NHTSA owner reports · September 18, 2026 snapshot.
What owners actually said
586 reportsMileage unknown · Mar 14, 2002
Fuel System, Gasoline
RECALL 93 V 125 000/FUEL TANK ASSENBLY: REPAIRS MADE BY THE DEALER :KRUSE'S STARK HICKY WEST FORD, DETROIT, MI; PHONE# 313/538-6600 WERE NOT CORRECTING THE PROBLEM, VEHICLE STILL LEAKING FROM REAR TANK. DEALER REFUSED TO ASSIST, STATING REPAIRS WERE COSTING TOO MUCH. MANUFACTURER WAS NOTIFIED. FEEL FREE TO PROVIDE ANY FURTHE…
Read full complaint
RECALL 93 V 125 000/FUEL TANK ASSENBLY: REPAIRS MADE BY THE DEALER :KRUSE'S STARK HICKY WEST FORD, DETROIT, MI; PHONE# 313/538-6600 WERE NOT CORRECTING THE PROBLEM, VEHICLE STILL LEAKING FROM REAR TANK. DEALER REFUSED TO ASSIST, STATING REPAIRS WERE COSTING TOO MUCH. MANUFACTURER WAS NOTIFIED. FEEL FREE TO PROVIDE ANY FURTHER INFORMATION.*AK
NHTSA ODI #8005698
Mileage unknown · Feb 15, 2002
Electrical SystemFire
WHILE TRAVELING, DASH LIGHT STARTED BLINKING OFF AND ON INTERMITTENTLY AND WITHOUT PRIOR WARING, CONSUMER NOTICED STEERING COLUMN WAS SMOKING, VEHICLE WAS ON FIRE. DEALERSHIP WAS AWARE OF PROBLEM.*AK CONSUMER STATES THAT ONE OF THE WIRES FOR THE OVERDRIVE LOCK OUT BUTTON ON THE END OF THE SHIFTER COLUMN HAD SHORTED OUT, START…
Read full complaint
WHILE TRAVELING, DASH LIGHT STARTED BLINKING OFF AND ON INTERMITTENTLY AND WITHOUT PRIOR WARING, CONSUMER NOTICED STEERING COLUMN WAS SMOKING, VEHICLE WAS ON FIRE. DEALERSHIP WAS AWARE OF PROBLEM.*AK CONSUMER STATES THAT ONE OF THE WIRES FOR THE OVERDRIVE LOCK OUT BUTTON ON THE END OF THE SHIFTER COLUMN HAD SHORTED OUT, STARTING A SMALL FIRE INSIDE THE STEERING COLUMN. *SLC
NHTSA ODI #8004141
Mileage unknown · Feb 8, 2002
Structure
THE RIGHT FRONT SIDE FRAME NEXT TO THE CONTROL ARM BRACKET HAS COMPLETELY RUSTED THROUGH AND BROKEN IN HALF RENDERING THE VEHICLE UNDRIVABLE. I HAVE HAD THE TRUCK TO THE DEALER (NOT THE DEARLER WHERE IT WAS PURCHASED IN 1995) FOR INSPECTION OF THE FRAME AND IT WAS DETERMINED THAT THE FRAME IS VERY THIN AND RUSTED ABOUT A FOOT ON…
Read full complaint
THE RIGHT FRONT SIDE FRAME NEXT TO THE CONTROL ARM BRACKET HAS COMPLETELY RUSTED THROUGH AND BROKEN IN HALF RENDERING THE VEHICLE UNDRIVABLE. I HAVE HAD THE TRUCK TO THE DEALER (NOT THE DEARLER WHERE IT WAS PURCHASED IN 1995) FOR INSPECTION OF THE FRAME AND IT WAS DETERMINED THAT THE FRAME IS VERY THIN AND RUSTED ABOUT A FOOT ON EACH SIDE OF THE BREAK. I HAVE FILED A COMPLAINT WITH FORD AND HAVE TALKED WITH THE SERVICE MANAGER AT PROGRESSIVE FORD TOM BYERS AND ALSO HIS FORD REP NANCY CROWE AND WAS TOLD THAT THE TRUCK WAS TOO OLD AND HAD TOO MANY MILES ON IT AND THEREFOR FORD WOULD NOT REPAIR IT. I EXPRESSED MY CONCERN THAT I FELT THIS WAS A SAFETY ISSUE AS IT INVOLVED THE MAIN STRUCTURE OF THE VEHICLE AND SHOULD NOT HAVE BROKEN AS IT HAS NEVER BEEN