← New search

2012 Chevrolet Silverado 1500

Owner reports · Recalls · Investigations

Similar to other model years

Owner complaints for the 2012 Chevrolet Silverado 1500 do not stand out strongly from the model-year median of 525.

About this comparison →

When problems were reported

Mileage at the reported incident

122 reports with mileage · 94 unknown

NHTSA’s mileage field refers to the reported incident, not necessarily the filing date. This shows report counts, not the likelihood of a failure.

What to inspect

Issues worth paying extra attention to based on owner reports.

  • Air Bags. Review the 59 owner reports in this category and discuss these concerns during a pre-purchase inspection. Read reports →
  • Structure. Review the 35 owner reports in this category and discuss these concerns during a pre-purchase inspection. Read reports →
  • Engine. Review the 25 owner reports in this category and discuss these concerns during a pre-purchase inspection. Read reports →

NHTSA owner reports · September 18, 2026 snapshot.

7 crash reports1 fire reports5 injury reports

What owners actually said

216 reports
125,000 miles · Mar 15, 2021
Engine

TL* THE CONTACT OWNS A 2012 CHEVROLET SILVERADO 1500. THE CONTACT STATED THAT WHILE DRIVING AT VARIOUS SPEEDS, THE VEHICLE WAS CONSUMING AN EXCESSIVE AMOUNT OF OIL. THE OIL INDICATOR WARNING LIGHT WAS ILLUMINATED. THE CONTACT CHECKED THE OIL DIPSTICK AND NOTICE NO INDICATION OF OIL ON THE DIPSTICK. THE VEHICLE WAS TAKEN TO BURNS…

Read full complaint

TL* THE CONTACT OWNS A 2012 CHEVROLET SILVERADO 1500. THE CONTACT STATED THAT WHILE DRIVING AT VARIOUS SPEEDS, THE VEHICLE WAS CONSUMING AN EXCESSIVE AMOUNT OF OIL. THE OIL INDICATOR WARNING LIGHT WAS ILLUMINATED. THE CONTACT CHECKED THE OIL DIPSTICK AND NOTICE NO INDICATION OF OIL ON THE DIPSTICK. THE VEHICLE WAS TAKEN TO BURNS CHEVROLET (2515 CHERRY RD, ROCK HILL, SC 29732, (803) 392-4180) WHERE AN OIL CONSUMPTION TEST WAS PROVIDED AND DIAGNOSED THAT THE ENGINE NEEDED TO BE REBUILT. THE VEHICLE WAS NOT REPAIRED. THE MANUFACTURER WAS NOTIFIED OF THE FAILURE. THE FAILURE MILEAGE WAS APPROXIMATELY 125,000.

NHTSA ODI #11403059

50,000 miles · Mar 4, 2021
Air BagsElectrical SystemStructureCrashInjury

TTHIS VEHICLE WAS INVOLVED IN 3 SEPARATE ACCIDENTS, 1ST ANOTHER DRIVER PULLED OUT IN FRONT OF THE TRUCK CAUSING THE ACCIDENT; 2ND A DRIVER FELL ASLEEP WITH HIS FOOT ON THE ACCELERATOR AND REAR ENDED ME AT ABOUT 90 MPH; 3RD AN OUT STATE DRIVER REAR ENDED MY SON'S CAR WHICH WAS FORCED INTO THE REAR OF MY TRUCK. THE 3 ACCIDENTS WER…

