← New search

2014 Chevrolet Silverado 2500

Owner reports · Recalls · Investigations

Similar to other model years

Owner complaints for the 2014 Chevrolet Silverado 2500 do not stand out strongly from the model-year median of 81.

About this comparison →

How this year compares

Owner complaints by model year

Other model years Selected year
Compare all Silverado 2500 years →

Counts vary with age, sales and reporting. They are not failure rates.

What owners reported most

All reported categories

Tap a category to read its complaints. One report may name several components.

When problems were reported

Mileage at the reported incident

24 reports with mileage · 16 unknown

NHTSA’s mileage field refers to the reported incident, not necessarily the filing date. This shows report counts, not the likelihood of a failure.

What to inspect

Issues worth paying extra attention to based on owner reports.

  • Fuel/propulsion System. Review the 8 owner reports in this category and discuss these concerns during a pre-purchase inspection. Read reports →
  • Engine. Review the 7 owner reports in this category and discuss these concerns during a pre-purchase inspection. Read reports →
  • Air Bags. Review the 6 owner reports in this category and discuss these concerns during a pre-purchase inspection. Read reports →

NHTSA owner reports · September 18, 2026 snapshot.

2 crash reports2 fire reports2 injury reports

Electrical System complaints

6 reports
Clear category filter
170,318 miles · Sep 18, 2023
Electrical System

TCM failed. Vehicle is at the dealership awaiting new part for over three months now. Continue to get extended ETA on the part, latest communication was maybe November before it ships. Last vehicle dealership had took a year for the replacement TCM Vehicle immediately went into ‘limp mode’ on highway, was very unsafe because co…

Read full complaint

TCM failed. Vehicle is at the dealership awaiting new part for over three months now. Continue to get extended ETA on the part, latest communication was maybe November before it ships. Last vehicle dealership had took a year for the replacement TCM Vehicle immediately went into ‘limp mode’ on highway, was very unsafe because could only go 20-25mph. Confirmed by dealer upon them working on pickup it was the TCM. They, as well as we researched, and found stated that this is widespread problem in 2011-2016 year Duramaxes. We were left vehicleless. We tow trailers for our business and fifth wheel camper for personal use. Very detrimental to our livelihood.

NHTSA ODI #11545297

Mileage unknown · Aug 23, 2023
Electrical System

Transmission Control Module Failed on the highway while towing and left me and family in a dangerous situation.

NHTSA ODI #11540440

99,985 miles · Nov 27, 2019
Electrical SystemEngine

I HAVE SEVERAL DTC CODES U029D U029E P0420 P220B ON THREE OCCASIONS. THESE CODE ARE TRIGGERING A LIMITED SPEED AND POSSIBLE POWER REDUCTION. THE DEALER SHIP STATES THAT GMC PROTOCOL IS TO REPLACE ONE SENSOR AT A TIME AND LET THE CUSTOMER GO SO THEY CAN BREAKDOWN AGAIN. THE PART THAT IS FAILING I AM TOLD IS THE DIESEL PARTICULA…

Read full complaint

I HAVE SEVERAL DTC CODES U029D U029E P0420 P220B ON THREE OCCASIONS. THESE CODE ARE TRIGGERING A LIMITED SPEED AND POSSIBLE POWER REDUCTION. THE DEALER SHIP STATES THAT GMC PROTOCOL IS TO REPLACE ONE SENSOR AT A TIME AND LET THE CUSTOMER GO SO THEY CAN BREAKDOWN AGAIN. THE PART THAT IS FAILING I AM TOLD IS THE DIESEL PARTICULATE FILTER, BUT GMC CAN NOT SUPPLY THE DEALERSHIPS WITH THE HIGH DEMAND. THIS SEEMS LIKE A FAULTY DESIGN THAT MAY WORK DURING THE WARRANTY PERIOD, BUT SHORTY FAILS AFTER. I DID REPORT EXHAUST SMELL IN THE TRUCK WHILE DRIVING . I WAS GIVEN A REPORT AND A LARGE REPAIR BILL ONLY TO BREAKDOWN IN 126 MILES.

