horn plate.Because the horn plate is electrically grounded the abrasion of an airbag wire on the sharp edge could cause a short circuit condition.As a result the airbag light may illuminate and/or the airbag may inadvertently deploy.Inadvertent deployments are most likely to occur during the airbag system's self-diagnostic test that initiates when the ignition switch is turned on.Ford modified the vehicle design in late January 2006 adding a protective tape over the sharp metal edge of the horn plate.Ford made additional design changes on MY 2007 vehicles to the horn plate, the clockspring jumper, and the connector layouts to further address this issue.ODI identified 318 deployment incidents with 121 alleged injury reports from subject vehicles.All but one of the incident and injury reports occurred in vehicles built before the January 2006 modification.In addition, there was one incident and alleged injury reported in the MY 2006 Mark LT vehicles that share the same design. In letters dated February 21 and April 11, 2011, Ford announced a recall of all of the approximately 1.3 million MY 2004-2006 F-150 vehicles built prior to January 24, 2006, the date the initial vehicle modification was made.In addition, approximately 14,000 MY 2006 Mark LT vehicles built prior to January 24, 2006 will also be recalled.Vehicles built after that date, which contain the modification, are not within the recall scope.Accordingly the investigation is closed.

Air Bags:frontal

ODI opened this investigation based on reports of inadvertent airbag deployment.Data provided by Ford indicated that the airbag clockspring jumper wire, which is situated inside the steering wheel assembly, was installed in a manner that would allow it to rub (abrade) against a sharp metal edge on the nearby horn plate.Because the horn plate is electrically grounded the abrasion of an airbag wire on the sharp edge could cause a short circuit condition.As a result the airbag light may illuminate and/or the airbag may inadvertently deploy.Inadvertent deployments are most likely to occur during the airbag system's self-diagnostic test that initiates when the ignition switch is turned on.Ford modified the vehicle design in late January 2006 adding a protective tape over the sharp metal edge of the horn plate.Ford made additional design changes on MY 2007 vehicles to the horn plate, the clockspring jumper, and the connector layouts to further address this issue.ODI identified 318 deployment incidents with 121 alleged injury reports from subject vehicles.All but one of the incident and injury reports occurred in vehicles built before the January 2006 modification.In addition, there was one incident and alleged injury reported in the MY 2006 Mark LT vehicles that share the same design. In letters dated February 21 and April 11, 2011, Ford announced a recall of all of the approximately 1.3 million MY 2004-2006 F-150 vehicles built prior to January 24, 2006, the date the initial vehicle modification was made.In addition, approximately 14,000 MY 2006 Mark LT vehicles built prior to January 24, 2006 will also be recalled.Vehicles built after that date, which contain the modification, are not within the recall scope.Accordingly the investigation is closed.

Air Bags:frontal:sensor/control MODULE-INACTIVE

ODI opened this investigation based on reports of inadvertent airbag deployment.Data provided by Ford indicated that the airbag clockspring jumper wire, which is situated inside the steering wheel assembly, was installed in a manner that would allow it to rub (abrade) against a sharp metal edge on the nearby horn plate.Because the horn plate is electrically grounded the abrasion of an airbag wire on the sharp edge could cause a short circuit condition.As a result the airbag light may illuminate and/or the airbag may inadvertently deploy.Inadvertent deployments are most likely to occur during the airbag system's self-diagnostic test that initiates when the ignition switch is turned on.Ford modified the vehicle design in late January 2006 adding a protective tape over the sharp metal edge of the horn plate.Ford made additional design changes on MY 2007 vehicles to the horn plate, the clockspring jumper, and the connector layouts to further address this issue.ODI identified 318 deployment incidents with 121 alleged injury reports from subject vehicles.All but one of the incident and injury reports occurred in vehicles built before the January 2006 modification.In addition, there was one incident and alleged injury reported in the MY 2006 Mark LT vehicles that share the same design. In letters dated February 21 and April 11, 2011, Ford announced a recall of all of the approximately 1.3 million MY 2004-2006 F-150 vehicles built prior to January 24, 2006, the date the initial vehicle modification was made.In addition, approximately 14,000 MY 2006 Mark LT vehicles built prior to January 24, 2006 will also be recalled.Vehicles built after that date, which contain the modification, are not within the recall scope.Accordingly the investigation is closed.

PE08063 · Cng Regulator Leak

Opened Oct 31, 2008 · Closed Feb 27, 2009

Status: closed (inferred from source dates) · Fuel System, Other; Fuel System, Other:delivery; Fuel System, Other:delivery:hoses, Lines/piping, And Fittings; Fuel System, Other:fuel Injection System