Read full complaint

TTHIS VEHICLE WAS INVOLVED IN 3 SEPARATE ACCIDENTS, 1ST ANOTHER DRIVER PULLED OUT IN FRONT OF THE TRUCK CAUSING THE ACCIDENT; 2ND A DRIVER FELL ASLEEP WITH HIS FOOT ON THE ACCELERATOR AND REAR ENDED ME AT ABOUT 90 MPH; 3RD AN OUT STATE DRIVER REAR ENDED MY SON'S CAR WHICH WAS FORCED INTO THE REAR OF MY TRUCK. THE 3 ACCIDENTS WERE SEVERE ENOUGH THAT THERE SHOULD HAVE BEEN SOME TYPE OF AIR BAG DEPLOYMENT BUT THERE WAS NOT. I NOTIFIED GM IMMEDIATELY AFTER THE 1ST ACCIDENT ABOUT THE FAILURE OF THE AIR BAGS TO DEPLOY. I SHOULD MENTIONED THAT THE DRIVER'S SEAT BELT BROKE DUE THE HARSHNESS OF THE ACCIDENT. ALL THIS HAPPENED SEVERAL YEARS AGO BUT GM NEVER ANSWERED ME NOR TOOK ANY ACTION TO INVESTIGATE THE FAILURE OF THE AIR BAGS TO DEPLOY. TODAY, 4 MARCH, I RECEIVED A RECALL NOTICE BECAUSE AFTER ALL THESE YEARS TAKATA HAS ADMITTED THERE IS A PROBLEM WITH THE BAGS, EXCEPT THEY SAY IT IS ONLY THE PASSENGER AIR BAG. TO TELL YOU THE TRUTH I DIDN'T EVEN THINK I HAD AIR BAGS BECAUSE THEY NEVER WORKED. THE ID NUMBER FOR THIS RECALL IS 21V051. I AM HOPEFUL THAT EVEN THOUGH THESE ACCIDENTS TOOK PLACE YEARS AGO, I DON'T HAVE ACTUAL DATES BECAUSE I DIDN'T THEY WERE IMPORTANT, THAT YOU, AS THE FEDERAL AGENCY RESPONSIBLE FOR OVERSEEING THE SAFETY OF CARS USING OUR HIGHWAYS, WILL INQUIRE AS TO WHY GM FAILED TO INVESTIGATE A SAFETY COMPLAINT SUBMITTED TO THEIR CUSTOMER ASSISTANCE CENTER. HAVING SOME ADMINISTRATION KNOWLEDGE I AM SURE THERE HAS TO BE A FILE FOLDER WITH MY COMPLAINT IN IT. THANK YOU AND PLEASE HELP ME? * (RECALL RELATED INCIDENT) TS

NHTSA ODI #11399221

159,000 miles · Mar 2, 2021
Electrical SystemFuel/propulsion SystemPower Train

TRACTION GOES OFF. STEERING WHEEL LOCKS UP AND ENGINE SHUTS OFF AFTER ALL THE WARNING LIGHTS COME ON. YOUR NO LONGER ABLE TO PICK UP SPEED OR STEER THE TRUCK.

NHTSA ODI #11398801

Mileage unknown · Mar 2, 2021
Air Bags

2012 CHEVROLET SILVERADO. CONSUMER WRITES IN REGARDS TO AIR BAG SAFETY RECALL. *LD THE CONSUMER STATED THE DEALER AND MANUFACTURER DID NOT HONOR THE RECALL. THE CONSUMER WAS CHARGED A DIAGNOSTIC FEE AND FOR SERVICING THE AIRBAG. *JS

NHTSA ODI #11398393

191,548 miles · Feb 12, 2021
Air Bags

TL* TAKATA RECALL. THE CONTACT OWNS A 2012 CHEVROLET SILVERADO 1500. THE CONTACT RECEIVED NOTIFICATION OF NHTSA CAMPAIGN NUMBER: 21V054000 (AIR BAGS). THE CONTACT STATED THAT WHILE DRIVING AT VARIOUS SPEEDS, THE AIR BAG WARNING LIGHT ILLUMINATED. THE VEHICLE WAS TAKEN TO DUKE CHEVROLET BUICK GMC CADILLAC (2016 N MAIN ST, SUFFOLK…