NHTSA ODI #11282684

98,700 miles · Aug 3, 2018
Electrical SystemPower Train

THE TCM MALFUNCTIONED. AFTER BEING REPLACED THE VEHICLE STILL DIDN'T PERFORM AS IT DID BEFORE THE REPAIR. I HAVE RESEARCHED THIS ISSUE WITH ALL CHEVROLET TRUCKS FROM VARIOUS YEARS. THERE ARE MULTIPLE BLOGS FROM OWNERS OF THESE TRUCKS THAT SHOW THE EXTENT OF THE ISSUE. I CANNOT AFFORD TO PAY $ 1000.00 TO FIX A PROBLEM THAT GM KN…

Read full complaint

THE TCM MALFUNCTIONED. AFTER BEING REPLACED THE VEHICLE STILL DIDN'T PERFORM AS IT DID BEFORE THE REPAIR. I HAVE RESEARCHED THIS ISSUE WITH ALL CHEVROLET TRUCKS FROM VARIOUS YEARS. THERE ARE MULTIPLE BLOGS FROM OWNERS OF THESE TRUCKS THAT SHOW THE EXTENT OF THE ISSUE. I CANNOT AFFORD TO PAY $ 1000.00 TO FIX A PROBLEM THAT GM KNOWS THAT HAS EXISTED FOR YEARS. THIS IS A SERIOUS PROBLEM IF YOU ARE DRIVING AND THE TRUCK LOOSES POWER; ESPECIALLY WHEN YOU'RE GOING DOWN HILL TRAVELING AT A HIGH RATE OF SPEED AND YOUR TRANSMISSION DOESN'T FUNCTION PROPERLY. I HAVE HAD THE TRANSMISSION REPAIRED AND THE ISSUE PERSISTS; IT SEEMS AS THOUGH GM WANTS OWNERS TO PAY OUT OF POCKET. SOME MAY NOT AND THIS COULD LEAD TO UNSAFE TRUCKS BEING ON THE ROAD. THANK YOU.

NHTSA ODI #11115631

95,000 miles · May 7, 2017
Electrical SystemEngineVehicle Speed Control

WHILE DRIVING THE VEHICLE THE CHECK ENGINE LIGHT COMES ON, THE STABILITRAK LIGHT COMES ON AND THE VEHICLE SHUTS OFF. WITHIN SECONDS THE ENGINE RESTARTS. THE MOST COMMON OCCURRENCE IS WHEN TRAVELING ON BUMPY ROADS. WHEN THIS HAPPENS AT FREEWAY SPEEDS, THE SAME WILL HAPPEN, AND THE CRUISE CONTROL WILL DISCONNECT, AND CANNOT BE RES…

Read full complaint

WHILE DRIVING THE VEHICLE THE CHECK ENGINE LIGHT COMES ON, THE STABILITRAK LIGHT COMES ON AND THE VEHICLE SHUTS OFF. WITHIN SECONDS THE ENGINE RESTARTS. THE MOST COMMON OCCURRENCE IS WHEN TRAVELING ON BUMPY ROADS. WHEN THIS HAPPENS AT FREEWAY SPEEDS, THE SAME WILL HAPPEN, AND THE CRUISE CONTROL WILL DISCONNECT, AND CANNOT BE RESET UNTIL AROUND 30 MINUTES. AGAIN, THE ENGINE WILL DIE AND IMMEDIATELY RESTART. THIS IS HAPPENING MUCH MORE FREQUENTLY LATELY. THE VEHICLE HAS APPROXIMATELY 95,000 MILES ON THE ODOMETER.

