← New search

1992 Ford F-150

Owner reports · Recalls · Investigations

Similar to other model years

Owner complaints for the 1992 Ford F-150 do not stand out strongly from the model-year median of 676.

About this comparison →

When problems were reported

Mileage at the reported incident

Limited mileage data: 49 of 470 reports include usable mileage. There isn’t enough coverage to show a useful chart.

NHTSA’s mileage field refers to the reported incident, not necessarily the filing date. This shows report counts, not the likelihood of a failure.

What to inspect

Issues worth paying extra attention to based on owner reports.

  • Fuel System, Gasoline. Review the 231 owner reports in this category and discuss these concerns during a pre-purchase inspection. Read reports →
  • Electrical System. Review the 48 owner reports in this category and discuss these concerns during a pre-purchase inspection. Read reports →
  • Engine And Engine Cooling. Review the 37 owner reports in this category and discuss these concerns during a pre-purchase inspection. Read reports →

NHTSA owner reports · September 18, 2026 snapshot.

20 crash reports38 fire reports11 injury reports

What owners actually said

470 reports
Mileage unknown · Feb 23, 2001
Fuel System, Gasoline

RECALL 93V125000/ FUEL TANK ASSEMBLY PERFORMED IN 1994, VEHICLE HAS SAME PROBLEM AGAIN. *AK

NHTSA ODI #881264

Mileage unknown · Feb 21, 2001
Fuel System, Gasoline

CONSUMER'S VEHICLE WAS NOT COVERED UNDER RECALL 93V12500 / TANK ASSEMBLY FAILURE DUE TO VIN ALTHOUGH IT HAS EXPERIENCED SAME PROBLEM.*AK

NHTSA ODI #880941

Mileage unknown · Feb 7, 2001
Fuel System, Gasoline

ONE TANK IS DRAINING INTO OTHER TANK, CAUSING IT TO BACK UP AND OVERFLOW. PLEASE PROVIDE FURTHER INFORMATION. *AK

NHTSA ODI #879993

Mileage unknown · Feb 5, 2001
Fuel System, Gasoline

WHEN PUMPING ONE TANK IT OVERFLOWS INTO OTHER TANK THAT IS FULL.*AK

NHTSA ODI #879733

Mileage unknown · Feb 2, 2001
Fuel System, Gasoline

FUEL GOES FROM FRONT TANK TO BACK TANK, AND IF IT IS FULL IT WILL START TO LEAK OUT. *AK

NHTSA ODI #879679

Mileage unknown · Feb 1, 2001
Fuel System, Gasoline

GAS IS POURING OUT OF ONE OF TANKS. WHENEVER PUTTING GAS IN ONE TANK, IT PUMPS INTO THE OTHER AND OVER FLOWS. CONSUMER FEELS THIS IS VERY DANGEROUS. *AK

NHTSA ODI #879605

Mileage unknown · Jan 23, 2001
Fuel System, Gasoline

WHENEVER BOTH TANKS ARE FULL AND VEHICLE IS RUNNING GAS WILL PUMP OUT OF ONE TANK INTO OTHER. WHEN THIS HAPPENS IT FORCES GAS OUT TO GROUND BECAUSE TANK IS ALREADY FULL.*AK

NHTSA ODI #878837

Mileage unknown · Jan 11, 2001
Fuel System, Gasoline

ONE FUEL TANK IS FORCING FUEL INTO THE OTHER TANK, CAUSING IT TO OVERFLOW AND LEAK, RESULTING IN POSSIBLE FIRE HAZARD. *AK

NHTSA ODI #878023

Mileage unknown · Jan 10, 2001
Fuel System, Gasoline

DUAL FUEL TAN; WHEN ONE TANK IS FULL GASOLINE WILL SHIFT OVER TO OTHER FUEL TANK, AND CAUSE FUEL SPILLAGE OUT OF FUEL NECK. SPILLAGE WILL OCCUR WHETHER SECOND TANK IS FULL OR EMPTY. THIS IS A RELATED INCIDENT TO RECALL 93V125000. RECALLS WAS THE 93 MODEL BUT THE CONSUMER VEHCLE IS 92. *AK

