← New search

1991 Ford F-150

Owner reports · Recalls · Investigations

Similar to other model years

Owner complaints for the 1991 Ford F-150 do not stand out strongly from the model-year median of 676.

About this comparison →

When problems were reported

Mileage at the reported incident

Limited mileage data: 39 of 304 reports include usable mileage. There isn’t enough coverage to show a useful chart.

NHTSA’s mileage field refers to the reported incident, not necessarily the filing date. This shows report counts, not the likelihood of a failure.

What to inspect

Issues worth paying extra attention to based on owner reports.

  • Fuel System, Gasoline. Review the 149 owner reports in this category and discuss these concerns during a pre-purchase inspection. Read reports →
  • Electrical System. Review the 50 owner reports in this category and discuss these concerns during a pre-purchase inspection. Read reports →
  • Service Brakes, Hydraulic. Review the 23 owner reports in this category and discuss these concerns during a pre-purchase inspection. Read reports →

NHTSA owner reports · September 18, 2026 snapshot.

12 crash reports41 fire reports7 injury reports

What owners actually said

304 reports
Mileage unknown · May 24, 2000
Steering

WAS IN TRAFFIC WHEN BRAKES HAD TO BE APPLIED VERY QUICKLY. WHEN THIS HAPPENED, STEERING WHEEL BROKE OFF IN DRIVER'S HAND. COULD NOT FIND ANOTHER STEERING WHEEL IN THE JUNK YARDS. *AK *ML

NHTSA ODI #862454

Mileage unknown · May 18, 2000
Fuel System, Gasoline

VEHICLE WAS TAKEN IN TO BE REPAIRED UNDER THE RECALL #93V125000/ MANUFACTURER'S RECALL 93S68. HOWEVER, RECALL WAS FOR THE OVERFLOW OF THE DUAL FUEL TANKS. WHEN CONSUMER PICKED VEHICLE UP, PROBLEM WAS STILL PRESENT. THE DEALER HAS BEEN CONTACTED. *AK

NHTSA ODI #862088

Mileage unknown · May 16, 2000
Fuel System, Gasoline

REAR TANK APPEARS TO LEAK AT THE SEAM WHENEVER TANK IS HALF FULL OR MORE. DEALER WAS NOT CONTACTED AT THIS TIME. *AK

NHTSA ODI #861985

Mileage unknown · May 5, 2000
Fuel System, Gasoline

RECALL 93V125 000/ FUEL TANK ASSEMBLY. DEALER HAS REPAIRED VEHICLE UNDER THE RECALL. HOWEVER, THE REMEDY HAS FAILED. *AK

NHTSA ODI #861504

Mileage unknown · Apr 28, 2000
Fuel System, Gasoline

FUEL EXPELLED FROM FRONT TANK FUEL LINE;TANK WOULD NOT ACCEPT FUEL AFTER DEALER REPAIRS. *AK

NHTSA ODI #722071

Mileage unknown · Apr 19, 2000
Fuel System, Gasoline

EA 99 032: DUAL FUEL TANK CROSSFLOW LEAKAGE, AND 93V125000/FUEL TANK ASSEMBLY: A PORTION OF THE UNUSED FUEL FROM ONE TANK IS RETURNED TO SECOND TANK. WHEN THIS OCCURS, THE SECOND TANK EXCEEDS ITS LIMITS, CAUSING FUEL SPILLAGE. SPILL CAN RESULT IN A FIRE WHEN EXPOSED TO A SOURCE OF IGNITION. *AK

NHTSA ODI #860548

Mileage unknown · Mar 30, 2000
Fuel System, Gasoline

JUST FILLED VEHICLE'S FUEL TANKS. WAS DRIVING VEHICLE ON HIGHWAY & NOTICED FUEL WAS LEAKING OUT OF FUEL TANKS. PULLED VEHICLE OVER & CHECKED FUEL TANKS. NOTICED ONE TANK WAS EMPTYING INTO OTHER FUEL TANK , CAUSING AN OVERFLOW. *AK

NHTSA ODI #859494

Mileage unknown · Mar 22, 2000
Electrical System

IN AUGUST-SEPTEMBER 1997 I RESPONDED TO NHTSA RECALL 96V071000. THE DEALER IN PUYALLUP, WA REPLACED THE IGNITION SWITCH. HOWEVER, EVERY SINCE THEN WHEN THE TEMPERATURE DROPS DOWN BELOW 40 DEGREES THE IGNITION SWITCH SEEMS TO FREEZE UP. THIS ONLY HAPPENS IN THE FALL OR WINTER. I AM UNABLE TO TURN THE IGNITION SWITCH TO START …