NHTSA ODI #10983923

5,487 miles · Nov 25, 2014
Electrical SystemFire

ON OCTOBER 21, 2014 THE ENTIRE FUSE PANEL MELTED DOWN AND CAUGHT FIRE. THE TRUCK HAD STOPPED RUNNING. THE HOOD WAS ABLE TO BE RAISED AND THE FIRE WAS PUT OUT WITH FIRE EXTINGUISHER. THE TRUCK WAS TOWED TO THE DEALERSHIP WHERE IT WAS PURCHASED. GM HAS TAKEN NO RESPONSIBILITY IN THE REPAIR OF THIS VEHICLE. MY INSURANCE COMPAN…

Read full complaint

ON OCTOBER 21, 2014 THE ENTIRE FUSE PANEL MELTED DOWN AND CAUGHT FIRE. THE TRUCK HAD STOPPED RUNNING. THE HOOD WAS ABLE TO BE RAISED AND THE FIRE WAS PUT OUT WITH FIRE EXTINGUISHER. THE TRUCK WAS TOWED TO THE DEALERSHIP WHERE IT WAS PURCHASED. GM HAS TAKEN NO RESPONSIBILITY IN THE REPAIR OF THIS VEHICLE. MY INSURANCE COMPANY HAS AGREED TO PAY THE REPAIR BILL. THE CLAIM 048186-GB HAS BEEN SENT TO GM FOR REPAYMENT. I STRONGLY FEEL THAT THIS IS A MANUFACTURING DEFECT BY GM. THERE IS ALSO A SAFETY RECALL ISSUED FOR THIS VEHICLE #14515 WHICH I BELIEVE IS DIRECTLY RELATED TO THE INCIDENT THAT HAPPENED TO MY TRUCK. TO THIS DAY THE TRUCK IS STILL AT THE REPAIR SHOP WAITING ON PARTS. *TR

NHTSA ODI #10660762

Official recalls

2

21V054000 · Air Bags:frontal:passenger Side:inflator Module

Feb 5, 2021

General Motors, LLC (GM) is recalling certain 2014 Cadillac Escalade, Escalade ESV, Chevrolet Silverado 2500, Silverado 3500, Suburban, Tahoe, GMC Sierra 2500, Sierra 3500, Yukon, and Yukon XL vehicles originally sold, or ever registered, in the states of AL, CA, FL, GA, HI, LA, MS, SC, TX, PR, AS, GU, the MP, and VI or "Zone A." Additionally GM is recalling certain 2011-2014 Cadillac Escalade, Escalade ESV, Chevrolet Silverado 2500, Silverado 3500, Suburban, Tahoe, GMC Sierra 2500, Sierra 3500, Yukon, Yukon XL and 2011-2013 Cadillac Escalade EXT, Chevrolet Avalanche, Silverado 1500, and GMC Sierra 1500 vehicles originally sold, or ever registered, in the states of AZ, AR, DE, DC, IL, IN, KS, KY, MD, MO, NE, NV, NJ, NM, NC, OH, OK, PA, TN, VA, and WV or "Zone B." Additionally, GM is recalling certain 2010-2014 Cadillac Escalade, Escalade ESV, Chevrolet Silverado 2500, Silverado 3500, Suburban, Tahoe, GMC Sierra 2500, Sierra 3500, Yukon, and Yukon XL and 2010-2013 Cadillac Escalade EXT, Chevrolet Avalanche, Silverado 1500, and GMC Sierra 1500 vehicles originally sold, or ever registered, in the states of AK, CO, CT, ID, IA, ME, MA, MI, MN, MT, NH, NY, ND, OR, RI, SD, UT, VT, WA, WI, and WY or "Zone C." These vehicles are equipped with non-desiccated passenger frontal inflators containing phase-stabilized ammonium nitrate (PSAN) propellant. These inflators may explode due to propellant degradation occurring after long-term exposure to high absolute humidity, high temperatures, and high temperature cycling.