THE AGENCY HAS CLOSED THIS INVESTIGATION BASED ON ITS REVIEW OF COMPLAINT REPORTS, DISCUSSIONS WITH COMPLAINANTS AND FIELD AND TECHNICAL DATA PROVIDED BY FORD.THE SUBJECT VEHICLES ARE 1/2 TON PICKUP TRUCKS AND ARE NATURAL GAS VEHICLES (NGV) THAT ARE FUELED BY GASOLINE OR COMPRESSED NATURAL GAS.THE AGENCY HAS RECEIVED REPORTS ALLEGING IMPROPER OPERATION OF THE NATURAL GAS FUEL PRESSURE REGULATOR ALLOWING RELEASE OF EXCESS AMOUNTS OF NATURAL GAS INTO THE ENGINE COMPARTMENT.FORD REPORTS THAT THE REGULATOR CONTAINS AN OVER PRESSURE RELIEF VALVE THAT WILL VENT NATURAL GAS SHOULD THE PRESSURE EXCEED A SET THRESHOLD.THE COMPLAINT REPORTS AND DATA REVIEWED BY THE AGENCY INDICATE THAT AN IMPROPERLY OPERATING PRESSURE REGULATOR CAN RESULT IN AN OVERPRESSURE CONDITION AND ACTIVATE THE REGULATOR PRESSURE RELIEF VALVE.THE RELEASED NATURAL GAS IS DIRECTED THROUGH A VENT HOSE THAT DISCHARGES THE NATURAL GAS IN THE VICINITY OF THE RIGHT FRONT WHEEL HOUSE AND AWAY FROM THE ENGINE COMPARTMENT'S EXTREMELY HOT AREAS/SURFACES.OWNERS ARE NORMALLY AWARE OF THIS PROBLEM BY THE PRESENCE OF AN ILLUMINATED WARNING LIGHT INSIDE THE VEHICLE, ODOR OF NATURAL GAS OR THE SOUND OF VENTING GAS.WHEN THE OPERATOR TURNS THE ENGINE OFF, THE NATURAL GAS SUPPLY TANK SOLENOID WILL CLOSE AND THE REGULATOR WILL NOT RELEASE NATURAL GAS.AT VEHICLE RESTART, THE SOLENOID VALVE WILL REMAIN CLOSED TO PREVENT LEAKAGE AND THE VEHICLE WILL ONLY OPERATE IN THE GASOLINE MODE.A SAFETY-RELATED DEFECT HAS NOT BEEN IDENTIFIED AT THIS TIME AND FURTHER USE OF AGENCY RESOURCES DOES NOT APPEAR TO BE WARRANTED.ACCORDINGLY, THIS INVESTIGATION IS CLOSED.THE CLOSING OF THIS INVESTIGATION DOES NOT CONSTITUTE A FINDING BY NHTSA THAT A SAFETY-RELATED DEFECT DOES NOT EXIST.THE AGENCY WILL MONITOR THIS ISSUE AND RESERVES THE RIGHT TO TAKE FURTHER ACTION IF WARRANTED BY THE CIRCUMSTANCES.

Additional source detail variants (4)

Fuel System, Other:delivery

THE AGENCY HAS CLOSED THIS INVESTIGATION BASED ON ITS REVIEW OF COMPLAINT REPORTS, DISCUSSIONS WITH COMPLAINANTS AND FIELD AND TECHNICAL DATA PROVIDED BY FORD.THE SUBJECT VEHICLES ARE 1/2 TON PICKUP TRUCKS AND ARE NATURAL GAS VEHICLES (NGV) THAT ARE FUELED BY GASOLINE OR COMPRESSED NATURAL GAS.THE AGENCY HAS RECEIVED REPORTS ALLEGING IMPROPER OPERATION OF THE NATURAL GAS FUEL PRESSURE REGULATOR ALLOWING RELEASE OF EXCESS AMOUNTS OF NATURAL GAS INTO THE ENGINE COMPARTMENT.FORD REPORTS THAT THE REGULATOR CONTAINS AN OVER PRESSURE RELIEF VALVE THAT WILL VENT NATURAL GAS SHOULD THE PRESSURE EXCEED A SET THRESHOLD.THE COMPLAINT REPORTS AND DATA REVIEWED BY THE AGENCY INDICATE THAT AN IMPROPERLY OPERATING PRESSURE REGULATOR CAN RESULT IN AN OVERPRESSURE CONDITION AND ACTIVATE THE REGULATOR PRESSURE RELIEF VALVE.THE RELEASED NATURAL GAS IS DIRECTED THROUGH A VENT HOSE THAT DISCHARGES THE NATURAL GAS IN THE VICINITY OF THE RIGHT FRONT WHEEL HOUSE AND AWAY FROM THE ENGINE COMPARTMENT'S EXTREMELY HOT AREAS/SURFACES.OWNERS ARE NORMALLY AWARE OF THIS PROBLEM BY THE PRESENCE OF AN ILLUMINATED WARNING LIGHT INSIDE THE VEHICLE, ODOR OF NATURAL GAS OR THE SOUND OF VENTING GAS.WHEN THE OPERATOR TURNS THE ENGINE OFF, THE NATURAL GAS SUPPLY TANK SOLENOID WILL CLOSE AND THE REGULATOR WILL NOT RELEASE NATURAL GAS.AT VEHICLE RESTART, THE SOLENOID VALVE WILL REMAIN CLOSED TO PREVENT LEAKAGE AND THE VEHICLE WILL ONLY OPERATE IN THE GASOLINE MODE.A SAFETY-RELATED DEFECT HAS NOT BEEN IDENTIFIED AT THIS TIME AND FURTHER USE OF AGENCY RESOURCES DOES NOT APPEAR TO BE WARRANTED.ACCORDINGLY, THIS INVESTIGATION IS CLOSED.THE CLOSING OF THIS INVESTIGATION DOES NOT CONSTITUTE A FINDING BY NHTSA THAT A SAFETY-RELATED DEFECT DOES NOT EXIST.THE AGENCY WILL MONITOR THIS ISSUE AND RESERVES THE RIGHT TO TAKE FURTHER ACTION IF WARRANTED BY THE CIRCUMSTANCES.

