Owner complaints for the 2012 Chevrolet Silverado 1500 do not stand out strongly from the model-year median of 525.

About this comparison →

When problems were reported

Mileage at the reported incident

122 reports with mileage · 94 unknown

NHTSA’s mileage field refers to the reported incident, not necessarily the filing date. This shows report counts, not the likelihood of a failure.

What to inspect

Issues worth paying extra attention to based on owner reports.

  • Air Bags. Review the 59 owner reports in this category and discuss these concerns during a pre-purchase inspection. Read reports →
  • Structure. Review the 35 owner reports in this category and discuss these concerns during a pre-purchase inspection. Read reports →
  • Engine. Review the 25 owner reports in this category and discuss these concerns during a pre-purchase inspection. Read reports →

NHTSA owner reports · September 18, 2026 snapshot.

7 crash reports1 fire reports5 injury reports

Unknown Or Other complaints

73 reports
Clear category filter
85,000 miles · May 3, 2019
Unknown Or OtherVisibility/wiper

NO PART AVAILABLE FOR THE CLIMATE CONTROL, WITH A MAIL IN PROCEDURE AND A 30 DAY TURN AROUND TIME. THIS CREATES A VISIBILITY HAZARD WHILE DRIVING. INABILITY TO CONTROL THE HEAT DURING COLDER CLIMATE WHILE CREATING FOGGY WINDOWS AND TRYING TO TRAVEL. THIS IS A SAFETY HAZARD FOR THE DRIVER AS WELL AS THE PUBLIC! I CANNOT TAKE THE …

Read full complaint

NO PART AVAILABLE FOR THE CLIMATE CONTROL, WITH A MAIL IN PROCEDURE AND A 30 DAY TURN AROUND TIME. THIS CREATES A VISIBILITY HAZARD WHILE DRIVING. INABILITY TO CONTROL THE HEAT DURING COLDER CLIMATE WHILE CREATING FOGGY WINDOWS AND TRYING TO TRAVEL. THIS IS A SAFETY HAZARD FOR THE DRIVER AS WELL AS THE PUBLIC! I CANNOT TAKE THE PART OUT FOR A MONTH BECAUSE I HAVE NO IDEA WHAT THE WEATHER WILL BE LIKE 10 MINUTES FROM NOW AND IF I DID WOULD BE WITHOUT FOR 30 DAYS AND NOT HAVE THE ABILITY TO CLEAR A FOGGY WINDSHIELD!

NHTSA ODI #11205433

100,000 miles · Feb 9, 2019
Air BagsUnknown Or Other

DASHBOARD CRACK ABOVE PASSENGER AIRBAG.

NHTSA ODI #11175953

64,000 miles · Jan 19, 2019
Unknown Or Other

TIRE MOUNTED UNDER VEHICLE IS NOT SAME SIZE AS TIRES IN USE, SAFETY QUESTION.

NHTSA ODI #11170937

40,000 miles · Dec 21, 2018
Unknown Or Other

THE COMMON DASH CRACKS. ONE TO THE TOP LEFT OF THE INSTRUMENT PANEL AND THE OTHER ALONG THE TOP OF THE AIRBAG ON THE PASSENGER SIDE.

NHTSA ODI #11163022

104,000 miles · Dec 11, 2018
StructureUnknown Or Other

DASH IS CRACKED IN MANY PLACES. VEHICLE HAS 113K MILES WAS BOUGHT THAT WAY IN MAY OF 17 WITH DASH CRACKED AT 104K MILES

NHTSA ODI #11160854

70,000 miles · Nov 16, 2018
Unknown Or Other

CRACKED DASH

NHTSA ODI #11152072

65,000 miles · Jun 6, 2018
Electronic Stability Control (esc)Unknown Or Other

THERE HAS BEEN VARIOUS OCCASIONS WHERE WE ARE DRIVING AND THE TRUCK STOPS WITH NO WARNING OR REASON, THE FIRST TIME WAS ON I-95 HIGHWAY IN PHILADELPHIA MID TRAFFIC THE TRUCK TURNED OFF AND WOULD NOT RESTART FOR ABOUT 5MINUTES WE WEEE STUCK IN THE MIDDLE OF THE ROAD BLOCKING TRAFFIC, NO CHECK ENGINE LIGHT OR ANY WARNING LIGHT CAM…