Consequence & remedy

Consequence: An inflator explosion may result in sharp metal fragments striking the driver or other occupants, resulting in serious injury or death.

Remedy: GM will notify owners, and dealers will replace the front passenger air bag inflator with an alternate one, free of charge. Interim letters notifying owners of the safety risk were mailed on February 25, 2021. Second notification letters will be mailed once the remedy is available. Owner notification letters were mailed to 40 VIN owners on May 11, 2021. A second owner notification letter was mailed to all other owners on January 24, 2022. Owners may contact Chevrolet customer service at 1-800-222-1020; Cadillac customer service at 1-800-458-8006; and GMC customer service at 1-800-462-8782. GM's number for this recall is N212328800.

18V267000 · Equipment

Apr 26, 2018

General Motors LLC (GM) is recalling certain 2009-2014 Chevrolet Silverado HD and GMC Sierra HD, 2009 GMC Topkick 5000, 6000, 7000 and 8000 Series and Isuzu F Series, and 2009-2018 Chevrolet Express, and GMC Savana vehicles, equipped with certain Plastic-Handle Fire Extinguishers or Push Button 'Pindicator' Fire Extinguishers. These extinguishers may become clogged, preventing the extinguisher from discharging as expected or requiring excessive force to activate the extinguisher. Additionally, in certain models, the nozzle may detach from the valve assembly with enough force that it could cause injury and also render the product inoperable. For a full list of the affected fire extinguisher models visit: https://static.nhtsa.gov/odi/rcl/2017/RMISC-17E062-5427.pdf

Consequence & remedy

Consequence: In the event of a fire, if the fire extinguisher does not function properly, it can increase the risk of injury.

Remedy: GM will notify owners, instructing them to contact Kidde to get a replacement fire extinguisher, free of charge. The recall began June 11, 2018. Owners may contact Chevrolet customer service at 1-800-222-1020, GMC customer service at 1-800-462-8782, and Isuzu customer service at 1-866-441-9638. GM's number for this recall is 18146.

Model-level recall history does not show whether a particular VIN is affected or has received a repair. Check a VIN with NHTSA ↗

NHTSA investigations

1

EA21002 · Desiccated Air Bag Inflator Rupture

Opened Sep 17, 2021 · No close date supplied

Status: open (inferred from source dates) · Air Bags:frontal:driver Side:inflator Module; Air Bags:frontal:passenger Side:inflator Module

From 2000 through 2017, Takata produced millions of air bag inflators using two types of phase-stabilized ammonium nitrate ("PSAN") propellant -- propellant 2004 and propellant 2004L. After prolonged exposure to high temperature cycles and humidity, inflators using propellant 2004 can degrade, causing the propellant to burn too quickly when ignited. The rapid burning can cause the inflator to rupture during deployment, potentially causing serious or even fatal injury to vehicle occupants. See 2016 Blomquist Report at www.nhtsa.gov/sites/nhtsa.gov/files/documents/expert_report-hrblomquist.pdf.Consequently, all frontal inflators using propellant 2004 that do not contain a "desiccant" (a substance that traps and holds moisture) in US vehicles are under recall. These "non-desiccated" inflators either have been or are required to be replaced.In some cases, the remedy part for these recalled inflators was, or will be, an inflator using either propellant 2004 or 2004L that does contain a desiccant. None of these "desiccated" remedy parts (which were installed in older model year vehicles) are currently under recall for a degradation concern. Certain subsets of desiccated PSAN inflators using propellant 2004 for use as original equipment, however, have been recalled for a degradation concern. All Takata inflators produced with propellant 2004L contain desiccant, and none of these desiccated inflators using propellant 2004L are under recall for a degradation concern. There have been no reported field ruptures in any non-recalled desiccated PSAN inflators.It is understood that desiccants fully saturate at some threshold, at which point any additional moisture will not be captured. This means the degradation process observed in non-desiccated inflators using propellant 2004 may also occur in non-recalled desiccated inflators using propellant 2004, assuming additional moisture enters the inflator and high temperature cycling occurs. Based on available information, desiccant saturation can occur within the first five years in the worst environments, and the time required for full saturation is affected by multiple factors. While no present safety risk has been identified, further work is needed to evaluate the future risk of non-recalled desiccated inflators using propellant 2004.Three entities -- Takata (now known as TK Global), the Independent Testing Coalition, and Exponent -- have been studying the long-term behavior of Takata desiccated PSAN inflators using propellant 2004L (as well as 2004) in the presence of moisture and temperature cycling. The research efforts, which include development of predictive modeling techniques and field sample analysis, are ongoing. To date, none of the researchers have identified field evidence showing that propellant 2004L is undergoing a degradation process that leads to aggressive deployment and potential rupture. However, the time in service of such inflators remains short compared to that of the inflators using propellant 2004. Further study is needed to assess the long-term safety of desiccated inflators using propellant 2004L.The Office of Defects Investigation is opening this investigation to examine whether a safety defect related to propellant degradation exists in non-recalled desiccated PSAN frontal inflators manufactured by Takata. This investigation will require extensive information on Takata production processes and surveys of inflators in the field. Lists of recall actions that may have used desiccated PSAN inflators as remedy parts, as well as the makes and models originally manufactured with them, is available with the downloadable version of this document (see nhtsa.gov/recalls?nhtsaId=EA21002 -- note this information is subject to change/revision as the investigation proceeds). This investigation does not supersede EA15-001, which remains open.