Fuel System, Other:delivery:hoses, Lines/piping, And Fittings

THE AGENCY HAS CLOSED THIS INVESTIGATION BASED ON ITS REVIEW OF COMPLAINT REPORTS, DISCUSSIONS WITH COMPLAINANTS AND FIELD AND TECHNICAL DATA PROVIDED BY FORD.THE SUBJECT VEHICLES ARE 1/2 TON PICKUP TRUCKS AND ARE NATURAL GAS VEHICLES (NGV) THAT ARE FUELED BY GASOLINE OR COMPRESSED NATURAL GAS.THE AGENCY HAS RECEIVED REPORTS ALLEGING IMPROPER OPERATION OF THE NATURAL GAS FUEL PRESSURE REGULATOR ALLOWING RELEASE OF EXCESS AMOUNTS OF NATURAL GAS INTO THE ENGINE COMPARTMENT.FORD REPORTS THAT THE REGULATOR CONTAINS AN OVER PRESSURE RELIEF VALVE THAT WILL VENT NATURAL GAS SHOULD THE PRESSURE EXCEED A SET THRESHOLD.THE COMPLAINT REPORTS AND DATA REVIEWED BY THE AGENCY INDICATE THAT AN IMPROPERLY OPERATING PRESSURE REGULATOR CAN RESULT IN AN OVERPRESSURE CONDITION AND ACTIVATE THE REGULATOR PRESSURE RELIEF VALVE.THE RELEASED NATURAL GAS IS DIRECTED THROUGH A VENT HOSE THAT DISCHARGES THE NATURAL GAS IN THE VICINITY OF THE RIGHT FRONT WHEEL HOUSE AND AWAY FROM THE ENGINE COMPARTMENT'S EXTREMELY HOT AREAS/SURFACES.OWNERS ARE NORMALLY AWARE OF THIS PROBLEM BY THE PRESENCE OF AN ILLUMINATED WARNING LIGHT INSIDE THE VEHICLE, ODOR OF NATURAL GAS OR THE SOUND OF VENTING GAS.WHEN THE OPERATOR TURNS THE ENGINE OFF, THE NATURAL GAS SUPPLY TANK SOLENOID WILL CLOSE AND THE REGULATOR WILL NOT RELEASE NATURAL GAS.AT VEHICLE RESTART, THE SOLENOID VALVE WILL REMAIN CLOSED TO PREVENT LEAKAGE AND THE VEHICLE WILL ONLY OPERATE IN THE GASOLINE MODE.A SAFETY-RELATED DEFECT HAS NOT BEEN IDENTIFIED AT THIS TIME AND FURTHER USE OF AGENCY RESOURCES DOES NOT APPEAR TO BE WARRANTED.ACCORDINGLY, THIS INVESTIGATION IS CLOSED.THE CLOSING OF THIS INVESTIGATION DOES NOT CONSTITUTE A FINDING BY NHTSA THAT A SAFETY-RELATED DEFECT DOES NOT EXIST.THE AGENCY WILL MONITOR THIS ISSUE AND RESERVES THE RIGHT TO TAKE FURTHER ACTION IF WARRANTED BY THE CIRCUMSTANCES.

Fuel System, Other

THE AGENCY HAS CLOSED THIS INVESTIGATION BASED ON ITS REVIEW OF COMPLAINT REPORTS, DISCUSSIONS WITH COMPLAINANTS AND FIELD AND TECHNICAL DATA PROVIDED BY FORD.THE SUBJECT VEHICLES ARE 1/2 TON PICKUP TRUCKS AND ARE NATURAL GAS VEHICLES (NGV) THAT ARE FUELED BY GASOLINE OR COMPRESSED NATURAL GAS.THE AGENCY HAS RECEIVED REPORTS ALLEGING IMPROPER OPERATION OF THE NATURAL GAS FUEL PRESSURE REGULATOR ALLOWING RELEASE OF EXCESS AMOUNTS OF NATURAL GAS INTO THE ENGINE COMPARTMENT.FORD REPORTS THAT THE REGULATOR CONTAINS AN OVER PRESSURE RELIEF VALVE THAT WILL VENT NATURAL GAS SHOULD THE PRESSURE EXCEED A SET THRESHOLD.THE COMPLAINT REPORTS AND DATA REVIEWED BY THE AGENCY INDICATE THAT AN IMPROPERLY OPERATING PRESSURE REGULATOR CAN RESULT IN AN OVERPRESSURE CONDITION AND ACTIVATE THE REGULATOR PRESSURE RELIEF VALVE.THE RELEASED NATURAL GAS IS DIRECTED THROUGH A VENT HOSE THAT DISCHARGES THE NATURAL GAS IN THE VICINITY OF THE RIGHT FRONT WHEEL HOUSE AND AWAY FROM THE ENGINE COMPARTMENT'S EXTREMELY HOT AREAS/SURFACES.OWNERS ARE NORMALLY AWARE OF THIS PROBLEM BY THE PRESENCE OF AN ILLUMINATED WARNING LIGHT INSIDE THE VEHICLE, ODOR OF NATURAL GAS OR THE SOUND OF VENTING GAS.WHEN THE OPERATOR TURNS THE ENGINE OFF, THE NATURAL GAS SUPPLY TANK SOLENOID WILL CLOSE AND THE REGULATOR WILL NOT RELEASE NATURAL GAS.AT VEHICLE RESTART, THE SOLENOID VALVE WILL REMAIN CLOSED TO PREVENT LEAKAGE AND THE VEHICLE WILL ONLY OPERATE IN THE GASOLINE MODE.A SAFETY-RELATED DEFECT HAS NOT BEEN IDENTIFIED AT THIS TIME AND FURTHER USE OF AGENCY RESOURCES DOES NOT APPEAR TO BE WARRANTED.ACCORDINGLY, THIS INVESTIGATION IS CLOSED.THE CLOSING OF THIS INVESTIGATION DOES NOT CONSTITUTE A FINDING BY NHTSA THAT A SAFETY-RELATED DEFECT DOES NOT EXIST.THE AGENCY WILL MONITOR THIS ISSUE AND RESERVES THE RIGHT TO TAKE FURTHER ACTION IF WARRANTED BY THE CIRCUMSTANCES.