Read full complaint

THERE HAS BEEN VARIOUS OCCASIONS WHERE WE ARE DRIVING AND THE TRUCK STOPS WITH NO WARNING OR REASON, THE FIRST TIME WAS ON I-95 HIGHWAY IN PHILADELPHIA MID TRAFFIC THE TRUCK TURNED OFF AND WOULD NOT RESTART FOR ABOUT 5MINUTES WE WEEE STUCK IN THE MIDDLE OF THE ROAD BLOCKING TRAFFIC, NO CHECK ENGINE LIGHT OR ANY WARNING LIGHT CAME ON. THE SECOND TIME WAS JUST THIS WEEK ON THE WAY TO TWO DIFFERENT MECHANICS TO GET THE COMPUTER READ IT TURNED OFF YET AGAIN IN THE MIDDLE OF THE ROAD. BOTH MECHANICS SAID NOTHING CAN UP ON THE SCANNER WHEN CONNECTED AND THERE WERE NO CHECK ENGINE LIGHTS TURNED ON.

NHTSA ODI #11100174

Mileage unknown · Mar 27, 2018
Air BagsUnknown Or Other

CRACKED DASH ABOVE INSTRUMENT CLUSTER AND AT IT BAG. STARTED AT 48000 MILES. IF IN A WRECK AND AIR BAG DEPLOYS SHARDS OF DASH CAN FLY THROUGH THE AIR. THINGS CAN GET DOWN IN INSTRUMENT CLUSTER AND CAUSE A SHORT WHICH CAN LEAD TO A FIRE. VEHICLE CAN BE SITTING IN A HEATED GARAGE AND IT KEEPS GETTING WORSE

NHTSA ODI #11081464

60,500 miles · Mar 27, 2018
Unknown Or Other

I HAVE A CRACK IN MY DASHBOARD JUST ABOVE THE AIRBAG. THIS IS NOT DUE TO HEAT OR SUN THIS HAPPENED DURING THE WINTER IN ALASKA

NHTSA ODI #11081423

69,885 miles · Feb 23, 2018
Unknown Or Other

DASHBOARD CRACKED FROM PASSENGER AIRBAG TO FRONT EDGE OF PANEL. VEHICLE STATIONARY AND NOT RUNNING WHEN CRACK OCCURRED.

NHTSA ODI #11074496

Official recalls

2

21V051000 · Air Bags:frontal:passenger Side:inflator Module

Feb 5, 2021

General Motors, LLC (GM) is recalling certain 2012 Cadillac Escalade, Escalade ESV, Escalade EXT, Chevrolet Avalanche, Silverado 1500, Silverado 2500/3500, Suburban, Tahoe, GMC Sierra 1500, Sierra 2500/3500, Yukon, and Yukon XL originally sold, or ever registered, in the states of Alabama, California, Florida, Georgia, Hawaii, Louisiana, Mississippi, South Carolina, Texas, Puerto Rico, American Samoa, Guam, the Northern Mariana Islands (Saipan), and the U.S. Virgin Islands or "Zone A." These vehicles are equipped with non-desiccated passenger frontal inflators containing phase-stabilized ammonium nitrate (PSAN) propellant. These inflators may explode due to propellant degradation occurring after long-term exposure to high absolute humidity, high temperatures, and high temperature cycling.

Consequence & remedy

Consequence: An inflator explosion may result in sharp metal fragments striking the driver or other occupants, resulting in serious injury or death.

Remedy: GM will notify owners, and dealers will replace the front passenger air bag inflator with an alternate one, free of charge. Interim letters notifying owners of the safety risk were mailed on February 22, 2021. Second notification letters will be mailed once the remedy is available. Owner notification letters were mailed on May 11, 2021. Owners may contact Cadillac customer service at 1-800-458-8006; Chevrolet customer service at 1-800-222-1020; and GMC customer service at 1-800-462-8782. GM's number for this recall is N212328770.