Additional source detail variants (2)

Air Bags:frontal:driver Side:inflator Module

From 2000 through 2017, Takata produced millions of air bag inflators using two types of phase-stabilized ammonium nitrate ("PSAN") propellant -- propellant 2004 and propellant 2004L. After prolonged exposure to high temperature cycles and humidity, inflators using propellant 2004 can degrade, causing the propellant to burn too quickly when ignited. The rapid burning can cause the inflator to rupture during deployment, potentially causing serious or even fatal injury to vehicle occupants. See 2016 Blomquist Report at www.nhtsa.gov/sites/nhtsa.gov/files/documents/expert_report-hrblomquist.pdf.Consequently, all frontal inflators using propellant 2004 that do not contain a "desiccant" (a substance that traps and holds moisture) in US vehicles are under recall. These "non-desiccated" inflators either have been or are required to be replaced.In some cases, the remedy part for these recalled inflators was, or will be, an inflator using either propellant 2004 or 2004L that does contain a desiccant. None of these "desiccated" remedy parts (which were installed in older model year vehicles) are currently under recall for a degradation concern. Certain subsets of desiccated PSAN inflators using propellant 2004 for use as original equipment, however, have been recalled for a degradation concern. All Takata inflators produced with propellant 2004L contain desiccant, and none of these desiccated inflators using propellant 2004L are under recall for a degradation concern. There have been no reported field ruptures in any non-recalled desiccated PSAN inflators.It is understood that desiccants fully saturate at some threshold, at which point any additional moisture will not be captured. This means the degradation process observed in non-desiccated inflators using propellant 2004 may also occur in non-recalled desiccated inflators using propellant 2004, assuming additional moisture enters the inflator and high temperature cycling occurs. Based on available information, desiccant saturation can occur within the first five years in the worst environments, and the time required for full saturation is affected by multiple factors. While no present safety risk has been identified, further work is needed to evaluate the future risk of non-recalled desiccated inflators using propellant 2004.Three entities -- Takata (now known as TK Global), the Independent Testing Coalition, and Exponent -- have been studying the long-term behavior of Takata desiccated PSAN inflators using propellant 2004L (as well as 2004) in the presence of moisture and temperature cycling. The research efforts, which include development of predictive modeling techniques and field sample analysis, are ongoing. To date, none of the researchers have identified field evidence showing that propellant 2004L is undergoing a degradation process that leads to aggressive deployment and potential rupture. However, the time in service of such inflators remains short compared to that of the inflators using propellant 2004. Further study is needed to assess the long-term safety of desiccated inflators using propellant 2004L.The Office of Defects Investigation is opening this investigation to examine whether a safety defect related to propellant degradation exists in non-recalled desiccated PSAN frontal inflators manufactured by Takata. This investigation will require extensive information on Takata production processes and surveys of inflators in the field. Lists of recall actions that may have used desiccated PSAN inflators as remedy parts, as well as the makes and models originally manufactured with them, is available with the downloadable version of this document (see nhtsa.gov/recalls?nhtsaId=EA21002 -- note this information is subject to change/revision as the investigation proceeds). This investigation does not supersede EA15-001, which remains open.