NHTSA ODI #877955

Mileage unknown · Jan 10, 2001
Fuel System, Gasoline

RECALL 93V125 00/FUEL TANK ASSEMBLY: A PORTION OF UNUSED FUEL FROM ONE TANK TO BE RETURNED TO SECOND TANK . WHEN THIS OCCURRRED, SECOND TANK EXCEEDED, CAUSING FUEL SPILLAGES. SPILL CAN RESULT IN A FIRE WHEN EXPOSED TO A SOURCE OF IGNITION; DEALER NOTIFIED, AND INFORMED CONSUMER VEHICLE WAS NOT COVERED UNDER RECALL DUE TO VIN…

Read full complaint

RECALL 93V125 00/FUEL TANK ASSEMBLY: A PORTION OF UNUSED FUEL FROM ONE TANK TO BE RETURNED TO SECOND TANK . WHEN THIS OCCURRRED, SECOND TANK EXCEEDED, CAUSING FUEL SPILLAGES. SPILL CAN RESULT IN A FIRE WHEN EXPOSED TO A SOURCE OF IGNITION; DEALER NOTIFIED, AND INFORMED CONSUMER VEHICLE WAS NOT COVERED UNDER RECALL DUE TO VIN. PLEASE FILL FREE TO PROVIDE ANY FURTHER DETAILS ON THIS MATTER. *AK

NHTSA ODI #877954

Official recalls

3

94V169001 · Parking Brake:conventional

Sep 7, 1994

THE PARKING BRAKE CONTROL SELF-ADJUST PAWL DOES NOT LINE UP PROPERLY WITH THE SELF-ADJUST RACHET CAUSING THE PAWL TO SLIP OVER ONE OR MORE TEETH IN THE RACHET.

Consequence & remedy

Consequence: WHEN THE ABOVE OCCURS, IT CAN RESULT IN PARKING BRAKE SYSTEM INEFFECTIVENESS. THE PARKING BRAKE WILL NOT HOLD THE VEHICLE, CAUSING THE VEHICLE TO ROLL FREELY, IF THE TRANSMISSION IS NOT LEFT IN GEAR.

Remedy: A WEDGE WILL BE INSTALLED WHICH WILL SERVE TO LOCK THE PARKING BRAKE SELF-ADJUST MECHANISM PAWL INTO ENGAGEMENT WITH THE RACHET. ALSO, OWNERS WILL BE ADVISED TO RELEASE AND REAPPLY THE PARKING BRAKE WHENEVER TOOTH SKIP OCCURS AND WILL BE REMINDED TO ALWAYS TURN OFF THE ENGINE AND LEAVE THE VEHICLE IN GEAR WHEN THE VEHICLE IS PARKED.

93V125000 · Fuel System, Gasoline:storage:tank Assembly

Aug 2, 1993

A MALFUNCTIONING CHECK VALVE WITHIN THE FUEL PUMP ASSEMBLY CAUSES A PORTION OF THE UNUSED FUEL FROM ONE TANK TO BE RETURNED TO THE SECOND TANK. WHEN THIS OCCURS, THE CAPACITY OF THE SECOND TANK CAN BE EXCEEDED, CAUSING FUEL SPILLAGE.

Consequence & remedy

Consequence: SPILLED FUEL CAN RESULT IN A FIRE WHEN EXPOSED TO ASOURCE OF IGNITION.

Remedy: REPLACEMENT OF THE FUEL PRESSURE REGULATOR AND INSTALLATION OF REDUNDANT CHECK VALVES.

92V006000 · Structure:body:door

Jan 14, 1992

WATER CAN ENTER THE DOOR LATCH RELEASE CABLE. IF THE VEHICLE IS OPERATED IN BELOW FREEZING TEMPERATURES, THE WATER IN THE DOOR LATCH RELEASE CABLE CAN FREEZE AND CAUSE THE LATCH MECHANISM TO MALFUNCTION.

Consequence & remedy

Consequence: THE MALFUNCTION OF THE DOOR LATCH RELEASE CAN RESULT INTHREE DIFFERENT PROBLEMS: 1) THE DOOR WILL NOT BE ABLE TO BE RELATCHED, 2) THEINSIDE DOOR HANDLE CAN BECOME INOPERATIVE, AND 3) THE DOOR COULD APPEAR TO BELATCHED WHEN IT IS NOT, ALLOWING THE DOOR TO OPEN UNEXPECTEDLY IF IT IS JARRED,AND INCREASING THE RISK OF INJURY TO THE ADJACENT SEAT OCCUPANT.

Remedy: REVISED DOOR RELEASE CABLES AND WATER SHIELDS WILL BE INSTALLED.