Read full complaint

TL* TAKATA RECALL. THE CONTACT OWNS A 2012 CHEVROLET SILVERADO 1500. THE CONTACT RECEIVED NOTIFICATION OF NHTSA CAMPAIGN NUMBER: 21V054000 (AIR BAGS). THE CONTACT STATED THAT WHILE DRIVING AT VARIOUS SPEEDS, THE AIR BAG WARNING LIGHT ILLUMINATED. THE VEHICLE WAS TAKEN TO DUKE CHEVROLET BUICK GMC CADILLAC (2016 N MAIN ST, SUFFOLK, VA 23434, (757)539-8777) FOR THE RECALL REPAIR HOWEVER, THE TECHNICIAN INFORMED THE CONTACT THAT THE DRIVER'S SIDE AIR BAG NEEDED TO BE REPLACED. THE FRONT PASSENGER'S SIDE AIR BAG WAS REPLACED. THE FAILURE RECURRED. THE MANUFACTURER WAS NOT NOTIFIED OF THE FAILURE. THE FAILURE MILEAGE WAS APPROXIMATELY 191,548.

NHTSA ODI #11395930

50,985 miles · Feb 3, 2021
Structure

IN FEBRUARY 2020 THE EXTERIOR DOOR HANDLE ON THE FRONT DRIVER SIDE DOOR BROKE AND HAD TO BE REPLACED AT A COST TO ME OF $163.73. NOW THE EXTERIOR HANDLE ON THE FRONT PASSENGER DOOR IS BROKEN AND HAS TO BE REPLACED. IN BOTH CASES THE HANDLE BECAME DETACHED ON THE INSIDE OF THE DOOR FRAME.

NHTSA ODI #11394495

76,000 miles · Jan 25, 2021
Unknown Or Other

DASH BOARD CRACKS HAVE OCCURRED AT APPROXIMATELY 75K MILES AT THE CORNER OF PASSENGER AIRBAG AND OVER INSTRUMENT CLUSTER. THESE ARE FAIRLY COMMON FOR A MULTI-YEAR GROUP OF GM VEHICLES AND WAS INVOLVED IN A NOW DISMISSED CLASS ACTION SUIT. IT MAY/MAY NOT EVENTUALLY AFFECT THE INSTRUMENT CLUSTER, AND MAY/MAY NOT AFFECT PASSENGER …

Read full complaint

DASH BOARD CRACKS HAVE OCCURRED AT APPROXIMATELY 75K MILES AT THE CORNER OF PASSENGER AIRBAG AND OVER INSTRUMENT CLUSTER. THESE ARE FAIRLY COMMON FOR A MULTI-YEAR GROUP OF GM VEHICLES AND WAS INVOLVED IN A NOW DISMISSED CLASS ACTION SUIT. IT MAY/MAY NOT EVENTUALLY AFFECT THE INSTRUMENT CLUSTER, AND MAY/MAY NOT AFFECT PASSENGER AIRBAG DEPLOYMENT. IT MAY/MAY NOT RESULT IN FURTHER INJURY IF DASH COMES APART IN ACCIDENT. COST TO REPLACE AT LOCAL DEALER IS APPROXIMATELY $800 FOR PARTS AND LABOR. NOT COVERED BY ORIGINAL MANUFACTURER WARRANTY DUE TO MILEAGE OR COMPREHENSIVE EXTENDED WARRANTY CURRENTLY IN FORCE. PLANNING TO REPLACE BUT NOT HAPPY ABOUT IT. GM SHOULD HAVE RECALLED OR OFFER TO AT LEAST SPLIT COSTS.

NHTSA ODI #11389835

90,000 miles · Jan 15, 2021
Electrical SystemCrash

TL* THE CONTACT OWNS A 2012 CHEVROLET SILVERADO 1500. THE CONTACT THAT STATED THAT WHILE DRIVING AT VARIOUS SPEEDS MAKING A RIGHT TURN, THE VEHICLE SEIZED FOR ABOUT 2-3 SECONDS WHICH CAUSED THE CONTACT TO LOSS CONTROL OF THE STEERING WHEEL. THE CONTACT TRIED TO DEPRESSED THE BRAKE PEDAL WHICH TRAVELED TO THE FLOORBOARD. WITHIN …