Air Bags:frontal:passenger Side:inflator Module

From 2000 through 2017, Takata produced millions of air bag inflators using two types of phase-stabilized ammonium nitrate ("PSAN") propellant -- propellant 2004 and propellant 2004L. After prolonged exposure to high temperature cycles and humidity, inflators using propellant 2004 can degrade, causing the propellant to burn too quickly when ignited. The rapid burning can cause the inflator to rupture during deployment, potentially causing serious or even fatal injury to vehicle occupants. See 2016 Blomquist Report at www.nhtsa.gov/sites/nhtsa.gov/files/documents/expert_report-hrblomquist.pdf.Consequently, all frontal inflators using propellant 2004 that do not contain a "desiccant" (a substance that traps and holds moisture) in US vehicles are under recall. These "non-desiccated" inflators either have been or are required to be replaced.In some cases, the remedy part for these recalled inflators was, or will be, an inflator using either propellant 2004 or 2004L that does contain a desiccant. None of these "desiccated" remedy parts (which were installed in older model year vehicles) are currently under recall for a degradation concern. Certain subsets of desiccated PSAN inflators using propellant 2004 for use as original equipment, however, have been recalled for a degradation concern. All Takata inflators produced with propellant 2004L contain desiccant, and none of these desiccated inflators using propellant 2004L are under recall for a degradation concern. There have been no reported field ruptures in any non-recalled desiccated PSAN inflators.It is understood that desiccants fully saturate at some threshold, at which point any additional moisture will not be captured. This means the degradation process observed in non-desiccated inflators using propellant 2004 may also occur in non-recalled desiccated inflators using propellant 2004, assuming additional moisture enters the inflator and high temperature cycling occurs. Based on available information, desiccant saturation can occur within the first five years in the worst environments, and the time required for full saturation is affected by multiple factors. While no present safety risk has been identified, further work is needed to evaluate the future risk of non-recalled desiccated inflators using propellant 2004.Three entities -- Takata (now known as TK Global), the Independent Testing Coalition, and Exponent -- have been studying the long-term behavior of Takata desiccated PSAN inflators using propellant 2004L (as well as 2004) in the presence of moisture and temperature cycling. The research efforts, which include development of predictive modeling techniques and field sample analysis, are ongoing. To date, none of the researchers have identified field evidence showing that propellant 2004L is undergoing a degradation process that leads to aggressive deployment and potential rupture. However, the time in service of such inflators remains short compared to that of the inflators using propellant 2004. Further study is needed to assess the long-term safety of desiccated inflators using propellant 2004L.The Office of Defects Investigation is opening this investigation to examine whether a safety defect related to propellant degradation exists in non-recalled desiccated PSAN frontal inflators manufactured by Takata. This investigation will require extensive information on Takata production processes and surveys of inflators in the field. Lists of recall actions that may have used desiccated PSAN inflators as remedy parts, as well as the makes and models originally manufactured with them, is available with the downloadable version of this document (see nhtsa.gov/recalls?nhtsaId=EA21002 -- note this information is subject to change/revision as the investigation proceeds). This investigation does not supersede EA15-001, which remains open.