Fuel System, Other:fuel Injection System

THE AGENCY HAS CLOSED THIS INVESTIGATION BASED ON ITS REVIEW OF COMPLAINT REPORTS, DISCUSSIONS WITH COMPLAINANTS AND FIELD AND TECHNICAL DATA PROVIDED BY FORD.THE SUBJECT VEHICLES ARE 1/2 TON PICKUP TRUCKS AND ARE NATURAL GAS VEHICLES (NGV) THAT ARE FUELED BY GASOLINE OR COMPRESSED NATURAL GAS.THE AGENCY HAS RECEIVED REPORTS ALLEGING IMPROPER OPERATION OF THE NATURAL GAS FUEL PRESSURE REGULATOR ALLOWING RELEASE OF EXCESS AMOUNTS OF NATURAL GAS INTO THE ENGINE COMPARTMENT.FORD REPORTS THAT THE REGULATOR CONTAINS AN OVER PRESSURE RELIEF VALVE THAT WILL VENT NATURAL GAS SHOULD THE PRESSURE EXCEED A SET THRESHOLD.THE COMPLAINT REPORTS AND DATA REVIEWED BY THE AGENCY INDICATE THAT AN IMPROPERLY OPERATING PRESSURE REGULATOR CAN RESULT IN AN OVERPRESSURE CONDITION AND ACTIVATE THE REGULATOR PRESSURE RELIEF VALVE.THE RELEASED NATURAL GAS IS DIRECTED THROUGH A VENT HOSE THAT DISCHARGES THE NATURAL GAS IN THE VICINITY OF THE RIGHT FRONT WHEEL HOUSE AND AWAY FROM THE ENGINE COMPARTMENT'S EXTREMELY HOT AREAS/SURFACES.OWNERS ARE NORMALLY AWARE OF THIS PROBLEM BY THE PRESENCE OF AN ILLUMINATED WARNING LIGHT INSIDE THE VEHICLE, ODOR OF NATURAL GAS OR THE SOUND OF VENTING GAS.WHEN THE OPERATOR TURNS THE ENGINE OFF, THE NATURAL GAS SUPPLY TANK SOLENOID WILL CLOSE AND THE REGULATOR WILL NOT RELEASE NATURAL GAS.AT VEHICLE RESTART, THE SOLENOID VALVE WILL REMAIN CLOSED TO PREVENT LEAKAGE AND THE VEHICLE WILL ONLY OPERATE IN THE GASOLINE MODE.A SAFETY-RELATED DEFECT HAS NOT BEEN IDENTIFIED AT THIS TIME AND FURTHER USE OF AGENCY RESOURCES DOES NOT APPEAR TO BE WARRANTED.ACCORDINGLY, THIS INVESTIGATION IS CLOSED.THE CLOSING OF THIS INVESTIGATION DOES NOT CONSTITUTE A FINDING BY NHTSA THAT A SAFETY-RELATED DEFECT DOES NOT EXIST.THE AGENCY WILL MONITOR THIS ISSUE AND RESERVES THE RIGHT TO TAKE FURTHER ACTION IF WARRANTED BY THE CIRCUMSTANCES.

DP05005 · Spark Plug Ejection From Cylinder Head

Opened Sep 22, 2005 · Closed Jan 4, 2006

Status: closed (inferred from source dates) · Engine And Engine Cooling; Engine And Engine Cooling:engine; Engine And Engine Cooling:engine:gasoline