21V054000 · Air Bags:frontal:passenger Side:inflator Module

Feb 5, 2021

General Motors, LLC (GM) is recalling certain 2014 Cadillac Escalade, Escalade ESV, Chevrolet Silverado 2500, Silverado 3500, Suburban, Tahoe, GMC Sierra 2500, Sierra 3500, Yukon, and Yukon XL vehicles originally sold, or ever registered, in the states of AL, CA, FL, GA, HI, LA, MS, SC, TX, PR, AS, GU, the MP, and VI or "Zone A." Additionally GM is recalling certain 2011-2014 Cadillac Escalade, Escalade ESV, Chevrolet Silverado 2500, Silverado 3500, Suburban, Tahoe, GMC Sierra 2500, Sierra 3500, Yukon, Yukon XL and 2011-2013 Cadillac Escalade EXT, Chevrolet Avalanche, Silverado 1500, and GMC Sierra 1500 vehicles originally sold, or ever registered, in the states of AZ, AR, DE, DC, IL, IN, KS, KY, MD, MO, NE, NV, NJ, NM, NC, OH, OK, PA, TN, VA, and WV or "Zone B." Additionally, GM is recalling certain 2010-2014 Cadillac Escalade, Escalade ESV, Chevrolet Silverado 2500, Silverado 3500, Suburban, Tahoe, GMC Sierra 2500, Sierra 3500, Yukon, and Yukon XL and 2010-2013 Cadillac Escalade EXT, Chevrolet Avalanche, Silverado 1500, and GMC Sierra 1500 vehicles originally sold, or ever registered, in the states of AK, CO, CT, ID, IA, ME, MA, MI, MN, MT, NH, NY, ND, OR, RI, SD, UT, VT, WA, WI, and WY or "Zone C." These vehicles are equipped with non-desiccated passenger frontal inflators containing phase-stabilized ammonium nitrate (PSAN) propellant. These inflators may explode due to propellant degradation occurring after long-term exposure to high absolute humidity, high temperatures, and high temperature cycling.

Consequence & remedy

Consequence: An inflator explosion may result in sharp metal fragments striking the driver or other occupants, resulting in serious injury or death.

Remedy: GM will notify owners, and dealers will replace the front passenger air bag inflator with an alternate one, free of charge. Interim letters notifying owners of the safety risk were mailed on February 25, 2021. Second notification letters will be mailed once the remedy is available. Owner notification letters were mailed to 40 VIN owners on May 11, 2021. A second owner notification letter was mailed to all other owners on January 24, 2022. Owners may contact Chevrolet customer service at 1-800-222-1020; Cadillac customer service at 1-800-458-8006; and GMC customer service at 1-800-462-8782. GM's number for this recall is N212328800.

Model-level recall history does not show whether a particular VIN is affected or has received a repair. Check a VIN with NHTSA ↗

NHTSA investigations

2

DP22005 · Pedestrian Alert Sounds

Opened Jan 27, 2023 · Closed Aug 7, 2023

Status: closed (inferred from source dates) · Electrical System:propulsion System

NHTSA received a petition on or about July 18, 2022, requesting that Federal Motor Vehicle Safety Standard (FMVSS) 141 be applied to all electric and hybrid vehicles operating in the United States. The petition can be reviewed at NHTSA.gov under ODI Number 11486072. FMVSS 141 establishes performance requirements for pedestrian alert sounds for motor vehicles. The standard applies to hybrid and electric vehicles that have a gross vehicle weight rating of 4,536 KG or less or are defined as low-speed vehicles. The standard became fully applicable to all such vehicles manufactured on or after March 1, 2021.On January 27, 2023, NHTSA opened Defect Petition (DP) 22-005 to evaluate the subject matter described in the petition. On June 24, 2023 and as supplemented on June 25, 2023, the petitioner notified NHTSA he was withdrawing his petition. The petitioner indicated that, based on his review of data, there is no justification for asserting potential benefits that could be derived from actions sought by my petition. Based on the petitioner's withdrawal, DP22-005 is closed. Closure of this DP does not represent a determination by NHTSA regarding the subject matter of the petition.

EA21002 · Desiccated Air Bag Inflator Rupture

Opened Sep 17, 2021 · No close date supplied

Status: open (inferred from source dates) · Air Bags:frontal:driver Side:inflator Module; Air Bags:frontal:passenger Side:inflator Module