INVOLVED IN AN ACCIDENT OR BEEN ABUSED AND WAS TOLD BY NANCY THAT SHE DIDN'T CARE AS THE ORIGINAL FACTORY WARRENTY HAD LONG SINCE EXPIRED. I STATED THAT A TRUCK FRAME SHOULD LAST MORE THAN 9 YEARS WITHOUT DISINTEGRATING AND WAS AGAIN TOLD THERE WOULD BE NO COMPENSATION FROM FORD ON REPAIRS OR REPLACEMENT AND I WAS ALSO TOLD THAT THE TRUCK SHOULD NOT BE DRIVEN. I BELIEVE I AM NOT THE ONLY TRUCK OWNER WITH THIS PROBLEM AS I AM BEING TOLD BY NANCY CROWE.*AK
NHTSA ODI #757972
Mileage unknown · Jan 30, 2002
Engine And Engine Cooling
OIL WAS LEAKING FROM THE ENGINE COMPARTMENT. DEALER WAS CONTACTED, AND STATED OIL PAN WAS RUSTED FROM INSIDE, CAUSING THE OIL PAN TO LEAK. PLEASE PROVIDE FURTHER DETAILS.*AK
NHTSA ODI #8003216
Mileage unknown · Jan 30, 2002
Fuel System, Gasoline
FUEL TANK IS LEAKING INTO SECOND FUEL TANK. CONSUMER TOOK VEHICLE INTO THE DEALER FOR RECALL 93-V-125-000 REPAIRS, BUT REPAIRS DID NOT WORK. PROBLEM STILL OCCURS. *AK CONSUMER STATES REAR TANK LEAKS INTO FRONT TANK WHILE FRONT TANK WAS IN USE. THE PROBLEM WAS GETTING WORSE. *YH
NHTSA ODI #8003204
Mileage unknown · Jan 23, 2002
Fuel System, Gasoline
CONSUMER STATED HE RECEIVED SAFETY RECALL NOTICE 00V-424 TO REPLACE CARBON STEEL FUEL PRESSURE REGULATOR ON JULY 11, 2001, BUT DEALER HAS YET TO PERFORM RECALL REPAIRS, WHEN CONSUMER ASKED ABOUT THE RECALL REPAIRS, DEALER STATED THAT THEY DO NOT HAVE PARTS YET. *TT
NHTSA ODI #564076
Mileage unknown · Jan 22, 2002
Engine And Engine CoolingSuspension
SHACKELS ON REAR LEAF SPRINGS ARE RUSTED THROUGH. VEHICLE NOT TAKEN TO DEALER YET.*AK THE OIL PAN HAD RUST FROM OUTSIDE AND WAS LEAKING OIL. THE CONSUMER REPLACED IT AT HIS EXPENSE. *YH
NHTSA ODI #8002595
Mileage unknown · Jan 11, 2002
Engine And Engine Cooling
CONSUMER STATED OIL WAS LEAKING OUT OF OIL PAN WHICH HAD RUSTED, THIS CAUSED OIL PAN GASKET TO BLOWOUT.*AK CONSUMER STATED VEHICLE WAS TOWED, BUT HAS NOT BEEN FIXED.*SLC
NHTSA ODI #8002007
Mileage unknown · Jan 10, 2002
Seat BeltsSeatsCrashInjury
WHILE STOPPED AT A LIGHT, WE WERE REAR-ENDED BY A 1984 CHEVROLET VAN. BOTH PARTIES IN THE TRUCK WERE WEARING A SEATBELT AT TIME OF ACCIDENT. BOTH FRONT 50/50 BENCH SEAT BACKS, ONLY ALLOWED TO FUNCTION LIFTING FORWARD, COLLAPSED BACKWARDS. THIS CAUSED TWO PASSENGERS TO FALL BACKWARDS TO THE EXT. CAB PORTION OF THE TRUCK, WHERE N…
Read full complaint
WHILE STOPPED AT A LIGHT, WE WERE REAR-ENDED BY A 1984 CHEVROLET VAN. BOTH PARTIES IN THE TRUCK WERE WEARING A SEATBELT AT TIME OF ACCIDENT. BOTH FRONT 50/50 BENCH SEAT BACKS, ONLY ALLOWED TO FUNCTION LIFTING FORWARD, COLLAPSED BACKWARDS. THIS CAUSED TWO PASSENGERS TO FALL BACKWARDS TO THE EXT. CAB PORTION OF THE TRUCK, WHERE NORMALLY OUR KIDS SIT. AT ONLY 6'0" TALL, MY HUSBAND'S HEAD WENT THROUGH THE BACK WINDSHIELD OF THE TRUCK CAUSING NECK AND BACK INJURIES.