Model-level recall history does not show whether a particular VIN is affected or has received a repair. Check a VIN with NHTSA ↗

NHTSA investigations

8

EA99032 · Dual Fuel Tank Crossflow/leakage

Opened Nov 4, 1999 · Closed Dec 6, 2001

Status: closed (inferred from source dates) · Vehicle Speed Control:linkages

ON JULY 14, 1993 FORD FILED A DEFECT INFORMATION REPORT CONCERNING FUEL TANK CROSS FLOW LEAKAGE ON F-SERIES LIGHT TRUCKS AND CAB CHASSIS BUILT FROM JULY 22, 1989 THROUGH DECEMBER 17, 1992.THE REMEDY WAS TO REPLACE THE FUEL PRESSURE REGULATOR AND INSTALL A CHECK VALVE BETWEEN EACH FUEL SUPPLY LINE AND FUEL TANK (2) TO REPAIR THE SUPPLY SIDE FUEL CROSS FLOW PROBLEM (RECALL 93V-125).ODI OPENED RQ98-008 ON MAY 29, 1998 BECAUSE OF THE LARGE NUMBER OF ALLEGED REMEDY FAILURES AND REPORTS OF FUEL CROSS FLOW ON VEHICLES OUTSIDE OF THE RECALL POPULATION.BASED ONTHE INFORMATION RECEIVED FROM FORD ON AUGUST 11, SEPTEMBER 30, AND DECEMBER 15, 1998, AND THE INCREASING TREND OF REMEDY FAILURES AND OUT OF SCOPE CROSSFLOW REPORTS, ODI OPENED EA99-032 ON NOVEMBER 4, 1999.THE ATTACHED ENGINEERING ANALYSIS CLOSING REPORT FULLY DESCRIBES THE RESULTS OF THIS INVESTIGATION AND REASON FOR CLOSING.THE SUBJECT VEHICLES CAN EXPERIENCE FUEL TRANSFER FROM ONE TANK TO THE OTHER DUE TO MALFUNCTIONS IN THE FUEL SYSTEM.WHEN FUEL IS PUMPED OR RETURNED TO THE NON-OPERATING TANK (CROSS FLOW), THE CAPACITY OF THE NON-OPERATING TANK CAN BE EXCEEDED, CAUSING FUEL TO OVERFLOW PAST THE FILLER CAP, CREATING A FIRE POTENTIAL.

Additional source detail variants (2)

Vehicle Speed Control:linkages

ON JULY 14, 1993 FORD FILED A DEFECT INFORMATION REPORT CONCERNING FUEL TANK CROSS FLOW LEAKAGE ON F-SERIES LIGHT TRUCKS AND CAB CHASSIS BUILT FROM JULY 22, 1989 THROUGH DECEMBER 17, 1992.THE REMEDY WAS TO REPLACE THE FUEL PRESSURE REGULATOR AND INSTALL A CHECK VALVE BETWEEN EACH FUEL SUPPLY LINE AND FUEL TANK (2) TO REPAIR THE SUPPLY SIDE FUEL CROSS FLOW PROBLEM (RECALL 93V-125).ODI OPENED RQ98-008 ON MAY 29, 1998 BECAUSE OF THE LARGE NUMBER OF ALLEGED REMEDY FAILURES AND REPORTS OF FUEL CROSS FLOW ON VEHICLES OUTSIDE OF THE RECALL POPULATION.BASED ONTHE INFORMATION RECEIVED FROM FORD ON AUGUST 11, SEPTEMBER 30, AND DECEMBER 15, 1998, AND THE INCREASING TREND OF REMEDY FAILURES AND OUT OF SCOPE CROSSFLOW REPORTS, ODI OPENED EA99-032 ON NOVEMBER 4, 1999.THE ATTACHED ENGINEERING ANALYSIS CLOSING REPORT FULLY DESCRIBES THE RESULTS OF THIS INVESTIGATION AND REASON FOR CLOSING.THE SUBJECT VEHICLES CAN EXPERIENCE FUEL TRANSFER FROM ONE TANK TO THE OTHER DUE TO MALFUNCTIONS IN THE FUEL SYSTEM.WHEN FUEL IS PUMPED OR RETURNED TO THE NON-OPERATING TANK (CROSS FLOW), THE CAPACITY OF THE NON-OPERATING TANK CAN BE EXCEEDED, CAUSING FUEL TO OVERFLOW PAST THE FILLER CAP, CREATING A FIRE POTENTIAL.