ON SEPTEMBER 6, 2005, ODI RECEIVED A PETITION REQUESTING THAT THE AGENCY INVESTIGATE ALLEGATIONS OF ENGINE SPARK PLUG EJECTION IN CERTAIN MODEL YEAR 1997 THROUGH 2004 FORD VEHICLES WITH TRITON V-8 AND V-10 ENGINES.ODI RECEIVED A TOTAL OF 474 NON-DUPLICATIVE COMPLAINTS ON THE SUBJECT VEHICLES WHERE THE COMPLAINANT, OR THE DEALER REPAIRING THE VEHICLE, REPORTED THAT A SPARK PLUG DETACHED FROM THE CYLINDER AND/OR EJECTED FROM THE ENGINE.AS OF DECEMBER 8, 2005, ODI IS NOT AWARE OF ANY ALLEGATIONS WHERE THE ALLEGED DEFECT RESULTED IN A LOSS OF VEHICLE CONTROL, A CRASH, AN INJURY, OR A FATALITY IN ANY OF THE 10,319,810 SUBJECT VEHICLES.IN ADDITION, ODI IS AWARE OF ONLY TWO INCIDENTS WHERE THE VEHICLE STALLED WITHOUT RESTART.INFORMATION CONTAINED IN THE ODI CONSUMER COMPLAINTS AND OBTAINED FROM 72 TELEPHONE INTERVIEWS WITH COMPLAINANTS SHOWED THE FOLLOWING:(1) 99% OF THE COMPLAINTS WERE ON MY 1997 TO 2002 SUBJECT VEHICLES.(2) MOST THE COMPLAINANTS REPORTED HEARING A LOUD POP WHILE DRIVING OR UPON STARTING UP THE VEHICLE FOLLOWED BY A LOUD, REPETITIVE CLICKING OR POPPING SOUND.(3) MANY OF THE COMPLAINANTS REPORTED THAT THE POPPING SOUND WAS ACCOMPANIED BY SOME LOSS OF VEHICLE POWER; HOWEVER, IN 99% OF THE INCIDENTS REPORTED, THE VEHICLE DID NOT STALL.IN THE VERY FEW INCIDENTS WHERE THE VEHICLE DID STALL, MOST VEHICLES COULD BE RESTARTED.(4) ONLY A SMALL PERCENTAGE OF THE COMPLAINANTS CITED THAT THEY SMELLED GAS OR A SLIGHT BURNING SMELL WHEN THE INCIDENT OCCURRED.(5) IN ALL BUT A VERY FEW INCIDENTS, VEHICLE DAMAGE WAS LIMITED TO THE ENGINE.IN ONE INCIDENT, THE COMPLAINT REPORTED THAT THE FUEL RAIL WAS DAMAGED AND REPLACED AFTER ONE OF THE SPARK PLUGS EJECTED FROM THE ENGINE; HOWEVER, THE COMPLAINANT REPORTED THAT THE DAMAGE DID NOT RESULT IN ANY TYPE OF FUEL LEAK OR FIRE.IN ANOTHER INCIDENT, THE ONLY INCIDENT WHERE A FIRE WAS ALLEGED, THE COMPLAINANT REPORTED THAT NO FLUID LEAK WAS OBSERVED, BUT THAT A FIRE RESULTED AFTER THE SPARK PLUG HAD EJECTED FROM THE ENGINE AND HE HAD RESTARTED THE VEHICLE AND DRIVEN TO ANOTHER LOCATION.NONE OF THE COMPLAINANTS REPORTED ANY DAMAGE TO THE VEHICLE HOOD.(6) ONLY TWO COMPLAINANTS REPORTED THAT THEY OBSERVED WHAT APPEARED TO BE SOME DROPS OF FUEL COMING FROM THE CYLINDER WHERE THE SPARK PLUG HAD FAILED OR ON THE SPARK PLUG ITSELF; HOWEVER, EACH OF THESE COMPLAINANTS REPORTED THAT THERE WAS NO SMOKE OR FLAMES AS A RESULT OF HIS INCIDENT.AS THE PETITIONER NOTED, AND ODI?S ANALYSIS SHOWED, IT IS POSSIBLE FOR A SPARK PLUG TO DETACH FROM THE ENGINE CYLINDER THREADS IN THE SUBJECT VEHICLES.HOWEVER, ODI?S ANALYSIS OF 474 COMPLAINTS DESCRIBING SUCH INCIDENTS FOUND ONLY A VERY FEW ALLEGED ANY SAFETY-RELATED CONSEQUENCES.NONE OF THESE SHOWED ANY EVIDENCE OF A SERIOUS SAFETY CONSEQUENCE.GIVEN THE LARGE POPULATION AND RELATIVELY LONG EXPOSURE TIME OF THE SUBJECT VEHICLES, THE COMPLAINT ANALYSIS INDICATES THAT THE RISK TO MOTOR VEHICLE SAFETY FROM THE ALLEGED DEFECT IS VERY LOW.IN VIEW OF THE FOREGOING, IT IS UNLIKELY THAT NHTSA WOULD ISSUE AN ORDER FOR THE NOTIFICATION AND REMEDY OF THE ALLEGED DEFECT AT THE CONCLUSION OF THE INVESTIGATION REQUESTED IN THE PETITION.THEREFORE, IN VIEW OF THE NEED TO ALLOCATE AND PRIORITIZE NHTSA?S LIMITED RESOURCES TO BEST ACCOMPLISH THE AGENCY?S SAFETY MISSION, THE PETITION IS DENIED.