NHTSA ODI #756645
Mileage unknown · Jan 9, 2002
Fuel System, Gasoline
DRIVER NOTICED A PUDDLE OF GAS ON GROUND RIGHT BELOW GAS CAP. GAS WAS LEAKING FROM REAR TANK. CAUSE UNKNOWN. PLEASE PROVIDE ANY FURTHER INFORMATION.*AK
NHTSA ODI #8001874
Official recalls
7Feb 4, 2008
FORD IS RECALLING 225,000 MY 1992-2003 ECONOLINE, MY 1993-1995 TAURUS SHO, MY 1992-1998 CROWN VICTORIA, MY 1993 BRONCO, F-SERIES, MY 1995-1997 F-SERIES SUPER DUTY STRIPPED CHASSIS, MY 1992-1998 MERCURY GRAND MARQUIS, AND MY 1992-1995 LINCOLN TOWN CAR VEHICLES. THE AFFECTED VEHICLES WERE PREVIOUSLY REPAIRED USING A WIRING HARNESS THAT IS NOT COMPATIBLE WITH THE VEHICLE CIRCUIT POLARITY.
Consequence & remedy
Consequence: AS A RESULT, THE FUSE IS LOCATED IN THE OUTPUT CIRCUIT RATHER THAN IN THE INTENDED INPUT POWER FEED CIRCUIT, AND MAY NOT OFFER THE INTENDED PROTECTION IN THE EVENT OF AN ELECTRICAL SHORT TO GROUND.
Remedy: DEALERS WILL INSTALL A NEW WIRING HARNESS, OR REPLACE THE MATING ELECTRICAL COMPONENT. THE RECALL BEGAN ON FEBRUARY 18, 2008. OWNERS MAY CONTACT FORD AT 1-800-392-3673.
Aug 3, 2007
ON CERTAIN PICKUP TRUCKS, PASSENGER VEHICLES, SPORT UTILITY VEHICLES, AND MOTOR HOMES CHASSIS, THE SPEED CONTROL DEACTIVATION SWITCH MAY, UNDER CERTAIN CONDITIONS, LEAK INTERNALLY AND THEN OVERHEAT, SMOKE, OR BURN.
Consequence & remedy
Consequence: THIS COULD RESULT IN AN UNDERHOOD FIRE.
Remedy: DEALERS WILL INSTALL A FUSED WIRING HARNESS. OWNERS OF THE PASSENGER CARS INCLUDED IN THIS CAMPAIGN WILL BE INSTRUCTED TO RETURN THEIR VEHICLES TO THEIR DEALERS TO HAVE THE SPEED CONTROL DEACTIVATION SWITCH DISCONNECTED AS AN INTERIM REPAIR. AS SOON AS REPAIR PARTS ARE AVAILABLE (EXPECTED OCTOBER 2007), OWNERS WILL BE INSTRUCTED TO RETURN TO THE DEALERS FOR INSTALLATION OF A FUSED WIRING HARNESS. THE RECALL BEGAN ON AUGUST 13, 2007, AND MAILING COMPLETED BY SEPTEMBER 19, 2007. OWNERS MAY CONTACT FORD AT 1-888-222-2751.