Read full complaint

TL* THE CONTACT OWNS A 2012 CHEVROLET SILVERADO 1500. THE CONTACT THAT STATED THAT WHILE DRIVING AT VARIOUS SPEEDS MAKING A RIGHT TURN, THE VEHICLE SEIZED FOR ABOUT 2-3 SECONDS WHICH CAUSED THE CONTACT TO LOSS CONTROL OF THE STEERING WHEEL. THE CONTACT TRIED TO DEPRESSED THE BRAKE PEDAL WHICH TRAVELED TO THE FLOORBOARD. WITHIN A FEW SECONDS, THE VEHICLE RESUMED BACK TO NORMAL AS THE CONTACT REGAINED CONTROL CRASHING INTO A TELEPHONE POLE KNOCKING IT COMPLETELY DOWN. THE AIR BAG WARNING LIGHT ILLUMINATED. NO AIR BAGS DEPLOYED. THE CONTACT DID NOT SUSTAIN INJURIES. A POLICE REPORT WAS FILED. NO MEDICAL ATTENTION WAS CONTACTED. THE VEHICLE WAS TOWED TO YOUNG VW MAZDA 191 COMMERCE PARK DR, EASTON, PA 18045 (610) 991-9100 WHERE IT WAS DIAGNOSED, HOWEVER, UNABLE TO DUPLICATE THE ISSUE. THE TECHNICIAN REPLACED THE FRONT BUMPER. THE FAILURE RECURRED. THE CONTACT MENTIONED NHTSA CAMPAIGN NUMBER: 14V827000 (ELECTRICAL SYSTEM) AS A POSSIBLE SOLUTION TO THE FAILURE HOWEVER THE VIN WAS NOT INCLUDED. THE MANUFACTURER WAS NOT NOTIFIED OF THE FAILURE. THE FAILURE MILEAGE WAS APPROXIMATELY 90,000.

NHTSA ODI #11388374

138,319 miles · Dec 25, 2020
Engine

ENGINE USING 1 TO 2 QUARTS OF OIL EACH OIL CHANGE (I DO CHECK LEVEL AT TIME OF EACH GAS REFUELING) THIS PROBLEM WAS DOCUMENTED AT THE SERVICE DEPARTMENT, TOM TEPE AUTO CENTER, CHEVROLET DEALER IN MILAN, INDIANA DENNIS MURPHY MANAGER812-654-3001 MILAGE IN AT THE TIME WAS 13831, ISSUE STILL EXISTS!

NHTSA ODI #11384909

50,513 miles · Dec 16, 2020
Seat BeltsInjury

12/15/2020 - NOTICED 'SERVICE AIR BAG' WARNING IN MORNING AS I PULLED INTO PARKING FOR WORK. WHEN LEAVING FOR LUNCH NO WARNING ON - AS I PULLED OUT OF PARKING WARNING APPEARED AGAIN - AS I LEANED FORWARD TO READ - LOUD 'BANG' AND WAS PULLED BACK INTO SEAT BY HARD RETRACTION OF SEATBELT. FOLLOWED BY SMELL OF BURNING. PARKED CAR…

Read full complaint

12/15/2020 - NOTICED 'SERVICE AIR BAG' WARNING IN MORNING AS I PULLED INTO PARKING FOR WORK. WHEN LEAVING FOR LUNCH NO WARNING ON - AS I PULLED OUT OF PARKING WARNING APPEARED AGAIN - AS I LEANED FORWARD TO READ - LOUD 'BANG' AND WAS PULLED BACK INTO SEAT BY HARD RETRACTION OF SEATBELT. FOLLOWED BY SMELL OF BURNING. PARKED CAR, STRUGGLED TO GET OUT OF SEATBELT - LOOKED AROUND FOR DAMAGE - NOTHING - ONLY SEATBELTS STUCK RETRACTED. DROVE HOME CAREFULLY - PLUGGED IN OBD 2 READER - FOUR CODES; B0015-04, B0022-00, B0052-04, B101D-00. FIRST TWO INDICATE SEAT BELT PRETENSIONER DEPLOYED, THIRD IS DEPLOYMENT COMMAND, FINAL IS ECU HARDWARE. TOOK TO ASE SHOP AND WAS INFORMED THAT THE CONTROL UNIT INDICATED A COLLISION - THERE WAS NO COLLISION - AND BELTS WERE DEPLOYED. ASKED WHAT CAUSED THIS AND RESPONSE WAS COMPUTER ERROR....I AM JUST THANKFUL I WAS MOVING AT 5 MPH VICE 65 ON THE HIGHWAY. GONNA COST $2500 TO FIX REPLACING SEATBELTS AND SRS CONTROL UNIT, AND A FEW DAY TO GET OVER A BRUISED SHOULDER