Additional source detail variants (3)

Engine And Engine Cooling:engine

ON SEPTEMBER 6, 2005, ODI RECEIVED A PETITION REQUESTING THAT THE AGENCY INVESTIGATE ALLEGATIONS OF ENGINE SPARK PLUG EJECTION IN CERTAIN MODEL YEAR 1997 THROUGH 2004 FORD VEHICLES WITH TRITON V-8 AND V-10 ENGINES.ODI RECEIVED A TOTAL OF 474 NON-DUPLICATIVE COMPLAINTS ON THE SUBJECT VEHICLES WHERE THE COMPLAINANT, OR THE DEALER REPAIRING THE VEHICLE, REPORTED THAT A SPARK PLUG DETACHED FROM THE CYLINDER AND/OR EJECTED FROM THE ENGINE.AS OF DECEMBER 8, 2005, ODI IS NOT AWARE OF ANY ALLEGATIONS WHERE THE ALLEGED DEFECT RESULTED IN A LOSS OF VEHICLE CONTROL, A CRASH, AN INJURY, OR A FATALITY IN ANY OF THE 10,319,810 SUBJECT VEHICLES.IN ADDITION, ODI IS AWARE OF ONLY TWO INCIDENTS WHERE THE VEHICLE STALLED WITHOUT RESTART.INFORMATION CONTAINED IN THE ODI CONSUMER COMPLAINTS AND OBTAINED FROM 72 TELEPHONE INTERVIEWS WITH COMPLAINANTS SHOWED THE FOLLOWING:(1) 99% OF THE COMPLAINTS WERE ON MY 1997 TO 2002 SUBJECT VEHICLES.(2) MOST THE COMPLAINANTS REPORTED HEARING A LOUD POP WHILE DRIVING OR UPON STARTING UP THE VEHICLE FOLLOWED BY A LOUD, REPETITIVE CLICKING OR POPPING SOUND.(3) MANY OF THE COMPLAINANTS REPORTED THAT THE POPPING SOUND WAS ACCOMPANIED BY SOME LOSS OF VEHICLE POWER; HOWEVER, IN 99% OF THE INCIDENTS REPORTED, THE VEHICLE DID NOT STALL.IN THE VERY FEW INCIDENTS WHERE THE VEHICLE DID STALL, MOST VEHICLES COULD BE RESTARTED.(4) ONLY A SMALL PERCENTAGE OF THE COMPLAINANTS CITED THAT THEY SMELLED GAS OR A SLIGHT BURNING SMELL WHEN THE INCIDENT OCCURRED.(5) IN ALL BUT A VERY FEW INCIDENTS, VEHICLE DAMAGE WAS LIMITED TO THE ENGINE.IN ONE INCIDENT, THE COMPLAINT REPORTED THAT THE FUEL RAIL WAS DAMAGED AND REPLACED AFTER ONE OF THE SPARK PLUGS EJECTED FROM THE ENGINE; HOWEVER, THE COMPLAINANT REPORTED THAT THE DAMAGE DID NOT RESULT IN ANY TYPE OF FUEL LEAK OR FIRE.IN ANOTHER INCIDENT, THE ONLY INCIDENT WHERE A FIRE WAS ALLEGED, THE COMPLAINANT REPORTED THAT NO FLUID LEAK WAS OBSERVED, BUT THAT A FIRE RESULTED AFTER THE SPARK PLUG HAD EJECTED FROM THE ENGINE AND HE HAD RESTARTED THE VEHICLE AND DRIVEN TO ANOTHER LOCATION.NONE OF THE COMPLAINANTS REPORTED ANY DAMAGE TO THE VEHICLE HOOD.(6) ONLY TWO COMPLAINANTS REPORTED THAT THEY OBSERVED WHAT APPEARED TO BE SOME DROPS OF FUEL COMING FROM THE CYLINDER WHERE THE SPARK PLUG HAD FAILED OR ON THE SPARK PLUG ITSELF; HOWEVER, EACH OF THESE COMPLAINANTS REPORTED THAT THERE WAS NO SMOKE OR FLAMES AS A RESULT OF HIS INCIDENT.AS THE PETITIONER NOTED, AND ODI?S ANALYSIS SHOWED, IT IS POSSIBLE FOR A SPARK PLUG TO DETACH FROM THE ENGINE CYLINDER THREADS IN THE SUBJECT VEHICLES.HOWEVER, ODI?S ANALYSIS OF 474 COMPLAINTS DESCRIBING SUCH INCIDENTS FOUND ONLY A VERY FEW ALLEGED ANY SAFETY-RELATED CONSEQUENCES.NONE OF THESE SHOWED ANY EVIDENCE OF A SERIOUS SAFETY CONSEQUENCE.GIVEN THE LARGE POPULATION AND RELATIVELY LONG EXPOSURE TIME OF THE SUBJECT VEHICLES, THE COMPLAINT ANALYSIS INDICATES THAT THE RISK TO MOTOR VEHICLE SAFETY FROM THE ALLEGED DEFECT IS VERY LOW.IN VIEW OF THE FOREGOING, IT IS UNLIKELY THAT NHTSA WOULD ISSUE AN ORDER FOR THE NOTIFICATION AND REMEDY OF THE ALLEGED DEFECT AT THE CONCLUSION OF THE INVESTIGATION REQUESTED IN THE PETITION.THEREFORE, IN VIEW OF THE NEED TO ALLOCATE AND PRIORITIZE NHTSA?S LIMITED RESOURCES TO BEST ACCOMPLISH THE AGENCY?S SAFETY MISSION, THE PETITION IS DENIED.