Read full complaint

IN AUGUST-SEPTEMBER 1997 I RESPONDED TO NHTSA RECALL 96V071000. THE DEALER IN PUYALLUP, WA REPLACED THE IGNITION SWITCH. HOWEVER, EVERY SINCE THEN WHEN THE TEMPERATURE DROPS DOWN BELOW 40 DEGREES THE IGNITION SWITCH SEEMS TO FREEZE UP. THIS ONLY HAPPENS IN THE FALL OR WINTER. I AM UNABLE TO TURN THE IGNITION SWITCH TO START THE TRUCK. THE SWITCH BECOMES VERY STIFF UNLESS I FIRST WARM THE STEERING COLUMN WITH A SPACE HEATER OR BLOW DRYER. I AM AFRAID THAT ONE OF THESE DAYS I WILL BREAK THE SWITCH WHILE ATTEMPTING TO START THE TRUCK. *AK

NHTSA ODI #720454

Mileage unknown · Mar 13, 2000
Electrical SystemVehicle Speed Control

WHEN USING THE SPEED CONTROL, AND HAVING TO ACTIVATE THE LEFT TURN SIGNAL TO PASS, SPEED CONTROL CUTS OUT, CAUSING THE TRUCK TO SEVERELY DECELERATE. *AK

NHTSA ODI #858386

Mileage unknown · Mar 6, 2000
Fuel System, Gasoline

IF FIRST FUEL TANK IS NOT EMPTY, AND SWITCHING FROM ONE TANK TO THE OTHER, IT WILL DRAW FUEL FROM THE SECOND TANK AND OVERFLOW THE 1ST TANK, CAUSING FUEL SPILLAGE. CONTACTED DEALER. CONSUMER WAS ADVISED THAT THIS VEHICLE WAS NOT COVERED UNDER THE RECALL, AND ADVISED CONSUMER TO CALL FORD CUSTOMER SERVICE. *AK

NHTSA ODI #858030

Official recalls

3

96V071000 · Electrical System:ignition

Apr 25, 1996

THE IGNITION SWITCH COULD EXPERIENCE AN INTERNAL SHORT CIRCUIT.

Consequence & remedy

Consequence: THIS CONDITION COULD CAUSE OVERHEATING, SMOKE, AND POSSIBLY FIRE IN THE STEERING COLUMN AREA OF THE VEHICLE.

Remedy: DEALERS WILL REPLACE THE IGNITION SWITCH.

93V125000 · Fuel System, Gasoline:storage:tank Assembly

Aug 2, 1993

A MALFUNCTIONING CHECK VALVE WITHIN THE FUEL PUMP ASSEMBLY CAUSES A PORTION OF THE UNUSED FUEL FROM ONE TANK TO BE RETURNED TO THE SECOND TANK. WHEN THIS OCCURS, THE CAPACITY OF THE SECOND TANK CAN BE EXCEEDED, CAUSING FUEL SPILLAGE.

Consequence & remedy

Consequence: SPILLED FUEL CAN RESULT IN A FIRE WHEN EXPOSED TO ASOURCE OF IGNITION.

Remedy: REPLACEMENT OF THE FUEL PRESSURE REGULATOR AND INSTALLATION OF REDUNDANT CHECK VALVES.

93V066000 · Steering: Steering Wheel/handle Bar

Apr 27, 1993

KEYS ATTACHED TO THE KEY RING OF AN IGNITION KEY WHILE IT IS IN THE VEHICLE IGNITION CAN BECOME LODGED IN THE STEERING LOCK RECEIVER AS THE STEERING WHEEL IS BEING TURNED.

Consequence & remedy

Consequence: THE LODGED KEYS CAN CAUSE LOSS OF STEERING CONTROL, WHICHCAN RESULT IN AN ACCIDENT WHEN THE VEHICLE IS BEING USED ON THE HIGHWAY.

Remedy: A SHIELD WILL BE POSITIONED BETWEEN THE STEERING WHEEL AND THE IGNITION SWITCH AND HELD IN PLACE BY THE STEERING LOCK BAND.