From 2000 through 2017, Takata produced millions of air bag inflators using two types of phase-stabilized ammonium nitrate ("PSAN") propellant -- propellant 2004 and propellant 2004L. After prolonged exposure to high temperature cycles and humidity, inflators using propellant 2004 can degrade, causing the propellant to burn too quickly when ignited. The rapid burning can cause the inflator to rupture during deployment, potentially causing serious or even fatal injury to vehicle occupants. See 2016 Blomquist Report at www.nhtsa.gov/sites/nhtsa.gov/files/documents/expert_report-hrblomquist.pdf.Consequently, all frontal inflators using propellant 2004 that do not contain a "desiccant" (a substance that traps and holds moisture) in US vehicles are under recall. These "non-desiccated" inflators either have been or are required to be replaced.In some cases, the remedy part for these recalled inflators was, or will be, an inflator using either propellant 2004 or 2004L that does contain a desiccant. None of these "desiccated" remedy parts (which were installed in older model year vehicles) are currently under recall for a degradation concern. Certain subsets of desiccated PSAN inflators using propellant 2004 for use as original equipment, however, have been recalled for a degradation concern. All Takata inflators produced with propellant 2004L contain desiccant, and none of these desiccated inflators using propellant 2004L are under recall for a degradation concern. There have been no reported field ruptures in any non-recalled desiccated PSAN inflators.It is understood that desiccants fully saturate at some threshold, at which point any additional moisture will not be captured. This means the degradation process observed in non-desiccated inflators using propellant 2004 may also occur in non-recalled desiccated inflators using propellant 2004, assuming additional moisture enters the inflator and high temperature cycling occurs. Based on available information, desiccant saturation can occur within the first five years in the worst environments, and the time required for full saturation is affected by multiple factors. While no present safety risk has been identified, further work is needed to evaluate the future risk of non-recalled desiccated inflators using propellant 2004.Three entities -- Takata (now known as TK Global), the Independent Testing Coalition, and Exponent -- have been studying the long-term behavior of Takata desiccated PSAN inflators using propellant 2004L (as well as 2004) in the presence of moisture and temperature cycling. The research efforts, which include development of predictive modeling techniques and field sample analysis, are ongoing. To date, none of the researchers have identified field evidence showing that propellant 2004L is undergoing a degradation process that leads to aggressive deployment and potential rupture. However, the time in service of such inflators remains short compared to that of the inflators using propellant 2004. Further study is needed to assess the long-term safety of desiccated inflators using propellant 2004L.The Office of Defects Investigation is opening this investigation to examine whether a safety defect related to propellant degradation exists in non-recalled desiccated PSAN frontal inflators manufactured by Takata. This investigation will require extensive information on Takata production processes and surveys of inflators in the field. Lists of recall actions that may have used desiccated PSAN inflators as remedy parts, as well as the makes and models originally manufactured with them, is available with the downloadable version of this document (see nhtsa.gov/recalls?nhtsaId=EA21002 -- note this information is subject to change/revision as the investigation proceeds). This investigation does not supersede EA15-001, which remains open.

Additional source detail variants (2)

Air Bags:frontal:driver Side:inflator Module

From 2000 through 2017, Takata produced millions of air bag inflators using two types of phase-stabilized ammonium nitrate ("PSAN") propellant -- propellant 2004 and propellant 2004L. After prolonged exposure to high temperature cycles and humidity, inflators using propellant 2004 can degrade, causing the propellant to burn too quickly when ignited. The rapid burning can cause the inflator to rupture during deployment, potentially causing serious or even fatal injury to vehicle occupants. See 2016 Blomquist Report at www.nhtsa.gov/sites/nhtsa.gov/files/documents/expert_report-hrblomquist.pdf.Consequently, all frontal inflators using propellant 2004 that do not contain a "desiccant" (a substance that traps and holds moisture) in US vehicles are under recall. These "non-desiccated" inflators either have been or are required to be replaced.In some cases, the remedy part for these recalled inflators was, or will be, an inflator using either propellant 2004 or 2004L that does contain a desiccant. None of these "desiccated" remedy parts (which were installed in older model year vehicles) are currently under recall for a degradation concern. Certain subsets of desiccated PSAN inflators using propellant 2004 for use as original equipment, however, have been recalled for a degradation concern. All Takata inflators produced with propellant 2004L contain desiccant, and none of these desiccated inflators using propellant 2004L are under recall for a degradation concern. There have been no reported field ruptures in any non-recalled desiccated PSAN inflators.It is understood that desiccants fully saturate at some threshold, at which point any additional moisture will not be captured. This means the degradation process observed in non-desiccated inflators using propellant 2004 may also occur in non-recalled desiccated inflators using propellant 2004, assuming additional moisture enters the inflator and high temperature cycling occurs. Based on available information, desiccant saturation can occur within the first five years in the worst environments, and the time required for full saturation is affected by multiple factors. While no present safety risk has been identified, further work is needed to evaluate the future risk of non-recalled desiccated inflators using propellant 2004.Three entities -- Takata (now known as TK Global), the Independent Testing Coalition, and Exponent -- have been studying the long-term behavior of Takata desiccated PSAN inflators using propellant 2004L (as well as 2004) in the presence of moisture and temperature cycling. The research efforts, which include development of predictive modeling techniques and field sample analysis, are ongoing. To date, none of the researchers have identified field evidence showing that propellant 2004L is undergoing a degradation process that leads to aggressive deployment and potential rupture. However, the time in service of such inflators remains short compared to that of the inflators using propellant 2004. Further study is needed to assess the long-term safety of desiccated inflators using propellant 2004L.The Office of Defects Investigation is opening this investigation to examine whether a safety defect related to propellant degradation exists in non-recalled desiccated PSAN frontal inflators manufactured by Takata. This investigation will require extensive information on Takata production processes and surveys of inflators in the field. Lists of recall actions that may have used desiccated PSAN inflators as remedy parts, as well as the makes and models originally manufactured with them, is available with the downloadable version of this document (see nhtsa.gov/recalls?nhtsaId=EA21002 -- note this information is subject to change/revision as the investigation proceeds). This investigation does not supersede EA15-001, which remains open.