Vehicle Speed Control:linkages

ON JULY 14, 1993 FORD FILED A DEFECT INFORMATION REPORT CONCERNING FUEL TANK CROSS FLOW LEAKAGE ON F-SERIES LIGHT TRUCKS AND CAB CHASSIS BUILT FROM JULY 22, 1989 THROUGH DECEMBER 17, 1992.THE REMEDY WAS TO REPLACE THE FUEL PRESSURE REGULATOR AND INSTALL A CHECK VALVE BETWEEN EACH FUEL SUPPLY LINE AND FUEL TANK (2) TO REPAIR THE SUPPLY SIDE FUEL CROSS FLOW PROBLEM (RECALL 93V-125).ODI OPENED RQ98-008 ON MAY 29, 1998 BECAUSE OF THE LARGE NUMBER OF ALLEGED REMEDY FAILURES AND REPORTS OF FUEL CROSS FLOW ON VEHICLES OUTSIDE OF THE RECALL POPULATION.BASED ONTHE INFORMATION RECEIVED FROM FORD ON AUGUST 11, SEPTEMBER 30, AND DECEMBER 15, 1998, AND THE INCREASING TREND OF REMEDY FAILURES AND OUT OF SCOPE CROSSFLOW REPORTS, ODI OPENED EA99-032 ON NOVEMBER 4, 1999.THE ATTACHED ENGINEERING ANALYSIS CLOSING REPORT FULLY DESCRIBES THE RESULTS OF THIS INVESTIGATION AND REASON FOR CLOSING.THE SUBJECT VEHICLES CAN EXPERIENCE FUEL TRANSFER FROM ONE TANK TO THE OTHER DUE TO MALFUNCTIONS IN THE FUEL SYSTEM.WHEN FUEL IS PUMPED OR RETURNED TO THE NON-OPERATING TANK (CROSS FLOW), THE CAPACITY OF THE NON-OPERATING TANK CAN BE EXCEEDED, CAUSING FUEL TO OVERFLOW PAST THE FILLER CAP, CREATING A FIRE POTENTIAL.

RQ98008 · Ford F-SERIES Dual Fuel Tank Leakage

Opened May 29, 1998 · Closed Nov 4, 1999

Status: closed (inferred from source dates) · Fuel System, Gasoline:storage:tank Assembly

THESE VEHICLES CAN EXPERIENCE FUEL TRANSFER FROM ONE TANK TO THE OTHER DUE TO A MALFUNCTIONING FUEL PUMP.FROM THE INFORMATION GATHERED TO DATE, IT APPEARS THAT THERE CAN BE MULTIPLE CAUSES AND/OR A COMBINATION OF CAUSES FOR FUEL CROSS FLOW AND THAT THE RECALL REMEDY MAY BE INADEQUATE.FURTHER INVESTIGATION IS NEEDED.THIS INVESTIGATION IS UPGRADED TO EA99-032.CLICK ON DOCUMENT SEARCH BUTTON FOR ADDITIONAL INFORMATION.

EA93022 · Idle Air Spd Ctrl Vlv Malf

Opened Jul 30, 1993 · Closed Aug 31, 1994

Status: closed (inferred from source dates) · Engine And Engine Cooling

There is no summary currently available

EA93020 · Parking Brake Failure

Opened Jul 28, 1993 · Closed Sep 23, 1994

Status: closed (inferred from source dates) · Service Brakes, Hydraulic

There is no summary currently available

Additional source detail variants (2)

Service Brakes, Hydraulic

There is no summary currently available

Service Brakes, Hydraulic

There is no summary currently available

PE93015 · Parking Brake Failure

Opened Mar 9, 1993 · Closed Jul 27, 1993

Status: closed (inferred from source dates) · Service Brakes, Hydraulic

There is no summary currently available

PE93010 · Idle Air Spd Ctrl Vlv Malf

Opened Mar 2, 1993 · Closed Jul 30, 1993

Status: closed (inferred from source dates) · Engine And Engine Cooling

There is no summary currently available

EA93001 · Fuel Expulsion

Opened Jan 7, 1993 · Closed Aug 20, 1993

Status: closed (inferred from source dates) · Vehicle Speed Control:linkages

There is no summary currently available

PE92077 · Fuel Expulsion

Opened Sep 9, 1992 · Closed Jan 7, 1993

Status: closed (inferred from source dates) · Vehicle Speed Control:linkages

There is no summary currently available