Dec 29, 2000
VEHICLE DESCRIPTION: LIGHT DUTY TRUCKS AND CAB CHASSIS EQUIPPED WITH GASOLINE ENGINES AND DUAL FUEL TANKS. THE CARBON STEEL FUEL PRESSURE REGULATOR IN THE FUEL SYSTEM CAN WEAR OUT DURING THE LIFE OF THE VEHICLE. IF THE FUEL PRESSURE REGULATOR MALFUNCTIONS, IT CAN CAUSE HIGH FUEL SYSTEM PRESSURE, WHICH DAMAGES THE FUEL PUMP CHECK VALVE. THIS ALLOWS FUEL TO BE TRANSFERRED FROM ONE TANK TO THE OTHER, POSSIBLY OVERFILLING THE NON-OPERATING TANK, RESULTING IN FUEL OVERFLOW PAST THE FILLER CAP.
Consequence & remedy
Consequence: FUEL LEAKAGE IN THE PRESENCE OF AN IGNITION SOURCE COULD RESULT IN A VEHICLE FIRE.
Remedy: DEALERS WILL HAVE A STAINLESS STEEL FUEL PRESSURE REGULATOR INSTALLED. OWNER NOTIFICATION BEGAN JULY 9, 2001. OWNERS WHO TAKE THEIR VEHICLES TO AN AUTHORIZED DEALER ON AN AGREED UPON SERVICE DATE AND DO NOT RECEIVE THE FREE REMEDY WITHIN A REASONABLE TIME SHOULD CONTACT FORD AT 1-866-436-7332. (SEE PREVIOUS NHTSA RECALL 93V-125/FORD RECALL 93S68).
Sep 7, 1994
THE PARKING BRAKE CONTROL SELF-ADJUST PAWL DOES NOT LINE UP PROPERLY WITH THE SELF-ADJUST RACHET CAUSING THE PAWL TO SLIP OVER ONE OR MORE TEETH IN THE RACHET.
Consequence & remedy
Consequence: WHEN THE ABOVE OCCURS, IT CAN RESULT IN PARKING BRAKE SYSTEM INEFFECTIVENESS. THE PARKING BRAKE WILL NOT HOLD THE VEHICLE, CAUSING THE VEHICLE TO ROLL FREELY, IF THE TRANSMISSION IS NOT LEFT IN GEAR.
Remedy: A WEDGE WILL BE INSTALLED WHICH WILL SERVE TO LOCK THE PARKING BRAKE SELF-ADJUST MECHANISM PAWL INTO ENGAGEMENT WITH THE RACHET. ALSO, OWNERS WILL BE ADVISED TO RELEASE AND REAPPLY THE PARKING BRAKE WHENEVER TOOTH SKIP OCCURS AND WILL BE REMINDED TO ALWAYS TURN OFF THE ENGINE AND LEAVE THE VEHICLE IN GEAR WHEN THE VEHICLE IS PARKED.
Jan 2, 1994
THE U-CLIP STYLE NUTS THAT RETAIN THE FRONT BUMPERS TO THE FRONT BUMPER INNER ARMS CAN FRACTURE.
Consequence & remedy
Consequence: IF ONE OF THE U-CLIP NUTS FRACTURES, THE BUMPER WILL LOOSEN AND RATTLE CAUSING FRACTURE OF THE REMAINING U-CLIP NUTS, RESULTING IN SEPARATION OF THE BUMPER FROM THE VEHICLE. IF THE BUMPER WERE TO DETACH FROM THE VEHICLE WHILE IT IS BEING DRIVEN, A VEHICLE COLLISION COULD RESULT.
Remedy: INSPECTION AND REPLACEMENT OF THE FOUR U-CLIP NUTS AND THE ASSOCIATED BOLTS.
Aug 2, 1993
A MALFUNCTIONING CHECK VALVE WITHIN THE FUEL PUMP ASSEMBLY CAUSES A PORTION OF THE UNUSED FUEL FROM ONE TANK TO BE RETURNED TO THE SECOND TANK. WHEN THIS OCCURS, THE CAPACITY OF THE SECOND TANK CAN BE EXCEEDED, CAUSING FUEL SPILLAGE.
Consequence & remedy
Consequence: SPILLED FUEL CAN RESULT IN A FIRE WHEN EXPOSED TO ASOURCE OF IGNITION.