NHTSA ODI #11383669

Official recalls

2

21V051000 · Air Bags:frontal:passenger Side:inflator Module

Feb 5, 2021

General Motors, LLC (GM) is recalling certain 2012 Cadillac Escalade, Escalade ESV, Escalade EXT, Chevrolet Avalanche, Silverado 1500, Silverado 2500/3500, Suburban, Tahoe, GMC Sierra 1500, Sierra 2500/3500, Yukon, and Yukon XL originally sold, or ever registered, in the states of Alabama, California, Florida, Georgia, Hawaii, Louisiana, Mississippi, South Carolina, Texas, Puerto Rico, American Samoa, Guam, the Northern Mariana Islands (Saipan), and the U.S. Virgin Islands or "Zone A." These vehicles are equipped with non-desiccated passenger frontal inflators containing phase-stabilized ammonium nitrate (PSAN) propellant. These inflators may explode due to propellant degradation occurring after long-term exposure to high absolute humidity, high temperatures, and high temperature cycling.

Consequence & remedy

Consequence: An inflator explosion may result in sharp metal fragments striking the driver or other occupants, resulting in serious injury or death.

Remedy: GM will notify owners, and dealers will replace the front passenger air bag inflator with an alternate one, free of charge. Interim letters notifying owners of the safety risk were mailed on February 22, 2021. Second notification letters will be mailed once the remedy is available. Owner notification letters were mailed on May 11, 2021. Owners may contact Cadillac customer service at 1-800-458-8006; Chevrolet customer service at 1-800-222-1020; and GMC customer service at 1-800-462-8782. GM's number for this recall is N212328770.

21V054000 · Air Bags:frontal:passenger Side:inflator Module

Feb 5, 2021

General Motors, LLC (GM) is recalling certain 2014 Cadillac Escalade, Escalade ESV, Chevrolet Silverado 2500, Silverado 3500, Suburban, Tahoe, GMC Sierra 2500, Sierra 3500, Yukon, and Yukon XL vehicles originally sold, or ever registered, in the states of AL, CA, FL, GA, HI, LA, MS, SC, TX, PR, AS, GU, the MP, and VI or "Zone A." Additionally GM is recalling certain 2011-2014 Cadillac Escalade, Escalade ESV, Chevrolet Silverado 2500, Silverado 3500, Suburban, Tahoe, GMC Sierra 2500, Sierra 3500, Yukon, Yukon XL and 2011-2013 Cadillac Escalade EXT, Chevrolet Avalanche, Silverado 1500, and GMC Sierra 1500 vehicles originally sold, or ever registered, in the states of AZ, AR, DE, DC, IL, IN, KS, KY, MD, MO, NE, NV, NJ, NM, NC, OH, OK, PA, TN, VA, and WV or "Zone B." Additionally, GM is recalling certain 2010-2014 Cadillac Escalade, Escalade ESV, Chevrolet Silverado 2500, Silverado 3500, Suburban, Tahoe, GMC Sierra 2500, Sierra 3500, Yukon, and Yukon XL and 2010-2013 Cadillac Escalade EXT, Chevrolet Avalanche, Silverado 1500, and GMC Sierra 1500 vehicles originally sold, or ever registered, in the states of AK, CO, CT, ID, IA, ME, MA, MI, MN, MT, NH, NY, ND, OR, RI, SD, UT, VT, WA, WI, and WY or "Zone C." These vehicles are equipped with non-desiccated passenger frontal inflators containing phase-stabilized ammonium nitrate (PSAN) propellant. These inflators may explode due to propellant degradation occurring after long-term exposure to high absolute humidity, high temperatures, and high temperature cycling.