Air Bags:frontal:passenger Side:inflator Module

From 2000 through 2017, Takata produced millions of air bag inflators using two types of phase-stabilized ammonium nitrate ("PSAN") propellant -- propellant 2004 and propellant 2004L. After prolonged exposure to high temperature cycles and humidity, inflators using propellant 2004 can degrade, causing the propellant to burn too quickly when ignited. The rapid burning can cause the inflator to rupture during deployment, potentially causing serious or even fatal injury to vehicle occupants. See 2016 Blomquist Report at www.nhtsa.gov/sites/nhtsa.gov/files/documents/expert_report-hrblomquist.pdf.Consequently, all frontal inflators using propellant 2004 that do not contain a "desiccant" (a substance that traps and holds moisture) in US vehicles are under recall. These "non-desiccated" inflators either have been or are required to be replaced.In some cases, the remedy part for these recalled inflators was, or will be, an inflator using either propellant 2004 or 2004L that does contain a desiccant. None of these "desiccated" remedy parts (which were installed in older model year vehicles) are currently under recall for a degradation concern. Certain subsets of desiccated PSAN inflators using propellant 2004 for use as original equipment, however, have been recalled for a degradation concern. All Takata inflators produced with propellant 2004L contain desiccant, and none of these desiccated inflators using propellant 2004L are under recall for a degradation concern. There have been no reported field ruptures in any non-recalled desiccated PSAN inflators.It is understood that desiccants fully saturate at some threshold, at which point any additional moisture will not be captured. This means the degradation process observed in non-desiccated inflators using propellant 2004 may also occur in non-recalled desiccated inflators using propellant 2004, assuming additional moisture enters the inflator and high temperature cycling occurs. Based on available information, desiccant saturation can occur within the first five years in the worst environments, and the time required for full saturation is affected by multiple factors. While no present safety risk has been identified, further work is needed to evaluate the future risk of non-recalled desiccated inflators using propellant 2004.Three entities -- Takata (now known as TK Global), the Independent Testing Coalition, and Exponent -- have been studying the long-term behavior of Takata desiccated PSAN inflators using propellant 2004L (as well as 2004) in the presence of moisture and temperature cycling. The research efforts, which include development of predictive modeling techniques and field sample analysis, are ongoing. To date, none of the researchers have identified field evidence showing that propellant 2004L is undergoing a degradation process that leads to aggressive deployment and potential rupture. However, the time in service of such inflators remains short compared to that of the inflators using propellant 2004. Further study is needed to assess the long-term safety of desiccated inflators using propellant 2004L.The Office of Defects Investigation is opening this investigation to examine whether a safety defect related to propellant degradation exists in non-recalled desiccated PSAN frontal inflators manufactured by Takata. This investigation will require extensive information on Takata production processes and surveys of inflators in the field. Lists of recall actions that may have used desiccated PSAN inflators as remedy parts, as well as the makes and models originally manufactured with them, is available with the downloadable version of this document (see nhtsa.gov/recalls?nhtsaId=EA21002 -- note this information is subject to change/revision as the investigation proceeds). This investigation does not supersede EA15-001, which remains open.