Remedy: REPLACEMENT OF THE FUEL PRESSURE REGULATOR AND INSTALLATION OF REDUNDANT CHECK VALVES.
May 17, 1993
THE TRANSFER CASES HAVE BEEN BUILT WITH THE WRONG ELECTRIC SHIFT MOTOR. THE TRANSFER CASES CAN SLIP OUT OF THE 4 X 4 HIGH GEAR POSITION DURING COASTING IN FORWARD GEARS OR WITH POWER APPLIED IN REVERSE GEAR.
Consequence & remedy
Consequence: IF THIS OCCURS, THE VEHICLE CAN ROLL FREELY AS IF INNEUTRAL POSITION REGARDLESS OF THE TRANSMISSION GEAR SELECTOR POSITION. THIS CANRESULT IN LOSS OF VEHICLE CONTROL AND AN ACCIDENT.
Remedy: REPLACE DEFECTIVE TRANSFER CASES WITH THE CORRECT VERSION.
Model-level recall history does not show whether a particular VIN is affected or has received a repair. Check a VIN with NHTSA ↗
NHTSA investigations
2EA99032 · Dual Fuel Tank Crossflow/leakage
Opened Nov 4, 1999 · Closed Dec 6, 2001
Status: closed (inferred from source dates) · Vehicle Speed Control:linkages
ON JULY 14, 1993 FORD FILED A DEFECT INFORMATION REPORT CONCERNING FUEL TANK CROSS FLOW LEAKAGE ON F-SERIES LIGHT TRUCKS AND CAB CHASSIS BUILT FROM JULY 22, 1989 THROUGH DECEMBER 17, 1992.THE REMEDY WAS TO REPLACE THE FUEL PRESSURE REGULATOR AND INSTALL A CHECK VALVE BETWEEN EACH FUEL SUPPLY LINE AND FUEL TANK (2) TO REPAIR THE SUPPLY SIDE FUEL CROSS FLOW PROBLEM (RECALL 93V-125).ODI OPENED RQ98-008 ON MAY 29, 1998 BECAUSE OF THE LARGE NUMBER OF ALLEGED REMEDY FAILURES AND REPORTS OF FUEL CROSS FLOW ON VEHICLES OUTSIDE OF THE RECALL POPULATION.BASED ONTHE INFORMATION RECEIVED FROM FORD ON AUGUST 11, SEPTEMBER 30, AND DECEMBER 15, 1998, AND THE INCREASING TREND OF REMEDY FAILURES AND OUT OF SCOPE CROSSFLOW REPORTS, ODI OPENED EA99-032 ON NOVEMBER 4, 1999.THE ATTACHED ENGINEERING ANALYSIS CLOSING REPORT FULLY DESCRIBES THE RESULTS OF THIS INVESTIGATION AND REASON FOR CLOSING.THE SUBJECT VEHICLES CAN EXPERIENCE FUEL TRANSFER FROM ONE TANK TO THE OTHER DUE TO MALFUNCTIONS IN THE FUEL SYSTEM.WHEN FUEL IS PUMPED OR RETURNED TO THE NON-OPERATING TANK (CROSS FLOW), THE CAPACITY OF THE NON-OPERATING TANK CAN BE EXCEEDED, CAUSING FUEL TO OVERFLOW PAST THE FILLER CAP, CREATING A FIRE POTENTIAL.