Consequence & remedy

Consequence: An inflator explosion may result in sharp metal fragments striking the driver or other occupants, resulting in serious injury or death.

Remedy: GM will notify owners, and dealers will replace the front passenger air bag inflator with an alternate one, free of charge. Interim letters notifying owners of the safety risk were mailed on February 25, 2021. Second notification letters will be mailed once the remedy is available. Owner notification letters were mailed to 40 VIN owners on May 11, 2021. A second owner notification letter was mailed to all other owners on January 24, 2022. Owners may contact Chevrolet customer service at 1-800-222-1020; Cadillac customer service at 1-800-458-8006; and GMC customer service at 1-800-462-8782. GM's number for this recall is N212328800.

Model-level recall history does not show whether a particular VIN is affected or has received a repair. Check a VIN with NHTSA ↗

NHTSA investigations

2

DP22005 · Pedestrian Alert Sounds

Opened Jan 27, 2023 · Closed Aug 7, 2023

Status: closed (inferred from source dates) · Electrical System:propulsion System

NHTSA received a petition on or about July 18, 2022, requesting that Federal Motor Vehicle Safety Standard (FMVSS) 141 be applied to all electric and hybrid vehicles operating in the United States. The petition can be reviewed at NHTSA.gov under ODI Number 11486072. FMVSS 141 establishes performance requirements for pedestrian alert sounds for motor vehicles. The standard applies to hybrid and electric vehicles that have a gross vehicle weight rating of 4,536 KG or less or are defined as low-speed vehicles. The standard became fully applicable to all such vehicles manufactured on or after March 1, 2021.On January 27, 2023, NHTSA opened Defect Petition (DP) 22-005 to evaluate the subject matter described in the petition. On June 24, 2023 and as supplemented on June 25, 2023, the petitioner notified NHTSA he was withdrawing his petition. The petitioner indicated that, based on his review of data, there is no justification for asserting potential benefits that could be derived from actions sought by my petition. Based on the petitioner's withdrawal, DP22-005 is closed. Closure of this DP does not represent a determination by NHTSA regarding the subject matter of the petition.

EA21002 · Desiccated Air Bag Inflator Rupture

Opened Sep 17, 2021 · No close date supplied

Status: open (inferred from source dates) · Air Bags:frontal:driver Side:inflator Module; Air Bags:frontal:passenger Side:inflator Module