Model-level recall history does not show whether a particular VIN is affected or has received a repair. Check a VIN with NHTSA ↗

NHTSA investigations

12

EA99032 · Dual Fuel Tank Crossflow/leakage

Opened Nov 4, 1999 · Closed Dec 6, 2001

Status: closed (inferred from source dates) · Vehicle Speed Control:linkages

ON JULY 14, 1993 FORD FILED A DEFECT INFORMATION REPORT CONCERNING FUEL TANK CROSS FLOW LEAKAGE ON F-SERIES LIGHT TRUCKS AND CAB CHASSIS BUILT FROM JULY 22, 1989 THROUGH DECEMBER 17, 1992.THE REMEDY WAS TO REPLACE THE FUEL PRESSURE REGULATOR AND INSTALL A CHECK VALVE BETWEEN EACH FUEL SUPPLY LINE AND FUEL TANK (2) TO REPAIR THE SUPPLY SIDE FUEL CROSS FLOW PROBLEM (RECALL 93V-125).ODI OPENED RQ98-008 ON MAY 29, 1998 BECAUSE OF THE LARGE NUMBER OF ALLEGED REMEDY FAILURES AND REPORTS OF FUEL CROSS FLOW ON VEHICLES OUTSIDE OF THE RECALL POPULATION.BASED ONTHE INFORMATION RECEIVED FROM FORD ON AUGUST 11, SEPTEMBER 30, AND DECEMBER 15, 1998, AND THE INCREASING TREND OF REMEDY FAILURES AND OUT OF SCOPE CROSSFLOW REPORTS, ODI OPENED EA99-032 ON NOVEMBER 4, 1999.THE ATTACHED ENGINEERING ANALYSIS CLOSING REPORT FULLY DESCRIBES THE RESULTS OF THIS INVESTIGATION AND REASON FOR CLOSING.THE SUBJECT VEHICLES CAN EXPERIENCE FUEL TRANSFER FROM ONE TANK TO THE OTHER DUE TO MALFUNCTIONS IN THE FUEL SYSTEM.WHEN FUEL IS PUMPED OR RETURNED TO THE NON-OPERATING TANK (CROSS FLOW), THE CAPACITY OF THE NON-OPERATING TANK CAN BE EXCEEDED, CAUSING FUEL TO OVERFLOW PAST THE FILLER CAP, CREATING A FIRE POTENTIAL.

Additional source detail variants (2)

Vehicle Speed Control:linkages

ON JULY 14, 1993 FORD FILED A DEFECT INFORMATION REPORT CONCERNING FUEL TANK CROSS FLOW LEAKAGE ON F-SERIES LIGHT TRUCKS AND CAB CHASSIS BUILT FROM JULY 22, 1989 THROUGH DECEMBER 17, 1992.THE REMEDY WAS TO REPLACE THE FUEL PRESSURE REGULATOR AND INSTALL A CHECK VALVE BETWEEN EACH FUEL SUPPLY LINE AND FUEL TANK (2) TO REPAIR THE SUPPLY SIDE FUEL CROSS FLOW PROBLEM (RECALL 93V-125).ODI OPENED RQ98-008 ON MAY 29, 1998 BECAUSE OF THE LARGE NUMBER OF ALLEGED REMEDY FAILURES AND REPORTS OF FUEL CROSS FLOW ON VEHICLES OUTSIDE OF THE RECALL POPULATION.BASED ONTHE INFORMATION RECEIVED FROM FORD ON AUGUST 11, SEPTEMBER 30, AND DECEMBER 15, 1998, AND THE INCREASING TREND OF REMEDY FAILURES AND OUT OF SCOPE CROSSFLOW REPORTS, ODI OPENED EA99-032 ON NOVEMBER 4, 1999.THE ATTACHED ENGINEERING ANALYSIS CLOSING REPORT FULLY DESCRIBES THE RESULTS OF THIS INVESTIGATION AND REASON FOR CLOSING.THE SUBJECT VEHICLES CAN EXPERIENCE FUEL TRANSFER FROM ONE TANK TO THE OTHER DUE TO MALFUNCTIONS IN THE FUEL SYSTEM.WHEN FUEL IS PUMPED OR RETURNED TO THE NON-OPERATING TANK (CROSS FLOW), THE CAPACITY OF THE NON-OPERATING TANK CAN BE EXCEEDED, CAUSING FUEL TO OVERFLOW PAST THE FILLER CAP, CREATING A FIRE POTENTIAL.