Engine And Engine Cooling:engine:gasoline

ON SEPTEMBER 6, 2005, ODI RECEIVED A PETITION REQUESTING THAT THE AGENCY INVESTIGATE ALLEGATIONS OF ENGINE SPARK PLUG EJECTION IN CERTAIN MODEL YEAR 1997 THROUGH 2004 FORD VEHICLES WITH TRITON V-8 AND V-10 ENGINES.ODI RECEIVED A TOTAL OF 474 NON-DUPLICATIVE COMPLAINTS ON THE SUBJECT VEHICLES WHERE THE COMPLAINANT, OR THE DEALER REPAIRING THE VEHICLE, REPORTED THAT A SPARK PLUG DETACHED FROM THE CYLINDER AND/OR EJECTED FROM THE ENGINE.AS OF DECEMBER 8, 2005, ODI IS NOT AWARE OF ANY ALLEGATIONS WHERE THE ALLEGED DEFECT RESULTED IN A LOSS OF VEHICLE CONTROL, A CRASH, AN INJURY, OR A FATALITY IN ANY OF THE 10,319,810 SUBJECT VEHICLES.IN ADDITION, ODI IS AWARE OF ONLY TWO INCIDENTS WHERE THE VEHICLE STALLED WITHOUT RESTART.INFORMATION CONTAINED IN THE ODI CONSUMER COMPLAINTS AND OBTAINED FROM 72 TELEPHONE INTERVIEWS WITH COMPLAINANTS SHOWED THE FOLLOWING:(1) 99% OF THE COMPLAINTS WERE ON MY 1997 TO 2002 SUBJECT VEHICLES.(2) MOST THE COMPLAINANTS REPORTED HEARING A LOUD POP WHILE DRIVING OR UPON STARTING UP THE VEHICLE FOLLOWED BY A LOUD, REPETITIVE CLICKING OR POPPING SOUND.(3) MANY OF THE COMPLAINANTS REPORTED THAT THE POPPING SOUND WAS ACCOMPANIED BY SOME LOSS OF VEHICLE POWER; HOWEVER, IN 99% OF THE INCIDENTS REPORTED, THE VEHICLE DID NOT STALL.IN THE VERY FEW INCIDENTS WHERE THE VEHICLE DID STALL, MOST VEHICLES COULD BE RESTARTED.(4) ONLY A SMALL PERCENTAGE OF THE COMPLAINANTS CITED THAT THEY SMELLED GAS OR A SLIGHT BURNING SMELL WHEN THE INCIDENT OCCURRED.(5) IN ALL BUT A VERY FEW INCIDENTS, VEHICLE DAMAGE WAS LIMITED TO THE ENGINE.IN ONE INCIDENT, THE COMPLAINT REPORTED THAT THE FUEL RAIL WAS DAMAGED AND REPLACED AFTER ONE OF THE SPARK PLUGS EJECTED FROM THE ENGINE; HOWEVER, THE COMPLAINANT REPORTED THAT THE DAMAGE DID NOT RESULT IN ANY TYPE OF FUEL LEAK OR FIRE.IN ANOTHER INCIDENT, THE ONLY INCIDENT WHERE A FIRE WAS ALLEGED, THE COMPLAINANT REPORTED THAT NO FLUID LEAK WAS OBSERVED, BUT THAT A FIRE RESULTED AFTER THE SPARK PLUG HAD EJECTED FROM THE ENGINE AND HE HAD RESTARTED THE VEHICLE AND DRIVEN TO ANOTHER LOCATION.NONE OF THE COMPLAINANTS REPORTED ANY DAMAGE TO THE VEHICLE HOOD.(6) ONLY TWO COMPLAINANTS REPORTED THAT THEY OBSERVED WHAT APPEARED TO BE SOME DROPS OF FUEL COMING FROM THE CYLINDER WHERE THE SPARK PLUG HAD FAILED OR ON THE SPARK PLUG ITSELF; HOWEVER, EACH OF THESE COMPLAINANTS REPORTED THAT THERE WAS NO SMOKE OR FLAMES AS A RESULT OF HIS INCIDENT.AS THE PETITIONER NOTED, AND ODI?S ANALYSIS SHOWED, IT IS POSSIBLE FOR A SPARK PLUG TO DETACH FROM THE ENGINE CYLINDER THREADS IN THE SUBJECT VEHICLES.HOWEVER, ODI?S ANALYSIS OF 474 COMPLAINTS DESCRIBING SUCH INCIDENTS FOUND ONLY A VERY FEW ALLEGED ANY SAFETY-RELATED CONSEQUENCES.NONE OF THESE SHOWED ANY EVIDENCE OF A SERIOUS SAFETY CONSEQUENCE.GIVEN THE LARGE POPULATION AND RELATIVELY LONG EXPOSURE TIME OF THE SUBJECT VEHICLES, THE COMPLAINT ANALYSIS INDICATES THAT THE RISK TO MOTOR VEHICLE SAFETY FROM THE ALLEGED DEFECT IS VERY LOW.IN VIEW OF THE FOREGOING, IT IS UNLIKELY THAT NHTSA WOULD ISSUE AN ORDER FOR THE NOTIFICATION AND REMEDY OF THE ALLEGED DEFECT AT THE CONCLUSION OF THE INVESTIGATION REQUESTED IN THE PETITION.THEREFORE, IN VIEW OF THE NEED TO ALLOCATE AND PRIORITIZE NHTSA?S LIMITED RESOURCES TO BEST ACCOMPLISH THE AGENCY?S SAFETY MISSION, THE PETITION IS DENIED.