From 2000 through 2017, Takata produced millions of air bag inflators using two types of phase-stabilized ammonium nitrate ("PSAN") propellant -- propellant 2004 and propellant 2004L. After prolonged exposure to high temperature cycles and humidity, inflators using propellant 2004 can degrade, causing the propellant to burn too quickly when ignited. The rapid burning can cause the inflator to rupture during deployment, potentially causing serious or even fatal injury to vehicle occupants. See 2016 Blomquist Report at www.nhtsa.gov/sites/nhtsa.gov/files/documents/expert_report-hrblomquist.pdf.Consequently, all frontal inflators using propellant 2004 that do not contain a "desiccant" (a substance that traps and holds moisture) in US vehicles are under recall. These "non-desiccated" inflators either have been or are required to be replaced.In some cases, the remedy part for these recalled inflators was, or will be, an inflator using either propellant 2004 or 2004L that does contain a desiccant. None of these "desiccated" remedy parts (which were installed in older model year vehicles) are currently under recall for a degradation concern. Certain subsets of desiccated PSAN inflators using propellant 2004 for use as original equipment, however, have been recalled for a degradation concern. All Takata inflators produced with propellant 2004L contain desiccant, and none of these desiccated inflators using propellant 2004L are under recall for a degradation concern. There have been no reported field ruptures in any non-recalled desiccated PSAN inflators.It is understood that desiccants fully saturate at some threshold, at which point any additional moisture will not be captured. This means the degradation process observed in non-desiccated inflators using propellant 2004 may also occur in non-recalled desiccated inflators using propellant 2004, assuming additional moisture enters the inflator and high temperature cycling occurs. Based on available information, desiccant saturation can occur within the first five years in the worst environments, and the time required for full saturation is affected by multiple factors. While no present safety risk has been identified, further work is needed to evaluate the future risk of non-recalled desiccated inflators using propellant 2004.Three entities -- Takata (now known as TK Global), the Independent Testing Coalition, and Exponent -- have been studying the long-term behavior of Takata desiccated PSAN inflators using propellant 2004L (as well as 2004) in the presence of moisture and temperature cycling. The research efforts, which include development of predictive modeling techniques and field sample analysis, are ongoing. To date, none of the researchers have identified field evidence showing that propellant 2004L is undergoing a degradation process that leads to aggressive deployment and potential rupture. However, the time in service of such inflators remains short compared to that of the inflators using propellant 2004. Further study is needed to assess the long-term safety of desiccated inflators using propellant 2004L.The Office of Defects Investigation is opening this investigation to examine whether a safety defect related to propellant degradation exists in non-recalled desiccated PSAN frontal inflators manufactured by Takata. This investigation will require extensive information on Takata production processes and surveys of inflators in the field. Lists of recall actions that may have used desiccated PSAN inflators as remedy parts, as well as the makes and models originally manufactured with them, is available with the downloadable version of this document (see nhtsa.gov/recalls?nhtsaId=EA21002 -- note this information is subject to change/revision as the investigation proceeds). This investigation does not supersede EA15-001, which remains open.

Additional source detail variants (2)

Air Bags:frontal:driver Side:inflator Module

From 2000 through 2017, Takata produced millions of air bag inflators using two types of phase-stabilized ammonium nitrate ("PSAN") propellant -- propellant 2004 and propellant 2004L. After prolonged exposure to high temperature cycles and humidity, inflators using propellant 2004 can degrade, causing the propellant to burn too quickly when ignited. The rapid burning can cause the inflator to rupture during deployment, potentially causing serious or even fatal injury to vehicle occupants. See 2016 Blomquist Report at www.nhtsa.gov/sites/nhtsa.gov/files/documents/expert_report-hrblomquist.pdf.Consequently, all frontal inflators using propellant 2004 that do not contain a "desiccant" (a substance that traps and holds moisture) in US vehicles are under recall. These "non-desiccated" inflators either have been or are required to be replaced.In some cases, the remedy part for these recalled inflators was, or will be, an inflator using either propellant 2004 or 2004L that does contain a desiccant. None of these "desiccated" remedy parts (which were installed in older model year vehicles) are currently under recall for a degradation concern. Certain subsets of desiccated PSAN inflators using propellant 2004 for use as original equipment, however, have been recalled for a degradation concern. All Takata inflators produced with propellant 2004L contain desiccant, and none of these desiccated inflators using propellant 2004L are under recall for a degradation concern. There have been no reported field ruptures in any non-recalled desiccated PSAN inflators.It is understood that desiccants fully saturate at some threshold, at which point any additional moisture will not be captured. This means the degradation process observed in non-desiccated inflators using propellant 2004 may also occur in non-recalled desiccated inflators using propellant 2004, assuming additional moisture enters the inflator and high temperature cycling occurs. Based on available information, desiccant saturation can occur within the first five years in the worst environments, and the time required for full saturation is affected by multiple factors. While no present safety risk has been identified, further work is needed to evaluate the future risk of non-recalled desiccated inflators using propellant 2004.Three entities -- Takata (now known as TK Global), the Independent Testing Coalition, and Exponent -- have been studying the long-term behavior of Takata desiccated PSAN inflators using propellant 2004L (as well as 2004) in the presence of moisture and temperature cycling. The research efforts, which include development of predictive modeling techniques and field sample analysis, are ongoing. To date, none of the researchers have identified field evidence showing that propellant 2004L is undergoing a degradation process that leads to aggressive deployment and potential rupture. However, the time in service of such inflators remains short compared to that of the inflators using propellant 2004. Further study is needed to assess the long-term safety of desiccated inflators using propellant 2004L.The Office of Defects Investigation is opening this investigation to examine whether a safety defect related to propellant degradation exists in non-recalled desiccated PSAN frontal inflators manufactured by Takata. This investigation will require extensive information on Takata production processes and surveys of inflators in the field. Lists of recall actions that may have used desiccated PSAN inflators as remedy parts, as well as the makes and models originally manufactured with them, is available with the downloadable version of this document (see nhtsa.gov/recalls?nhtsaId=EA21002 -- note this information is subject to change/revision as the investigation proceeds). This investigation does not supersede EA15-001, which remains open.