Vehicle Speed Control:linkages

ON JULY 14, 1993 FORD FILED A DEFECT INFORMATION REPORT CONCERNING FUEL TANK CROSS FLOW LEAKAGE ON F-SERIES LIGHT TRUCKS AND CAB CHASSIS BUILT FROM JULY 22, 1989 THROUGH DECEMBER 17, 1992.THE REMEDY WAS TO REPLACE THE FUEL PRESSURE REGULATOR AND INSTALL A CHECK VALVE BETWEEN EACH FUEL SUPPLY LINE AND FUEL TANK (2) TO REPAIR THE SUPPLY SIDE FUEL CROSS FLOW PROBLEM (RECALL 93V-125).ODI OPENED RQ98-008 ON MAY 29, 1998 BECAUSE OF THE LARGE NUMBER OF ALLEGED REMEDY FAILURES AND REPORTS OF FUEL CROSS FLOW ON VEHICLES OUTSIDE OF THE RECALL POPULATION.BASED ONTHE INFORMATION RECEIVED FROM FORD ON AUGUST 11, SEPTEMBER 30, AND DECEMBER 15, 1998, AND THE INCREASING TREND OF REMEDY FAILURES AND OUT OF SCOPE CROSSFLOW REPORTS, ODI OPENED EA99-032 ON NOVEMBER 4, 1999.THE ATTACHED ENGINEERING ANALYSIS CLOSING REPORT FULLY DESCRIBES THE RESULTS OF THIS INVESTIGATION AND REASON FOR CLOSING.THE SUBJECT VEHICLES CAN EXPERIENCE FUEL TRANSFER FROM ONE TANK TO THE OTHER DUE TO MALFUNCTIONS IN THE FUEL SYSTEM.WHEN FUEL IS PUMPED OR RETURNED TO THE NON-OPERATING TANK (CROSS FLOW), THE CAPACITY OF THE NON-OPERATING TANK CAN BE EXCEEDED, CAUSING FUEL TO OVERFLOW PAST THE FILLER CAP, CREATING A FIRE POTENTIAL.

RQ98008 · Ford F-SERIES Dual Fuel Tank Leakage

Opened May 29, 1998 · Closed Nov 4, 1999

Status: closed (inferred from source dates) · Fuel System, Gasoline:storage:tank Assembly

THESE VEHICLES CAN EXPERIENCE FUEL TRANSFER FROM ONE TANK TO THE OTHER DUE TO A MALFUNCTIONING FUEL PUMP.FROM THE INFORMATION GATHERED TO DATE, IT APPEARS THAT THERE CAN BE MULTIPLE CAUSES AND/OR A COMBINATION OF CAUSES FOR FUEL CROSS FLOW AND THAT THE RECALL REMEDY MAY BE INADEQUATE.FURTHER INVESTIGATION IS NEEDED.THIS INVESTIGATION IS UPGRADED TO EA99-032.CLICK ON DOCUMENT SEARCH BUTTON FOR ADDITIONAL INFORMATION.

EA93022 · Idle Air Spd Ctrl Vlv Malf

Opened Jul 30, 1993 · Closed Aug 31, 1994

Status: closed (inferred from source dates) · Engine And Engine Cooling

There is no summary currently available

PE93010 · Idle Air Spd Ctrl Vlv Malf

Opened Mar 2, 1993 · Closed Jul 30, 1993

Status: closed (inferred from source dates) · Engine And Engine Cooling

There is no summary currently available

EA93001 · Fuel Expulsion

Opened Jan 7, 1993 · Closed Aug 20, 1993

Status: closed (inferred from source dates) · Vehicle Speed Control:linkages

There is no summary currently available

PE92077 · Fuel Expulsion

Opened Sep 9, 1992 · Closed Jan 7, 1993

Status: closed (inferred from source dates) · Vehicle Speed Control:linkages

There is no summary currently available

EA92029 · Front Seat Back Failure

Opened Aug 27, 1992 · Closed Oct 29, 1993

Status: closed (inferred from source dates) · Seats

There is no summary currently available

PE92042 · Fnt Reclning Seat Bck Fail

Opened Apr 17, 1992 · Closed Aug 27, 1992

Status: closed (inferred from source dates) · Seats:front Assembly:recliner

There is no summary currently available

EA91044 · Loss Of Brake Effectivenes

Opened Oct 30, 1991 · Closed Oct 30, 1992

Status: closed (inferred from source dates) · Service Brakes, Hydraulic

===

EA91031 · Fuel Expulsion

Opened Jun 26, 1991 · Closed Nov 1, 1991

Status: closed (inferred from source dates) · Vehicle Speed Control:linkages

There is no summary currently available

PE91077 · Loss Of Brake Effectivenes

Opened May 23, 1991 · Closed Oct 31, 1991

Status: closed (inferred from source dates) · Service Brakes, Hydraulic

There is no summary currently available

PE91064 · Transmission Fluid Fires

Opened Apr 9, 1991 · Closed Jul 5, 1991

Status: closed (inferred from source dates) · Power Train

There is no summary currently available