Engine And Engine Cooling

ON SEPTEMBER 6, 2005, ODI RECEIVED A PETITION REQUESTING THAT THE AGENCY INVESTIGATE ALLEGATIONS OF ENGINE SPARK PLUG EJECTION IN CERTAIN MODEL YEAR 1997 THROUGH 2004 FORD VEHICLES WITH TRITON V-8 AND V-10 ENGINES.ODI RECEIVED A TOTAL OF 474 NON-DUPLICATIVE COMPLAINTS ON THE SUBJECT VEHICLES WHERE THE COMPLAINANT, OR THE DEALER REPAIRING THE VEHICLE, REPORTED THAT A SPARK PLUG DETACHED FROM THE CYLINDER AND/OR EJECTED FROM THE ENGINE.AS OF DECEMBER 8, 2005, ODI IS NOT AWARE OF ANY ALLEGATIONS WHERE THE ALLEGED DEFECT RESULTED IN A LOSS OF VEHICLE CONTROL, A CRASH, AN INJURY, OR A FATALITY IN ANY OF THE 10,319,810 SUBJECT VEHICLES.IN ADDITION, ODI IS AWARE OF ONLY TWO INCIDENTS WHERE THE VEHICLE STALLED WITHOUT RESTART.INFORMATION CONTAINED IN THE ODI CONSUMER COMPLAINTS AND OBTAINED FROM 72 TELEPHONE INTERVIEWS WITH COMPLAINANTS SHOWED THE FOLLOWING:(1) 99% OF THE COMPLAINTS WERE ON MY 1997 TO 2002 SUBJECT VEHICLES.(2) MOST THE COMPLAINANTS REPORTED HEARING A LOUD POP WHILE DRIVING OR UPON STARTING UP THE VEHICLE FOLLOWED BY A LOUD, REPETITIVE CLICKING OR POPPING SOUND.(3) MANY OF THE COMPLAINANTS REPORTED THAT THE POPPING SOUND WAS ACCOMPANIED BY SOME LOSS OF VEHICLE POWER; HOWEVER, IN 99% OF THE INCIDENTS REPORTED, THE VEHICLE DID NOT STALL.IN THE VERY FEW INCIDENTS WHERE THE VEHICLE DID STALL, MOST VEHICLES COULD BE RESTARTED.(4) ONLY A SMALL PERCENTAGE OF THE COMPLAINANTS CITED THAT THEY SMELLED GAS OR A SLIGHT BURNING SMELL WHEN THE INCIDENT OCCURRED.(5) IN ALL BUT A VERY FEW INCIDENTS, VEHICLE DAMAGE WAS LIMITED TO THE ENGINE.IN ONE INCIDENT, THE COMPLAINT REPORTED THAT THE FUEL RAIL WAS DAMAGED AND REPLACED AFTER ONE OF THE SPARK PLUGS EJECTED FROM THE ENGINE; HOWEVER, THE COMPLAINANT REPORTED THAT THE DAMAGE DID NOT RESULT IN ANY TYPE OF FUEL LEAK OR FIRE.IN ANOTHER INCIDENT, THE ONLY INCIDENT WHERE A FIRE WAS ALLEGED, THE COMPLAINANT REPORTED THAT NO FLUID LEAK WAS OBSERVED, BUT THAT A FIRE RESULTED AFTER THE SPARK PLUG HAD EJECTED FROM THE ENGINE AND HE HAD RESTARTED THE VEHICLE AND DRIVEN TO ANOTHER LOCATION.NONE OF THE COMPLAINANTS REPORTED ANY DAMAGE TO THE VEHICLE HOOD.(6) ONLY TWO COMPLAINANTS REPORTED THAT THEY OBSERVED WHAT APPEARED TO BE SOME DROPS OF FUEL COMING FROM THE CYLINDER WHERE THE SPARK PLUG HAD FAILED OR ON THE SPARK PLUG ITSELF; HOWEVER, EACH OF THESE COMPLAINANTS REPORTED THAT THERE WAS NO SMOKE OR FLAMES AS A RESULT OF HIS INCIDENT.AS THE PETITIONER NOTED, AND ODI?S ANALYSIS SHOWED, IT IS POSSIBLE FOR A SPARK PLUG TO DETACH FROM THE ENGINE CYLINDER THREADS IN THE SUBJECT VEHICLES.HOWEVER, ODI?S ANALYSIS OF 474 COMPLAINTS DESCRIBING SUCH INCIDENTS FOUND ONLY A VERY FEW ALLEGED ANY SAFETY-RELATED CONSEQUENCES.NONE OF THESE SHOWED ANY EVIDENCE OF A SERIOUS SAFETY CONSEQUENCE.GIVEN THE LARGE POPULATION AND RELATIVELY LONG EXPOSURE TIME OF THE SUBJECT VEHICLES, THE COMPLAINT ANALYSIS INDICATES THAT THE RISK TO MOTOR VEHICLE SAFETY FROM THE ALLEGED DEFECT IS VERY LOW.IN VIEW OF THE FOREGOING, IT IS UNLIKELY THAT NHTSA WOULD ISSUE AN ORDER FOR THE NOTIFICATION AND REMEDY OF THE ALLEGED DEFECT AT THE CONCLUSION OF THE INVESTIGATION REQUESTED IN THE PETITION.THEREFORE, IN VIEW OF THE NEED TO ALLOCATE AND PRIORITIZE NHTSA?S LIMITED RESOURCES TO BEST ACCOMPLISH THE AGENCY?S SAFETY MISSION, THE PETITION IS DENIED.