Air Bags:frontal:passenger Side:inflator Module

From 2000 through 2017, Takata produced millions of air bag inflators using two types of phase-stabilized ammonium nitrate ("PSAN") propellant -- propellant 2004 and propellant 2004L. After prolonged exposure to high temperature cycles and humidity, inflators using propellant 2004 can degrade, causing the propellant to burn too quickly when ignited. The rapid burning can cause the inflator to rupture during deployment, potentially causing serious or even fatal injury to vehicle occupants. See 2016 Blomquist Report at www.nhtsa.gov/sites/nhtsa.gov/files/documents/expert_report-hrblomquist.pdf.Consequently, all frontal inflators using propellant 2004 that do not contain a "desiccant" (a substance that traps and holds moisture) in US vehicles are under recall. These "non-desiccated" inflators either have been or are required to be replaced.In some cases, the remedy part for these recalled inflators was, or will be, an inflator using either propellant 2004 or 2004L that does contain a desiccant. None of these "desiccated" remedy parts (which were installed in older model year vehicles) are currently under recall for a degradation concern. Certain subsets of desiccated PSAN inflators using propellant 2004 for use as original equipment, however, have been recalled for a degradation concern. All Takata inflators produced with propellant 2004L contain desiccant, and none of these desiccated inflators using propellant 2004L are under recall for a degradation concern. There have been no reported field ruptures in any non-recalled desiccated PSAN inflators.It is understood that desiccants fully saturate at some threshold, at which point any additional moisture will not be captured. This means the degradation process observed in non-desiccated inflators using propellant 2004 may also occur in non-recalled desiccated inflators using propellant 2004, assuming additional moisture enters the inflator and high temperature cycling occurs. Based on available information, desiccant saturation can occur within the first five years in the worst environments, and the time required for full saturation is affected by multiple factors. While no present safety risk has been identified, further work is needed to evaluate the future risk of non-recalled desiccated inflators using propellant 2004.Three entities -- Takata (now known as TK Global), the Independent Testing Coalition, and Exponent -- have been studying the long-term behavior of Takata desiccated PSAN inflators using propellant 2004L (as well as 2004) in the presence of moisture and temperature cycling. The research efforts, which include development of predictive modeling techniques and field sample analysis, are ongoing. To date, none of the researchers have identified field evidence showing that propellant 2004L is undergoing a degradation process that leads to aggressive deployment and potential rupture. However, the time in service of such inflators remains short compared to that of the inflators using propellant 2004. Further study is needed to assess the long-term safety of desiccated inflators using propellant 2004L.The Office of Defects Investigation is opening this investigation to examine whether a safety defect related to propellant degradation exists in non-recalled desiccated PSAN frontal inflators manufactured by Takata. This investigation will require extensive information on Takata production processes and surveys of inflators in the field. Lists of recall actions that may have used desiccated PSAN inflators as remedy parts, as well as the makes and models originally manufactured with them, is available with the downloadable version of this document (see nhtsa.gov/recalls?nhtsaId=EA21002 -- note this information is subject to change/revision as the investigation proceeds). This investigation does not supersede EA15-001, which remains open.