Additional source detail variants (2)
Vehicle Speed Control:linkages
ON JULY 14, 1993 FORD FILED A DEFECT INFORMATION REPORT CONCERNING FUEL TANK CROSS FLOW LEAKAGE ON F-SERIES LIGHT TRUCKS AND CAB CHASSIS BUILT FROM JULY 22, 1989 THROUGH DECEMBER 17, 1992.THE REMEDY WAS TO REPLACE THE FUEL PRESSURE REGULATOR AND INSTALL A CHECK VALVE BETWEEN EACH FUEL SUPPLY LINE AND FUEL TANK (2) TO REPAIR THE SUPPLY SIDE FUEL CROSS FLOW PROBLEM (RECALL 93V-125).ODI OPENED RQ98-008 ON MAY 29, 1998 BECAUSE OF THE LARGE NUMBER OF ALLEGED REMEDY FAILURES AND REPORTS OF FUEL CROSS FLOW ON VEHICLES OUTSIDE OF THE RECALL POPULATION.BASED ONTHE INFORMATION RECEIVED FROM FORD ON AUGUST 11, SEPTEMBER 30, AND DECEMBER 15, 1998, AND THE INCREASING TREND OF REMEDY FAILURES AND OUT OF SCOPE CROSSFLOW REPORTS, ODI OPENED EA99-032 ON NOVEMBER 4, 1999.THE ATTACHED ENGINEERING ANALYSIS CLOSING REPORT FULLY DESCRIBES THE RESULTS OF THIS INVESTIGATION AND REASON FOR CLOSING.THE SUBJECT VEHICLES CAN EXPERIENCE FUEL TRANSFER FROM ONE TANK TO THE OTHER DUE TO MALFUNCTIONS IN THE FUEL SYSTEM.WHEN FUEL IS PUMPED OR RETURNED TO THE NON-OPERATING TANK (CROSS FLOW), THE CAPACITY OF THE NON-OPERATING TANK CAN BE EXCEEDED, CAUSING FUEL TO OVERFLOW PAST THE FILLER CAP, CREATING A FIRE POTENTIAL.
Vehicle Speed Control:linkages
ON JULY 14, 1993 FORD FILED A DEFECT INFORMATION REPORT CONCERNING FUEL TANK CROSS FLOW LEAKAGE ON F-SERIES LIGHT TRUCKS AND CAB CHASSIS BUILT FROM JULY 22, 1989 THROUGH DECEMBER 17, 1992.THE REMEDY WAS TO REPLACE THE FUEL PRESSURE REGULATOR AND INSTALL A CHECK VALVE BETWEEN EACH FUEL SUPPLY LINE AND FUEL TANK (2) TO REPAIR THE SUPPLY SIDE FUEL CROSS FLOW PROBLEM (RECALL 93V-125).ODI OPENED RQ98-008 ON MAY 29, 1998 BECAUSE OF THE LARGE NUMBER OF ALLEGED REMEDY FAILURES AND REPORTS OF FUEL CROSS FLOW ON VEHICLES OUTSIDE OF THE RECALL POPULATION.BASED ONTHE INFORMATION RECEIVED FROM FORD ON AUGUST 11, SEPTEMBER 30, AND DECEMBER 15, 1998, AND THE INCREASING TREND OF REMEDY FAILURES AND OUT OF SCOPE CROSSFLOW REPORTS, ODI OPENED EA99-032 ON NOVEMBER 4, 1999.THE ATTACHED ENGINEERING ANALYSIS CLOSING REPORT FULLY DESCRIBES THE RESULTS OF THIS INVESTIGATION AND REASON FOR CLOSING.THE SUBJECT VEHICLES CAN EXPERIENCE FUEL TRANSFER FROM ONE TANK TO THE OTHER DUE TO MALFUNCTIONS IN THE FUEL SYSTEM.WHEN FUEL IS PUMPED OR RETURNED TO THE NON-OPERATING TANK (CROSS FLOW), THE CAPACITY OF THE NON-OPERATING TANK CAN BE EXCEEDED, CAUSING FUEL TO OVERFLOW PAST THE FILLER CAP, CREATING A FIRE POTENTIAL.
RQ98008 · Ford F-SERIES Dual Fuel Tank Leakage
Opened May 29, 1998 · Closed Nov 4, 1999
Status: closed (inferred from source dates) · Fuel System, Gasoline:storage:tank Assembly
THESE VEHICLES CAN EXPERIENCE FUEL TRANSFER FROM ONE TANK TO THE OTHER DUE TO A MALFUNCTIONING FUEL PUMP.FROM THE INFORMATION GATHERED TO DATE, IT APPEARS THAT THERE CAN BE MULTIPLE CAUSES AND/OR A COMBINATION OF CAUSES FOR FUEL CROSS FLOW AND THAT THE RECALL REMEDY MAY BE INADEQUATE.FURTHER INVESTIGATION IS NEEDED.THIS INVESTIGATION IS UPGRADED TO EA99-032.CLICK ON DOCUMENT SEARCH BUTTON FOR ADDITIONAL INFORMATION.